M. Marechal, M. Delbarre, J. Tesson, C. Lacambre, F. Froussart-Maille Percy Military Hospital, Clamart, FRANCE

Similar documents
A Modified Protocol for Color Vision Screening Using Ishihara

City, University of London Institutional Repository

ROY G BIV COLOR VISION EXPLORED

User s Manual Color Vision Recorder version 4

VISUAL MILL LAB. SECTION 1: Complete the following tests and fill out the appropriate sections on your Visual Mill Color Deficit Worksheet.

Everything You Wanted to Know About Color Vision

This set of slides were used by Professor Cole in his talk on the occasion of the 60th anniversary of CIE Australia.

INTRODUCTION TO GRAPHICS. Color Vision Simulator Examples

Automatic Testing of Color Blindness

Historically, the development of colour vision tests

CSE Data Visualization. Color. Jeffrey Heer University of Washington

Farnsworth F100 Hue Test Instructions

620 Rejwrts Investigative Ophthalmology

Analysis and Improvement of the Open- StreetMap Street Color Scheme for Users with Color Vision Deficiencies

Power saving in LCD panels

UNUSUAL PREVALENCE OF COLOR VISION DEFECTS IN CHILDREN FROM A SMALL BULGARIAN TOWN

I 1 \ 2.2 ~ ~~ i ~~ I I IIII ~ urn I.25 ~ ffff ~ MICROCOPY RLSOLWI ON ILS1 CHART. I ~ UIH AI) o t ~~~~ ~~

The Art and Science of Depiction. Color. Fredo Durand MIT- Lab for Computer Science

~AM> P. v. SIEGEL, M.D.

Mapping: Methods & Tips

Optokinetic technique for measuring infants' responses to color

Visual Imaging and the Electronic Age Color Science

Visual Imaging and the Electronic Age Color Science

VT-S730. Omron's 3D-SJI For Efficient Manufacturing of High-quality Products. Best the Minimum Q cost! PCB Inspection System VT-S730 NEW

The potentials of the flicker electroretinogram (ERG)

NOTIFICATION OF A PROPOSAL TO ISSUE A CERTIFICATION MEMORANDUM

Project Summary EPRI Program 1: Power Quality

Calibration of Colour Analysers

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

D.A. Schreuder Voorburg, ]981 Institute for Road Safety Research SWOV, The Netherlands

WEATHERPROOF LUMINAIRE

Visiolite Master PC-based Virusscreener

AOC ADVANCED OPHTHALMIC CHART. Professional. Intuitive. Stylish. ...the ultimate solution for your acuity charts needs!

HMC Anomaloskop MR. HMC Anomaloskop R. Instruction Manual. Moreland and Rayleigh (Typ 47700) Rayleigh (Typ 47720)

STANDARDISATION OF LIGHT SIGNALS FOR ROAD TRAFFIC CONTROL

Cisco Video Surveillance 6400 IP Camera

System Level Simulation of Scheduling Schemes for C-V2X Mode-3

Introduction & Colour

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION

Selected Problems of Display and Projection Color Measurement

Paper for Consideration by the Digital Information Portrayal Working Group (DIPWG) Comment about recommendation on S-52 Colour Calibration Procedure

Medical Imaging Working Group

Application of cepstrum prewhitening on non-stationary signals

Advanced backlights for LCD cockpit displays

Three large LCD cockpit concept for retrofit applications

Digitized Signals are the Future of the Black Box

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

Edge-Aware Color Appearance. Supplemental Material

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

THE OPERATION OF A CATHODE RAY TUBE

LED-Strip C12 MK2.6. Product Sheet

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

+ Human method is pattern recognition based upon multiple exposure to known samples.

Background Statement for SEMI Draft Document 5291A New Standard: TEST METHOD OF AMBIENT COLOR GAMUT FOR FPD UNDER INDOOR ENVIRONMENTS

Skip Length and Inter-Starvation Distance as a Combined Metric to Assess the Quality of Transmitted Video

Role of Color in Telemedicine Applications. Elizabeth A. Krupinski, PhD

Failure Analysis Technology for Advanced Devices

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

Understanding Human Color Vision

High productivity rapid manufacturing systems DIGITALWAX X. for general applications

THE OPERATION OF A CATHODE RAY TUBE

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison

R xx-C0900-J074

DMX-Splitter 4. User Manual

Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS Effective Date: 10/19/2012 LITE-ON DCC RELEASE

rapid flicker Department of Psychology, University of California, San Diego, La Jolla, California

BUREAU OF ENERGY EFFICIENCY

American National Standard for Electric Lamps Specifications for the Chromaticity of Solid-State Lighting Products

[source unknown] Cornell CS465 Fall 2004 Lecture Steve Marschner 1

Ablaufautomatisierung zur virtuellen Optimierung von Blechhalterkraftverläufen

Deviations request #76 for an ETSO approval for CS-ETSO applicable to Airborne Multipurpose Electronic Displays (ETSO-C113) Consultation Paper

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

True comfort and flexibility with the power of 3T.

Examiners Report/ Principal Examiner Feedback. Summer GCE Music 6MU05 Composition and Technical Study

UNIVERSITY OF DUBLIN TRINITY COLLEGE

Guidelines for Specification of LED Lighting Products 2010

Improving Color Text Sharpness in Images with Reduced Chromatic Bandwidth

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED-Strip C25 MK2.6. Product Sheet

An Introduction to TrueSource

American National Standard for Electric Lamps Specifications for the Chromaticity of Solid-state Lighting Products

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

Is image manipulation necessary to interpret digital mammographic images efficiently?

Investigation of Color Rendering Performance Indicators for Lighting Systems

A DESIGNER S GUIDE TO COLOR BLINDNESS

Beyond the Resolution: How to Achieve 4K Standards

PLCC W LC CRI80 Datasheet

Minimizing the Perception of Chromatic Noise in Digital Images

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Evaluating and Specifying LED Lighting

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Processes for the Intersection

MX194. Your advantages. 1MP Medical-Display

Monitor QA Management i model

PLCC 5630B 0.5W High CRI Datasheet

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

PLCC W CRI 80 Datasheet

The Aeronautical Journal

CATHODE-RAY OSCILLOSCOPE (CRO)

Transcription:

A Performance Comparison of Color Vision Tests for Pilots Requirement M. Marechal, M. Delbarre, J. Tesson, C. Lacambre, F. Froussart-Maille Percy Military Hospital, Clamart, FRANCE

Introduction Color-deficiency 9 % of men and 0.5 % of women 1.5 to 3% of military pilots candidates (Air Force) 11 to 13% of ophthalmologic incapacity Anomalous trichromats Protanomalous trichromat (abnormal cone) Deuteranomalous trichromat Dichromats (absent cone) Protanopes Deuteranopes Maille M, Crepy P. Les nouvelles normes visuelles en aéronautique militaire. Médecine Aéronautique Spatiale. 1990;XXIX:261 2

Introduction Color use in aviation access to information : first symbol, text, or sound. PAPI (Precision Approach Path Indicator) is the more critical Other are less problematic : Parking lights Taxiways Regulatory lights of airplanes.

Introduction Color is more and more present in cockpits, "glass cockpits : LCD screens with electronic process of many instruments of flights, whose display is multicolored. Colors choice : free to the manufacturer Located in different areas of confusion according to MacAdam ellipses

Introduction - rules In France : Decree of 27 January 2005 and follow the regulations of EASA - pass the Ishihara 24 plate test (first 15 plates identified without error or hesitation) - normal trichromat at the Nagel anomaloscope Normal Color vision - identification without mistake or hesitation of colored lights in Beyne lantern (presented at 5 meters for 1 second with 3 minutes of arc aperture) - matching range is 4 scale units or less to the Nagel anomaloscope Color vision Safe

Introduction - rules In France : Decree of 27 January 2005 and follow the regulations of EASA - pass the Ishihara 24 plate test (first 15 plates identified without error or hesitation) - normal trichromat at the Nagel anomaloscope Normal Color vision - identification without mistake or hesitation of colored lights in Beyne lantern (presented at 5 meters for 1 second with 3 minutes of arc aperture) - matching range is 4 scale units or less to the Nagel anomaloscope Color vision Safe Secondary tests in other countries In UK : Holmes-Wright lantern or CAD test In Germany : Anomaloscope In USA : Farnsworth and Optec lanterns or Titmus vision test In Canada : lantern test or Farnsworth D15 In New Zeland : Farnsworth and Holmes-Wright lanterns, Farnsworth D15 or CAD test

Introduction Lanterns : no more commercialized (only Fletcher-Evans CAM lantern) Aim of the study To assess the abilities of 8 color vision tests for screening, qualification and quantification of red / green hereditary deficiency, to improve and to adapt the current color selection protocols.

Methods Prospective study September 2016 to May 2017 CPEMPN of Percy hospital, in Clamart (France). INCLUSION Color-deficient subjects: addressed for a failure in reading the Ishihara plates by - military selection center - or Aviation Medical Examiner. Color vision normal subjects : healthy volunteers. EXCLUSION BCVA less than 6/10. Sunglasses or tinted contact lenses. Ophthalmologic pathology (evolutionary or sequelar).

Methods - color vision test Ishihara Beyne lantern Fletcher lantern Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test Ishihara 38 plates Out of order at 70 cm of distance, at 45 3 seconds for each plate successful if the first 17 plates were viewed without error or hesitation.

Methods - color vision test Ishihara Beyne lantern Fletcher lantern Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test Beyne lantern type aviation simple colored lights, in random order low mesopic conditions, at 5 meters any hesitation or false answer = an error 2 protocols without cited colors military civilian 1 s / 4 : presentation 1 second with 4 minutes of arc aperture 1/25 th s / 2 : presentation 1/25 th second with 2 minutes of arc aperture 2 protocols with colors cited (red, green, blue, yellow-orange and off-white) 1 s / 3 : presentation 1 second with 3 minutes of arc aperture 1 s / 3 x 3 presentations (pass if no error on 2 of 3 presentation)

Methods - color vision test Ishihara Beyne lantern Fletcher lantern Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test Fletcher-Evans CAM lantern two lights, vertically 6 meters 5 colors : 2 Red, 2 Green, 1 White 9 combinations Informative phase : colors presented and cited 'red', 'green' and 'white. test phase : 0.9 minute of arc, 2 seconds First round : pass if no error Two more rounds if errors

Methods - color vision test Ishihara Beyne lantern Fletcher lantern Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test Arrangement tests Farnsworth D15 to classify the 16 pawns in a time of 3 minutes. successful if no confusion right (circular scheme) a straight between the pawns 7 and 15, a simple pawns inversions. Desaturated Lanthony 15 Hue successful if less than 2 lines of confusion Farnsworth-Munsell 100 Hue 2 minutes /box x 4 axis of the deficiency severity score

Methods - color vision test Ishihara Beyne lantern Fletcher lantern Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test The CAD Test (Colour Assessment and Diagnosis) Mesopic condition at 1.40 meter in front of the viewing screen, 3 steps 'learning mode : check the test understanding. 'fast screening : identify a large part of the healthy subjects. definitive CAD : determine the chromatic sensitivity of the subject present for each wavelength stimuli of varying intensity. determines the axis and severity according to a score (RG for the Red-Green axis and YB for blue-yellow axis) Ability according to UK threshold : RG < 6 SN for protans and RG< 12 SN for deutans Healthy subjects : score < 2 SN

Methods - color vision test Ishihara Beyne lantern Fletcher lanter Farnsworth D15 Arrangements test Lanthony 15 Hue Munsell 100 Hue CAD (Colour Assessment and Diagnosis) test Anomaloscope Nagel type

Methods - color vision test The anomaloscope IF2, Tomey Rayleigh equation, on the dominant eye in mesopic conditions 2 modes : Automatic or Manual identifies the deficiency axis, differentiates anomalous trichromats from dichromats, or class the subject in normal color vision matching range severity Safe : if matching range less than 4 units at the Nagel anomaloscope

Methods 2 groups : CVD : color vision deficient CVN : color vision normal For each test, evaluation of : Sensibility, Specificity, Positive and negative predictive values Application to aeronautic : Total number and success ratio for class 1 ability Severity assessing : ROC curves for dichromatism diagnosis for CAD test and 100 Hue

Results 55 subjects 32 color vision deficient subjects (CVD). 3 were excluded (missing results) 23 color vision normal subjects (CVN). 29 VCD 23 VCN p 23 years ± 6.09 26 ± 6.1 years p = 0.075 0 woman 9 women p = 0.015-11 deuteranomalous trichromats (37.9%) - 7 protanomalous trichromats (24.1%) - 6 protanopes (20.69%) - 5 deuteranopes (17.24%)

Results Se Sp PPV NPV ISHIHARA 0.97 1.00 1.00 0.96 Detection of color-deficiency tests power FARNSWORTH D15 0.58 1.00 1.00 0.64 LANTHONY HUE desaturated 0.79 1.00 1.00 0.79 MUNSELL 100 HUE 0.79 0.96 0.96 0.79 1s / 4' 0.79 0.96 0.96 0.79 BEYNE Lantern 1/25 th s 2' 0.97 0.57 0.76 0.93 1s / 3' 0.76 0.96 0.96 0.76 1 s 3' x 3 series 0.69 1.00 1.00 0.72 FLETCHER Lantern 1 presentation 1.00 0.78 0.85 1.00 2 retests 0.97 1.00 1.00 0.96 CAD test 1.00 1.00 1.00 1.00 ANOMALOSCOPE Automatic 0.97 0.96 0.97 0.96 Manual 1.00 1.00 1.00 1.00

Results Total number and success ratio for a class 1 ability for CVD Test Deuteranomalous Protanomalous All Deuteranopes Protanopes trichromats trichromats n = 11 in % n = 5 in % n = 7 in % n = 6 in % n=29 in % ISHIHARA 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 FARSNWORTH D15 5 45.45 0 0.00 5 71.42 2 33.33 12 41.38 LANTHONY D15 4 36.36 0 0.00 2 28.57 0 0.00 6 20.69 MUNSELL 100HUE 3 27.27 0 0.00 2 28.57 1 16.67 6 20.69 1s / 4' 5 45.45 0 0.00 1 14.29 0 0.00 6 20.69 Beyne lantern 1/25 th s / 2' 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 1s / 3' 3 27.27 1 20.00 2 28.57 1 16.67 7 24.14 1s / 3' x 3 6 50.00 0 0.00 2 28.57 1 16.67 9 31.03 Fletcher 1 present. 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 lantern 2 retests 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 CAD test 2 18.18 0 0.00 1 14.29 0 0.00 3 10.34 ANOMALOSCOPE 4 36.36 0 0.00 2 28.57 0 0.00 6 20.69

Results Total number and success ratio for a class 1 ability for CVD Test Deuteranomalous Protanomalous All Deuteranopes Protanopes trichromats trichromats n = 11 in % n = 5 in % n = 7 in % n = 6 in % n=29 in % ISHIHARA 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 FARSNWORTH D15 5 45.45 0 0.00 5 71.42 2 33.33 12 41.38 LANTHONY D15 4 36.36 0 0.00 2 28.57 0 0.00 6 20.69 MUNSELL 100HUE 3 27.27 0 0.00 2 28.57 1 16.67 6 20.69 1s / 4' 5 45.45 0 0.00 1 14.29 0 0.00 6 20.69 Beyne lantern 1/25 th s / 2' 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 1s / 3' 3 27.27 1 20.00 2 28.57 1 16.67 7 24.14 1s / 3' x 3 6 50.00 0 0.00 2 28.57 1 16.67 9 31.03 Fletcher 1 present. 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 lantern 2 retests 1 9.09 0 0.00 0 0.00 0 0.00 1 3.44 CAD test 2 18.18 0 0.00 1 14.29 0 0.00 3 10.34 ANOMALOSCOPE 4 36.36 0 0.00 2 28.57 0 0.00 6 20.69

CVD Ishihara D15 15HUE Lanthony. Results 100 HUE BEYNE lantern FLETCHER lantern 1/4 1/25 th 2 1/3 3 tests 1 test 2 retests 1 fail fail fail fail fail fail fail PASS fail fail fail fail 2 fail PASS PASS fail fail fail fail Fail fail fail PASS PASS 4 fail PASS PASS fail fail fail PASS PASS fail fail fail PASS 5 fail PASS fail fail fail fail fail fail fail fail fail fail 6 fail PASS fail fail fail fail fail fail fail fail fail fail 7 fail fail fail fail fail fail PASS PASS fail fail fail fail 11 fail fail fail fail fail fail PASS fail fail fail fail fail 14 fail fail fail fail PASS fail fail fail fail fail fail PASS 15 fail PASS fail fail PASS fail fail fail fail fail fail fail 16 fail fail fail fail fail fail fail PASS fail fail fail fail 17 fail PASS fail fail fail fail fail fail fail fail fail fail 20 fail PASS PASS fail fail fail fail PASS fail fail PASS fail 22 fail fail fail PASS fail fail fail fail fail fail fail fail 24 fail PASS PASS fail PASS PASS PASS PASS fail fail fail PASS 25 fail fail fail fail fail fail PASS PASS fail fail fail fail 26 fail PASS fail PASS fail fail PASS PASS fail fail fail fail 27 fail fail fail fail PASS fail fail fail fail fail fail fail 29 fail PASS fail PASS PASS fail fail fail fail fail fail PASS 30 fail PASS PASS PASS fail fail fail PASS fail PASS PASS PASS 31 fail fail PASS PASS fail fail fail fail fail fail fail fail CAD test Anomal.

Results Deficit quantification CAD test 100 Hue : difference between achieved score and physiologic score 100 Hue : achieved score AUC: - 0,98 [0,94 ; 1,01] for CAD test - 0,65 [0,47 ; 0,83] for score difference - 0,69 [0,52 ; 0,86]for 100 Hue Best cut-off: - RG > 18,5 for CAD test - Score difference > 22 - Score > 112 for 100 Hue

Discussion Walsh in 2016, USA 65 CVD subjects and 68 CVN subjects of US Army. Our results : similar except a better diagnostic efficiency of the CAD test. Test Sensitivity Specificity CAD test 0.86 0.85 to 1.00 Farnsworth D15 0.35 1.00 FALANT 0.92 to 0.86 0.96 3 presentations 0.83 to 0.85 0.97 to 0.99 PIPIC 0.98 0.96 to 1.0 good efficiency of the computerized tests CCT and CAD operator-independent and randomized patterns Walsh DV, Robinson J, Jurek GM, Capó-Aponte JE, Riggs DW, Temme LA. A Performance Comparison of Color Vision Tests for Military Screening. Aerosp Med Hum Perform. 2016 Apr;87(4):382 7.

Discussion Squire et al. in 2005, UK 3 lanterns (Beyne, Spectrolux, and Holmes-Wright) and Nagel anomaloscope. 55 CVD subjects and 24 CVN subjects. all dichromats failed the 4 tests. pass one secondary test : not guaranteed to pass the other tests Tests authorized by the EASA standards : high variability and inconsistency of their results. Squire TJ, Rodriguez-Carmona M, Evans ADB, Barbur JL. Color vision tests for aviation: comparison of the anomaloscope and three lantern types. Aviat Space Environ Med. 2005 May;76(5):421 9.

Discussion British CAA, 2006 117 CVD Ability of PAPI lights recognition and CAD test results No subject who pass CAD test failed to PAPI simulator. (pass : RG < 6 SN for protan or RG < 12 SN for deutan) CAD test : pass in 36.1 % of deuteranomalous trichromats 29.8% of protanomalous trichromats In our study : only 18.2% deuteranomalous trichromats 14.3% protanomalous trichromats Barbur JL, Rodriguez-Carmona M, Evans S, Milburn N. Minimum Colour Vision Requirements for Professionnal Flight Crew. Recommendations for a new colour vision standards. Safety Regulation Group. Civil Aviation Authority; 2009.

Discussion Fletcher in 2005 Similar to Holmes-Wright lantern : 2 lights with a 0.9 minute arc aperture. Colors used : slight differences in the CIE diagram. 9 / 71 normal trichromats : mistakes in first pass. 18 color-deficient subjects : all failed. Fletcher-Evans CAM lantern : very sensitive. good test for clinical diagnosis, not for chromatic selection. Birch in 2008 Holmes-Wright lantern type A 125 color-deficient subjects: 10 subjects (9%) were able to pilot Nevertheless, Fletcher lantern not comparable to the Holmes-Wright lantern (passing 9 to 30% of CVD) - Fletcher R. The Fletcher CAM lantern colour vision test. Optom Today. 2005 Jul;(29):24 6. - Birch J. Performance of colour-deficient people on the Holmes-Wright lantern (type A): consistency of occupational colour vision standards in aviation. Ophthalmic Physiol Opt. 2008 May;28(3):253 8.

Discussion Professional selection specificity Candidates try to minimize their color-vision deficit / learn Ishihara consider any hesitation / mistake as failure. testing protocol should be strictly respected and examiners must be trained, that can be an impediment to the use of anomaloscope In some cases, automatic mode may fail to categorize the candidate.

Discussion Test duration is to take in account in a screening context. Ishihara album : 2 minutes Beyne lantern : 1 mn, and Fletcher-Evans CAM lantern : 5 mn Both test of D15 : 2-3 mn, 100 Hue : 15 mn Anomaloscope with both automatic and manual mode : 20 mn CAD test : < 5 mn if "Fast screening" is successful. In our study, 6 CVN (26%) had Definitive CAD : 8 mn for red/green (3-4 mn for blue / yellow if necessary).

Discussion CAD test Advantages Can t be learn Reproducible Red / green and yellow / blue axis 16 colors Quantitative test Lanterns Advantages Quick Easy Less expensive Ergonomic test

Conclusion Many tests are used for pilots ability. Their results are discordant lanterns are no more commercialized. CAD test and anomaloscope : most accurate in our study Recent increase of colored signals in new generation cockpits. Multitude of color amount. The acceptable color-deficiency for a pilot to be safe is difficult to determine, as well as the risk of not detected blue-yellow deficiency.

Thank you for your attention

Discussion In conclusion Ishihara plates : excellent screening test for red / green deficiency. Farnsworth D15 : quick and easy but some dichromats subjects can pass this test. Lanthony 15 Hue test : ability of 20% and seems suitable for use in professional selection. Munsell 100 Hue : too long Fletcher-Evans CAM lantern : too restrictive Beyne lantern : simple and quick to use, but some dichromats pass. Anomaloscope : qualify and quantify the deficiency requires a strong experience of the examiner. CAD test : quantitative test, yellow/blue and red/green thresholds used by the British CAA seem to be more restrictive More expensive

Results Assessment of the axis of the color-deficiency ANOMALOSCOPE Diagnosis ISHIHARA D15 LANTHONY 15HUE 100 HUE CAD deutan 15 11 9 12 16 all CVD protan 9 6 12 6 13 n = 29 not defined 5 12 8 11 0 Deuteranomalous deutan 10 6 5 6 11 Trichromats protan 0 0 2 0 0 n = 11 not defined 1 5 4 5 0 deutan 5 5 4 5 5 Deuteranopes protan 0 0 0 0 0 n = 5 not defined 0 0 1 0 0 Protanomalous deutan 0 0 0 1 0 Trichromats protan 4 2 4 2 7 n = 7 not defined 3 5 3 4 0 deutan 0 0 0 1 0 Protanopes Protan 5 4 6 4 6 n = 6 not defined 1 2 0 2 0