ST-4000D SIGNAL LEVEL METER

Similar documents
ST-4000 SIGNAL LEVEL METER

SAWM60 AUDIO/VIDEO MODULATOR

HMA-860H AGILE MODULATOR

INSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator

INSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator

TR-2 OPERATION MANUAL

User s Manual of Signal Level Meter TABLE OF CONTENTS

HD-CM HORIZON DIGITAL CABLE METER

Introduction 2. Installation 3. Suggested Configuration 4. Using the Remote 5. Adjustment Mode 6. Technical Specifications 7. Technical Support 8

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Model Two and Model Two Lite Signal Level Meters OPERATION MANUAL

SAFETY AND NOTICE TABLE OF CONTENTS

USB-TG124A Tracking Generator User Manual

Instruction Guide. The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB. The Professionals Source For Hard-to-Find Computer Parts

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

1:4 VGA Hub EXT-VGA-144 USER S MANUAL.

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

CV-005B. Mini Component to HDMI Converter. User Manual. Made in Taiwan

NS-3 RF Noise Source Operation Manual

Digital Terrestrial Alignment & Installation Meter

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

SP x6 12G/6G/3G/HD/SD-SDI Distribution Amplifier with Reclocking. User Manual. rev: Made in Taiwan

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

Kramer Electronics, Ltd. USER MANUAL. Model: Power Amplifier

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

DS2460Q QAM Analysis Meter

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

LTS-1500 Fiber Optic Test Set Operating Instructions

PRO-ScalerV2HD VGA to HDMI & Audio Scaler Converter. User s Guide. Made in Taiwan

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

Sport-TIMER 3000 TM Instruction Manual

3G/HD/SD-SDI to HDMI Converter with Audio Extraction and Mixer

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Garmin GC 10 Marine Camera Instructions

32 Channel CPCI Board User Manual

SDI-HDSDXPRO. USER MANUAL Version 1.1

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200N5. 1:2 High Resolution UXGA DA

User Manual rev: Made in Taiwan

Cablesson HDelity 7.1ch Audio Extractor & Mixer. User Manual

Model R177M and R177S Baseband Switch

Kramer Electronics, Ltd. USER MANUAL. Models: PT-102AN, 1:2 Audio DA PT-102SN, 1:2 s-video DA

1X4 HDMI Splitter with 3D Support

Kramer Electronics, Ltd.

HD-TM PLUS HORIZON DIGITAL TERRESTRIAL METER

XR-3 QAM 8VSB. Modular Test Instrument. XR-3 Rugged Adaptable Economically Efficient Configurable to test: and more

SDI-SDHDXPRO User Manual. Version1.2

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Kramer Electronics, Ltd. USER MANUAL. Model: PT-102VN. 1:2 Video DA

Model Three Signal Level Meter. Operation Manual

CrystalView DVI Micro-DL Extender

SATFINDER 3 HD SLIM USER GUIDE

Indoor/Outdoor Security System with Quad Monitor User s Manual

DisplayMax 5000 P/A MER BER C/N MODEM INGRESS LEAKAGE CHANNEL FREQUENCY FAVORITE CHANNELS. DisplayMax 5000 SIGNAL LEVEL METER.

3G/HD/SD-SDI to HDMI Converter

3GSDI to HDMI 1.3 Converter

Kramer Electronics, Ltd. USER MANUAL. Model: 810B. Black Burst / Audio Generator

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

Kramer Electronics, Ltd.

USER MANUAL. Kramer Electronics, Ltd. Models:

Kramer Electronics, Ltd. USER MANUAL. Model: CV / YC to SDI Converter

Kramer Electronics, Ltd. USER MANUAL. Model: SG-6005xl. Genlock Multistandard SPG/Audio Generator

DTV742 Installation Quick Start Guide

Kramer Electronics, Ltd.

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

PRO-HDMI2DP HDMI 2.0a to DisplayPort 1.2a Converter. User s Guide. Made in Taiwan

Owner s Manual. Sat-Meter MSK 15. Order No.:

MaxView Cinema Kit Quick Install Guide

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

DVI to HD-SDI Conversion Box

SDI-HDRPTPRO. User Manual. HD-SDI Repeater with Signal Equalization & Re-clocking. Version 1.2

Quick Start Guide Camera Slot Dual UHF Receiver

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

2 FRONT PANEL CONTROLS and INDICATORS 1 TM DUC864 DIGITAL UPCONVERTER 12 POSITION RACK MOUNT POWER SUPPLY. Figure 1

VK-P10SE WARRANTY REGISTRATION FORM

VideoSplitter HDMI 4K PT

Kramer Electronics, Ltd. USER MANUAL. Model: VM-312. Multi-Format Video/Audio Distributor

Composite Video Extender

True RMS AC/DC Mini Clamp Meter

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Kramer Electronics, Ltd. USER MANUAL. Model: VS-211HDxl. 3G HD-SDI Automatic Standby Switcher

VGA Extender SRN. EXT-VGA-141SRN. User Manual

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

Kramer Electronics, Ltd. USER MANUAL. Model: PT-101Hxl. HDMI Repeater

ARIS EXPLORER 1200 GETTING STARTED

DisplayPort Extender over 2 LC Fibers

X-70B HDTV DIGITAL INDOOR ANTENNA

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200Dxl. XGA Differential Amplifier / DA

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

2X1 VGA W/ STEREO AUDIO (AUTOMATIC) SWITCHER ATL-ATAPC21A

MYE TV Audio Grabber

SX7. Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY

Kramer Electronics, Ltd. USER MANUAL. Model: VP-4x4. 4x4 VGA/XGA Audio Matrix Switcher

Instruction Manual Model # Block Upconverter

Transcription:

ST-4000D SIGNAL LEVEL METER Rev 100606

Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions..... 3 Main User Instructions: 1 Meter Set-Up Features...... 4 1.1 Auto Off Time.. 4 1.2 Audio Set..... 4 1.3 Measurement Scale..... 4 2 Selecting CATV, VHF/UHF or Off-Air Digital Channels. 5 3 Configuring Channel Line Up... 5 3.1 Channel Plan... 5 3.2 Channel Edit.... 5 4 Meter Calibration....... 6 4.1 Correct CH db (Calibration)..... 6 4.2 Clear Correct (Restore Factory Calibration)...... 6 5 Scanning Channels Saving and Viewing Data... 7 5.1 Scanning and Saving Data.... 7 5.2 Viewing Stored Data... 7 6 Measuring Signal Levels 6.1 Single (NTSC) Channel Signal Level Measurement - V, A or V/A 8 6.2 Single (ATSC) Channel Signal Level Measurement 8 6.3 Frequency Based Signal Level Measurement. 8 Warranty..... 9

FEATURES * Select Channels 2 136 CATV (NTSC) * 12 Hour Rechargeable Ni-MH Battery 2 69 Off-Air (NTSC) 2 69 Off Air (ATSC) * Select Frequency 46-870 MHz * Auto Shut Off * Measures Video, Audio, or V-A * Charging LED dbmv or dbuv (selectable) * Scan Selected Channels and Store Signal Level Data SPECIFICATIONS Frequency and Level Range: Resolution Bandwidth: Channels: Level Range: Accuracy: Input impedance Wave detection 46 to 870MHz in 10 khz steps 280KHz ± 50KHz All user designated NTSC Channels, 2-69 ATSC -28 dbmv to +55 dbmv (32dBµV to- 115dBµV) ±2.5dB 75Ω Peak value AUTO SCAN TESTING Max Channel Scan: 135 Channels Scan Range: Ch 2-69 VHF/UHF, Ch 2-136 CATV and Ch 2-69 ATSC Scan Speed: 30 Channels/Min Memory Groups 18 Groups (01--18) Each group stores up to 135 Channels OTHERS Dimensions: 214mm x 94mm X 47mm Weight: 1.4 kg (with charger) Working Temperature: -10 to + 40 Display LCD: 16X2 LCD with back light POWER Battery: 7.2V/1.6AH Ni-MH Power Supply / Battery Charger AC 110V/60Hz ±10% Battery Life: 5 hours of continuous operation Recharging Time: 12 hours STANDARD ACCESORIES Battery Charger: 1 pc Carrying Case w/strap 1 set Barrel Connector: G-F81F* 2 pcs Operators Manual 1 copy Quick Users Guide 1 copy Electronic copies of the Users Manual & Quick Users Guide are available on our website: www.hollandelectronics.com/support.html 1

KEYPAD ILLUSTRATION KEYPAD CONTROLS 1. Numerical 1 / 2 nd Operation SCAN Scan and save signal level values for selected channels in a memory group 2. Numerical 2 / 2 nd Operation LOAD - View data previously stored in a memory group 3. Numerical 3 / 2 nd Operation V/A Select Video, Audio or V/A carrier display screens 4. Numerical 4 / 2 nd Operation SET Access the meter Settings menu screens 5-9. Numerical 5-9 10. Numerical 0 / 2 nd Operation Function Key Pressing 2 nd F activates the secondary programmed function of the next key that is pushed 11. CLR /. Pressing this key while in a menu screen will return to the previous menu. This key is also used as both a decimal point and the final key after entering a frequency value, before pressing ENT. 12. ENT Pressing ENT allows for entering desired function or setting 13. I On/Off Turn meter power on or off 14-15. UP Arrow Increase the displayed channel or frequency. Also used to navigate through the Settings menu. DOWN Arrow - Decrease the displayed channel or frequency. Also used to navigate through the Settings menu 16. LED Indicator AC Power / Battery Charging Indicator 2

Getting Started Powering the Meter The ST-4000D can be powered either by the internal rechargeable Ni-MH batteries or by use of the included power supply/battery charger. A) Using the external AC power supply: Make sure that the available AC line voltage is 110-120V, 60 Hz. Connect the DC output plug from of the adapter / charger to the DC receptacle on the bottom of the ST4000D meter. B) Powering the meter with internal batteries: In order for the ST4000D meter to operate from the internal batteries, a sufficient charge must exist on the batteries. The recommended time to fully charge the batteries is 12 hours. Only use the power supply / battery charger included with the meter. The batteries charge whether the meter is switched on or off. The Red LED on the meter will illuminate whenever the power supply / battery charger is attached and plugged into an 110VAC source. Warning: Use Only The Power Supply / Battery Charger Supplied With The Meter. Use Of Any Other Will Void Warranty and Can Cause Damage Or Injury. Quick Use Instructions To become familiar with the basic operation of the meter it is suggested that the user initially try the following: 1) Charge the batteries using the supplied power supply/charger unit. 2) Turn the meter on by pressing the On/Off key and check settings in the Set Up menu as described in Section 1. 3) Check and set the meter to read either CATV, VHF/UHF or Digital channels as follows: i) From any menu screen Press CLR then Press 2, then Press ENT. The display will show CH002 if the meter is set for CATV channels, CH02 for VHF/UHF channels or CH02 DIGITAL for Digital channels. To switch back and forth between the three, perform the following steps below, otherwise skip to step 4: ii) Press the On/Off key to turn the meter off iii) Press and hold the SCAN key while pressing the On/Off key iv) The meter will power on and switch between CATV, VHF/UHF or Digital channels. Repeating steps ii and iii will switch the selected channels again. 4) Carefully align the threads and connect the G-F81 type adapter to the RF Signal input port on the meter. Hand tighten until the adapter is fully seated. Over tightening the adapter with a tool can seriously damage the input port on the meter. 5) Connect the CATV or VHF/UHF signal source (cable line, antenna, etc) under test to the meter. 6) Press or to scroll through the available channels and note the measured video signal levels. 7) To switch and display the measured Audio level or V/A differential level values instead of the Video level, press the 0/2 nd F key and then press the 3/ V/A key. 3

MAIN USER INSTRUCTIONS 1 Meter Set-Up Features Each of the following set-up functions is activated by first pressing the 0/ 2 nd F key followed by the SET key. 1.1 AUTO OFF TIME The meter can be set to turn off after 5 minutes of inactivity or to remain on continuously. (The Meter is factory preset to the Always On setting) Press or to point to Auto Off Time. Press ENT key. 5 Minutes Off Always On Use or to choose the desired mode. Press ENT key. 1.2 AUDIO SET Enable or disable the speaker to monitor the audio while measuring audio carrier signal levels. Press or to point to Volume Set. Press ENT key. Audio On Audio Off Use or to choose the desired mode. Press ENT key. 1.3 LEVEL UNIT Select the desired measurement scale of dbµv or dbmv (Meter is factory preset to the dbmv measurement scale) Press or to point to Level Unit. Press ENT key. dbµv Disable dbmv Enable Use or to choose the desired mode. Press ENT key. 4

2 Selecting CATV, VHF/UHF of Digital Off-Air Channels The meter can be switched between CATV channels, VHF/UHF channels and Digital Off-Air Channels. To determine how the meter is currently configured or to make a change, do the following: From any menu screen Press CLR then Press 2, and then Press ENT. Check to see whether the displayed channel is CH002 (CATV), CH02 (VHF/UHF) or CH02 DIGITAL (Digital Off-Air). To switch back and forth between CATV, VHF/UHF of Digital channels, perform the following steps: i. Press the On/Off key to turn the meter off ii. Press and hold the SCAN key while pressing the On/Off key iii. The meter will turn turned back on and switch from CATV to VHF/UHF or Digital channels. Repeating steps i and ii will switch the selected channels again. 3 Configuring Channel Line Up The meter is factory programmed to read CATV channels 2-136, VHF/UHF channels 2-69 and Off-Air Digital Channels 2-69. Customized CATV, VHF/UHF and Digital channel plans within these ranges can also be saved in the User Plan mode. In order to select or edit the User Plan channels, the meter must first be set to the proper channel format (CATV, VHF/UHF or Digital). If you are unsure which channel format is currently selected or want to change the selection, refer to Section 2. 3.1 CHANNEL PLAN Select the factory programmed channel plan such as NTSC CATV or the custom User Plan Press the 0/2 nd F key and then the SET key. Press or to point to Channel Plan. Press ENT key. Use or to select the desired plan. Press ENT key. NTSC CATV User PLAN NTSC Channel Plan CATV or VHF/UHF OR Digital Off-Air Plan if the meter is set to Digital channels User defined Channel Plan 3.2 CHANNEL EDIT Specific channels can be included or removed from the User Plan. Press the 0/2 nd F key then the SET key. Press or to point to Channel Edit. Press ENT key. Use or to select the desired channel. Pressing SET will toggle the display between ON (including the channel in the plan) and OFF (eliminating the channel from the plan). Press or to move to the next channel. Press ENT key. Repeat the process with the SET key to toggle the channel ON/OFF setting CH02 ON Press SET Edit Select CH02 (ON) or don t select (OFF) Press key SET to edit 5

4 Meter Calibration This meter has been factory calibrated. The user can recalibrate each individual channel by connecting a CATV or VHF/UHF signal source with a known RF level to the meter input. The factory calibration of all channels can also be restored at any time. 4.1 CORRECT CH db (Calibration) Only functional for CATV and VHF/UHF Channels Adjust the displayed power level to match the input signal source level as follows: Press the 0/2 nd F key then the SET key. Press or to point to Correct CH db. Press ENT key. Use or to adjust the displayed LEVEL value to match the input signal source. Press SET to save the calibration. Press or and repeat for the next channel. CH to correct Video Carrier (V) Current correction (offset) value CH02V +0.0dB LEVEL 15.6dBmV CH02 Video Carrier modified value (offset) Measured Level value after modification The displayed CH02V is the channel to be modified. The displayed mode is the video carrier. The calibration adjustment is applied to both the video carrier and audio carrier readings. NOTE: User is not able to modify audio carrier calibration independently. Press CLR when all channel calibration changes have been completed 4.2 CLEAR CORRECT Restore to the factory preset calibration values. Press the 2 nd F key then the SET key. Press or to point to Clear Correct. Press ENT key. Clear Correct Press ENT NOTE: If you have entered this menu by error and do not want to restore the factory calibration values, press CLR key to escape the operation and return to testing mode Press ENT key again to confirm and restore the factory preset calibration values. This function will take a few seconds. All the modifications are cleared (correct value =0dB) 6

5 Scanning Channels Saving and Viewing Data Channels within the CATV, VHF/UHF or DIGITAL channel tables can be scanned and saved into one of the meter memory groups and then viewed at any time. Prior to scanning channels there are two set-up steps: 1 The meter should be set for either CATV, VHF/UHF or DIGITAL channels Refer to Section 2 2 The customized User Plan or the factory preprogrammed channel plan NTSC CATV or DIGITAL OFF-AIR should be selected - Refer to Section 3 5.1 SCANNING and SAVING DATA With the meter set to read the desired channel table, the designated channels can be scanned and saved into one of the memory groups. Press the 0/2 nd F key and then the SCAN key Scan No.00 Press,, ENT Scan groups NTSC VHF/UHF 1-6 NTSC CATV 7-12 ATSC Off-Air 13-18 Press or to select a storage location - Groups 01-06 (VHF/UHF) 7-12 (CATV) or 13-18 (Digital). After selecting the desired Group, press the ENT key to confirm. The meter will scan and save all channels. To escape from this operation, press the CLR key. Note: Data stored into any memory group during automatic scanning can be overwritten by running automatic scanning again. 5.2 VIEWING STORED DATA Data measured and stored into a memory group during a SCAN operation can be viewed. Press the 0/2 nd F key. Press the LOAD key CH02 V LOAD01 LEVEL 18.7dBmV CH No. 2 Video from Group:01 Stored video carrier signal level Press the or key to select the memory group to display. Press the ENT key Press the or key to view all scanned channels. To escape press the CLR key. If no data is stored, No Channel Saved No Channel Level Stored (Meter will auto escape to channel measurement mode) 7

6 Measuring Signal Levels 6.1 SINGLE (NTSC) CHANNEL SIGNAL LEVEL MEASUREMENT - VIDEO, AUDIO or V/A (Select CATV or VHF/UHF channels first Section 2) Not functional for Digital channels Press the 0/2 nd F key. Press the V/A key to enter this measurement mode. To change between Video, Audio and V/A, press the 0/2 nd F key and then the V/A key. Press the or key to view desired channel. CH002V 55.25MHz LEVEL: 18.7dBmV CH002A LEVEL: 59.75MHz 5.0dBmV CH002V V/A: 55.25MHz 13.7 dbmv VIDEO Test Mode AUDIO Test Mode V/A Test Mode 6.2 SINGLE (ATSC) CHANNEL SIGNAL LEVEL MEASUREMENT (Select Digital Off-Air channels first Refer to Section 2) Press the 0/2 nd F key. Press the or keys to view desired channel or enter the channel number and press the ENT key. CH02 LEVEL: DIGITAL 18.7dBmV 6.3 FREQUENCY BASED SIGNAL LEVEL MEASUREMENT (NTSC only) (Select CATV or VHF/UHF channels first Refer to Section 2) To measure the signal level of a specific frequency between 46MHz and 870MHz Use the numerical keys and the CLR/. decimal point key to enter the desired frequency. Press the ENT key to confirm. FREQ 87.50MHz LEVEL: 10.0dBmV Selected Frequency Measured Signal Level 8

HOLLAND ELECTRONICS LLC LIMITED WARRANTY Holland Electronics LLC warrants that the product enclosed with this Limited Warranty statement will conform to the manufacturer s specifications and be free of defects in the workmanship and material for a period of one-year (1) from the date of original purchase. WARRANTY PROCEDURE: If the product appears to be defective contact Holland Electronics LLC at (805) 339-9060. We will analyze the problem and offer solutions to prevent removing the unit from service. If no solution is found, and the unit must be returned for repair, you will be issued a Return Authorization (RA) number. Holland Electronics LLC will, at its option, repair or replace the defective unit under warranty, without charge for parts or labor. This repair will be subject to charges if signs of tampering or misuse are detected. Incoming shipping costs will be the customer s responsibility. Returns will not be accepted without an RA number. The warranty and remedy provided above are exclusive and in lieu of all other express warranties and unless stated herein, any statements or representations made by any other person or firm are void. The duration of any implied warranties of merchantability or fitness for a particular purpose on this product shall be limited to the duration of the warranty set forth above. Except as provided in this written warranty, Holland Electronics LLC shall not be liable for any loss, inconvenience, damage, including direct, special, incidental, or consequential damages, resulting from the use or inability to use this product, whether resulting from breach of warranty or any legal theory. Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. The warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. To arrange for warranty service: Call Holland Electronics LLC (805) 339-9060 Return Address with appropriate Return Authorization Number: 2935 Golf Course Drive Ventura, CA 93003 9