OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

Similar documents
R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

INSTALLATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Cyclo Series. user manual. MartinArchitectural

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

Model 1421 Distribution Amplifier

Ticker. World Clock. World Clock. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor 125" 122"

Church Layout Medium Advanced

For Sales & Information, Call Toll Free: (888)

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

The Chan-L-Wire Pro Series Lighting Distribution

DIN Power Module - Phase Adaptive

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

HighBand 25. TrueNet Category 6 Solutions

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

ABB IEC International Pin and Sleeve

Automatic Test System AT-S + with STAR + Technology Features

HDBT Installation Guide

Technical Specifications

PAM-1840 Preamplifier Operation Manual

High performance circuit breakers

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Technical Specifications

Kramer Electronics, Ltd.

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Site Installation Model MP-8433

ICS Digital Menu. Installation Guide Version 1.1

Dell Wyse 5030 PCoIP Zero Client

Site Installation Model MP-8424

LED Backlight for Technics amplifiers

Distributed Design Series

ELECTRICAL SAFETY INSPECTION REPORT

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Installation Guide VL-MV10. Model No.

LED Driver Linear / area fixed output

110LP MOON Series. Phono Preamplifier. Owner s Manual

Small System Packages. Strand Dimming Systems

SQM40/41 Actuators for air and gas dampers

Modular Lube Lubrication Systems System Controls

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Identification - electrical services

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Touch Panel Display Module

Technical Specifications

By CHANNEL VISION. Flush Mount Amplifier A0350

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Small System Packages. Strand Dimming Systems

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Active UTP Transceiver Hub Installation Guide

PCR AUTOMATIC HEAT TREATMENT CONSOLE

IndyGo Facility Upgrades Project 35671EE

Label Applicator HERMA 400

120 V~ Feed-Through DIN Panels (and Accessories)

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

NewScope-7A Operating Manual

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Operating Instructions Dimmer for V Incandescent Lamps

TeSys circuit-breakers

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

PNP300 / PNP300UN / PNP350

PRELIMINARY Sunny Boy 240-US

Spectra Batten (Order code: LEDJ95)

SPECIFICATION NO Model 207 Automatic GTAW Welding System

guestlink PowerWave PW4A Panel and Wall-Mount Models Installation Guide AV69102-XXX-XXX

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.


I/A Series Hardware Fiber Optic LAN Converter

16 Amp Electronic 24 Hour/7 Day Time Controller

Power Injector 1520 Series

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

USER MANUAL Table of Contents

Installation Manual SaVi Note Underwater LED Light

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

Multi-Channel Passive Transceiver Hubs Installation Sheet

DLP200M 2 Relay Module for Heating and Cooling Plants

Brilliant indoor display solutions. Now ready for a close-up.

RT AUDIO RETRACTABLE CABLE

Transcription:

L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-8-00A. 86 SAFE 6") 08 0 6 PAGE OF (6 ( 80 ( 86 SAFE 6") 80 SAFE AND HINGES PLAN VIEW 86 6") 80 ( 6 6") 8 (6 FOR VARIOUS FASCIA CONFIGURATIONS AND CONSUMER ACCESS DIMENSIONS SEE PAGE OF POWER CORD 0 ( 0 (") (0 6") 6 ( 0 ( 6") ( 0 8 ( ( 8 (6 FILE NO. -606 REV. FRONT ELEVATION OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) ON PAGE OF ( 8 ( ") 666 (6 08 SAFE 0 6 SIDE ELEVATION

CONDUIT AND JUNCTION BOX REQUIREMENTS mm (") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 0mm ( SQ. X mm ( DEEP JUNCTI0N BOX (ALL BY OWNER'S E.C.). DIEBOLD TO PROVIDE FLAT COVER WITH TAMPER SWITCH. WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO ATM, OWNER'S E.C. TO RUN mm ( METAL CONDUIT FROM 0mm ( SQ. X mm ( DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. POWER REQUIREMENTS: THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW. 00- VAC (+6%, -0%) AT 0 (±%) Hz, SINGLE-PHASE 00- VAC (+6%, -0%) AT 60 (±%) Hz, SINGLE-PHASE 00-0 VAC (±0%) AT 0 (±%) Hz, SINGLE-PHASE 00-0 VAC (±0%) AT 60 (±%) Hz, SINGLE-PHASE OWNER'S E.C. TO RUN mm ( LIQUID TIGHT FLEX METAL CONDUIT OR mm ( RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE. mm ( METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 0mm ( SQ. X mm ( DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 0 ( OF SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS). OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH,8 (86") FROM SIDE OF UNIT. JUNCTION BOXES MUST BE LOCATED WITHIN 0mm ( OF CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. 00- VAC (+6%, -0%) SERVICE, DISCONNECT AT 0 AMPERES 00-0 VAC (±0%) SERVICE, DISCONNECT AT 0 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE POWER CONDITIONING TO PREVENT THE ATM FROM MALING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6000--. CONFIGURATION: PROCESSOR, SVD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL, 80mm THERMAL RECEIPT, IDM, HIGH AFD, AND POWER USAGE AND HEAT OUTPUT: POWER HEAT MACHINE STATUS USAGE OUTPUT IDLE (NO TRANSACTION) WATTS 0 BTU TRANSACTION (DISPENSE 8 WATTS 6 BTU OR BULK NOTE) IN PROGRESS RAPID PROCESSING WATTS 8 BTU TRANSACTION IN PROGRESS SIGNAL CABLE RUN CONSTRAINTS THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. SEPARATION FROM OTHER CABLES TYPE OF ELECTRICAL RUN BELOW KVA - KVA ABOVE KVA FLUORESCENT, NEON OR INCANDESCENT mm (") mm (") mm (") LIGHTING FIXTURES OPERATING ENVIRONMENT: SAFE LOCATION 0º C TO 8º C (0º F TO 00º F) WEIGHT OF UNITS: CEN III - 0kg (,800 LBS.) CEN IV - kg (,80 LBS.) RELATIVE HUMIDITY (NON-CONDENSING) 0 TO 80% AT º C (0º F), 0 TO % AT 8º C (00º F) UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT mm (") 0mm ('-0") 60mm ('-0") 6mm ( ") mm (6") 0mm ('-0") CAUTION LABEL POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT 0mm ( 6") 6mm (") mm (6") SIGNAL CABLE INSTALLATION CONSTRAINTS: RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. PAGE OF (0 6") 8 ( ") ( 8 ( ") ( ( 0 68 (6 0 ( 6") 0 6 ( 8 ( FILE NO. -606 REV. 86 SAFE 6") REAR ELEVATION SIDE ELEVATION

EQUIRED MINIMUM SERVICE AREA NO. -606 REV. PAGE OF RFILE (8 REQUIRED MINIMUM SERVICE AREA ALL ELECTRICAL AND DATA CABLES MUST ENTER UNIT IN THIS AREA (") SAFE 08 0 (6") 066 6") 6") 6 ( SHOWN IS THE REQUIRED MINIMUM AREA FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. (6 6") 86 SAFE 6") 8 (0 6") (6 ( 6 (") 6 ( 0 6") 06 ( 6") PLAN VIEW - REQUIRED MINIMUM SERVICE AREA 60 6") ( (6") 6") (8 86 600 (0 ( (0 6")

86 SAFE 6") ( (8 ( CABLE ENTRY OPENING (SEE NOTE) 8 ") SAFE 08 0 80 6") ( ( 08 0 FILE NO. -606 REV. 8 6") 8 ( ( 08 6") ( ( 0 6") ( 6") 86 6") ( 6") ( PLAN/SECTION - SAFE FLOOR ANCHORING HOLES SNAP-OFF DETECTOR ) mm ( RECESS DIAMETER mm ( RECESS mm (") THROUGH-HOLE-DIAMETER () 6mm ( 6") RECESS DIAMETER mm (") RECESS mm ( THROUGH-HOLE-DIAMETER PAGE OF NOTES: FOR ADDED SECURITY: THE TERMINAL SAFE MUST BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES FOR ANCHORING THE TERMINAL. ANCHORING THE TERMINAL TO CONCRETE FLOORS: WHEN ANCHORING THE TERMINAL, IT IS REQUIRED THAT THE TERMINAL BE ANCHORED TO CONCRETE FLOOR. DIEBOLD RECOMMENDS USING A M0 OR mm ( ANCHOR BOLT THAT IS 0mm ( LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 0mm ( THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. CABLE ENTRY ELECTRICAL AND DATA CABLING ENTERS THE TERMINAL THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE TERMINAL PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING ENTERS FROM THE SIDE OF THE TERMINAL. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE TERMINAL. mm ( DIA. HOLE FOR ALARM CABLES (SIDE ENTRY) POWER CABLE PLATE OPENING FOR POWER CORD AND DATA CABLES (SIDE ENTRY)

CONSUMER ACCESS DIMENSIONS TOP OF TOUCH SCREEN TOP KEY COIN DOOR BAR CODE SCANNER TOP OF TOUCH SCREEN TOP KEY (0 6") 8 ( 6 6") (8 08 6") RECEIPT 0 (8 6") KEYPAD (MIDDLE EPP KEY) RECEIPT ( 6") 8 ( 88 6") 0 6") KEYPAD (MIDDLE EPP KEY) 80 0 ( 6") ADVANCED DISPENSER ( ( 6") CARD READER IDMbd LOWER ADVANCED DISPENSER (6 ") IDMbd LOWER 6 (6 6") CARD READER ( 6") 8 ( BAR CODE SCANNER COIN DOOR 06 6") 6 (6 6") 6") 6 (6 6") - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL PAGE OF TOP OF TOUCH SCREEN TOP KEY - FROM BOTTOM OF SAFE TOP OF TOUCH SCREEN TOP KEY PASSBOOK KEYPAD (MIDDLE EPP KEY) (0 6") 8 ( 6 6") (8 08 6") 0 (8 6") PASSBOOK ( 6") 8 ( - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL 88 6") 0 6") KEYPAD (MIDDLE EPP 80 KEY) IDM V UPPER 0 ( 6") ADVANCED DISPENSER ( ( 6") IDMbd UPPER BAR CODE SCANNER CARD READER RECEIPT ADVANCED DISPENSER RECEIPT (6 6 (6 6") CARD READER ( ") 6 (6 6") BAR CODE SCANNER 06 6") 6 (6 6") ") IDMbd UPPER IDM V LOWER 6 (6 6") FILE NO. -606 REV. (6 ") IDM V LOWER 6 (6 6") IDM V UPPER ") 6 (6 6") - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL