L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-8-00A. 86 SAFE 6") 08 0 6 PAGE OF (6 ( 80 ( 86 SAFE 6") 80 SAFE AND HINGES PLAN VIEW 86 6") 80 ( 6 6") 8 (6 FOR VARIOUS FASCIA CONFIGURATIONS AND CONSUMER ACCESS DIMENSIONS SEE PAGE OF POWER CORD 0 ( 0 (") (0 6") 6 ( 0 ( 6") ( 0 8 ( ( 8 (6 FILE NO. -606 REV. FRONT ELEVATION OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) ON PAGE OF ( 8 ( ") 666 (6 08 SAFE 0 6 SIDE ELEVATION
CONDUIT AND JUNCTION BOX REQUIREMENTS mm (") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 0mm ( SQ. X mm ( DEEP JUNCTI0N BOX (ALL BY OWNER'S E.C.). DIEBOLD TO PROVIDE FLAT COVER WITH TAMPER SWITCH. WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO ATM, OWNER'S E.C. TO RUN mm ( METAL CONDUIT FROM 0mm ( SQ. X mm ( DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. POWER REQUIREMENTS: THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW. 00- VAC (+6%, -0%) AT 0 (±%) Hz, SINGLE-PHASE 00- VAC (+6%, -0%) AT 60 (±%) Hz, SINGLE-PHASE 00-0 VAC (±0%) AT 0 (±%) Hz, SINGLE-PHASE 00-0 VAC (±0%) AT 60 (±%) Hz, SINGLE-PHASE OWNER'S E.C. TO RUN mm ( LIQUID TIGHT FLEX METAL CONDUIT OR mm ( RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE. mm ( METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 0mm ( SQ. X mm ( DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 0 ( OF SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS). OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH,8 (86") FROM SIDE OF UNIT. JUNCTION BOXES MUST BE LOCATED WITHIN 0mm ( OF CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. 00- VAC (+6%, -0%) SERVICE, DISCONNECT AT 0 AMPERES 00-0 VAC (±0%) SERVICE, DISCONNECT AT 0 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE POWER CONDITIONING TO PREVENT THE ATM FROM MALING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6000--. CONFIGURATION: PROCESSOR, SVD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL, 80mm THERMAL RECEIPT, IDM, HIGH AFD, AND POWER USAGE AND HEAT OUTPUT: POWER HEAT MACHINE STATUS USAGE OUTPUT IDLE (NO TRANSACTION) WATTS 0 BTU TRANSACTION (DISPENSE 8 WATTS 6 BTU OR BULK NOTE) IN PROGRESS RAPID PROCESSING WATTS 8 BTU TRANSACTION IN PROGRESS SIGNAL CABLE RUN CONSTRAINTS THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. SEPARATION FROM OTHER CABLES TYPE OF ELECTRICAL RUN BELOW KVA - KVA ABOVE KVA FLUORESCENT, NEON OR INCANDESCENT mm (") mm (") mm (") LIGHTING FIXTURES OPERATING ENVIRONMENT: SAFE LOCATION 0º C TO 8º C (0º F TO 00º F) WEIGHT OF UNITS: CEN III - 0kg (,800 LBS.) CEN IV - kg (,80 LBS.) RELATIVE HUMIDITY (NON-CONDENSING) 0 TO 80% AT º C (0º F), 0 TO % AT 8º C (00º F) UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT mm (") 0mm ('-0") 60mm ('-0") 6mm ( ") mm (6") 0mm ('-0") CAUTION LABEL POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT 0mm ( 6") 6mm (") mm (6") SIGNAL CABLE INSTALLATION CONSTRAINTS: RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. PAGE OF (0 6") 8 ( ") ( 8 ( ") ( ( 0 68 (6 0 ( 6") 0 6 ( 8 ( FILE NO. -606 REV. 86 SAFE 6") REAR ELEVATION SIDE ELEVATION
EQUIRED MINIMUM SERVICE AREA NO. -606 REV. PAGE OF RFILE (8 REQUIRED MINIMUM SERVICE AREA ALL ELECTRICAL AND DATA CABLES MUST ENTER UNIT IN THIS AREA (") SAFE 08 0 (6") 066 6") 6") 6 ( SHOWN IS THE REQUIRED MINIMUM AREA FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. (6 6") 86 SAFE 6") 8 (0 6") (6 ( 6 (") 6 ( 0 6") 06 ( 6") PLAN VIEW - REQUIRED MINIMUM SERVICE AREA 60 6") ( (6") 6") (8 86 600 (0 ( (0 6")
86 SAFE 6") ( (8 ( CABLE ENTRY OPENING (SEE NOTE) 8 ") SAFE 08 0 80 6") ( ( 08 0 FILE NO. -606 REV. 8 6") 8 ( ( 08 6") ( ( 0 6") ( 6") 86 6") ( 6") ( PLAN/SECTION - SAFE FLOOR ANCHORING HOLES SNAP-OFF DETECTOR ) mm ( RECESS DIAMETER mm ( RECESS mm (") THROUGH-HOLE-DIAMETER () 6mm ( 6") RECESS DIAMETER mm (") RECESS mm ( THROUGH-HOLE-DIAMETER PAGE OF NOTES: FOR ADDED SECURITY: THE TERMINAL SAFE MUST BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES FOR ANCHORING THE TERMINAL. ANCHORING THE TERMINAL TO CONCRETE FLOORS: WHEN ANCHORING THE TERMINAL, IT IS REQUIRED THAT THE TERMINAL BE ANCHORED TO CONCRETE FLOOR. DIEBOLD RECOMMENDS USING A M0 OR mm ( ANCHOR BOLT THAT IS 0mm ( LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 0mm ( THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. CABLE ENTRY ELECTRICAL AND DATA CABLING ENTERS THE TERMINAL THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE TERMINAL PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING ENTERS FROM THE SIDE OF THE TERMINAL. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE TERMINAL. mm ( DIA. HOLE FOR ALARM CABLES (SIDE ENTRY) POWER CABLE PLATE OPENING FOR POWER CORD AND DATA CABLES (SIDE ENTRY)
CONSUMER ACCESS DIMENSIONS TOP OF TOUCH SCREEN TOP KEY COIN DOOR BAR CODE SCANNER TOP OF TOUCH SCREEN TOP KEY (0 6") 8 ( 6 6") (8 08 6") RECEIPT 0 (8 6") KEYPAD (MIDDLE EPP KEY) RECEIPT ( 6") 8 ( 88 6") 0 6") KEYPAD (MIDDLE EPP KEY) 80 0 ( 6") ADVANCED DISPENSER ( ( 6") CARD READER IDMbd LOWER ADVANCED DISPENSER (6 ") IDMbd LOWER 6 (6 6") CARD READER ( 6") 8 ( BAR CODE SCANNER COIN DOOR 06 6") 6 (6 6") 6") 6 (6 6") - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL PAGE OF TOP OF TOUCH SCREEN TOP KEY - FROM BOTTOM OF SAFE TOP OF TOUCH SCREEN TOP KEY PASSBOOK KEYPAD (MIDDLE EPP KEY) (0 6") 8 ( 6 6") (8 08 6") 0 (8 6") PASSBOOK ( 6") 8 ( - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL 88 6") 0 6") KEYPAD (MIDDLE EPP 80 KEY) IDM V UPPER 0 ( 6") ADVANCED DISPENSER ( ( 6") IDMbd UPPER BAR CODE SCANNER CARD READER RECEIPT ADVANCED DISPENSER RECEIPT (6 6 (6 6") CARD READER ( ") 6 (6 6") BAR CODE SCANNER 06 6") 6 (6 6") ") IDMbd UPPER IDM V LOWER 6 (6 6") FILE NO. -606 REV. (6 ") IDM V LOWER 6 (6 6") IDM V UPPER ") 6 (6 6") - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL