T8 LED Tube Light AL-L06-CF

Similar documents
T8 LED Tube. UL-Lighting. Features. Certificates. Web:

SubstiTUBE Value EM Fighter Tube Technical Datasheet

Figure 1. High Efficiency T8 LED Tube. Figure 3. Full View of Light High Efficiency T8 LED Tube

S PECIFICATION. Foshan NationStar Optoelectronics Co.,Ltd. LED Lighting Branch. T8 LED light tube NS-T8-4XX18-BXX(1T) Date Version V1.

PLCC W CRI K Datasheet

PLCC W 6000K Series Datasheet

PLCC W CRI 80 Datasheet

PLCC W LC CRI80 Datasheet

Filament Series Flexible Filament

PLCC W CRI90 Datasheet

PLCC W 2 Series IEC White Datasheet

PLCC 5630B 0.5W High CRI Datasheet

EdiPower II HM Series Datasheet

Flexible Filament Bulb ST64_4W Golden Datasheet

HALOLUX CERAM. Product family datasheet. Compact halogen lamps for use in narrow luminaires

Philips Corepro LEDtube T8

EdiPower II HM Series (PAR) Datasheet

17W AR111 Module Datasheet

Bulb Down Light Decorative Light

Features. High Brightness SMD LED Light source

V. PLCC Series. Datasheet. Introduction : Description : Feature and Benefits : PLCC Series

Cove Light AC DIM GII

Classic and advanced T8 LED tubes

PLCC Series W. Datasheet. Introduction : Feature and Benefits : Description : PLCC Series

3528 1W 2 Series White (IP)

LED SUPERSTAR CLASSIC B 25 ADV 4 W/827 E14

3528 1W 3 Series White

R xx-C0900-J074

ET-5050x-BF1W Datasheet

PLCC Series 5630B HE High CRI

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

PLCC Series 2835 SE PCT

W LC Datasheet

PRODUCT FAMILY DATASHEET HALOGEN CLASSIC B

LED SUPERSTAR CLASSIC A 60 DIM 9 W/827 E27 FR

PARATHOM CLASSIC A 75 ADV 13.5 W/827 E27

PLCC S Series W 9V

SubstiTUBE Value ST8-HV5

Guidelines for Specification of LED Lighting Products 2010

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED

LEDVANCE DOWNLIGHT LED

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

Product datasheet. PARATHOM R50 LED reflector lamps R50 with retrofit screw base. Areas of application. Product benefits.

Caveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.

Efficiency Meets Lighting Quality LG LED Downlight

SubstiTUBE Value EM ST8V-1.2m-17W-EM

SubstiTUBE Value ST8V-0.6m

Evaluating and Specifying LED Lighting

Affordable Performance.

Federal 3535 FX-C White Datasheet

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED

HM CRI80 Series. EdiPower III. Datasheet

HM CRI90 Series. EdiPower III. Datasheet

Remote LightBar Series Datasheet

OSRAM DULUX PRO MICRO TWIST

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

Liner Quattro AC XB RGBW

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

Features. Typical Applications

YJ-BC-3030-G01 High CRI LED

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

EdiPower II CAC Series Datasheet

PARATHOM PAR ADV 5.5 W/827 GU10

PRODUCT FAMILY DATASHEET LEDVANCE SPOTLIGHT LED PRO

OLED light is simple, pure, and honest. We can feel its presence and appreciate the light itself.

PARATHOM PRO MR ADV 4.4 W/940 GU5.3

T5 LED Integrated Lamp

Affordable Performance.

Philips InstantFit LED PL-C/T Lamp

OSRAM DULUX PRO MICRO TWIST

PARATHOM PRO AR W/ V G53

EdiPower II Series. Features LED light engine High power operation Instant on Long lifetime. Copyright 2010 Edison Opto. All rights reserved.

PARATHOM PRO AR W/ V G53

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED FIREPROOF

PLCC 2835 HE Series Datasheet

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NEXT GENERATION REMOTE PHOSPHOR LED LIGHTING SOLUTIONS

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

5W MR16 LED Lamp Datasheet

PARATHOM PRO MR ADV 5 W/927 GU5.3

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

PARATHOM MR ADV 6.5 W/830 GU5.3

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

YJ-BC-2835L-G02 High CRI LED

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

HALOGEN CLASSIC A. Product family datasheet. Halogen lamps, classic bulb shape

The most cost-effective full window design delivering uniform light

Decorative lighting. Decorative Light

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Preliminary Data sheet

LED. no compromise. cold phosphor collection 2011

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

L xxx-C0720-K255

Report of Test LLIA

LED PHONO SOLAR TECHNOLOGY CO., LTD.

EDIS Circular Module Datasheet

Technical operating data

EdiPower III SL Series

YJ-VTC-2835-G01 High CRI LED

R Rxx-Vxxxx-L334-x

Transcription:

AOD LED tube light is an environment-friendly semiconductor light which possesses a number of advantages over the conventional ones such as no flashing, comfortable light and high color-rendering index that are favorable for the user s eyesight and physical health. With general-standard design of the structure, AOD T5 LED tube light is applicable for installation in recessed ceiling luminaire like T5 Grille Lamp, and widely used in the common interior lighting places for directly replacing the conventional T5 fluorescent tube light. Characteristics Energy saving: Compared with the conventional fluorescent light, the energy saving rate is over 60% under the same illumination. Eco-friendly: No UV or IR, no mercury or other harmful materials. Long Lifetime: 50000hrs to 80000hrs, 10 times longer than the conventional fluorescent tube light. High Luminous efficacy: using the high luminous efficacy and high reliability SMD light source. Easy to install: totally matching with the fixture of the conventional fluorescent tube light. Recommended Applications AOD T5 LED tube lights are suitable for many kinds of applications, such as the general illumination for homes, offices, restaurants, hotels, meeting rooms, factories, malls, supermarkets, underground garages, warehouses, parking lots, subway stations etc., almost anywhere you need general indoor lighting. Product Categories Part No. LED Power Working Voltage of External Power Supply(EPS) Tube Quantity Driven by per EPS Weight Lamp Base/ Tube Diameter (1T1) 85~265VAC 1 piece (1T2) 6W 85~265VAC 2 pieces 75±10g (1T3) 85~265VAC 3 pieces AL-L09-CF(1T1) 85~265VAC 1 piece 9W 105±10g AL-L09-CF(1T2) 85~265VAC 2 pieces AL-L12-CF(1T1) 85~265VAC 1 piece 12W 190±10g AL-L12-CF(1T2) 85~265VAC 2 pieces For more product details, please visit us at www.aodevices.com - 1 -

Technical Specifications Item (1T1) (1T2) (1T3) Text Conditions Notes Working Voltage of EPS (V) Tube Quantity Driven by per EPS AC 85~265 1 piece 2 pieces 3 pieces Working Frequency(Hz) 50~60 LED Power(W) 6.0±0.5 12.0±1.5 18.0±2.0 AC220V,25 Input Power(W) 7.0±1.0 14.0±1.5 21.0±2.0 AC220V,25 Power Factor 0.90 AC220V,25 Luminous Flux(lm) (Typ.) CRI 565 1130 1695 CCT:6300±200K 75~80 CCT(K) 2700~6500 Optional 1 Working Temperature ( ) -20~45 AC220V Lifespan(hrs) 50000 AC220V,25 Weight(g) 75±10 Affected by operation environment Net weight per piece Dimensions Interface/Diam. L549 D16mm G5 / T5 Note: The CCT range of AOD LED tube lights: 2700±150K, 3000±180K, 3500±200K, 4000±250K, 4500±250K, 5000±300K, 5700±300K, 6500±500K. Lumen Depreciation Chart Note: This chart shows the actual test data, which clearly reflects the lumen depreciation of AOD LED tube light. These data were obtained through the test samples worked at 220VAC at the general room temperature and lighted constantly in a long-term. Observers measured the luminous flux, luminous efficiency and other parameters once a month. - 2 -

Illuminance Diagram Lighting area and the average illuminance under different projection distance Illuminance Diagram for Note: Tested in standard Distribution Photometer laboratory (full dark background). Distance between the LED Tube Lights and detector is 9.0m; CCT: 6300±200K and Ra:80~75 for the sample tested. Dimensions A B C D 549 mm 556.5 mm 564 mm 16.2 mm - 3 -

Package Packed in carton, which is divided into 4 layers with 5 pieces per layer, totally 20 pieces LED tubes per carton. The bottom and top of the carton and the space between layers are fixed and protected by foam pads. Installation Guide Recommended installation steps: 1. Remove the ballast and the starter of from the T5 Grille Lamp fixture. 2. Install and fix with screw the external power supply (EPS) of T5 LED tube light into the T5 Grille Lamp fixture. 3. Connect the wires according to the guide below (Please pay attention to the + and - marks). 4. Turn on the switch to light the tube. Note: 1. Introduction of T5 Grille Lamp fixture: Type Dimension of the Lamp fixture (L W) Ceiling scuttle T5 LED Tube Light Quantity of light tubes per Lamp fixture 600 200 T5 Grille Lamp fixture 598mm 180mm 585mm 170mm (1T1) 1 piece 600 300 T5 Grille Lamp fixture 598mm 298mm 585mm 285mm (1T2) 2 pieces 600 600 T5 Grille Lamp fixture 598mm 598mm 585mm 585mm (1T3) 3 pieces 600 600 T5 Grille Lamp fixture 598mm 598mm 585mm 585mm (1T2) 4 pieces 2. Introduction of External Power Supply(EPS): Type Dimension (L W H) T5 LED tube light Matched T5 EPS(06)-one diver for one tube 153mm 40mm 30mm (1T1) T5 EPS(06)-one diver for two tubes 153mm 40mm 30mm (1T2) T5 EPS(06)-one diver for three tubes 153mm 40mm 30mm (1T3) Note:The distance between the installing holes of EPS is 142mm. M4 screws should be used for fix the EPS into the Lamp fixture. - 4 -

Schematic wiring diagram Diagram for T5 Grille Lamp fixture (Double tubes) Diagram for T5 Grille Lamp fixture (Three tubes) Attention: 1. The tube light should be firmly fixed. 2. The connection of the wires should be done by professional electricians referring to the installation guide to avoid dangers. 3. The operating voltage cannot exceed the specified range (85~265VAC). 4. Disassembly of the light without permission is forbidden. For any problem please contact our service department. - 5 -

After-sale service If you have any questions or problems in the process of unpacking, installation and use, please contact our Customer Service Department. We will respond within 2 hours, and if necessary, we will promptly send our maintenance professionals to reach your site as quickly as possible to solve your trouble and restore to the normal working condition. AOD takes guarantee responsibility unless otherwise specified in the following circumstances: The breakdown or the damage is caused by incorrect installation, failure operation or use under the Not- specified working conditions. The damage is caused by accident, abuse or misuse. The breakdown or the damage is caused by customers unsuitable safekeeping or transportation. The breakdown or the damage is caused by customers disassembly or changing the spare parts to which are not approved by AOD. The breakdown or the damage is caused by man-made or natural disaster. Customer Service Center:+86-536-2221111 AOD will constantly improve our production performance and insist on innovation. The information contained in this document is the lately data at the deadline for edition and subject to change without notice. AOD reserves the right to the interpretation of this document. The pictures shown here is indicative only. If there is inconsistency between the pictures and the actual product, the actual product shall govern. - 6 -