6LE-AURA-REM-CT 6" APERTURE REMODEL DIRECT LED RECESSED DOWNLIGHT COLOR TUNING

Similar documents
PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

SERIES 6LCDB79V Lensed Low Voltage LED

SERIES 6VLFL2X Lensed LED Downlight Lumen Flex

VIA 1.5 LED PENDANT DIRECT W W W. L U M E N W E R X. C O M

VIA 3 - PATTERNS PENDANT DIRECT W W W. L U M E N W E R X. C O M

VIA 3 LED RECESSED WALL WASH V. 2 W W W. L U M E N W E R X. C O M

ESA Series ESA LED Architectural Downlight Round 8" Aperature 28, 42 & 56 LEDs

PENDANT MOUNT - DIRECT/INDIRECT

VIA 2 LED WALL INDIRECT ASYMMETRIC V. 2 W W W. L U M E N W E R X. C O M

FINELITE. 10 Year LED Warranty. High Performance 4" Aperture (HP-4) - Indirect/Direct

XML LED X M L L E D. Explosionproof Linear LED Lighting

Lumencove Family. The highest quality light from the tightest spaces

PILOT COVE INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT

LINEAR DOWNLIGHT - PENDANT DIRECT

4" Round A4VOFLED Open Downlight A4VEFLED Lensed Downlight AIC4VOFLED IC-Rated, Open Downlight AIC4VEFLED IC-Rated, Lensed Downlight

RL639 NEW 90+ CRI RGB/W COLOR QUALITY. 800 Lumens LUMEN OUTPUT 13W WATT. LUMEN PER WATT Up to 60. Tunable (50K-27K) CCT.

FEATURES. Output 30 W Light Engine CCT, CRI Lumen Output Efficacy Peak Intensity

Seem 2. Individual units and continuous runs in 1" increments. Frosted acrylic lens provides uninterrupted illumination, without pixels or shadows.

M100 My White LED Indirect

Seem 2. Preferred Light: Lighting for better color rendition and human preference. LED PERFORMANCE MOUNTING INFORMATION. recessed companion

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

MODO. Bellini, large. pendant PROJECT SPECIFICATIONS ORDERING LOGIC. Job. Notes. Type. Part #

*98 CRI not available *w/ 20, 40, 60 in 2000lm reflectors only RS##=Rigid Stem

LED MODULES READYLINE DL

CR Series LED Downlights Easy to Install with Unprecedented Payback

CR Series LED Downlights. Easy to Install with Unprecedented Payback THE QUALITY YOU DEMAND WITH THE SAVINGS YOU DESERVE.

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

Efficiency Meets Lighting Quality LG LED Downlight

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

Linealux L5 Linear Facade

TOKISTAR. TokiLux TOKISTAR LIGHTING

CHALICE PENDANT LED DOWNLIGHT 70 Watt LED

FIXTURE WATTAGE (TOTAL WATTAGE)

2000 LUMENS IC RATED FUSION ER3 IC SERIES LED DOWNLIGHT LED ER3 FLANGED OR TRIM-LESS RECESSED WITH TOOL-LESS ADJUSTABILITY

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

Liner Quattro AC XB RGBW

LUNERA SERIES L7 _ GEN 3

ALPHA2 2 LED DOWNLIGHT SERIES

Model Material Lamp type LED color Voltage Distribution Lens

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

SPECIFICATION SHEET lumencove

KRONA-IV Recessed LED Downlight

Altman Lighting Spectra Cyc 50 Specification

Features. High Brightness SMD LED Light source

Pendant Downlight Aircraft Cable Uplight Aircraft Cable Downlight Hinge Mount Fixed Mount. Remote Power Supply. FIXTURE WATTAGE 6.0 W/ft 12.

Nemesis. Family of Low Glare Downlights CFL Equivalence. CFL equivalence outputs. Low glare UGR19 reflector

architecture mounting Features Product lighting

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

PILOT TM PGM INTERIOR WALL GRAZING

R Rxx-Vxxxx-L334-x


CLD Series. CLD LED Surface Luminaire

PILOT COVE INTERIOR - INTEGRAL POWER SUPPLY ACTIVE WHITE (TUNABLE)

17W AR111 Module Datasheet

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

Rail 4 RM4D (Formerly Grande) LED. Wall

R xx-C0900-J074

PARĀTA. 724 RGB LED Linear Cove. Introduction. Specifications. Ordering Information

Introduction 700ADJ2 - Adjustable Mount. 700ADJ2 Mount. Linear Plan MSL1 MSL2 MSL3 MSL4

DUCAT-IV Adjustable Aim Recessed LED Downlight

FEAT U RES : Slightly recessed beveled lens housing 2700K 3000K 3500K 4000K 5000K. 385 lumens/ft. (4w/ft.) 760 lumens/ft. (8w/ft.

FLUID VIEW 12V LED TAPE LIGHT

JUNO RECESSED LED DOWNLIGHTS

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

PL PROFILE 1 MKII LED

CHALICE PENDANT LED DOWNLIGHT 150 Watt LED

RKDISE LED. LED Center Basket Retrofit Kit EXAMPLE: RKDISE24-LED48FRDMV WATT CAT# APPLICATIONS FEATURES & BENEFITS

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

RGB+W RGBWWA. TOTAL POWER CONSUMPTION 6.0 W/ft 12.0 W/ft. FIXTURE WATTAGE 6.0 W/ft 12.0 W/ft

Evaluating and Specifying LED Lighting

Altman Lighting AP-150 RGBW Par Specification

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Preliminary Data sheet

L xxx-C0720-K255

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

DESIGNED FOR AUSTRALIA AND NEW ZEALAND THE ORANGETEK TERRALED MINI ROAD LIGHT

PrimaLine 1.5 XT Wet Location LED Tape Light

araya Light Commissioning Tool Operation Guide DISCONTINUED - NO LONGER AVAILABLE

Series 16 LED. Performance. Flexibility Effi cacy Aff ordability. Indirect/Direct Luminaires. Year. Year

*To meet 1000kg walk over resistance requirements, cement must support 100% of the exterior surfaces of the blockout.

AR-111 LED LED. LED Lamp for Arte-AR-111 Trac Fixture

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Small System Packages. Strand Dimming Systems

BLANCA BLS727W White LED Linear Surface

Woda W7 Underwater Spotlight

PRISM Smart LED RGBW Retrofit Downlight

LED Driver Compact dimming

COLORBLAST 12 POWERCORE

WLB92 Industrial LED Light Bar (AC Conduit)

TROV TROUBLE SHOOTING GUIDE. A comprehensive trouble shooting guide for TROV

ARCSYSTEM. Fully-dimmable LED lighting for auditoriums, retail and commercial installations. visual environment technologies etcconnect.

LUXPOINT TM MIDI 6 LED Downlight Data Sheet

PowPak Dimming Module with 0 10 V- Control

LUXFLEX FLEXIBLE, COLORFUL BACKLIGHTING

TruLine 1A 24VDC - BUILD-IT-YOURSELF PLASTER-IN LED SYSTEM

Small System Packages. Strand Dimming Systems

Cove Light AC DIM GII

iw Cove Powercore Compact, intelligent white cove light for brilliantly illuminating interior spaces

Transcription:

6LE-AURA-REM-CT 6" APERTURE REMODEL DIRECT LED RECESSED DOWNLIGHT COLOR TUNING Clarus AURA series LED products feature araya LED Modules by Lumenetix. PERFORMANCE CHARACTERISTICS DISTRIBUTION: 100% Down / 0% Up FIXTURE EFFICIENCY: 96% MODEL LUMENS WATTS LM/W 6LE-AURA-REM-CT 2000 32.0 62 6LE-AURA-REM-CT 1200 20.0 60 6LE-AURA-REM-CT 800 12.5 64 Clarus AURA series fixtures feature a wide range of color and dimming controls. 15.59 14.50 6.49 Features include: 10.00 13.00 Lumenetix araya5 Tuneable LED Technology Tuneable White Light with settable Color Temperatures and Color Saturation 6.50 Output up to 2000 lumens CRI and R9 values >90CRI Multiple beam spread options 6.09 6.70 Multiple reflector color options Control Protocol Options - 0-10v, DMX, Bluetooth via IOS App for ipad or iphone, Lutron Ecosystem 0.50 MIN 7.25 9.00 Fixture configuration and options chosen may have an affect on fixture dimensions. Consult factory if installing in a restricted space. FIXTURE TYPE: -- MODEL NO: -- PROJECT: -- NOTES:

MODEL No.: 6LE-AURA-REM ---- - - R - CT- -- 1 --- -- --- -- -- -- -- - - - - - - - - - 6LE-AURA-REM SERIES LUMEN MOUNTING 08 (800 Lumen) 12 (1200 Lumen) 20 (2000 Lumen) R (Recessed) 6LE-AURA WITH CT - CT DESIGNATES THAT THE LED LIGHT OUTPUT CAN BE COLOR TUNED ACCOMPLISHING A COUPLE DIFFERENT DESIRED OUTCOMES. 1. THE WHITE LIGHT OUTPUT CAN BE ADJUSTED IN COLOR TEMPERATURE FROM WARM TEMPERATURES OF 1650K UP TO COOL TEMPERATURES OF 4000K. 2. COLOR SATURATIONS CAN BE ALTERED CHANGING THE LIGHT OUTPUT FROM "WHITE" TO ANY COLOR OF THE SPECTRUM. FIXTURES MAY BE PROGRAMMED WITH UP TO 5 PRESET SCENES WHICH CAN BE RECALLED VIA SIMPLE 0-10V CONTROLS (BY OTHERS). WITH PROPER DMX CONTROL SYSTEMS (BY OTHERS) IT IS POSSIBLE TO SET FIXTURES WITH CT TO CONSTANTLY COLOR CHANGE THRU THE RANGE OF COLORS FOR DYNAMIC ACCENT LIGHTING. BEAM SPREAD 20 20 BEAM 40 40 BEAM 60 60 BEAM CIRCUIT SETUP CONTROL 1 C (Commissioning Tool Setup) I (ios App Setup via Bluetooth) CX (Commissioning Tool Setup with DMX capabilities) IX (ios App Setup via Bluetooth with DMX capabilities) CE (Commissioning Tool Setup with Lutron EcoSystem capabilities) IE (ios App Setup via Bluetooth with Lutron EcoSystem capabilities) VOLTAGE REFLECTOR DIFFUSER COLOR EMERGENCY ELECTRICAL OPTIONS 1 (120v) 2 (277v) 3 (347v)** H (Haze) C* (Champagne) G* (Gold) M* (Gun Metal) P* (Pewter) S* (Straw) U* (Umber) T* (Wheat) B (Black Paint) W (White Paint) - (None) SOL (Frosted Solite Regressed Lens) - (None) G (GLR Fuse) * Anodized reflector colors available (consult factory) but may affect the color of the light output. PMC recommends selecting neutral tone reflectors on AURA series fixtures. ** 347v uses an on-board step down transformer SEE WIRING DIAGRAMS ON FOLLOWING PAGES FOR VARIOUS SETUP AND CONTROL OPTIONS. SOME OPTIONS MAY NOT BE AVAILABLE IN COMBINATIONS - ALL FIXTURE COFIGURATIONS SUBJECT TO FINAL FACTORY APPROVAL PRODUCT SPECIFICATION DATA: Clarus AURA series fixtures powered by Lumenetix araya5 tunable LED technology featuring a wide range of color and dimming options. Up to 1200lm output, 90+ CRI standard. 20, 40 and 60 beam spread options available. Low irridescent Alzak reflector. Trim flange to match reflector finish is standard. Matte white trim or other colors available - consult factory. Capable of mounting in a 2" thick ceiling. Integral heat sink (extruded aluminum) provides minimum 70% lumen maintenance at 50,000 hours. 14 ga galvanized junction box with toolless covers. Suitable for through wiring (4in/4out) #12 AWG. Fixture should be installed in applications where ambient temperatures do not exceed 50 C. Factory wired for ease in installation. LED Driver accessible from below ceiling. Fixtures are ETL/cETL listed for damp location, and have standard electronic drivers. Each fixture is tested at the factory before shipment. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CLARUS SERIES LED FIXTURES CARRY A LIMITED 5 YEAR WARRANTY. INSTALLATION: 1. MAKE FEED WIRE CONNECTIONS TO FIXTURE FROM POWER SOURCE INSIDE JUNCTION BOX AND PASS J-BOX AND LED MODULE YOKE ASSEMBLY THRU CEILING HOLE. PUSH OFF TO SIDE TEMPORARILY. 2. PASS MOUNTING RING ASSEMBLY THRU CEILING HOLE AND SET ASIDE TEMPORARILY. PASS CEILING ADAPTER TRAY THRU CEILING HOLE. TRAY IS "C" SHAPED TO ALLOW IT TO ROTATE THRU HOLE. 3. POSITION TRAY ABOVE APERTURE AND CENTERED. POSITION MOUNTING RING ASSEMBLY ABOVE TRAY. CLIPS ARE PROVIDED TO SECURE TRAY TO CEILING. SCREW THRU CLIPS AND TRAY INTO MOUNTING RING. 4. BRING LED MODULE YOKE OVER MOUNTING RING AND ATTACH WITH WINGNUTS. BRING J-BOX ASSEMBLY OVER MOUNTING RING AND ATTACH WITH SCREWS THRU THE "C" CUTOUT IN THE TRAY. 5. POSITION TRIM RING OVER CEILING HOLE AND PASS REFLECTOR THRU TRIM RING INTO LED FIXTURE MODULE ENGAGING SPRING RETENTION CLIPS.

PHOTOMETRICS CONSULT FACTORY OR VISIT OUR WEBSITE FOR ADDITIONAL PHOTOMETRIC DATA IES FILE: --- 100 GILBANE STREET - WARWICK, RI - 02888

6LE-AURA SERIES FIXTURE MUST BE INSTALLED IN AMBIENT TEMPERATURE ENVIRONMENTS NOT EXCEEDING 50 C TO AVOID POSSIBLE DAMAGE TO THE LED MODULE FROM OVERHEATING. 6LE-AURA SERIES LUMINAIRES INCORPORATE LED MODULES WITH ON-BOARD THERMAL PROTECTION WHICH REDUCES CURRENT TO THE LED WHEN THE MAXIMUM TEMPERATURE IS EXCEDED PREVENTING OVERHEATING BY SLIGHTLY DIMMING THE LED MODULE. ELECTRICAL CONNECTIONS TO BE MADE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES CONNECT SUPPLY HOT TO BLACK FIXTURE WIRE CONNECT SUPPLY COMMON TO WHITE FIXTURE WIRE CONNECT GROUND TO GREEN OR BARE COPPER FIXTURE WIRE (DEPENDING ON MODEL) DISCONNECT ALL POWER TO FIXTURE BEFORE MAKING OR CHANGING ANY CONTROL WIRE CONNECTIONS 6LE-AURA-CT with "C" Setup / Control Option WIRELESS OPERATION USING THE COMMISSIONING TOOL (LCT) FOR COMPLETE WIRELESS OPERATION USING THE LCT COMMISSIONING TOOL TO CONTROL DIMMING, CCT, COLOR HUE AND COLOR SATURATION: THE PURPLE AND GREY CONTROL WIRES MUST BE CONNECTED TO EACH OTHER THE BLUE AND WHITE CONTROL WIRES MUST BE CONNECTED TO EACH OTHER NOTE: FOR COMMISSIONING TOOL (LCT) SETUP AND OPERATION FIXTURES MUST BE ORDERED AS "C" TO BE ABLE TO COMMUNICATE WITH THE LCT. "I" FIXTURES DO NOT HAVE LCT COMMUNICATION CAPABILITIES. 6LE-AURA-CT with "I" Setup / Control Option WIRELESS OPERATION USING ios APP FOR iphone or ipad FOR COMPLETE WIRELESS OPERATION USING THE ios APP FOR iphone OR ipad TO CONTROL DIMMING, CCT, COLOR HUE AND COLOR SATURATION: NO CONTROL WIRES ARE ATTACHED TO THE LED MODULE NOTE: FOR ios APP SETUP AND OPERATION FIXTURES MUST BE ORDERED AS "I" TO INCLUDE BLUETOOTH COMMUNICATION. "C" FIXTURES DO NOT HAVE BLUETOOTH CAPABILITIES.

6LE-AURA-CT with "C" or "I" Setup / Control Option 0-10v DIMMER HARD WIRED CONTROL OF CCT AND DIMMING WIRELESS CONTROL OF COLOR HUE AND SATURATION USING THE COMMISSIONING TOOL (LCT) or ios APP FOR HARD WIRED CONTROL USING 0-10V DIMMING DEVICES TO CONTROL CCT AND DIMMING: Connect a standard 0-10v Dimming Switch control device to the Blue and White wires on the LED Module control wire assembly. The Dimming Switch will control the CCT over the full tunable range of the module. Connect a standard 0-10v Dimming Switch control device to the Purple and Grey wires on the LED Module control wire assembly. The Dimming Switch will control the Dimming over the full dimming range of the module. Minimum dimming level is 1%. Color Hue and Saturation are controlled wirelessly by the LCT Commissioning Tool. For non-dimming applications connect Purple and Grey wires on the LED Module together and use the LCT Commissioning Tool set the desired light output level. Fixture will retain this output level. DO NOT USE THE ON-OFF SWITCHING OF THE DIMMER USED FOR CCT CONTROL TO POWER THE FIXTURES. FIXTURES MAY BE POWERED ON AND OFF FROM THE DIMMER USED FOR DIMMING. 6LE-AURA-CT with "C" or "I" Setup / Control Option 0-10v DIMMER HARD WIRED CONTROL OF DIMMING WIRELESS CONTROL OF CCT, COLOR HUE AND SATURATION USING THE COMMISSIONING TOOL (LCT) or ios APP FOR HARD WIRED CONTROL USING 0-10V DIMMING DEVICES TO CONTROL DIMMING: Connect the Blue and White wires on the LED Module control wire assembly together. Connect a standard 0-10v Dimming Switch control device to the Purple and Grey wires on the LED Module control wire assembly. The Dimming Switch will control the Dimming over the full dimming range of the module. Minimum dimming level is 1%. CCT, Color Hue and Saturation are controlled wirelessly by the LCT Commissioning Tool. For non-dimming applications connect Purple and Grey wires on the LED Module together and use the LCT Commissioning Tool set the desired light output level. Fixture will retain this output level. FIXTURES MAY BE POWERED ON AND OFF FROM THE DIMMER USED FOR DIMMING.

6LE-AURA-CT with "C" or "I" Setup / Control Option 0-10v DIMMER HARD WIRED CONTROL OF SCENE SET SETTING - NO SECONDARY DIMMING FOR SCENE SET HARD WIRING USING 0-10V DIMMING DEVICE Aura Fixtures are capable of storing 5 different preset output modes called scenes - each mode being a combination of dimming level, color saturation, color hue and color temperature. These levels are set wirelessly via the LCT or using the ios APP via a Bluetooth connection from an ios Smartphone or ipad, and are stored in the fixture LED module. Once programmed - the "scene" can be recalled by use of a standard 0-10v wall dimmer switch. The 0-10v wall dimmer switch is wired to the BLUE and WHITE wires fron the LED Module. The slide range is recognized by the LED module as being divided into 5 different zones corresponding to the 5 different preset scenes. While the slide is on zone 1, the module reacts as programmed for scene 1, and so on. To change from scene 1 to scene 2, slide the dimmer control until the scene changes. When no dimming is to be used, the LED Module purple and grey wires are tied together. DO NOT USE THE ON-OFF SWITCHING OF THE SCENE SET DIMMER TO POWER THE FIXTURES. 6LE-AURA-CT with "C" or "I" Setup / Control Option 0-10v DIMMER HARD WIRED CONTROL OF SCENE SET SETTING AND SECONDARY PROPORTIONAL DIMMING FOR SCENE SET HARD WIRING USING 0-10V DIMMING DEVICE Aura Fixtures are capable of storing 5 different preset output modes called scenes - each mode being a combination of dimming level, color saturation, color hue and color temperature. These levels are set wirelessly via the LCT or using the ios APP via a Bluetooth connection from an ios Smartphone or ipad, and are stored in the fixture LED module. Once programmed - the "scene" can be recalled by use of a standard 0-10v wall dimmer switch. The 0-10v wall dimmer switch is wired to the BLUE and WHITE wires fron the LED Module. The slide range is recognized by the LED module as being divided into 5 different zones corresponding to the 5 different preset scenes. While the slide is on zone 1, the module reacts as programmed for scene 1, and so on. To change from scene 1 to scene 2, slide the dimmer control until the scene changes. When dimming is to be used, the LED module purple and grey wires are tied to a second 0-10v wall dimmer switch. DIMMING IS PROPORTIONAL TO THE DIMMING LEVEL SET FOR EACH SCENE. At 100% on the dimming control the brightness is as set for the particular scene chosen. The dimmer control dims the light output down from that preset level. Minimum dimming level is 1%. DO NOT USE THE ON-OFF SWITCHING OF THE SCENE SET DIMMER TO POWER THE FIXTURES. FIXTURES MAY BE POWERED ON AND OFF FROM THE DIMMER USED FOR DIMMING.

6LE-AURA-CT with "CX" Setup / Control Option COMMISSIONING TOOL SETUP WITH HARD WIRED DMX CONTROL DMX HARD WIRING FOR FIXTURES WITH LCT COMMISSION TOOL SETUP Aura Fixtures are capable of control via DMX inputs. For "CX" models, the DMX controls are provided via a Digital Control Adapter onboard the fixture. It is possible to control multiple fixtures from a single Digital Control Adapter. The Digital Control Adapter is addressable. One adapter per fixture makes each fixture addessable. Multiple fixtures on one adapter are not individually addressable. Consult factory for configuration questions. NOTES: 1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm terminator at end of run. Maximum run distance 1800 feet. 2. Additional fixtures, or additional length, may be added by use of a DMX Booster (by others). 3. Module Data +/- wiring is class 2 rated. RS-485. 4. Suggested control wire (onless otherwise required by code) is Belden or equal #9842 2-Pair, Polyethylene Insulation, Chrome PVC Jacket, Drain Wire, UL AWM Style 2919, 30V 80degC, DMX 512. POWER (120/277VAC) TO FIXTURE TO BE CONSTANT - DO NOT SUPPLY POWER FROM SWITCHED SOURCE 6LE-AURA-CT with "IX" Setup / Control Option ios APP SETUP WITH HARD WIRED DMX CONTROL DMX HARD WIRING FOR FIXTURES WITH ios APP SETUP Aura Fixtures are capable of control via DMX inputs. For "IX" models, the DMX controls are built into the LED Module. Configuration of DMX Channels is accomplished thru the ios APP. Each fixture is individually addressable. NOTES: 1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm terminator at end of run. Maximum run distance 1800 feet. 2. Additional fixtures, or additional length, may be added by use of a DMX Booster (by others). 3. Module Data +/- wiring is class 2 rated. RS-485. 4. Suggested control wire (onless otherwise required by code) is Belden or equal #9842 2-Pair, Polyethylene Insulation, Chrome PVC Jacket, Drain Wire, UL AWM Style 2919, 30V 80degC, DMX 512. POWER (120/277VAC) TO FIXTURE TO BE CONSTANT - DO NOT SUPPLY POWER FROM SWITCHED SOURCE

6LE-AURA-CT with "CE" or "IE" Setup / Control Option COMMISSIONING TOOL or ios APP SETUP WITH HARD WIRED LUTRON ECOSYSTEM CONTROL LUTRON ECOSYSTEM HARD WIRING FOR FIXTURES WITH LCT COMMISSION TOOL or ios APP SETUP Aura Fixtures are capable of control via Lutron ECOSystem inputs. Lutron ECOSystem controls are provided via a Digital Control Adapter onboard the fixture. It is possible to control multiple fixtures from a single Digital Control Adapter. The Digital Control Adapter is addressable. One adapter per fixture makes each fixture addessable. Multiple fixtures on one adapter are not individually addressable. Consult factory for configuration questions. NOTES: 1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm terminator at end of run. Maximum run distance 1800 feet. 2. Module Data +/- wiring from Digital Control Adapter to LED Module (if required - multiple LED Modules with one DCA) is class 2 rated. RS-485. By others. 3. Suggested control wire (unless otherwise required by code) is Belden or equal #9842 2-Pair, Polyethylene Insulation, Chrome PVC Jacket, Drain Wire, UL AWM Style 2919, 30V 80degC, DMX 512. POWER (120/277VAC) TO FIXTURE TO BE CONSTANT - DO NOT SUPPLY POWER FROM SWITCHED SOURCE