LED Driver Compact fixed output

Similar documents
LED Driver Linear / area fixed output

LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED control gear Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact dimming

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Emergency lighting units EM powerled

LED Driver Compact dimming

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Constant voltage

Emergency lighting units EM powerled

LED Driver Compact dimming

LED Driver Compact dimming

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

OT 100/ /700 P5

DALI TOUCHPANEL BASIC TW. Operating and control unit

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

OPTOTRONIC Intelligent

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

HID control gear Electronic

Indoor Linear 80W Driver SI-C215280N2KR

LED MODULES READYLINE DL

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

Technical Information

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

TOSHIBA Industrial Magnetron E3328

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Catalogue Ignitors and power switches for HID

ODW-621. RS-232 Point-to-point applications

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

02/11/2015

Engineering Design Assurance Test Report ( Dual & Triple ) MODEL: SPS-100P-D2 V1 5 V 12 Amax

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

KRF EMC Filters Installation, Operation and Maintenance Manual

PLCC W LC CRI80 Datasheet

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Magnetic Sensor - Incremental EHP

Federal 3535 FX-C White Datasheet

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PLCC W 6000K Series Datasheet

Datasheet - SRB301LC 24VAC/DC

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Linear flow controls VFC Linear flow controls with actuator IFC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Features. Applications

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

PLCC W CRI K Datasheet

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Operating instructions

PLCC W 2 Series IEC White Datasheet

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Filters for Power Lines (Low Leakage Current)

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PLCC W CRI 80 Datasheet

LCD MODULE SPECIFICATION

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Ø50mm Shaft Multi-Turn Absolute Type

3M Sensored Termination (15 kv) QX-T15I-vi1-E

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

architecture mounting Features Product lighting

Photoelectric Sensors E3F2

Luminaire installation box Surface-mounted box Ceiling installation box

Features. Applications. Part Number Color Package Description

Features. High Brightness SMD LED Light source

Product Data Sheet 4656 EZ

Rack mounted telephone- and leased line modem for industrial applications

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

17W AR111 Module Datasheet

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

Product Data Sheet 4656 ZW

APPLICATIONS. Automatic warehouse. Trasportation lines

Cylindrical Photoelectric Sensor CY-100 SERIES

LIGITEK ELECTRONICS CO.,LTD. Property of Ligitek Only BAR DIGIT LED DISPLAY LBD1F1/25-XX DATA SHEET REV. : B

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

3mm Round White LED T-1. Technical Data Sheet. Part No: LL-304WC2E-W2-3TC

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Linear flow control with actuator IFC

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

LIGITEK ELECTRONICS CO.,LTD. Property of Ligitek Only. TRIPLE DIGIT LED DISPLAY (0.56 Inch) DATA SHEET LTD511/21-XX REV. : B

SPECIFICATION. DVB-T/ DVB-C / Worldwide hybrid Switchable NIM Tuner

Transcription:

Driver LC 10W 250mA fixc R ADV ADV series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 250 ma For luminaires of protection class II For ambient temperatures up to 60 C Nominal life-time up to 50,000 h (at ta 50 C) 5-year guarantee Properties Casing: polycarbonat, white Type of protection IP20 Functions Over protection Short-circuit protection Over temperature protection No-load protection Typical applications For track light, wall light and other pendent application È Standards, page 3 Wiring diagrams and installation examples, page 3 www.tridonic.com 1

Driver LC 10W 250mA fixc R ADV ADV series Technical data Rated supply 220 240 V AC range 198 264 V Mains frequency 50 / 60 Hz Typ. input current (at 230 V, 50 Hz, full load) 0.055 A Leakage current (at 230 V, 50 Hz, full load) < 700 µa THD (at 230 V, 50 Hz, full load) < 9 % Output current tolerance 2 ± 5 % Typ. output LF current ripple at full load 4 ± 5 % Turn on time (at 230 V, 50 Hz, full load) 0.5 s Turn off time (at 230 V, 50 Hz, full load) 0.5 s Ambient temperature ta -20... +60 C Ambient temperature ta (at life-time 50,000 h) 50 C Storage temperature ts -20... +70 C Mains surge capability (between L N) 1 kv Dimensions Ø x H ø42 x 20 mm ø42,19 tc Ordering data Type 32,65 28,64 Article number 20,1 Packaging, carton Packaging, palett Weight per pc. LC 10/250/40 fixc R ADV 28002402 300 pc(s). 5,400 pc(s). 0.045 kg Specific technical data Type Output current 2 Max. input current Typ. power consumption (at 230 V, 50 Hz, full load) Max. input power Output power range λ Efficiency at full at full load 1 load 1 λ at min. load 1 Efficiency at min. load 1 Min. forward Max. forward Max. output (U-OUT) Max. peak output current at full load 3 Max. casing temperature tc LC 10/250/40 fixc R ADV 250 ma 0.1 A 12 W 13 W 5 10 W 0.95 84 % 0.88C 80 % 21 V 40 V 50 V 263 ma 100 C 1 Test result at 230 V, 50 Hz 2 Output current is mean value. 3 The trend between min. and full load is linear and depends on load s -current character. 4 Typical value at full load, depends on load s -current character. www.tridonic.com 2

1. Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 61547 2. Thermal details and life-time 2.1 Expected life-time Expected life-time Type ta 50 C 60 C LC 10/250/40 fixc R ADV tc 90 C 100 C Life-time 50,000 h 30,000 h 3.3 Wiring instructions All connections must be kept as short as possible to ensure good EMI behaviour Mains leads should be kept apart from LED Driver and other leads (ideally 5 10 cm distance) The maximum length of output wires is 3 m. Secondary switching is not permitted. Incorrect wiring can damage LED modules. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). 3.4 Installation instructions The switching of LEDs on secondary side is not permitted. 3. Installation / wiring 3.1 Circuit diagram 220 240 V 50/60 Hz L N black red PRI SEC LED LED + blue brown 3.2 Connection Primary cable Secondary cable L N + brown blue red black 210 5 260 5 PRI: 2 x 0.75 mm 2 SEC: 2 x 0.5 mm 2 www.tridonic.com 3

4. Electrical values 4.1 Diagrams 4.1.1 Efficiency vs Load 90 Efficency [%] 85 80 70 80 90 100 4.1.2 Power factor vs Load 0,985 Power factor 0,970 0,955 0,940 0,925 70 80 90 100 4.1.3 THD vs Load 20 15 THD 10 5 0 50 60 70 80 90 100 www.tridonic.com 4

4.2 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LC 10/250/40 fixc R ADV < 9 < 4 < 4 < 3 < 1 < 2 Acc. to 6100-3-2. Harmonics < 5 ma or < 0.6 % (whatever is greater) of the input current are not considered for calculation of THD. 5. Functions 5.1 Over protection If the output is over (1.1 1.25 V) Vout, the LED Driver will shut down and enter its protection status, the Driver will reset and work normally if the fault condition was eliminated. 5.2 Short-circuit behaviour In case of a short circuit on the secondary side (LED) the LED Driver switched off. After elimination of the short-circuit fault the LED Driver will recover automatically. 5.3 Over temperature protection The LED Driver will reduce the LED output current. When temperature is up to 145 C (typical) the output current of the system will be reduced according to the sensed temperature. The output current will be reduce to about half of the setting value at 165 C (typical). When temperature rises above 170 C (typical), the device will stop working. 5.4 No-load protection The LED Driver will shut down and enter its protection status, the Driver will reset and work normally if the fault condition was eliminated. 6. Miscellaneous 6.1 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 6.2 Conditions of use and storage Humidity: 10 % up to max. 90 %, not condensed (max. 56 days/year at 95 %) Storage temperature: -20 C up to max. +70 C The devices have to be within the specified temperature range (ta) before they can be operated. 6.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 5