Level Measurement Continuous level measurement Radar transmitters

Similar documents
Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Flow Measurement SITRANS F M

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

SITRANS F M. Transmitter MAG 5000/6000 4/33

Flow Measurement SITRANS F M

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Pressure transmitter For applications in hazardous areas Model IS-3

2291 Guided Wave Radar Level Transmitter

OPTIFLEX 2200 C/F Technical Datasheet

Guided Radar (TDR) Level Transmitter for storage and process applications

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Explosion Proof Audible Signal db(a) Series YA60

Capacitance Level Measurement Electronic insert FEC 12

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

Model JDF Field Indicator

EXLUX ECOLUX C-LUX 6480 Series

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

EXLUX ECOLUX 6480 Series

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Pendant Light Fitting IEC Series 6470/2

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Rosemount 1151 Smart Pressure Transmitter

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Guided Wave Radar Level Meter

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

General Specifications

Process transmitter RMA422

PROPORTIONAL VALVES Sentronic plus

Process Transmitter RMA 422

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Inductive sensor NI3-EG08K-Y1-H1341

Mechanical flow switch for On/Off control

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DMP 331i / DMP 333i LMP 331 i

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor BI1.5-EG08K-Y1

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

EXPlora. Introduction

RMA42. Technical Information

Explosion Proof Audible Signal db(a) Series YA60

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Modular Lube Lubrication Systems System Controls

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Signal conditioning instruments

Single Point Flow Monitor SW118 SW119

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI10-M18-Y1X-H1141

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Liquid Level Sensor Type AKS 4100U

Pendant Light Fittings Series 6050

Technical Information RIA45

Operating instructions

General Specifications

RMA 3000 Remote Meter Assemblies Specifications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Parts List _2.1. Flygt /.890

XML LED X M L L E D. Explosionproof Linear LED Lighting

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Liquid Level Sensor AKS 4100U

Product Data Sheet 4656 EZ

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Parts List _2.1. Flygt /.190

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Liquid Level Sensor Type AKS 4100/4100U

Horn loudspeaker, Ex proof, short/long flare

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Transcription:

Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the horn antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Use largest possible antenna. Mounting on bypass 19 beam width: 1.5 horn = 19 2.0 horn = 15 3.0 horn = 10.0 horn = 8 Mounting on stilling well Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency allows for small antennas for easy mounting in nozzles Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 50 mm (2 inch) from the end of the antenna Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools such as PACTware or Fieldcare via SITRANS DTM Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1 Suitable for API 2350 Orient front or back of device toward vent. Mounting on vessel Orient front or back of device toward stillpipe slots. Use largest horn size possible in pipe. Mounting on a nozzle Application SITRANS LR250 includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller horn antenna options and decreasing sensitivity to obstructions. SITRANS LR250 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without saving to open the instrument s lid. SITRANS LR250 measures superbly on low dielectric media, and in small vessels, as well as tall and narrow vessels. Key Applications: liquid bulk storage tanks, process vessels, vaporous liquids, high temperatures, low dielectric media and applications with functional safety requirements SITRANS LR250 installation, dimensions in mm (inch) Min. 10 (0.) Siemens FI 01 2018 /211

Siemens AG 2018 Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 20 m (65 ft), antenna dependent Output HART Version 5.1 Analog output... 20 ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA Profile 3.01 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK 5.2.0 Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC60770-1) Maximum measured error 3 mm (0.118 inch) Influence of ambient temperature < 0.003 %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature -0... +80 C (-0... +176 F) Installation category I Pollution degree Medium conditions Dielectric constant r > 1.6, antenna and application dependent Process temperature -0... +200 C (-0... +392 F) (at process connection with FKM O-ring) -20... +200 C (-... +392 F) (at process connection with FFKM O-ring) Process pressure Up to 0 bar g (580 psi g), process connection and temperature dependent. See Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder-coated Cable inlet 2 x M20 x 1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight < 3 kg (6.6 lb) 3.75 mm (1½ inch) threaded connection with 1½" horn antenna Display (local) Graphic local user interface including quick start wizard and echo profile display Material Dimensions (nominal horn sizes) Process connections Process connection Flange connection 316L stainless steel [optional alloy N06022/2.602 (Hastelloy C-22 or equivalent)] Standard 1.5 inch (0 mm), 2 inch (8 mm), 3 inch (75 mm), inch (95 mm) horn, and optional 100 mm ( inch) horn extension 1½", 2" or 3" NPT [(Taper), ANSI/ASME B1.20.1] R 1½", 2" or 3" [(BSPT), EN 10226] G 1½", 2" or 3" [(BSPP), EN ISO 228-1] 2", 3", " (ANSI 150, 300 lb), 50, 80, 100 mm (PN 16, 0, JIS 10K) Power supply... 20 ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 PROFIBUS PA 15 ma Per IEC 61158-2 FOUNDATION Fieldbus 20.0 ma Per IEC 61158-2 Certificates and approvals General CSA US/C, CE, FM, RCM Radio FCC, Industry Canada, RED, RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety (China) ia mb IIC T Ga/Gb, Ex iad td A20 NEPSI Ex d ia mb IIC T Ga/Gb, Ex e IP67 T100 ºC Intrinsically Safe (China) NEPSI Ex ia IIC T Ga, Ex iad td A20 IP67 T100 ºC Non-sparking (China) NEPSI Ex na IIC T Gc Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia IIIC T100 C Da Non-sparking (Europe) ATEX II 3G Ex na IIC T Gc Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D, Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia/Kazakhstan) Increased Safety (Russia/Kazakhstan) Intrinsically Safe (Russia/Kazakhstan) Marine Functional Safety IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEX/ATEX II 1D Ex ia ta IIC T100 C Da EAC Ex d EAC Ex e EAC Ex ia Lloyd's Register of Shipping ABS Type Approval Bureau Veritas SIL-2 suitable in accordance with IEC 61508/61511 /212 Siemens FI 01 2018

Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C T a = -20... +50 C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = +50 C IECEx SIR 09.0073 Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays Siemens FI 01 2018 /213

Siemens AG 2018 Selection and Ordering data SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML531-77770 - 77 7 7 continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Click on the for the online configuration in the PIA Life Cycle Portal. Process Connection and Material 316L (1.35 or 1.0) stainless steel, PTFE emitter, FKM seal 1) 0 316L (1.35 or 1.0) stainless steel, PTFE emitter, FFKM seal 1) 1 Hastelloy C-22/2.602 (or equivalent), PTFE emitter, 2 FKM seal 2) Hastelloy C-22/2.602 (or equivalent), PTFE emitter, FFKM seal 2) 3 Process Connection Type Threaded connection 316L 1½" NPT (ASME B1.20.1) (tapered thread) 3) AA R 1½" [(BSPT), EN 10226-1] (tapered thread) 3) AB G 1½" [(BSPP), EN ISO 228-1] (parallel thread) 3) AC 2" NPT (ASME B1.20.1) (tapered thread) ) AD R 2" [(BSPT), EN 10226-1] (tapered thread) ) AE G 2" [(BSPP), EN ISO 228-1] (parallel thread) ) AF 3" NPT (ASME B1.20.1) (tapered thread) ) AG R 3" [(BSPT), EN 10226-1] (tapered thread) ) AH G 3" [(BSPP), EN ISO 228-1] (parallel thread) ) AJ Flanged connection 316L ) 2" Class 150 ASME B16.5, raised face BD 3" Class 150 ASME B16.5, raised face BE " Class 150 ASME B16.5, raised face BF 2" Class 300 ASME B16.5, raised face CD 3" Class 300 ASME B16.5, raised face CE " Class 300 ASME B16.5, raised face CF 50A 10K JIS B 2220 flat face FA 80A 10K JIS B 2220 flat face FB 100A 10K JIS B 2220 flat face FC DN 50 PN 16 EN 1092-1 Type B1 raised face GA DN 80 PN 16 EN 1092-1 Type B1 raised face GB DN 100 PN 16 EN 1092-1 Type B1 raised face GC DN 150 PN 16 EN 1092-1 Type B1 raised face GD DN 50 PN 0 EN 1092-1 Type B1 raised face HA DN 80 PN 0 EN 1092-1 Type B1 raised face HB DN 100 PN 0 EN 1092-1 Type B1 raised face HC DN 150 PN 0 EN 1092-1 Type B1 raised face HD Selection and Ordering data SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML531-77770 - 77 7 7 continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Flanged connection Hastelloy C ) 2" Class 150 ASME B16.5 raised face JA 3" Class 150 ASME B16.5 raised face JB " Class 150 ASME B16.5 raised face JC 2" Class 300 ASME B16.5 raised face JD 3" Class 300 ASME B16.5 raised face JE " Class 300 ASME B16.5 raised face JF DN 50 PN 16 EN 1092-1 Type B1 raised face KA DN 80 PN 16 EN 1092-1 Type B1 raised face KB DN 100 PN 16 EN 1092-1 Type B1 raised face KC DN 50 PN 0 EN 1092-1 Type B1 raised face KD DN 80 PN 0 EN 1092-1 Type B1 raised face KE DN 100 PN 0 EN 1092-1 Type B1 raised face KF 50A 10K JIS B 2220 raised face LA 80A 10K JIS B 2220 raised face LB 100A 10K JIS B 2220 raised face LC DN 50 PN 16 EN 1092-1 Type B1 raised face MA DN 80 PN 16 EN 1092-1 Type B1 raised face MB DN 100 PN 16 EN 1092-1 Type B1 raised face MC DN 150 PN 16 EN 1092-1 Type B1 raised face MD DN 50 PN 0 EN 1092-1 Type B1 raised face ME DN 80 PN 0 EN 1092-1 Type B1 raised face MF DN 100 PN 0 EN 1092-1 Type B1 raised face MG DN 150 PN 0 EN 1092-1 Type B1 raised face MH Communication/Output PROFIBUS PA 5) 1... 20 ma, HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 5) 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20 x 1.5 1 1½" horn A 2" horn (fits 2" ASME or DN 50 nozzles) B 3" horn (fits 3" ASME or DN 80 nozzles) C " horn (fits " ASME or DN 100 nozzles) D 1½" horn with 100 mm extension E 2" horn with 100 mm extension F 3" horn with 100 mm extension G " horn with 100 mm extension H Hastelloy C22 (or equivalent) 2" horn (fits 2" ASME or DN 50 nozzles) J 3" horn (fits 3" ASME or DN 80 nozzles) K " horn (fits " ASME or DN 100 nozzles) L 2" horn (fits 2" ASME or DN 50 nozzles) with M 100 mm extension 3" horn (fits 3" ASME or DN 80 nozzles) with N 100 mm extension " horn (fits " ASME or DN 100 nozzles) with P 100 mm extension /21 Siemens FI 01 2018

Selection and Ordering data SITRANS LR250 horn antenna 7ML531-2-wire, 25 GHz pulse radar level transmitter for 77770-77 7 7 continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Approvals General Purpose, CE, CSA, FM, FCC, RED, RCM A Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B B, C, D, Class II, Div. 1, Groups E, F, G, Class III T FCC, Industry Canada Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T Ga, C IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da, INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da, CE, RED, RCM Non-incendive: CSA/FM Class I, Div. 2, D Groups A, B, C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E RED, RCM Increased Safety: IECEx/ATEX II 1/2 GD,1D, F 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, CE, RED, RCM 6) Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb G ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, CE, RED, RCM 6) Explosion proof: CSA/FM Class I, II, and III, Div. 1, H Groups A, B, C, D, E, F, G, FCC, Industry Canada 6) Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, L Ex iad td A20 IP67 T100 C Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad td A20 IP67 T100 C 6) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, N Ex iad td A20 IP67 T100 C 6) Pressure rating Rating per Pressure/Temperature curves in manual 0 0.5 bar g (7.25 psi g) maximum 7) 1 1) Available with process connection options AA... HD and Versions A... H only 2) Available with process connection options JA... MH and Versions J... P only 3) Not available with options B, C, D, F, G, H. ) Not available with options A and E. 5) Available with Approval options A, B, C, D, K, and L 6) Available only with Communications option 2. 7) Available with Process Connection and Material 0, 1, 2, and 3 only Siemens FI 01 2018 /215

Siemens AG 2018 Selection and Ordering data Order code Selection and Ordering data Further designs Please add "-Z" to and specify Order code(s). Plug M12 with mating Connector 1)2)3) Plug 7/8" with mating Connector 2)3)) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Material inspection certificate 3.1 of EN 1020 Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511 3)5) Namur NE3 compliant, device preset to failsafe <3.6mA 5) Compact Operating Instructions for HART/ ma device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese Note: The Operating Instructions should be ordered as a separate line item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese Note: The Operating Instructions should be ordered as a separate line item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation A50 A55 Y15 C11 C12 C20 N07 A5E3369191 A5E3369171 A5E306583 A5E3369239 A5E3372685 A5E30662 Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese Note: The Operating Instructions should be ordered as a separate line item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Other Operating Instructions SITRANS LR250 Functional Safety manual, English Note: The Operating Instructions should be ordered as a separate line item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20 x 1.5, rated -0... +80 C (-0... +176 F), HART (two are required) One metallic cable gland M20 x 1.5, rated -0... +80 C (-0... +176 F), PROFIBUS PA and FOUNDATION Fieldbus (two are required) 6) FDA approved FKM O-ring for 2" G (BSPP) process connections -28... +80 C (-28... +176 F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section A5E3372700 A5E3372738 A5E306626 A5E3228671 7ML1930-1BK 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML1830-3AN 7ML571-... 7ML570-... 7ML57-... 7ML5750-... 1) Available with enclosure option 1 only 2) To be used with communication options 1 and 3 only. Connector has IP67 rating. 3) Available with approval options A and B. Available with approval option C for use on intrinsically safe applications only. Not rated for dust Ex. ) Available with enclosure option 0 only 5) Applicable to communication option 2 only 6) For use with communication options 1 and 3 only /216 Siemens FI 01 2018

Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) 90 130 C 80 70 65 C 60 50 0 30 20 10 0 0 20 0 60 80 100 120 10 160 180 200 220 Process flange surface temperature ( C) SITRANS LR250 ambient/process flange surface temperature curve Siemens FI 01 2018 /217

Dimensional drawings Threaded Horn 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 28 (1.1)* 196 (7.7) Retaining collar Process device tag Horn 159 (6.26) Sensor reference point See dimension table for height to sensor reference point O.D. O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Type O.D. 1-1/2" threaded connection Height to sensor reference point 2" threaded connection 3" threaded connection Beam angle Measurement range 1.5" horn 2" horn 39.8 (1.57) 7.8 (1.88) 135 (5.3) 166 (6.55) 180 (7.09) 19 degrees 15 degrees 10 m (32.8 ft) 3" horn 7.8 (2.9) 199 (7.85) 213 (8.39) 10 degrees " horn 9.8 (3.73) 25 (10) 268 (10.55) 8 degrees SITRANS LR250 Threaded Horn, dimensions in mm (inch) /218 Siemens FI 01 2018

Threaded Horn with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 196 (7.7) Retaining collar 159 (6.26) Sensor reference point 28 (1.1)* Process device tag See dimension table for height to sensor reference point O.D. Horn O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Type 1.5" horn 2" horn 3" horn " horn O.D. 39.8 (1.57) 7.8 (1.88) 7.8 (2.9) 9.8 (3.73) 1-1/2" threaded connection 235 (9.3) Height to sensor reference point 2" threaded connection 266 (10.7) 299 (11.77) 35 (13.9) 3" threaded connection 280 (11.02) 313 (12.32) 368 (1.9) Beam angle 19 degrees 15 degrees 10 degrees 8 degrees Measurement range 10 m (32.8 ft) SITRANS LR250 Threaded Horn with extension, dimensions in mm (inch) Siemens FI 01 2018 /219

Siemens AG 2018 Flanged Horn 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) Enclosure/ electronics 167 (6.6) 90 (3.5) Name-plate 227 (8.9) Flange Retaining collar 190 (7.8) Horn Sensor reference point 135.3 (5.32) 168.3 223.3 (6.62) (8.79) Process connection tag 50 (2) nominal 80 (3) nominal 100 () nominal horn O.D. Nominal Horn Size 50 (2) 80 (3) 100 () Horn O.D. 7.8 (1.88) 7.8 (2.9) 9.8 (3.73) Height to sensor reference point Stainless steel flange raised or Optional alloy flange flat-faced 135.3 (5.32) 138.3 (5.) 168.3 (6.62) 171.3 (6.7) 223.3 (8.79) 226.3 (8.90) Beam angle 15 degrees 10 degrees 8 degrees Measurement range SITRANS LR250 Flanged Horn, dimensions in mm (inch) /220 Siemens FI 01 2018

Flanged Horn with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) Enclosure/ electronics 167 (6.6) 90 (3.5) 227 (8.9) Flange Name-plate Retaining collar 190 (7.8) Sensor reference point Process connection tag Horn 235.3 (9.32) 268.3 (10.62) 323.3 (12.79) 50 (2) nominal 80 (3) nominal 100 () nominal Horn O.D. Nominal Horn Horn O.D. Height to sensor reference point Beam angle Measurement Size Stainless steel range flange raised or Optional alloy flange flat-faced 50 (2) 80 (3) 100 () 7.8 (1.88) 7.8 (2.9) 9.8 (3.73) 235.3 (9.26) 268.3 (10.56) 323.3 (12.73) 238.3 (9.38) 271.3 (10.68) 326.3 (12.85) 15 degrees 10 degrees 8 degrees SITRANS LR250 Flanged Horn with extension, dimensions in mm (inch) Siemens FI 01 2018 /221

Siemens AG 2018 Circuit diagrams Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Notes: Gland may or may not be provided depending on approval option. Shield for HART, PROFIBUS PA, and FOUNDATION Fieldbus Intrinsically Safe versions only. 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC 61010-1. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable (1... 22 AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. Part number: 7ML1930-1BK SITRANS LR250 connections /222 Siemens FI 01 2018

SITRANS LR250 Specials Selection and ordering data SITRANS LR250 Specials NOTE: LR260 head can be supplied with any LR250 process connection or antenna as special order. For LR250, this means a stronger signal and longer measurement range is possible. SITRANS LR250 horn version enclosures (PROFIBUS PA models) SITRANS LR250 Specials board stack, NPT cable inlet, approval option C, with FOUNDATION Fieldbus communication, SITRANS LR250 horn version enclosures (< 3.6 ma start-up HART) A5E0265606 board stack, NPT cable inlet, approval option A, with PROFIBUS PA communication, board stack, M20 cable inlet, approval option A, with PROFIBUS PA communication, board stack, M20 cable inlet, approval option B, with PROFIBUS PA communication, board stack, NPT cable inlet, approval option C, with PROFIBUS PA communication, board stack, M20 cable inlet, approval option C, with PROFIBUS PA communication, board stack, NPT cable inlet, approval option D, with PROFIBUS communication, board stack, M20 cable inlet, approval option D, with PROFIBUS PA communication, SITRANS LR250 horn version enclosures (FOUNDATION Fieldbus models) A5E01156836 A5E01156838 A5E0115681 A5E0115683 A5E011568 A5E0115686 A5E0115688 board stack, M20 cable inlet, approval option A, board stack, M20 cable inlet, approval option C, board stack, M20 cable inlet, approval option E, board stack, M20 cable inlet, approval option F, board stack, M20 cable inlet, approval option G, board stack, NPT cable inlet, approval option A, board stack, NPT cable inlet, approval option B, board stack, NPT cable inlet, approval option H, A5E02956317 A5E02956319 A5E02956320 A5E02956322 A5E02956323 A5E031096 A5E031097 A5E031099 SITRANS LR250 enclosure with board stack, NPT cable inlet, approval option B, with FOUNDATION Fieldbus communication, A5E03769538 SITRANS LR250 enclosure with board stack, NPT cable inlet, approval option D, with FOUNDATION Fieldbus communication, A5E03769539 SITRANS LR250 enclosure with board stack, M20 cable inlet, approval option E, with FOUNDATION Fieldbus communication, A5E0376953 board stack, M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, A5E0265608 board stack, NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, A5E02653792 board stack, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, A5E02653793 Siemens FI 01 2018 /223

Siemens AG 2018 SITRANS LR250 Specials SITRANS LR250 Specials Sun shield for SITRANS LR250 enclosure, stainless steel SITRANS LR250 horn antenna and extension kits A5E3912556 38 mm (1.5 inch) horn antenna kit, 1.5" process connections only 100 mm ( inch) horn antenna extension kit, 1.5" process connections only 50 mm (2 inch) stainless steel 316L horn antenna kit 75 mm (3 inch) stainless steel 316L horn antenna kit 100 mm ( inch) stainless steel 316L horn antenna kit 100 mm ( inch) horn antenna extension kit, 50 mm (2 inch), 75 mm (3 inch), and 100 mm ( inch) process connection A5E01151539 A5E01151553 A5E01151569 A5E01151571 A5E01151573 A5E01151577 50 mm (2 inch) horn antenna kit, Hastelloy C-22 A5E0115158 75 mm (3 inch) horn antenna kit, Hastelloy C-22 A5E01151585 100 mm ( inch) horn antenna kit, Hastelloy C-22 A5E01151587 5 Dupont 1Gr Polypack, PTFE grease kit A5E01151626 SITRANS LR250 lid with O-ring A5E026510 Ex-proof plugs Ex-proof plugs kit, 1/2" NPT, qty 5 A5E39979991 Ex-proof plugs kit, M20, qty 5 A5E39979992 /22 Siemens FI 01 2018