Don Russell Performing Arts Centre

Similar documents
Matt Dann Cultural Centre

THE STREET THEATRE. Technical Specifications

Latrobe Performing Arts Centre

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

2017 TECHNICAL SPECIFICATIONS

John Leslie Theatre. Technical Specifications. Updated July 2018

Esso BHP Billiton Wellington Entertainment Centre

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Technical Specifications

CENTRE FOR PERFORMING ARTS

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

MONASH University Academy of Performing Arts

Queensland Performing Arts Centre

Orange Civic Theatre

Monash Academy of Performing Arts

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Monash University Academy of Performing Arts

Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Yan Yean Theatre Technical Specifications

Access to back stage is off Fletcher St on the eastern side of the building

THEATRE Technical Specifications

Technical Specification

INFORMATION FOR VISITING COMPANIES

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Main House Technical Specification

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

CHELSEA THEATRE. Technical Specifications

RPAC REDLANDS PERFORMING ARTS CENTRE

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Theatre Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

DEREHAM MEMORIAL HALL

Gosford City Council

Theatre Technical Specifications

Technical Specification Pavilion Dance

HIRE AND TECHNICAL INFORMATION

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

Technical Data Sheet

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

New Theatre Royal Lincoln Technical Information

Technical Specifications

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Technical Specification Ardhowen Theatre

Hopgood Theatre NOARLUNGA CENTRE

Technical Specifications. Taylor Little Theater

Technical Information

Lighthouse Theatre Technical Specification

TECHNICAL SPECIFICATIONS

Roundhouse Theatre. Roundhouse Theatre. Technical Specifications. Updated 28/4/2008

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

The Haymarket Basingstoke Technical Specifications

Theatre Technical Specification

Technical Specification

Technical Specification

Bathurst Memorial Entertainment Centre Theatre Technical Specifications 2014

Technical specifications Main theatre. Sound

Technical Specifications Nov 2016

Darebin Arts & Entertainment Centre. Theatre

ISLAND HALL TECHNICAL INFORMATION

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Technical Specifications Updated 01/10/2017. Stage

JERWOOD VANBRUGH THEATRE

Main Stage Technical Specs - Hall #2

1

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

Summary. Access and Parking

TECHNICAL PACKAGE.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Arlington Arts Tech Spec 2018

Dr. Fred Speckeen Theatre. Information and Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

Visy Theatre technical information and general specifications 2019

Hopgood Theatre NOARLUNGA CENTRE

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Services and Specification

Generated from the APACA Technical Specifications Template. For more details visit Clocktower Centre.

Cornerstone Technical Specifications 2018 / V1

Barney Simon Theatre Technical Specifications

Technical Specification for the Alley Theatre, Strabane

Patriots Theater at the War Memorial Technical Data

Technical Information

Sandusky State Theatre Technical Specifications

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Stage. Get In & Parking

Technical Specifications

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Transcription:

Don Russell Performing Arts Centre Technical Specifications Updated 5 th Aug 2010 Technical Manager: Ursula Andinach Phone number: (08) 9493 4577 Fax number: (08) 9493 4532 Email address: uandinach@gosnells.wa.gov.au Office days Wednesday and Friday Venue: Don Russell Performing Arts Centre Phone number: (08) 9493 4577 Fax number: (08) 9493 4532 Website: www.gosnells.wa.gov.au Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au

STAGE Brief Stage Description: NB Sightline restrictions when using half and full-depth stage extension. Stage distributed load limit House Standard Concert Floor - No Limit. Ezistage Units - 300kg point load per unit. Stage rake No Stage Dimensions: Proscenium Width Height Depth 7.5 metres 4 metres 4.74metres Setting Line 200mm upstage from the DS edge of the stage when the stage extension is out. Distance From (SL = Setting Line, CL = Centre Line) SL to DS edge of stage extension 1.35m (half depth) 1.80m (med width) 2.70m (full depth) SL to rear wall 4.54 metres CL to OP wall (or obstruction) 3.75 metres CL to PS wall (or obstruction) 3.75 metres Stage to underside of grid 4.5 metres. Overhead obstructions All air-conditioning ducts are above the grid line Auditorium: Raked, one level seating Seating capacity with full or med depth thrust installed 198 Seating capacity with small depth thrust or without thrust installed 210 NOTE: Standard trust is a carpet surface. If this is a problem please let us know as an older uncarpeted thrust can be used but adds only 1.4m to the permanent stage depth. Orchestra Lift / Pit: Orchestra Pit No Orchestra Pit Flying Facilities: Fly System No Fly System Page 2 of 11

Drapery: Please note these are fixed positions *Type Material Colour Width Height Quantity House Curtain Velveteen Blue 4m 4.5m 2 Borders Wool Black 7.5m 0.5m 2 Legs Wool Black 1.5m 4.5m 4 Cyclorama Cotton White 7.5m 4.5m 1 Back wall Curtain Wool Black 4m 4.5m 2 Access Equipment: Wheeling Truss Platform Maximum reach is 5m. Ladders (1) 6m Aluminium Extendible (1) 4m Aluminium A frame (1) 2.5m Aluminium Articulated 3 Join Staging Units: Stage extensions are carpeted surfaces (6) Ezistage 1800 x 1350 (2) Ezistage Angle 2140 x 1350 x 1070 x 1723 (2) Ezistage Custom Cube Angle 1070 x1350 x 1723 Stage Covers: Style Dimensions Colour Ply wood over cement (permanent staging). Low pile carpet (Ezistage units). 7.5m wide by 4.74m deep (6.09m with small extension; 6.54m med extension; 7.44m with full extension) Black Stage Traps: No stage traps Loading Dock: Access Truck access via car park at the back of the theatre. Truck able to reverse up to loading dock Loading Dock Height from ground Loading Dock Door Dimensions 0 metres 2.40 meters High 2.35 metres Wide Stage Door Dimensions 2.45 metres High 2.10 metres Wide Page 3 of 11

Additional Rigging There are no bars allocated for set. The only bars available are the ones used for LX. LIGHTING Positions: Stage LX Bars Bars are not movable from there standard position FOH #1 Setting Line to lighting bar 5.5m Usable bar width 6m Working load 200kg FOH #2 Setting Line to lighting bar 9.4m Usable bar width 6m Working load 200kg FOH Perches (OP & PS) Setting Line to FOH Perch 5.5m Maximum lanterns per perch Maximum (3) prolite 650w profiles Each Perch comes with 3 boom arms LX 1 Setting Line to lighting bar 0.2m Usable bar width 6m Working load 200kg LX 2 Setting Line to lighting bar 3.6m Usable bar width 6m Working load 200kg LX 3 Setting Line to lighting bar 4.1m Usable bar width 6m Working load 200kg Control: Lighting desk Control channels Signal output Theatrelight 120 channel Cuemaster 120 Channels Signal distribution Control Room Remote riggers available onstage USITT DMX 512 Digital Communications Protocol NO Page 4 of 11

Dimmer Racks: Total Dimmers 5 Dimmer Locations Control Room 2.4Kw Dimmer Racks Jands Roadpak controlled via Theatrelighting Multiplexer Total dimmers @ 2.4kw per dimmer 60 5Kw Dimmer Racks 0 Total dimmers @ 5kw per dimmer 0 House Lights: Independant control Control positions Fade time adjustable Yes Control Room No Stage Luminare: Profiles Make Model Angle Detail / Accessories Watt Total Prolite 1000w 12 A sizes: 3 x gobo holders, 2 x iris Hand made: 3 x gobo frames, 4 x donuts 11 x assorted gobos (round) 3 x assorted gobos (square) Strand 16/30 6 gel frames only 500w 9 Strand Patt23 500w 2 Fresnel s Make Model Detail / Accessories Watt Total Prolite 10 Barn Doors 1000w 12 Prolite 7 Barn Doors 500w 7 Par Cans Make Model Angle Detail / Accessories Watt Total Par64 MFL 2x narrow globes 1000w 20 Par16 50w 5 Wash Make Model Detail / Accessories Watt Total Prolite Cyclorama Floods (3) cells per unit floor row 500w 4 Prolite Cyclorama Floods (3) cells per unit 1000w 4 Followspots: Make Model Angle Detail / Accessories Watt Total Selecon 7.5 19 4 colour changer 1200w 1 Pacific Page 5 of 11

Additional Lighting: Item Make Model Detail / Accessories Watt Total Pin spots 30w 2 Mirror Ball 20inch Heavy Duty Motor 1 Strobe 1 Faze HP-2S 700w 1 Data Projector Sony VPL CX 120 1 UV Light 1 Sconce Portable Appliance Tester K&M Starlight Mini Kyoritsu 6201A 1 4 Patching: Location Quantity Numbering Detail / Accessories (PS to OP) FOH 1 9 34 43 Twin Circuits FOH 2 9 44 52 Twin Circuits FOH Perches PS 4 59 62 Twin Circuits FOH Perches OP 4 55 58 Twin Circuits LX 1 11 23 33 Twin Circuits LX 2 11 12 22 Twin Circuits LX 3 11 1 11 Twin Circuits Floor PS 2 53 54 Twin Circuits, Two 10amp GPO Floor OP 2 63 64 Twin Circuits, Two 10amp GPO Power: 3 Phase Outlets (1) OP side of stage near the Stage Management Desk. Dimmers connected straight into the building power. Cabling: 240v Extension Cable The theatre has a good stock of extension leads to accommodate the venue s standard lighting rig. There is a stock of extra cables but extra cable may need to be supplied in extreme situations with power heavy equipment. Lighting : None of the venue bars can be swung or flown in. There are no in house DMX runs. If you require DMX for show please let us know so arrangements can be made AUDIO Control Positions: Control Room Centre stage back of seating sound proof. Page 6 of 11

Auditorium Located at the back of the seating - Stage Right (normal audio position). Total seat allocation 0 Control & Amplification: Mixer Soundcraft LX11, 24 channel, 6 Aux sends, 4 groups, phtm power. Amplifiers (1) Camco Tecton 38.4 Ampifier (FOH) (3) Australian Monitor Synergy SY1600 Power Amplifiers (F.B) EQ (3) DBX 1231 Dual 31 Band Graphic Equalisers FX (1) Lexicon multi-effects. Compression / Limiter / Gates (1) BX 166XL Dual Compressor (FOH) (1) DBX 1046 Quad Compressor Speakers: FOH Speakers (2) Nexo PS15 with PS15 System Controller (2) JBL MR (in-fill) Foldback (4) Turbosound TCS112 Playback: Item Make Model Detail Total American Dual C.D. and MP3 C.D Players 1 Audio Microphones: Make Model Detail / Accessories Use Total Sennheiser EW335G2D Handheld Radio Microphone 2 Sennheiser EW300G2 Lapel Mic kit 1 Shure UT Radio mic With SM58 Handhield 1 Shure SM58 Vocal 3 Shure Beta 57a Instrumental 4 Shure Beta 52a Kick Drum 1 AKG C1000s Condenser 4 Peavy PVM Condenser 2 Beyer SHM205A Lectern 1 Behringer Ultra- DI 4 Page 7 of 11

Accessories: Item Model Detail / Accessories Total Konig & Meyer Tall Boom 4 Soft-Touch Starline Konig & Meyer Starline Soft-Touch Short Boom 4 Round Base Straight Stands 2 Straight Stands 4 Line Patching: Location Quantity Numbering Detail Stage (rear) 24 1-24 24 sends, 4 returns Stage (front) 8 Sub-trunk Cabling: Audio Cable The theatre has a good stock of cable to accommodate the venue s equipment. Multicore (1) 30m 24 send 4 return FOH multicore (1) 15m 8way XLR return Multicore (1) 15m 8way XLR Drop Box Multicore AUDIO VISUAL Projectors: Type Model Detail / Accessories Total Sony VPL CX 120 3000 ansilumens 1 Screens: Projection Screen Front projection onto the CYC that is permanently rigged at the back wall of the stage. Screen dimensions 4.5m high, 7.5m wide AV Playback Equipment: Item Model Detail / Accessories Total LG DVD Player DV 276 1 LG Player V8824W DVD and VCR player 1 Page 8 of 11

Cabling: The theatre only has available audio cable for the projector Audio Visual : The projectors standard position is on seat D13, where there is located both audio and power. BACKSTAGE Communications: Stage Managers Desk The Stage Managers desk is located on OP and has access to head sets. Talkback Master Unit Jands Ezycom Talkback Total sub stations 4 In-House Camera Feed The in-house camera feed consist of 5 flat screens and two cameras. The screens are located in: Front Office/Box Office, Bio Box, Dressing Room and alongside the Stage Manager s Desk. There are two camera feeds, one of backstage near the Stage Manager s desk and one FOH of the stage. The FOH camera feed is sent to the Dressing Room, the Stage Manager desk and Front Office/Box Office.The Backstage camera feed is sent to Bio Box and Front Office/Box Office. This system allows Front of House to monitor the show and the backstage area during a performance, the actors to see what is happening on stage and allows the Stage Manager to call the show from backstage or the Bio Box more easily. TV Screens Cameras Soniq QV198LT 19" LCD TV Camera - HI Res Low Lux (Backstage) Camera - HI Res Low Lux (Bio Box) Paging The theatre has multi-zone paging from Box Office. Dressing Rooms: Dressing Room Capacity Toilets Shower Details Dressing room #1 12 (1) M (1) M There is a shower in each bathroom (1) F (1) F Laundry / Wardrobe: Washing Machines Dryers N/A N/A Page 9 of 11

Drying rooms N/A Iron / ironing board 1/1 Clothes racks Built into a separate wardrobe room, adjoining dressing room. Production Facilities: Production Desk There is a production desk available on opposite prompt corner along with curtain controllers and com system. Sound can also be controlled from here if requested. Greenroom: Tea / Coffee facilities Fridge / freezer Microwave Running water Yes No (but one in venue kitchen) No (but one in venue kitchen) Yes ADDITIONAL FACILITIES & INFORMATION Dance Studio: The Venue also contains a dance studio that is hired for classes. VENUE: Don Russell Performing Arts Centre Venue Contacts: Venue Address Murdoch Road, Thornlie WA (Forest Lakes Forum Shopping Centre Complex) Venue Postal Address P.O. Box 662, Gosnells WA 6990 Staff Contacts: Venue Manager Robert Housely Phone Number (08) 9493 4577 Email Address rhousely@gosnells.wa.gov.au Fax Number (08) 9493 4532 Head of Lighting Ursula Andinach Phone Number (08) 9493 4577 Email Address uandinach@gosnells.wa.gov.au uandinach@hotmail.com Office days Wednesday and Friday Page 10 of 11

Head of Audio Troy Nababan Mobile 0423 981 040 Email Address tnababan@gosnells.wa.gov.au troynanbaban@hotmail.com Marketing/Admin Farha Tajam Phone Number (08) 9493 4577 Email Address FTajam@gosnells.wa.gov.au Fax Number (08) 9493 4532 Box Office See Marketing/Admin Venue Plans: Venue Plan Available YES, hard copy at 1:50 can be mailed, or a PDF or DWG file emailed upon request. Venue Information: The theatre is fitted with an in house Talk Back System and Live Audio and Visual stage feed. Headsets are permanently located at the Audio Front of House Desk, Lighting Control Room, Stage Managers Desk, and Front of House Box Office. Additional headsets are available for use in other locations, including the Green Room. There is no wireless radio talk back. If you are planning to use any curtains, backdrops, or other stage dressings including sets in your production, please note that they must comply with Health (Public Buildings) Regulations 1992 Reg 23. If changes to the standard lighting rig are required, such as modification of existing fixtures or installation of additional equipment, allowance must be made by the hirer for the in-house lighting rig to be reinstalled to standard during bump out. Should you have any questions with any aspect of the information enclosed in this booklet or on any other technical aspect of your event, please contact the centre. Page 11 of 11