ELECTRONIC HARMONICS METER RELAY

Similar documents
ELECTRONIC MULTI METER

Clamp 200 A AC/DC (+ V AC/DC + Ω)

02/11/2015

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Certificate of Calibration

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

User Manual Power and Harmonics Analyzer Model PQ3350

USER S MANUAL. FX2N-8AD Analog input block

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Magnetic Sensor - Incremental EHP

Model Number Structure

multi-function meters

PRINCIPLES AND APPLICATIONS

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

LED Driver Linear / area fixed output

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

User Manual. Power and Harmonics Analyzer Model PQ3350

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

ISO-TECH IPM3005 Flexible AC Power Quality Tester Instruction Manual

LED control gear Compact fixed output

LED Driver Compact fixed output

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model

Hybrid Chart Recorder 250 mm (10")

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

Datasheet - SRB301LC 24VAC/DC

LED Driver Compact fixed output

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Generator protection relay

AS09..S 3-pole Contactors - Spring Terminals

Kuhnke Technical Data. Contact Details

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Series CT7N Bimetallic Overload Relays

MAP110 AC-DC Series Data Sheet

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

I/A Series Hardware Fiber Optic LAN Converter

1 Power Protection and Conditioning

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Solid-State Digital Timer

Ordering details. Approval. Classification

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Datasheet - SRB-E-201ST

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 32F00(CCFL TYPES) EXAMINED BY : FILE NO. CAS ISSUE : FEB.16,2000 TOTAL PAGE : 10

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

AF-300 E11 Adjustable Frequency Drive

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

10 SERIES. Light dependent relays A

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Gamma instabus. Technical product information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Level Measurement silometer FMC 420, FMC 423

Time-Lag Relays. User s Handbook (General Model)

Multifunction Digital Timer

LED Driver Compact dimming

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

ScopeMeter 190 Series Specifications

GC30 Digital Differential Pressure Gauge Operation Manual

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Magnecraft Power Relays

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Self--powered Time Counter

AMP DISPLAY INC. SPECIFICATIONS AMP DISPLAY INC 9856 SIXTH STREET RANCHO CUCAMONGA CA TEL: FAX:

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Modular pulse operated latching relay 16 A

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

R&S RT-Zxx High-Bandwidth Probes Specifications

n Transient feature simulates voltage variations, brownouts and transient voltage conditions

MILLITARY SPECIFICATION SHEET

User s Manual of Signal Level Meter TABLE OF CONTENTS

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

LCD MODULE SPECIFICATION

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Agilent 5345A Universal Counter, 500 MHz

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Preset counters, electronic

Magnetic and Hydraulic-Magnetic Circuit Breaker

TABLE OF CONTENTS. Instructions:

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Indoor Linear 80W Driver SI-C215280N2KR

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

TOSHIBA Industrial Magnetron E3328

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Transcription:

PRODUCT CATALOG ELECTRONIC HARMONICS METER RELAY

OUTLINE * RMS value, fundamental wave RMS value, conversion RMS value/, n-time harmonic RMS value/ / distortion factor can be measured or monitored by 1 unit. * Most suitable for constant monitoring of harmonics due to harmonics detection and alarm output. FEATURES HLC-110/110L 110*110*105mm (600g) * Alarm output can be extracted: 2 items from, n-time harmonic and distortion factor. * Analog output 2 circuits can be attach from measurement elements. * Record of max.or min value can be retained. TYPE AND SPECIFICATION CODE Specification Code Type A 3 4 5 6 7 0 9 HLC-110 No Backlight HLC-110L With Backlight (3) Input circuit (4) Input range (5) Auxiliary power (6) External operation input (7) Analog output 1 1Ф 2W 1Φ2W, 3Φ3W AC85-253V 0 None 0 No analog/ communication 2 1Ф 3W 5 5A 1 DC80-143V 2 Reset 1 4-20mA 3 3Ф 3W 6 1A For Both use 2 0-1mA 9 150V 2 DC20-56V 3 1-5V A 300V 4 0-5V 5 0-10V 2 (9) Alarm output Output: a contact for each (relay) Z Except above 1Φ3W 5 5A 6 1A 9 150-300V Z Except above Z Except above Z Except above Z Except above Z Analog output: Except above Z Except above http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 2

Equipment Specification Connect system LCD display Display update time Measurement Operating temperature/ Humidity range Storage temperature range Input, Auxiliary power M4 screw Output, M3 screw Main monitor : Character height 11mm Sub monitor (L): Character height 6mm Sub monitor (R): Character height 6mm Bar graph: 30 dots 4 digits 4 digits 4 digits RMS value: 4 sec. or less (Bar graph: 4 sec. or less) Harmonics: 10 sec. or less (Bar graph: 10 sec. or less) RMS value, fundamental wave RMS value, conversion RMS value/, n-time harmonic RMS value/ / distortion factor -10 to +55 C, 30 to 85% RH (No condensation) -25 to +70 C Material ABS (V-0) Exterior color: Black (Munsell N1.5) Mass Size 600g Refer to outline drawing (Compatible with wide angle indicator) Auxiliary Power Specification Power consumption ( With Backlight ) Power consumption ( No Backlight ) Rush current ( For Backlight & No Backlight both use ) AC85-253V 50/60Hz 10VA DC80-143V 5W DC20-56V 6W AC85-253V 50/60Hz 8VA DC80-143V 4W DC20-56V 5W AC110V 5.3A (Approx. 1.6ms) AC220V 10.5A (Approx. 1.6ms) DC110V 3.7A (Approx. 1.6ms) DC24V 5.0A (Approx. 2.0ms) DC48V 9.9A (Approx. 2.0ms) http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 3

Input Specification Input Consumption VA Voltage circuit rated value: 110V(FS: 150V) Voltage circuit rated value: 220V(FS: 300V) Current circuit: 5A, 1A 0.25VA or less 0.5VA or less 0.1VA or less External Operation Input (Reset) Input Specification Power Consumption Contact Capacity Shift input display: Indication reshuffling is possible by adding a voltage signal, function same as a DISPLAY switch. Reset input: Reset of the maximum, minimum and warning output are possible by adding a voltage signal. Rating same with auxiliar power, smallest pulse width 300ms impress continuation are possible. AC, DC100/110V 0.4VA, 0.4W AC200V/220V 1.4VA DC24V 0.3W DC48V 1.2W AC, DC100/110V 3mA AC200V/220V 6mA DC24V 10mA DC48V 20mA Output Specification Analog output: 2 circuits Rated value Response time Output Ripple Alarm output: 2 points 4-20mA: 550Ω or less, 0-1mA: 10kΩ or less 1-5V: 600Ω more than, 0-5V: 600Ω more than 0-10V: 2kΩ more than Specify in each circuit identical value. Non-insulation (minus common) between analog output. 10 sec. or less (In case of average time limit 0 sec.) Time to be within ±1 % of final constant value Less then 1% p-p against output span Output system Non-voltage 1a contact AC250V 8A, DC125V 0.3A (Resistance load) Contact capacity AC250V 2A, DC125V 0.1A (Inductive load) http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 4

PERFORMANCE Item Measuring element Specification Allowance *(1) Measuring range/ Display specification Display Analog output *(2) Note Am m eter digital display Voltm eter digital display Bar graph display Display setting potential element Time update display Dis tortion factor RMS value conversion RMS value Fundamental wave RMS value n-time harmonic content ratio n-time harmonic RMS value Dis tortion factor RMS value conversion RMS value Fundamental wave RMS value n-time harmonic content ratio n-time harmonic RMS value Main monitor, Sub-m onitor (L), Sub-monitor (R), Bar graph 0.0-100.0% (2nd - 15th harmonics) Max. phase display (Automatic change) ±2.5% ±2.5% AC5.00A - 8.00kA R-S-T Phase change ±1.5% ±1.5% 0.0-100.0% Max. phase display (Automatic change) ±2.5% ±2.5% AC5.00A - 8.00kA R-S-T Max. phase display (Automatic change) ±1.5% ±1.5% AC5.00A - 8.00kA R-S-T Max. phase display (Automatic change) ±1.5% ±1.5% 0.0-100% n = 3,4,5,7,9,11,13,15 Max. phase display (Automatic change) ±2.5% ±2.5% AC5.00A - 8.00kA R-S-T Max. phase display (Automatic change) ±1.5% ±1.5% 0.0-20.0% (2nd - 15th harmonics) Max. phase display (Automatic change) ±1.0% ±2.5% AC150V - 45.0kV RS-ST-TR Phase change ±1.5% ±1.5% 0.0-20.0% Max. phase display (Automatic change) ±1.0% ±2.5% AC150V - 45.0kV RS-ST-TR Max. phase display (Automatic change) AC150V - 45.0kV RS-ST-TR Max. phase display (Automatic change) 0.0-20.0% n = 3,4,5,7,9,11,13,15 Max. phase display (Automatic change) AC150V - 45.0V RS-ST-TR Max. phase display (Automatic change) Bar graph display of main monitoring element ±1.5% ±1.5% ±1.5% ±1.5% ±1.0% ±2.5% ±1.5% ±1.5% Single phase: No phase display Single phase 3 wire: R-T-N (Harmonics is excluded N phase). Analog output of : Lower lim it to upper limit output against 0-100%. Single phase: No phase display Single phase 3 wire: RN-TN-RT (Harmonics is excluded RT line). Analog output of : Lower lim it to upper limit output against 0-20%. Dis tortion factor, RMS value, 5-tim e harm onic convers ion, 5-tim e harm onics convers ion RMS value, fundam ental wave RMS value, n-tim e harm onic, n-tim e harm onics RMS value(n = 3,4,5,7,9,11,13,15) Harm onics ( Dis tortion factor, n-tim e RMS value/, 5-tim e RMS value/ Fundamental wave RMS value: 10 sec. or less, RMS value: 4 sec. or less ) Analog output res pons e tim e Setting tim e limit Contact alarm output 10 s ec. or les s (Average tim e lim it : 0 m in.) Display/ analog output Average tim e lim it : 0m in./ 1m in./ 2m in./ 5m in./ 10m in./ 15 m in./ 30m in. Average m eas uring measurement Mean value Detection when average measured value exceeds above setting. mode Detection Counter tim e Detection by counter time limit characteristics of instantaneous value regardless of average setting time limit. limit mode *(3), n-time harmonic (n = 3,4,5,7,9,11,13,15 ), measured value Function alarm display, alarm contact output at upper limit setting value (Detection max. phase in case of three phase). Setting accuracy Am m eter : ±2.5%, Voltm eter : ±1.0% % agains t relative harm onic 100% Ammeter :, n-time harmonic = 3,4,5,7,9,11,13,15), Dis tortion factor 5-100% (1% s tep), function exclus ion, with s etting index indication. Range setting Voltm eter : 5-tim e harm onic convers ion, n-tim e harm onic = 3,4,5,7,9,11,13,15), Dis tortion factor 1-20% (0.1% s tep), functional exclus ion, with s etting index indication. Contact output Non-voltage a-contact 2 items (upper limit 1, upper limit 2) Independence setting Option Analog output *(2) Reset system Output potential element Autom atic or m anual (s etting) Analog output, reset input (max. value, min. value, alarm output) Dis tortion factor, RMS value, 5-tim e harm onic convers ion, 5-tim e harm onic RMS value, fundam ental wave RMS value, n-time harmonic, n-time harmonics RMS value (n = 3,4,5,7,9,11,13,15) *(1) Allowance: -, of digital display: % against 100%. - RMS value, n-time RMS value of digital display: % against voltage or current range. - Analog output: % against output span. *(2) Analog output is option *(3)Only is possible. Either upper limit 1 or upper limit 2 can be setting. http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 5

PERFORMANCE (Continued) Alarm output counter time lim it ch aracteristic Upper lim it setting value 35% (voltm eter 3.5%) 1 000 0 (Amm ete r) (Voltm eter) 5 -tim e % ITEMS TO SPECIFY WHEN PURCHASE Specify for type product, specification and units require. Example of specification. Refer to page 1 for specification code. Type Specification code HLC-110 L A 3 5 1 2 1 0 2 No Backlight : Blank Hard Input Input Auxiliary External Analog Alarm With Backlight : L Model Circuit Range Power Operation Input Output Output *Change from initial setting can be accepted with compensation. Specify the items to change. Refer to p.14 for initialization value. *Have a consultation for specification which is not in specification code. http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 6

Measuring Range * Voltage Measuring Range 150V (110V) 4500V (3300V/110V) 150.0V (110V) 4.50kV (3300V/110V) 300V (220V, 220V/110V) 9000V (6600V/110V) 300.0V (220V, 220V/110V) 9.00kV (6600V/110V) 600V (440V/110V) 15.00kV (11.0kV/110V) 1500V (1100V/110V) 30.0kV (22.0kV/110V) 3000V (2200V/110V) 45.0kV (33.0kV/110V) 3.00kV (2200V/110V) * Single phase 3 wire: only 150V, 150.0V. * Current Measuring Range 5.00A 25.00A 120A 750A 3000A 6.00A 25.0A 150.0A 800A 3.00kA 7.50A 30.00A 150A 1000A 4000A 8.00A 30.0A 200.0A 1.00kA 4.00kA 10.00A 40.0A 200A 1200A 5000A 10.0A 50.0A 250.0A 1.20kA 5.00kA 12.00A 60.0A 250A 1500A 6000A 12.0A 75.0A 300.0A 1.50kA 6.00kA 15.00A 80.0A 300A 2000A 7500A 15.0A 100.0A 400A 2.00kA 7.50kA 20.00A 100A 500A 2500A 8000A 20.0A 120.0A 600A 2.50kA 8.00kA http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 7

Outline Drawing (unit: mm) Connection Diagram ( 10 ) Note: * (8) Output 1, output 2, reset input is option * (9) In case of single phase 3 wire: S phase becomes N phase. *(10) In case of low-voltage circuit, secondary-side earth of VT, CT is not necessary. Also when used in 110V or 220V direct, VT is not necessary. http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 8

NAME AND THE FUNCTION OF EACH PART 5-time Conversion, n-time, Distortion Factor When upper limit detection, measurement item detected will blinks. Upper Limit Setting Index Upper limit alarm setting value is indicated. Upper limit 1 and upper limit 2 can be set individually. Bar Graph Display Indicated main monitor measurement value. Digital Display 3 elements can be measured and monitored simultaneously. Sub monitor (L) Main monitor Sub monitor (R) Scale Number Set automatically with measuring range setting. Max. Min. Max. and Min. value are indicated. Automatic Reset, Manual Reset Indicated the return method of upper limit detection. Phase Display Always change and display the max. phase by automatically. (RMS value measurement is excluded). No display single phase. SET This switch is for setting mode use. When press the ON continuously more for 3 sec. display mode will be change to setting mode. This switch is used to set a setting value in setting mode. - This switch is used for confirm time limit setting, upper limit 1 and upper limit 2 setting value, voltage (current) and flicker value. This switch also use to carry down the setting value in setting mode. And in + main monitor change-over switch operation mode, use this switch to change the measuring elements to opposite direction. (Usual operation) + This switch use to changeover the measuring elements for main monitor. Measuremnet is change by this order. 5-time 3-time 4-time 5-time 7-time 9-time 11-time 13-time 15-time RMS value R phase (RS) *(4) RMS value S phase (ST) *(4) RMS value T phase (TR) 5-time conversion RMS value 1-time RMS value 3-time RMS value 4-time RMS value 5-time RMS value 7-time RMS value 9-time RMS value 11-time RMS value 13-time RMS value 15-time RMS value The function can replaced with DISPLAY switch by setting *(5) This switch used to carry up the setting value in setting mode If not operate for 10 min. display will return to original setting being completed setting pattern. Upper Limit 1, Upper Limit 2 Indicated selection of upper limit setting index or contact at detection. Unit Display Set automatically with measuring range setting. In the display mode, max. and min. value of measuring elements are displayed by pressing +/- simultaneously for 1 sec. DISPLAY Use this switch to change the AC. 3 phase (*6). The function can replaced with + switch. Setting mode will returns to display mode after 1 action. If not operate for 10 min, display will returns to original setting being completed setting display. RESET/ SHIFT Alarm display and output of upper limit value 1 and 2, max. and min. hold value of each measurement can be reset by pressing ON continuously more for 1 sec. Use this to shift an item in the setting mode. Note: *(4) RMS value for S phase (ST), T phase (TR) can be skip in single phase. There is no display of R phase (RS). *(5) No function to replace + switch and DISPLAY in single phase. *(6) Measuring element changeover in single phase. http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 9

SETTING Pleasr refer to instruction manual for attachment setting method details. Setting - 1 Setting - 2 SET and DISPLAY 3s DISPLAY Measurement range setting RESET/SHIFT and + RESET/SHIFT and - DISPLAY Output element setting RESET/SHIFT and + RESET/SHIFT and - DISPLAY Display dead band setting RESET/SHIFT and + RESET/SHIFT and - Display mode DISPLAY RESET/SHIFT and + Measurement display ON/OFF setting RESET/SHIFT and - DISPLAY Period setting RESET/SHIFT and + RESET/SHIFT and - Note: *(7) Skip in case of single phase. Refer to Page 13 for display combination (pattern). DISPLAY Reset method setting RESET/SHIFT and + RESET/SHIFT and - DISPLAY Return to initial set value RESET/SHIFT and RESET/SHIFT and - http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 10

LC-110 SERIES COMMON SPECIFICATION Approved Standard/ Pulse Output/ Intensity Type Item No Backlight With Backlight multi meter harmonics m eter relay demand m ulti m eter max./ min. m ulti m eter overload/ leakage detection meter relay three phase current meter three phase voltage meter DC receiving meter DC input meter QLC-110 HLC-110 DLC-110 MLC-110 LLC-110 ALC-110 VLC-110 XLC-110 TLC-110 QLC-110L HLC-110L DLC-110L MLC-110L LLC-110L ALC-110L VLC-110L XLC-110L TLC-110L Approved standard Pulse output Output element Outout pulse constant -1, -2, -3, -4, -5, -7 JIS C 1216 JIS C 1263 EIA standard RS-485-1, -2, -7-1, -2, -3, -5, -7 JIS C 1216 EIA standard RS-485-1, -2, -7 EIA standard RS-485-1, -2, -7 JIS C 8325 JIS C 8374 JIS C 1216-1, -2, -7-1, -2, -7-1, -2, -7, -9 JIS C 1010-1 EIA standard RS-485-1, -2, -7, -8, -9 JIS C 1010-1 EIA standard RS-485 Watt-hour OR - Watt-hour - Watt-hour - - - - var-hour *Output system: Photo MOS - FET relay 1 a contact. Contact capacity: AC, DC125V 70mA (resistance load, inductive load) Output ON resistance: 10Ω or less. *Pulse width: 250ms ±10% (There is a case of 100-130ms by range setting.) When the output pulse cycle at the rated electric power becomes the speed of 2 pulses or more per second by setting voltage measurement range, current measurement range, and output pulse unit, the output pulse width becomes 100-130ms. *Output pulse cycle = Rated electric power [kw] / output pulse unit [kwh / pulse] / 3600 [sec.] For example: when voltage measurement range: 9000V (6600V / 110V), current range: 80.0A (80A / 5A), output pulse unit: 0.1 kwh / pulse rated electric power = 1kW (6600 / 110V) (80 / 5A) = 960 [kw] output pulse cycle = 960 [kw] / 0.1 [kwh / pulse] / 3600 [sec.] = 2.667 pulse / sec. pulse width becomes 100-130ms. *Output pulse unit can be set in following range. Output pulse unit is not changed by changing measuring range. Three phase 3 wire / Three phase 4 wire: Full load power (kw, kvar) = 3 rated voltage (V) rated current (A) 10-3 Single phase 3 wire : Full load power (kw, kvar) = 2 rated voltage (V) rated current (A) 10-3 Single phase : Full load power (kw, kvar) = Rated voltage (V) rated current (A) 10-3 1 or more 10 or more 100 or more 1,000 or more 10,000 or more 100,000 or more Full load power (kw, kvar) Below1 Below 10 Below 100 Below 1000 Below 10,000 Below 100,000 Below 1,000,000 Multiplying Output pulse unit kwh (kvarh) / pulse factor 0.1 0.01 0.001 0.0001 0.01 *(1) 1 0.1 0.01 0.001 0.1 10 1 0.1 0.01 1 100 10 1 0.1 10 1,000 100 10 1 100 10,000 1,000 100 10 1,000 100,000 10,000 1,000 100 10,000 * (1) Applied to only DLC-110/ 110L. Even though multiplying factor is 0.01, multiplying factor display is 0.1 (integer digit: 4 digits display Expansion display: 4 digits after decimal point.) http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 11

LC-110 SERIES COMMON SPECIFICATION Approved standard/ Pulse output/ Intensity (1) Voltage circuit: 2 times of rated voltage (10sec.) 1.2 times (continuity) Overload capacity (2) Current circuit: 40 tim es of rated current (1 s ec.), 20 tim es (4 s ec.), 10 tim es ( 16 s ec.), 1.2 tim es (continuity) (3) Auxiliary power: 1.5 times of rated voltage (10 sec.), 1.2 times (continuity), 1.5 times of rated voltage at DC100/ 110 (10 sec.), 1.3 times (continuity) (4) DC input circuit (4 to 20m A): 10 tim es of rated current (5 s ec.), 1.2 tim es (continuity) Ins ulation resistance (1) Between electrical s ys tem and cas e (ground) DC500V 50MΩ or more (2) Between input, output and auxiliary power DC500V 50MΩ or more (3) Between analog output and puls e output DC500V 50MΩ or m ore (QLC, DLC, LLC) (4) Between analog output and alarm output DC500V 50MΩ or m ore (HLC, DLC, MLC, LLC) (5) Between com m unication output and puls e output DC500V 50MΩ or m ore (QLC, DLC) (6) Between com m unication output and alarm output DC500V 50MΩ or m ore (DLC,MLC) (7) Between puls e output and alarm output DC500V 50MΩ or m ore (DLC,LLC) (8) Between alarm output 1 and alarm output 2 DC500V 50MΩ or m ore (HLC,LLC) (9) Between DC input (4 to 20m A), AC input and auxiliary power DC500V 50MΩ or m ore (QLC with DC input) (10) Between DC inputs DC500V 50MΩ or m ore (XLC,TLC) (11) Non-ins ulation by m inus com m on between analog outputs. (QLC, DLC, HLC, XLC, TLC, MLC) (1) Between electrical s ys tem and cas e (ground) AC2000V 50/ 60 Hz 1 m in. (2) Between input, ouutput and auxiliary power AC2000V 50/ 60 Hz 1 m in. (3) Between analog output and puls e output AC1500V 50/ 60 Hz 1 m in. (QLC, DLC, LLC) (4) Between analog output and alarm output AC1500V 50/ 60 Hz 1 m in. (HLC, DLC, MLC, LLC) Strength Withstand voltage Lightning impulse withstand voltage Noise capacity Vibration/ shock (5) Between com m unication output and puls e output AC1500V 50/ 60 Hz 1 m in. (QLC, DLC) (6) Between com m unication output and alarm output AC1500V 50/ 60 Hz 1 m in. (DLC, MLC) (7) Between puls e output and alarm output AC1500V 50/ 60 Hz 1 m in. (DLC, LLC) (8) Between alarm output 1 and alarm output 2 AC1500V 50/ 60 Hz 1 m in. (HLC, LLC) (9) Between DC input (4 to 20m A), AC input and auxiliary power AC2000V 50/ 60 Hz 1 m in. (QLC with DC input) (10) Between DC inputs AC2000V 50/ 60 Hz 1 m in. (XLC, TLC) (11) Non-ins ulation by m inus com m on between analog outputs. (QLC, DLC, HLC, XLC, TLC, MLC) (1) Between electrical system (analog output/ communication output excluded) and ground 6kV 1.2/ 50µs pos itive/ negative polarity 3 tim es for each (QLC, DLC) (2) Between electrical system (DC input 4 to 20mA excluded) and ground 5kV 1.2/ 50µs pos itive/ negative polarity 3 tim es for each (3) Between analog output or communication output and ground 5kV 1.2/ 50µs pos itive/ negative polarity 3 tim es for each (QLC,DLC) (4) Between auxiliary power and ground. 7kV 1.2/ 50µs pos itive/ negative polarity 3 tim es for each (LLC) (1) Oscillatory surge voltage 1 to 1.5MHz peak voltage: When attenuated oscillatory waveform (2.5 to 3kV) is applied repeatedly: Meas ured error: within 10% (power circuit, AC voltage circuit, AC current circuit, XLC, TLC: DC voltage/ current circuit) No com m unication error/ com m unication halt (2) Square-wave im pulse noise Noise (1µS, 100ns width) is repeatedly applied for 5 min. : Measured error is within 10% AC voltage/ AC current circuit (norm al/ com m on) 1.5 kv or m ore Power circuit (norm al/ com m on) 1.5 kv or m ore Puls e output (com m on) 1.0 kv or m ore Alarm output (com m on) 1.0 kv or m ore Operation input (com m on) 1.0 kv or m ore Analog output (Inductive) 1.0 kv or m ore Com m unication output (Inductive) 1.0kV or m ore (3) Radio noise: When radion wave (150, 400, 900MHz) is applied (5W, 1m) intermittently: Measured error is within 10% (4) Electros tatic nois e: At the pas s age of electric current 8kV Meas ured error : within 10% At no passage of electric current 10kV: No damage (condenser charge system) Note: There are some cases that some item can not be applied for particular model. Refer to type and specification code. Vibration: 1/ 2 peak-peak: 0.15m m 10 to 55Hz 1 octave/ m in. 5 tim es s weep Shock: 490m /s ² 3 tim es for each direction. http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 12

DISPLAY COMBINATION (Pattern) (1) Single phase/ Three phase 3 wire/ Single phase 3 wire ( Ammeter ) No. No. Pattern Main monitor Sub-monitor (L) Sub-monitor (R) Bar graph Note 1 Pattern 1 RMS value A(R) Max. + Standard 2 Pattern 2 7-time harmonic Max. + 3 Pattern 3 RMS value A(R) 4 Pattern 4 7-time harmonic Max. + Max. + Specification 5 Pattern 5 content ratio RMS value A(R) 7-time harmonic Max. + (2) Single phase/ Three phase 3 wire/ Single phase 3 wire ( Voltmeter ) No. No. Pattern Main monitor Sub-monitor (L) Sub-monitor (R) Bar graph Note 1 Pattern 1 Distortion Factor 7-time harmonic Max. + Standard 2 Pattern 2 Distortion Factor RMS value V(RS) Max. + 3 Pattern 3 4 Pattern 4 RMS value V(RS) 7-time harmonic Max. + Max. + Specification 5 Pattern 5 content ratio RMS value V(RS) 7-time harmonic Max. + http://www.daiichi-ele.co.jp Digital Measuring Instrument Catalog e-fb-098a 13

INITIALIZATION VALUE 3 Phase 3 Wire / Single Phase Single Phase 3 Wire Setting Item Ammeter 110V input Voltmeter 220V input Ammeter Voltmeter Pattern Pattern 1 Pattern 1 Pattern 1 Pattern 1 1 Display Combination Main monitor Sub monitor (L) RMS value A(R) RMS value A(R) Sub monitor (R) 7-time harmonic 7-time harmonic Bar graph Max. + Max. + Current Upper limit 100.0A (/5A) *(2) 500A (/5A) Max. + Max. + 2 Flicker Upper limit 7260V (/121V) *(3) 242V 110.0V Voltage Lower limit 5940V (/99V) *(4) 198V 90.0V 3 Current range 100.0A (100A/5A) *(2) 500A (500A/5A) 4 Voltage Range 9000V (6600V/110V) *(5) 300V (220V direct) 150V (100-200V) 5 6 Detection Characteristic 7 Alarm Output 1 Element 9 Output 1 Factor *(1) Output 2 Factor *(1) Analog output : Analog output : RMS value A(R) Analog output : Analog output : RMS value A(R) Analog output: Analog output : Counter time limit mode Mean value mode Counter time limit mode Mean value mode 0 min. (display average time at counter time limit) Analog output : Analog output: 0 min. (display average time at counter time limit) Upper Limit 35% Detection Value 3.5% 35% 3.5% Detection Characteristic Function cancellation Mean value mode Function cancellation Mean value mode 8 Alarm Output 2 Element Function cancellation Function cancellation Upper Limit Function cancellation Detection Value 3.5% Function cancellation 3.5% Time Limit 0 min. (display average time and detection time limit) 0 min. (display average time and detection time limit) 10 Return Method Automatic return Automatic return Automatic return Automatic return Note: *(1). Only for select the option. *(2). 50.0A (/5A) when single phase specification. *(3). 3630V (/121V) when single phase specification. *(4). 2970V (/99V) when single phase specification. *(5). 4500V (3300/ 110V) when single phase specification. http ://www.da iich i-ele.co.jp Digital Measuring Instrument Catalog e-fb98-098a 14