SOLO ADSS Short-Span Cables, Fibers

Similar documents
FREEDM Loose Tube Interlocking Armored Cables

Mining and Petrochemical Fiber Optic Cables

Installation of Solo ADSS All-Dielectric Self-Supporting Fiber Optic Cables

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

OPTICAL FIBRE CABLE NETWORK 2004/1

Industry solutions: Broadcast

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

LD Series High Performance Loose Tube Fiberoptic Cables

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Detailed Specifications & Technical Data

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Number of Fiber 6 Core 12 Core. Part Number

INDUSTRY SOLUTIONS: MINING

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

TECHNICAL SPECIFICATION

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION. Optical Fiber Cable

Micro duct Cable with HDPE Sheath for Installation by Blowing

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

Number of Fiber 6 Core 12 Core 24 Core 48 Core

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

AFL Telecommunications

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Splice Closure Fiber (SCF) Family

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

1. General. 1. Scope. 2. Quality Assurance

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Ø 1000 * 588 mm 50 kg

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Product Catalogue. Fibre Optic Cable

Table of Contents. Open Matrix System (OMS) 1-2

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Empowering businesses through innovative network solutions.

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Revision No. 4 Page No. Page 1 of 7

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

TENDER SUMMARY. Tender Title:

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

A Comparison of Dry Versus Gel Filled Optical Cables

OTS-300 Express Series Power Meters/Sources and Testers

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Water blocking tape. Locator ridge HPA-0486

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

Stretch More Out of Your Data Centre s Multimode Cabling System

OPTICAL CABLE FIBER-LAN INDOOR

GenSPEED Category 5e Cables 3

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

SPECIAL SPECIFICATION 8540 Telecommunication Cable

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Mar11 Rev E

PRO SERIES FIBRE-150M

Purchase Now ANSI/ICEA S

The FiberMark1 offers an ideal solution for

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Keyed LC Connector Solution A LANscape Solutions Product

OmniStar GX2 Headend Optics Platform

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

SECTION 4 TABLE OF CONTENTS

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

FIBRE OPTIC CABLE SOLUTIONS

The World Of Professional Fiber Optics. safe flexible reliable

ETSI ES V1.1.1 ( )

Transcription:

features and benefits Loose tube design Self-supporting Track-resistant jacket available Innovative waterblocking cable core SOLO ADSS Cable Drawing ZA-2615 Stable performance and compatibility with all common fiber types Easy, one-step installation Suitable for installations up to 25 kv electric field potential Provides efficient and craft-friendly cable preparation SOLO Cable, 36-Fiber Drawing ZA-2615 Corning Cable Systems SOLO ADSS Short-Span Cables are all-dielectric, self-supporting (ADSS) cables designed for easy and economical one-step installation in campus backbones with self-supporting installations where metallic messengers cannot be used. The loose tube design provides stable performance over a wide temperature range and is compatible with any telecommunications-grade optical fiber. The economical singlejacket design can span distances up to 600 ft in NESC light conditions, 500 ft in NESC medium conditions and 300 ft in NESC heavy conditions (see Sag and Tension chart). This cable incorporates innovative waterblocking materials, eliminating the need for traditional flooding compound and providing efficient and craft-friendly cable preparation. While the concentric, self-supporting cable design allows easy, one-step installation, using standard hardware and installation methods, the SZ-stranded, loose tube design isolates optical fibers from installation and environmental rigors (continued) SPECIFICATION SHEET EVO-360-EN PAGE 1

and facilitates midspan access. The ADSS short-span cables are also available with a proprietary track-resistant polyethylene (TRPE) jacket suitable for installation in electric field potentials up to 25 kv. SOLO Cable, 96-Fiber Drawing ZA-2615 SOLO Cable, 144-Fiber Drawing ZA-2615 SPECIFICATION SHEET EVO-360-EN PAGE 2

specifications Temperatures Approvals and Listings Common Installations Design and Test Criteria Preformed Line Products (PLP*) Dead-End Product Storage: Installation: Operation: Corning Cable Systems recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation temperature range specifications for best installation results. * PLP = Preformed Line Products (www.preformed.com) -40 to +70 C (-40 to +158 F) -30 to +70 C (-22 to +158 F) -40 to +70 C (-40 to +158 F) RDUP 7 CFR 1755.900 (formerly RUS) Outdoor self-supporting aerial ANSI/ICEA S-87-640 FIBERLIGN dead-end for ADSS limited tension dead-end Nominal Nominal Number Cable Weight Outside Minimum Bend Radius PLP Dead-End Fiber of Tube kg/km Diameter Loaded Installed Hardware Count Positions (lb/1000 ft) mm (in) cm (in) cm (in) Part Number 2-72 6 92 (62) 10.9 (0.43) 16.4 (6.5) 10.9 (4.3) 2872002 73-96 8 122 (82) 12.6 (0.50) 18.9 (7.5) 12.6 (5.0) 2872004 97-144 12 196 (132) 16.1 (0.63) 24.2 (9.5) 16.1 (6.3) 2872008 SPECIFICATION SHEET EVO-360-EN PAGE 3

specifications Sag and Tension Information Installation NESC Light NESC Medium NESC Heavy Fiber Span Tension Tension Tension Tension Count m (ft) Sag % N (lbf) Sag % N (lbf) Sag % N (lbf) Sag % N (lbf) 2-72 15 (50) 1.0 174 (39) 0.4 488 (110) 1.7 694 (156) 2.4 1028 (231) 30 (100) 1.0 348 (78) 0.5 852 (191) 2.0 1179 (265) 2.9 1711 (385) 46 (150) 1.0 522 (117) 0.5 1173 (264) 2.2 1602 (360) 3.2 2300 (517) 61 (200) 1.0 696 (156) 0.5 1472 (331) 2.3 1989 (447) 3.5 2836 (637) 76 (250) 1.0 870 (195) 0.6 1754 (394) 2.5 2353 (529) 3.7 3336 (750) 91 (300) 1.0 1043 (235) 0.6 2025 (455) 2.6 2699 (607) 3.9 3810 (857) 107 (350) 1.0 1217 (274) 0.6 2287 (514) 2.7 3032 (682) 122 (400) 1.0 1391 (313) 0.6 2542 (571) 2.8 3354 (754) 137 (450) 1.0 1565 (352) 0.7 2790 (627) 2.9 3667 (824) 152 (500) 1.0 1739 (391) 0.7 3034 (682) 2.9 3972 (893) 168 (550) 1.0 1913 (430) 0.7 3274 (736) 183 (600) 1.0 2087 (469) 0.7 3509 (789) 73-96 15 (50) 1.0 230 (52) 0.5 577 (130) 1.6 780 (175) 2.3 230 (52) 30 (100) 1.0 460 (103) 0.5 1007 (226) 1.9 1328 (299) 2.8 460 (103) 46 (150) 1.0 690 (155) 0.6 1391 (313) 2.1 1809 (407) 3.1 690 (155) 61 (150) 1.0 920 (207) 0.6 1748 (393) 2.3 2251 (506) 3.3 920 (207) 76 (250) 1.0 1150 (259) 0.6 2088 (469) 2.4 2668 (600) 3.6 1150 (259) 91 (300) 1.0 1380 (310) 0.7 2415 (543) 2.5 3067 (689) 3.7 1380 (310) 107 (350) 1.0 1610 (362) 0.7 2732 (614) 2.6 3451 (776) 122 (400) 1.0 1840 (414) 0.7 3041 (684) 2.7 3823 (859) 137 (450) 1.0 2070 (465) 0.7 3344 (752) 2.8 4186 (941) 152 (500) 1.0 2300 (517) 0.7 3642 (819) 2.9 4541 (1021) 168 (550) 1.0 2530 (569) 0.7 3935 (885) 183 (600) 1.0 2760 (620) 0.7 4224 (950) Note: Longer spans available upon request. SPECIFICATION SHEET EVO-360-EN PAGE 4

specifications (continued) Sag and Tension Information Installation NESC Light NESC Medium NESC Heavy Fiber Span Tension Tension Tension Tension Count m (ft) Sag % N (lbf) Sag % N (lbf) Sag % N (lbf) Sag % N (lbf) 97-144 15 (50) 1.0 368 (83) 0.6 723 (163) 1.7 904 (203) 2.4 1274 (286) 30 (100) 1.0 737 (166) 0.6 1277 (287) 2.0 1559 (351) 2.8 2141 (481) 46 (150) 1.0 1105 (248) 0.7 1779 (400) 2.2 2143 (482) 3.1 2901 (652) 61 (200) 1.0 1473 (331) 0.7 2254 (507) 2.3 2688 (604) 3.4 3601 (809) 76 (250) 1.0 1842 (414) 0.8 2711 (610) 2.5 3208 (721) 3.6 4261 (958) 91 (300) 1.0 2210 (497) 0.8 3156 (710) 2.6 3709 (834) 3.7 4893 (1100) 107 (350) 1.0 2579 (580) 0.8 3591 (807) 2.6 4196 (943) 122 (400) 1.0 2947 (663) 0.8 4019 (903) 2.7 4672 (1050) 137 (450) 1.0 3315 (745) 0.8 4441 (998) 152 (500) 1.0 3684 (828) 0.8 4857 (1092) Note: Longer spans available upon request. SPECIFICATION SHEET EVO-360-EN PAGE 5

transmission performance * Assumes 1.0 db maximum total connector/splice loss. ** ITU 652.D compliant. Notes: 1) Improved attenuation and bandwidth options available. 2) Bend-insensitive single-mode fibers available on request. 3) Contact Corning Cable Systems Customer Service Representative for additional information. Optical Fiber 62.5 50 50 50 Type (µm) Multimode Multimode Multimode Multimode Single-mode** Single-mode** ISO/IEC OM1 OM2 OM3 OM4 OS2 OS2 11801 Nomenclature Fiber Code K T T T E E Performance 30 31 80 90 01 00 Option Code Wavelength 850/1300 850/1300 850/1300 850/1300 1310/1383/1550 1310/1383/1550 (nm) Maximum 3.4/1.0 3.0/1.0 3.0/1.0 3.0/1.0 0.4/0.4/0.3 0.35/0.35/0.25 Attenuation (db/km) (db/km) Minimum 200/500 700/500 1500/500 3500/500 / / / / Over Filled Launch (OFL) Bandwidth (MHz km) Minimum 220/ 950/ 2000/ 4700/ / / / / Effective Modal Bandwidth (EMB) (MHz km) Serial 1 300/550 750/600 1000/600 1000/600 5000 / / 5000 / / Gigabit Ethernet Distance (m) Serial 10 33/ 150/ 300/ 550*/ 10000/ /40000 10000/ /40000 Gigabit Ethernet Distance (m) SPECIFICATION SHEET EVO-360-EN PAGE 6

ordering information Contact Customer Service at 800-743-2671 for other options. 1-3 Select fiber count (002 to 144). 4 N - T S A 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Select fiber code (see Transmission Performance table). 5 / 12 Defines cable type. N / A = SOLO Single- Jacket Cable See Note 1. 6 Select jacket. 4 = PE jacket (standard) A = TRPE jacket 7 Defines fiber placement. T = 12 fiber/buffer tube (standard) 8 Select length markings. 3 = Markings in meters 4 = Markings in feet (standard) 9 Defines tensile strength. S = SOLO Short-Span Cable 10-11 Select performance option code (see Transmission Performance table). 13-14 Defines special requirements. 20 = No special requirements Notes: 1) N/A defines SOLO Single- Jacket Cable and is not a reference to Not Applicable. 2) Use with buffer tube fan-out kit for direct termination applications. 3) Please contact Corning Cable Systems Engineering Services at 800-743-2671 for installation advice or information regarding mounting hardware. SPECIFICATION SHEET EVO-360-EN PAGE 7

notes Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. SOLO is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 2006, 2012 Corning Cable Systems. All rights reserved. Published in the USA. EVO-360-EN / April 2012 SPECIFICATION SHEET EVO-360-EN PAGE 8