2010/06 Subject to change Internet: www.festo.com/catalogue/... 81
Peripherals overview AS-interface topology 2 1 5 8 4 9 7 7 6 aa aj 8 7 + 9 ad ae 8 ac ad 9 9 ae ab 9 82 Internet: www.festo.com/catalogue/... Subject to change 2010/06
Peripherals overview Type Page/Internet 1 Industrial PC with fieldbus master 2 Power supply unit SVG1/20VAC-ASI-SA svg1 AS-i module ASI-EVA-2E2A-M12-8POL-Z as-interface 4 AS-i module ASI-EVA-4E-M12-5POL as-interface 5 AS-i module ASI-EVA-2E2A, 2E1A as-interface 6 Connecting cable KM12-8GD8GS-2-PU 54 7 Connecting cable KM8-M8-GSGD- 52 NEBU-M8-28 8 Flat cable KASI-1,5-Y-100 85 Cable socket ASI-SD 24 Plug socket FBSD-GD 21 9 Connecting cable NEBU-M12G5-F-0.2-M12G4 9 KM12-M12-GSGD 54 KM12 M12-GSWD- 54 KM12-DUO-M8-GDGD 54 aj Local controller DLP-VSE--5/-G-ASI as-interface aa Limit switch attachment DAPZ-SB-I-0DC-DSAM-RO dapz ab Cable distributor ASI-KVT-FKx2-M12 229 ac AS-i module ASI-8DI-M8-POL as-interface ad AS-i module ASI-4DIDO-M12X2-5POL-Z as-interface ae Connecting cable NEBV-B2WP 102 NEBV-C1WP 104 NEBV-Z2W2P 110 2010/06 Subject to change Internet: www.festo.com/catalogue/... 8
KASI-1,5, for AS-interface Technical data Flat cable KASI-1,5- -100 The flat cable is of a 2-wire design. The coding profile prevents polarity reversal of the cable. AS-interface network stations are connected to the flat cable via insulation displacement technology which utilises contact pins, thus eliminating the need to strip cable and wire insulation. The yellow cable is normally used for the AS-interface network and the black cable for the auxiliary power supply. Application Valve interfaces Designation Type CPV-ASI CPA-ASI MPA-ASI ASI-EVA ASI-EA VTSA/ VTSA-F AS-interface flat cable KASI-1,5-Y-100 AS-interface flat cable KASI-1,5-Z-100 Ordering data Bus connection Designation Cable length Cable colour Part No. Type AS-interface flat cable 100 m Yellow 18940 KASI-1,5-Y-100 AS-interface flat cable 100 m Black 18941 KASI-1,5-Z-100 84 Internet: www.festo.com/catalogue/... Subject to change 2010/06
KASI-ADR, for AS-interface Technical data Addressing cable for any slaves including Individual valve interface CP valve terminals Cable length 2.5 m Pre-assembled Reverse polarity protected General technical data Type Type KASI-ADR Connection type Plug-in/screw-in Connection cross section [mm 2 ] 2x 1.5 Protection class IP65 Straight plug materials Housing Polybutylene terephthalate Contacts Copper alloy Union nut Polybutylene terephthalate Angled plug materials Housing Polyurethane Contacts Bronze Union nut Nickel-plated brass Flat cable socket materials Housing Polyamide Contacts Bronze Cable sheath materials Rubber compound Ambient temperature [ C] 40 +85 Ordering data View Electrical connection Operating voltage range Acceptable current load [V AC] [V DC] [A] Type Part No. Straight plug, 4-pin Angled plug, 4-pin Straight socket, 2-pin 60 75 KASI-ADR 18 960 Dimensions Download CAD data www.festo.com 1 Round plug connector for connection to addressing device 2 Flat cable socket for connecting AS-interface network stations with plug-in connection Flat cable socket with M12 connection plug for AS-interface network stations with M12 interface 2010/06 Subject to change Internet: www.festo.com/catalogue/... 85
Accessories for KASI Ordering data Designation Part No. Type Cable sleeve (pack of 20) For insulating and sealing the AS-interface cable at the end of the string Protection class IP65 Shrinks on application of heat (hot air blower etc.) Cable cap for flat cable (pack of 50) For insulating and sealing the AS-interface cable at the end of the string Protection class IP65 16559 ASI-KT-FK 18787 ASI-KK-FK 86 Internet: www.festo.com/catalogue/... Subject to change 2010/06
KDI, for diagnostic interface Technical data Programming cable for different applications Pre-assembledatbothends Cable lengths m, 5 m, 6 m and 10 m KDI-SB202 KDI-SB60 General technical data Type KDI-SB KDI-PPA--BU9 Type of mounting M12 union nut/threaded connector, clip/2xm Screws 4-40 UNC screws Mounting position Any Operating voltage range [V] 00 AC Housing materials Polyester/polyurethane Contact materials Gold-plated copper base alloy Union nutmaterials Nickel-plated brass Cable sheath materials Polyurethane Polyvinyl chloride Ambient temperature [ C] 0 +80 Ambient temperature for flexible cable installation [ C] 10 +80 Ordering data Electrical connection Cable composition Cable diameter Product weight Cable length Type Part No. [mm 2 ] [mm] [g] [m] Straight socket, 5-pin, M12 straight socket, 25-pin, Sub-D Straight socket, 5-pin, M12 straight socket, 9-pin, Sub-D Straight plug, 5-pin, M12 straight socket, 8-pin, SDL 4x0.14 4.5. 6.5 210 5 KDI-SB202-BU25 0 47 4x0.14 4.5. 6.5 181 5 KDI-SB202-BU9 150 268 7x0.24 5.9 190 KDI-SB60-,0-M12 171 17 61 6 KDI-SB60-6,0-M12 175 686 591 10 KDI-SB60-10,0-M12 171 174 Straight socket, 9-pin, Sub-D straight plug, 9-pin, Sub-D 9x0.22 156 KDI-PPA--BU9 151 915 2010/06 Subject to change Internet: www.festo.com/catalogue/... 87
KDI, for diagnostic interface Technical data Dimensions KDI-SB60- Download CAD data www.festo.com L1 Cable length m, 6 m or 10 m KDI-PPA--BU9 1 Straight socket, 9-pin, Sub-D 2 Straight plug, 9-pin, Sub-D 88 Internet: www.festo.com/catalogue/... Subject to change 2010/06
KVI Technical data Connecting cable for fieldbus connection (valve terminal type 10 CPV and CPI installation system) Round plug Pre-assembledatbothends M9 plug/socket, 5-pin Straight/angled version in any combination Cable lengths 0.25 m, 0.5 m, 2 m, 5mor8m Suitable for use with energy chains General technical data Type KVI- Type of mounting M9 union nut Mounting position Any Operating voltage range [V] 60 DC Acceptable current load [A] 1.6 Cable composition [mm 2 ] 2x0.24, 2x0.4 and 0.49 Cable diameter [mm] 5.5 Protection class to EN 60529 IP65/67 (assembled) Note on materials RoHS-compliant Housing materials Polyurethane, nickel-plated brass Contact materials Gold-plated bronze/brass Cable sheath materials Polyurethane Ambient temperature for [ C] 5 +80 flexible cable installation Ambient temperature [ C] 20 +80 Corrosion resistance class CRC 1) 1 1) Corrosion resistance class 1 according to Festo standard 940 070 Components subject to low corrosion stress. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers. Ordering data Electrical connection Product weight [g] Cable length Type Part No. [m] Angled plug angled socket 4 0.25 KVI-CP--WS-WD-0,25 540 27 Angled plug angled socket 45 0.5 KVI-CP--WS-WD-0,5 540 28 Angled plug angled socket 116 2 KVI-CP--WS-WD-2 540 29 Angled plug angled socket 256 5 KVI-CP--WS-WD-5 540 0 Angled plug angled socket 99 8 KVI-CP--WS-WD-8 540 1 Straight plug straight socket 114 2 KVI-CP--GS-GD-2 540 2 Straight plug straight socket 255 5 KVI-CP--GS-GD-5 540 Straight plug straight socket 97 8 KVI-CP--GS-GD-8 540 4 2010/06 Subject to change Internet: www.festo.com/catalogue/... 89
KVI Technical data Dimensions KVI-CP--WSWD- Download CAD data www.festo.com 1 Cable length 0.25 m, 0.5 m, 2m,5m,or8m KVI-CP--GSGD- 1 Cable length 2 m, 5 m or 8 m 90 Internet: www.festo.com/catalogue/... Subject to change 2010/06
KVI Connection options for CP installation system Fieldbus Direct with CP string extension CPV valve terminal Fieldbus 4 to 8 valve positions DeviceNet CANopen Profibus DP ABB CS1 Interbus Moeller Suconet Festo fieldbus Beckhoff CC-Link 4 to 16 solenoid coils More information Internet: type 10 CPA-SC Fieldbus 4to24valvepositions DeviceNet connection Profibus DP 4 to 2 solenoid coils More information Internet: cpasc CPV-SC Fieldbus 4to16valvepositions DeviceNet connection Profibus DP 4 to 16 solenoid coils More information Internet: type 80 CDVI-DN Fieldbus 4 16 valve positions DeviceNet connection 4 to 24 solenoid coils In More information Internet: type 15 Out 0 1 2 4 5 6 7 2010/06 Subject to change Internet: www.festo.com/catalogue/... 91
KVI Connection options for CP installation system Axis controller SPC200 with CP interface Fieldbus In Max. 64 inputs and 64 outputs via fieldbus DeviceNet, Interbus or Profibus connection Out 4 5 2 0 1 More information Internet: spc200 6 7 Compact Vision System SBOC-Q/SBOI-Q with CP interface The Compact Vision System SBOx-Q can be integrated into a Festo CPI network. In this case it functions like a binary module with 16 inputs and outputs. In combination with a CPX-CPI module and a CPX fieldbus, for example, the camera can be accessed via Profibus DP, Interbus, DeviceNet, CANopen and CC-Link. Address requirement: 16 digital inputs/outputs CPI connection More information Internet: sboc-q, sboi-q 92 Internet: www.festo.com/catalogue/... Subject to change 2010/06
KV-M12, for diagnostic interface Technical data Plug socket with cable for diagnostic interface (to terminal CPX) Pre-assembledatbothends Cable lengths 1.5 m and.5 m 5-pin/4-wire Round plug General technical data Type KV-M12-M12- Typeofmounting Union nut M12 Mounting position Any Operating voltage range [V] 0 AC [V] 6 DC Acceptable current load [A] 4 Cable diameter [mm] 5 Protection class to EN 60 529 IP67 (assembled) Housing materials Polyurethane Contact materials Socket Gold-plated brass Plug Gold-plated bronze Union nut materials Nickel-plated/chrome-plated brass Cable sheath materials Polyurethane Ambient temperature [ C] 25 +70 Ambient temperature for flexible cable installation [ C] 5 +70 Ordering data Electrical connection Straight plug straight socket, 5-pin Cable Product weight Cable length Type Part No. composition [mm 2 ] [g] [m] 4x0.4 97 1.5 KV-M12-M12-1,5 529 044 Straight plug straight socket, 5-pin 4x0.4 182.5 KV-M12-M12-,5 50 901 2010/06 Subject to change Internet: www.festo.com/catalogue/... 9
KV-M12, for diagnostic interface Technical data Dimensions KV-M12-M12- Download CAD data www.festo.com 1 Cable length 1.5 m or.5 m Circuitry (socket/plug view) KV-M12-M12- Socket Circuitry Plug Brown Blue White Black Screened 94 Internet: www.festo.com/catalogue/... Subject to change 2010/06