Multimedia Electronics LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS 5 VERSIONS FOR EVERY REQUIREMENT
Antenna Measuring Technology By Professionals for Professionals The UPM Range for CATV, and Terrestrial User-friendly, pioneering and precise - great descriptions for the Hirschmann level measuring equipment for analogue and digital signals in all areas. Depending on the requirements and main focus of work, you can choose between five demand-based equipment versions. UPM 3300 RC, BC,, DVB-C, DVB-T, DVB-S UPM 3100 RC, BC,, DVB-C, DVB-T, DVB-S UPM 1600 BC,, DVB-C, DVB-T, DVB-S UPM 900, DVB-T, DVB-S The UPM 3300, 3100 and 1600 devices are available as a handy set incl. MPEG2 decoder, DVB-T front-end, leather case and battery. SPM 1 DVB-S
UPM 3300 UPM 3300 RC, BC,, DVB-C, DVB-T, DVB-S 948 404-001 5-2150 MHz VHF/TV 20-126 dbµv 40-126 dbµv Reverse channel/if 30-126 dbµv Measuring accuracy +/- 1.5 db (20 C) +/- 2.5 db (0-40 C) Colour TV standards PAL/SECAM/NTSC TV standards Standard B/G, I, L, M/N, D/K 5.5" TFT colour display Level measurement for QPSK and QAM BER for QPSK and 16/32/64/128/256 QAM MER for 10-38 db Constellation diagram MPEG-2 decoder* SI evaluation/nit* COFDM front end for DVB-T* S/N with Scope/Brumm* CI interface 2 x CI for CA module* Installed speaker Stereo socket for headphones audio subcarrier Sound measurement Separate measurement AC 1 and AC 2 NICAM audio carrier measurement* ADR audio carrier measurement optional* audio IF frequency 5.00-9.75 MHz in 10 khz stages freely adjustable Digital analyser with reversible measuring band widths for broadband and narrowband representation in all ranges Printer 24 character thermal printer 200 tuning memory spaces 24.5k measured value memory Remote feeding voltage/lnc Feeding voltage 10-20 V in 0.1 V stages/diseqc 1.0 and 2.0 22kHz connection/terr. Remote Measuring the LNC current IEC socket /75 Ohm (DIN 45 325) 100-250 V mains operation/12 V internal/external battery 12 V/2.2 Ah (2nd battery optional) 7.2 kg with a battery 365 x 150 x 285 mm Protection class II according to VDE 0411 * Not included in the delivery scope. Available as an option. TFT Colour Display 5.5" 24 character thermal printer 5-2150 MHz Teletext can be called up for every channel DiSEqC 1.0, 1.2, 2.0, 2.2 Trilingual function display with backlighting Water and dirt-resistant keyboard 12-V socket connection internal/external Stereo headphones connection 12 V/2.2 Ah battery installed as standard (plus retrofitting option with additional battery) Accessories included in scope of delivery - Mains cable - Measurement cable IEC-IEC - RF and F adapter - Printer paper roll Additional equipment (optional): - MPEG-2 decoder incl. NIT evaluation - COFDM front end for DVB-T - S/N measurement module - S/N measurement module with SCOPE/BRUMM - ADR decoder / NICAM decoder - Protocol software - Leather case - 2 x CI for all standard CA modules This top model is suitable for measuring VHF, TV, CATV, and reverse channel signals. It enables bit error rate measurements (BER) before and after Viterbi for QPSK and 16/32/64/128 QAM, constellation diagrams and modulation error measurements (MER). All standard interfaces can be used: MPEG 2 (optional), RS-232, RDS output and Scart. Pioneering technology and great user-friendliness are combined in the UPM 3300 all-round talent. Sync pulse line 17 in video signal. Constellation diagram of a QPSK signal.
UPM 3100 VHF/TV Reverse channel/if Measuring accuracy Colour TV standards TV standards CI interface Sound measurement audio IF frequency Printer Remote feeding voltage/lnc Protection class UPM 3100 RC, BC,, DVB-C, DVB-T, DVB-S 948 407-001 5-2150 MHz 20-126 dbµv 40-126 dbµv 30-126 dbµv +/- 1.5 db (20 C) +/- 2.5 db (0-40 C) PAL/SECAM/NTSC Standard B/G, I, L, M/N, D/K 5,5" b/w screen Level measurement for QPSK and QAM BER for QPSK and 16/32/64/128/256 QAM MER for 10-30 db Constellation diagram MPEG-2 decoder* SI evaluation/nit* COFDM front end for DVB-T* S/N with Scope/Brumm* 2 x CI for CA module* Installed speaker Stereo socket for headphones audio subcarrier Separate measurement AC 1 and AC 2 NICAM audio carrier measurement* ADR audio carrier measurement optional* 5.00-9.75 MHz in 10 khz stages freely adjustable Digital analyser with reversible measuring bandwidths for broadband and narrowband representation in all ranges 24 character thermal printer* 200 tuning memory spaces 24k measured value memory Feeding voltage 10-20 V in 0.1 V stages/diseqc 1.0 and 2.0 22kHz connection/terr. Remote Measuring the LNC current IEC socket /75 Ohm (DIN 45 325) 100-250 V mains operation/12 V internal/external battery 12 V/2.2 Ah (2nd battery optional) 6.9 kg with a battery 365 x 150 x 285 mm II according to VDE 0411 5-2150 MHz Teletext can be called up for every channel DiSEqC 1.0, 1.2, 2.0, 2.2 Trilingual function display with backlighting Water and dirt-resistant keyboard 12-V socket connection internal/external Stereo headphones connection 12 V/2.2 Ah battery installed as standard (plus retrofitting option with additional battery) Accessories included in scope of delivery - Mains cable - Measurement cable IEC-IEC - RF and F adapter Additional equipment (optional): - Printer - Further options as UPM 3300 This high-quality device offers all of the measuring functions, interfaces and additional options of the top model UPM 3300. With its high-resolution 5.5" black and white screen, it is especially suitable for measuring CATV signals, but also for the fields of VHF, and terrestrial. * Not included in the delivery scope. Available as an option.
UPM 1600 VHF/TV Measuring accuracy Colour TV standards TV standards Sound measurement audio IF frequency Remote feeding voltage/lnc Protection class UPM 1600 BC,, DVB-C, DVB-T, DVB-S 940 013-001 47-2150 MHz 20-126 dbµv 40-126 dbµv +/- 1.5 db (20 C) +/- 2.5 db (0-40 C) PAL/SECAM/NTSC Standard B/G, I, L, M/N, D/K 5,5" b/w screen Level measurement for QPSK and QAM BER for QPSK and 16/32/64/128/256 QAM MER for 10-30 db MPEG-2 decoder* SI evaluation/nit* COFDM front end for DVB-T* Installed speaker audio subcarrier Measurement AC 1 5.00-9.75 MHz in 10 khz stages freely adjustable Analogue analyser for for broadband and narrowband representation in all ranges 50 tuning memory spaces Feeding voltage 14/18 V DiSEqC 1.0/2.2 22kHz connection Measuring the LNC current IEC socket /75 Ohm (DIN 45 325) 100-250 V mains operation/12 V internal/external battery 12 V/2.2 Ah (2nd battery optional) 6.8 kg with a battery 365 x 150 x 285 mm II according to VDE 0411 B/w screen 5.5" 47-2150 MHz DiSEqC 1.0, 1.2, 2.0, 2.2 Trilingual function display with backlighting Water and dirt-resistant keyboard 12 V voltage output Accessories included in scope of delivery - Mains cable - Measurement cable IEC-IEC - Adapter - F plug Additional equipment (optional): - MPEG-2 decoder incl. NIT evaluation - COFDM front end for DVB-T - 12 V/2.2 Ah battery - Leather case This level measuring device for analogue and digital TV has an analogue analyser with quick automatic wobble function in all areas. DiSEqC 1.0/2.2 and the frequency ranges 0/22 khz can be adjusted. At just 6.8 kg, the device is especially light and handy. * Not included in the delivery scope. Available as an option.
UPM 900 DVB-T DVB-T Measuring accuracy CI interface audio IF frequency DVB-T Remote feeding voltage/lnc DVB-T Protection class UPM 900, DVB-T, DVB-S 940 143-001 174.0-867.5 MHz (E 5-E 69) 910-2150 MHz 25-110 dbµv 30-110 dbµv +/- 1.5 db (20 C) +/- 2.5 db (0-40 C) 4" TFT colour display Level measurement for QPSK and QAM BER for QPSK and 16/64 QAM MPEG-2 decoder SI evaluation/nit COFDM front end for DVB-T S/N PCMCIA shaft for CA module Installed loudspeaker 5.00-9.99 MHz in 10 khz stages freely adjustable No analyser function Real time analyser with vertical frequency axis 99 station memory Feeding voltage 5/18 V Current measurement 0-100mA Feeding voltage 14/18 V DiSEqC V1.0, V1.1, V1.2, V2.0, V2.2 22kHz connection Measuring the LNC current IEC socket /75 Ohm (DIN 45 325) 100-250 V mains operation/50-60 Hz/2 V external NI-MH battery 12V/4.5 Ah approx. 3.5 kg with integral battery pack 252 x 135 x 272 mm II according to VDE 0411 910-2150 MHz DVB-T 174.0-867.5 MHz DiSEqC V1.0, V1.1, V1.2, V2.0, V2.2 4" TFT colour display Operation via membrane keyboard and rotary pulse encoder With installed Ni-MH battery pack 12 V/4.5 Ah Installed speaker 99 station memory real time analyser with vertical frequency axis The compact combined measuring device to measure levels convinces with its functionality and value for money. Can be used for all measurements in the field of analogue, digital and DVB-T. With a measuring accuracy of +/- 1.5 db (at 20 C) or +/- 2.5 db (at 40 C) it offers reliability. Its compact dimensions ensure practical handling in mobile use. NIT (SI evaluation) Real time analyser
SPM 1 Remote feeding voltage/lnc SPM 1 DVB-S 940 140-001 950-2150 MHz 34-90 dbµv Level measurement QPSK Bar display 62 station memory Feeding voltage 13/18 V DiSEqC 1.0 22kHz connection F Connector/75 Ohm unit 230 V/12/17V external battery NI-MH, 9.6V/2.2 Ah approx. 1.5 kg 120 x 60 x 235 mm Automatic satellite selection Pre-programmed for 20 different orbit positions Total of 62 channels, can be reprogrammed at any time over PC (option RS 232 adapter) Simultaneous display of level and signal quality With sound signal when good signal quality is achieved DiSEqC 1.0 DVB Standard DVB/DSS Off-line operation for up to 5 hours With sturdy protective case The handy digital satellite level measuring device for quick and optimum alignment of satellite antennas. The automatic satellite selection independent finds the right satellites by pre-selecting a desired, preprogramme channel. Weighing just 1.5 kg and with compact dimensions, it is especially handy and practical.
Data Comparison UPM 3300 UPM 3100 UPM 1600 UPM 900 SPM 1 Constellation diagram SI evaluation/nit S/N /digital /analog Terr./digital CATV Reverse channel TFT colour display B/w screen 948 404-001 948 407-001 940 013-001 940 143-001 940 140-001 S/N with Scope/Brumm CI interface Sound measurement NICAM audio carrier measurement Printer Standard Option ADR
Hirschmann Multimedia Electronics GmbH Stuttgarter Straße 45-51 72654 Neckartenzlingen/Germany Telephone: +49 180 3232 341 Fax: +49 7127 14-1699 www.hirschmann.com DS 280 220-170 Printed in Germany. 50/49/Ae/0505. Turnover tax ID No.: DE 813688802. Subject to printing errors, mistakes and changes.