INFORMATION FOR VISITING COMPANIES

Similar documents
Technical Specification

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

DEREHAM MEMORIAL HALL

Theatre Technical Specifications

New Theatre Royal Lincoln Technical Information

Matt Dann Cultural Centre

Technical Specification for the Alley Theatre, Strabane

Technical Information

HIRE AND TECHNICAL INFORMATION

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

TECHNICAL SPECIFICATION

Dr JOHN GALLAGHER CONCERT CHAMBER

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Stage. Get In & Parking

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Technical Specification Ardhowen Theatre

Main House Technical Specification

TECHNICAL SPECIFICATIONS

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Theatre Technical Specification

Technical Specifications Updated 01/10/2017. Stage

The Haymarket Basingstoke Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

CHELSEA THEATRE. Technical Specifications

Main House Technical Specifications

The Georgian Theatre Royal Technical Information For Visiting Companies

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

UNIVERSITY CONCERT HALL. Technical Specification

TECHNICAL SPECIFICATIONS

Technical specifications Main theatre. Sound

Pleasance London Main House Visiting Company Information Pack May 2017

Technical Specifications

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Technical Specification Pavilion Dance

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specifications Nov 2016

ISLAND HALL TECHNICAL INFORMATION

CENTRE FOR PERFORMING ARTS

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Arlington Arts Tech Spec 2018

Latrobe Performing Arts Centre

Technical Specification

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

JERWOOD VANBRUGH THEATRE

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

MAIN THEATRE TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Specification. Updated: April 2016

Technical Specifications

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Lighthouse Theatre Technical Specification

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

2017 TECHNICAL SPECIFICATIONS

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Summary. Access and Parking

Cornerstone Technical Specifications 2018 / V1

Hirers Technical Information Pack

Technical Specification Ver 01/16

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

Rhodes Arts Complex Bishops Stortford. Technical Specifications

The Lights Technical Guide June 2017

THEATRE ROYAL MARGATE Technical Specification April 2018

John Leslie Theatre. Technical Specifications. Updated July 2018

THE STREET THEATRE. Technical Specifications

THEATRE ROYAL MARGATE Technical Specification January 2016

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

HIRERS INFORMATION PACK For further technical information or enquiries please contact:

Esso BHP Billiton Wellington Entertainment Centre

Information for Incoming Companies

Monash University Academy of Performing Arts

Hopgood Theatre NOARLUNGA CENTRE

Monash Academy of Performing Arts

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Technical requirements & conditions for hirers

MAIN AUDITORIUM TECHNICAL INFORMATION

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

DRAÍOCHT Technical Specification: MAIN SPACE

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Dugdale Centre Technical Specification

Technical Information

Theatre Technical Specifications

Technical Pack. Attenborough Arts Centre

Compass Theatre - Technical Information Pack

Shouson Theatre Venue Specifications (updated Jan 2017)

Access to back stage is off Fletcher St on the eastern side of the building

Technical Specifications. Taylor Little Theater

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Darlington Hippodrome Technical Specification

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

MONASH University Academy of Performing Arts

Transcription:

INFORMATION FOR VISITING COMPANIES

2 Middlesbrough Theatre The Avenue Linthorpe Middlesbrough TS5 6SA ADMINISTERED BY MIDDLESBROUGH COUNCIL CULTURAL SERVICES Touring Drama, Dance, Music and Opera, Amateur Productions, Private Hire, Conferences, Promotions etc. Theatre Manager: Senior Technician: Marketing: Admin: Technical Team: David Lindsey (David_Lindsey@middlesbrough.gov.uk) Tel: (01642) 842290 Andy Charlesworth (Andrew_Charlesworth@middlesbrough.gov.uk) Tel: (01642) 358067 David Kime (David_Kime@middlesbrough.gov.uk) Tel: (01642) 358069 Kesia Train (Kesia_Train@middlesbrough.gov.uk) Tel: (01642) 358069 theatretechnicians@middlesbrough.gov.uk Box Office: Tel: (01642) 81 51 81 Fax: (01642) 818947 Seating capacity: 486 (Stalls 222, Boxes 26, Circle 238)

3 Stage Proscenium width 25 9 (7.86m) Proscenium height 14 0 (4.28m) Depth of stage 39 0 (11.12m) Grid height 25 5 (6.75m) Wing width 14 5 (4.4m) Orchestra Pit 25 9 x 8 8 accommodating approx. 20 Prompt Desk Flying system Stage floor Loading doors Stage Left 23 x 3 fall hemp sets Fly floor Stage Left All fly bars 12m long x 48mm O.D. SWL 150kg each, evenly distributed. Black hardboard, no rake. Stage Right at 1 9 above road level (Ramp available) Backstage Accommodation Stage Left Ground floor: Green Room First floor: Manager s office Second floor: Dressing Room 2 (4 persons) Dressing Room 3 (10 persons) Stage Right Ground floor: Dressing Room 4 (10 persons) First floor: Dressing Room 5 (10 persons) Second floor: Dressing Room 6 (10 persons) There are hand basins in all dressing rooms and toilets next to each. Showers are on the first floor on both sides. Dressing room 2 can be used as a company office and has a dedicated telephone line. Calls will be recharged to the visiting company. There is no Wi-Fi service in the theatre. Laundry facilities, kettle, microwave, fridge and washing-up facilities are located in the Green Room. Ironing boards & irons are available. Please advise all your company members that all dressing room doors are fire doors and must not be propped open. Smoking, including e-cigarettes, is not allowed anywhere in the building (including as part of a performance) or in the immediate vicinity of the building. Alcohol is not allowed in any backstage area or in dressing rooms at any time.

4 Lighting and Sound control rooms, and follow spot positions, are located behind the rear circle. A rear-stalls position (not central) is available, with coms and DMX lines only, no sound tie lines. Multicore run to this position is 25 metres. Please advise when booking if this position is required so those seats can be taken off sale. Fobs are available for access between backstage and FOH and the lighting and sound control rooms. These must be returned at the end of each performance, or the cost of replacements will be recharged to the visiting company. The fire safety curtain is fully automatic, linked to the detection and alarm system. Stage and auditorium detection can be isolated during performances to allow for use of smoke, haze and pyros. Lighting Control Dimming ETC Ion with 2 x 20 Fader Wing and Net3 Radio Focus Remote. 96 channels of Zero88 Chilli Pro 3-phase dimming, on one DMX universe. (48 channels with Bypass switching) All stage LX bars are 12 metre long, 48mm o.d. 12 circuit IWB s, SWL 500kg. Lanterns normally available 36 x Stand Patt743 1Kw 6 x Strand Patt243 1Kw 36 x Thomas Parcan 1Kw (CP62 only) 4 x Strand Cantata 18/32 1.2Kw 12 x Strand Coda Floods 1Kw 6 x Short-Nose Floor can (CP62 only) 14 x ETC Source Four 15/30 Zoom (On FOH Bar only) 12 x Selecon Acclaim Axial 18/34 Zoom 8 x Selecon Acclaim Axial 22/44 Zoom (Please note Selecon profiles take a size M gobo only) Stage Power Stage right Stage left Prompt Corner: 14 x 13A Sockets 16 x 13A Sockets 3 x 32A Single Phase 1 x 63A Three Phase 1 x 125A Three Phase The supplies at prompt corner are RCD protected and are set to trip at 300mA. Please note that the RCD WILL NOT be by-passed under any circumstances.

5 Sound Control Allen & Heath GL2400 32ch FOH speakers 2 x Turbosound TQ 310 DP 700W Powered Speakers 2 x Turbosound TQ 308 DP 500W Powered Speakers 2 x Turbosound TQ 425 DP 1600W Powered Subs 2 x Nexo PS 10 as circle fill only Stage monitors 4 x Martin Audio LE400 2 x HK Audio Pro12M 800w Amps 2 x Channels Phonic MCX2500 (Nexo PS10 s only) 4 x Channels Crown XLi2500 2 x Channels Crown XLS602 Outboard 1 x Yamaha SPX 900 1 x Sabine FBX 901 Feedback Exterminator 2 x Behringer Multicom Pro XL 4 Way Compressors 2 x Behringer Ultragraph Pro 31 band EQ 2 x Rane ME30B 30 band EQ (FOH) Microphones normally available 6 x Sennheiser E845 4 x Shure SM 58 2 x Shure SM 57 3 x Audio Technica Pro 27 HE 1 x Shure PG58 2 x Crown PCC 160 Boundary 1 x JTS NX2 2 x Rode NT5 1 x Shure PGDMK4 drum kit set No Radio Microphones (Hire prices available on request) Mic inputs 8 each side, rear of proscenium wall and 10 in orchestra pit. Various speaker tie lines onstage and in the auditorium. Line level inputs on stage and orchestra pit

6 Communications Show relay to all dressing rooms, Green Room, lighting and sound control rooms Techpro beltpacks and headsets between stage desk, stage right, sound control room, lighting control room, fly floor, follow spots and rear of stalls. Telephone between stage desk, box office, company office, manager s office, sound control room, lighting control room, green room and bar. Stock scenery and equipment 5 no. 40 x 6 Black wool serge borders for top masking 8 no. 16 x 8 Black wool serge flats for side masking. Hard masking only, no legs available 2 pairs 18'6" drop x 20' wide Black wool serge Tabs Various adjustable braces and stage weights Various straight and boom mic stands 20 no. RAT lit music stands 20 no. Black orchestra chairs Additional equipment available to hire Bechstein Grand piano Broadwood Upright piano 2 x LDR Canto 1200MSR Follow Spots 20 x 40 Fibre optic Star Cloth 6 x Martin Mac500 20 x Chauvet LED SlimPar Various sizes of Steeldeck and legs Hazer Smoke machine Mirror Ball Projector & Screens UV cannons Le Maitre pyro controller and pods 13/09/17