Web-based inspections in industrial radiography

Similar documents
Ride the Lightning. A Review of Radiographic Physics

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

Quality Control. Chapter 23

SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

Logo Usage Guide TUV AUSTRIA TURK. Guide for document designs Rev. 04 / GUI-001a Rev.4 /

EUROPEAN COMMISSION. Dear Ms Bohdal, dear Mr Stelzl,

Building Your DLP Strategy & Process. Whitepaper

Safety Considerations For The Top-up Operation Of An 8 GeV Class Synchrotron Radiation Facility

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

What is TEMPEST Chapter 1

Mosby's Exam Review For Computed Tomography, 2e Ebooks

ATV-HD Project Executive Summary & Project Overview

New appraoch for X-ray weld inspection of pipeline segments

WG H Container X-Ray Scanning Portal

User Guide. Centrex Recording Interface

RG NDT INTERNATIONAL INC

Toronto Hydro - Electric System

Kramer Electronics, Ltd. USER MANUAL. Model: VS x1 Video Audio Switcher

ADDENDUM PAGES: Revised Locked-Rotor Current Ratings in NEMA ICS 2 Part 2 Based on NEC 2002 and NEMA MG 1

RPV and Primary Circuit Inspection. Pressure Vessel Inspection Codes for phased Arrays M. Moles, Olympus NDT, Canada

Rev. 01 February 2014 X- RAY SAFETY MANUAL

EMI/EMC diagnostic and debugging

DEPARTMENT CIRCULAR No. Series of 2017

Documentation. Magnetic Encoder System (MES) Version: Date:

VENDOR MANUAL VERSION 2.0. SECTION 8 Quality Assurance Requirements

SERVICE BULLETIN MANDATORY SB EFFECTIVITY SERIAL NUMBERS G36 (Bonanza) E-4076 thru E-4079, E-4084

-Technical Specifications-

Model 1421 Distribution Amplifier

CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145

NOTIFICATION OF A PROPOSAL TO ISSUE A CERTIFICATION MEMORANDUM

Equipment Quality Control for Primary Displays June 5, Imaging Physics CancerCare Manitoba

GUIDELINES FOR PREPARATION OF ARTICLE STYLE THESIS AND DISSERTATION

Kramer Electronics, Ltd. USER MANUAL. Model: VS-33Vxl. 3x1 Video Switcher

VAR Generator Operation for Maintaining Network Voltage Schedules

School of Music FOR ENTRY IN FALL 2017

SELF STORAGE. Self Service Kiosks for. Always on Duty! 24 Hour Sales & Support Remote Monitoring Added Security

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

IMS Brochure. Integrated Management System (IMS) of the ILF Group

Accessing Information about Programs and Services through a Voice Site by Underprivileged Students in Education Sector of Sri Lanka

Theatre Bay Area General Auditions FAQ (for actors)

March 9, Legal Memorandum. ATSC 3.0 Notice of Proposed Rulemaking: Comments Due May 9; Reply Comments Due June 8

Guidelines for ASEAN Digital Switch-Over

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC

10 Quick Wins to Increase HUBZone Scorecard Percentages

SC26 Magnetic Field Cancelling System

Why We Measure Loudness

Digital Television Switchover. Michael Starks for Jamaica Broadcasting Commission

User s Manual. Document # , Rev 1.2, 6/12/2006

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

ELIGIBLE INTERMITTENT RESOURCES PROTOCOL

Advanced DisplayPort Testing. Lexus Lee Program Manager

46 th ANNUAL MINNESOTA RENAISSANCE FESTIVAL Craft Application Information

SUMMARY REPORT. Consultation Summary Report. January 2016

Colour Explosion Proof Video Camera USER MANUAL VID-C

FAR Part 150 Noise Exposure Map Checklist

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

THE ANGMERING SCHOOL CCTV POLICY. The Angmering School CCTV Code of Practice Version 1, 15/02/12, Created by Marc Ginnaw.

FiberLink 7142 Series

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200Dxl. XGA Differential Amplifier / DA

BEREC Opinion on. Phase II investigation. pursuant to Article 7 of Directive 2002/21/EC as amended by Directive 2009/140/EC: Case AT/2017/2020

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Coding of moving video

AUTOMATIC TRANSFER SWITCHES. Product Guide

HyPrecision Waterjet. Optimizing waterjet performance

PEP-II Overview & Ramp Down Plan. J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007

RG NDT INTERNATIONAL INC. Drill Pipe and Tubing Inspection System

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

RECOGNITION OF PRIOR LEARNING CANDIDATE APPLICATION FORM UEE30811 CERTIFICATE III IN ELECTROTECHNOLOGY - ELECTRICIAN

EDDYCHEK 5. Innovative eddy current testing for quality and process control. Touchscreen. Networking. All major applications.

Certification Scheme

City of Charlottesville Bicycle and Pedestrian Master Plan Update

Panel Discussion: Personal Safety and Human Factors

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

American National Standard for Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures

HyPrecision Waterjet. Optimizing waterjet performance

ex 800 Series ematrix System

Environmental Technology Verification Report

Packaged Designs, Products & Solutions

Monitor QA Management i model

MATLAB & Image Processing (Summer Training Program) 4 Weeks/ 30 Days

CENTRE OF TESTING SERVICE INTERNATIONAL

One (1) fiber Detachable HDMI Extender

Open Rack Specification 2.1 Update

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

2008 Conference INMATE VIDEO VISITATION. What Is It, Why Use It, And How!

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Requirements for the Beam Abort Magnet and Dump

Effectively Managing Sound in Museum Exhibits. by Steve Haas

TRANSITIONING TO DIGITAL RADIOGRAPHY WHEN DOES IT MAKE SENSE? S.A. Mango, Aerial and Industrial Materials, Eastman Kodak Company, Rochester, USA

In-Line or 75 Ohm In-Line

Connection requirements for generators to distribution grid C10/11 CENELEC. 26 Oct 2016 Elia WG Belgian Grid

Texas Music Educators Association Region 20 - Band Division. Band Division

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-2L UXGA Line Amplifier. P/N: Rev 3

TV Translator Relocation Grant Program

Tahoma Chapter Auditions Handbook 2018 Guidelines, Procedures, Categories and Requirements for Teachers, Students and Accompanists

Kramer Electronics, Ltd. USER MANUAL. Model: VP-100. VGA/XGA to RGBHV Converter

IMPLEMENTATION OF SIGNAL SPACING STANDARDS

Transcription:

Web-based inspections in industrial radiography Digital inspections in an analogue world www.nrpa.no

IAEA-TECDOC-1526 (2007)

Industrial radiography in Norway

Hire the Flash Solution?

Solution? an army of inspectors

use The Internet. Solution?

Method Questionnaire sent to radiation protection officers (RPO) by e-mail. Unique link in e-mail leads RPOs to their company specific questionnaire online. Accompanying letter from NRPA emphasising that responding is obligatory, not voluntary. Questionnaire, e-mails, replies handled by EasyResearch.

Questionnaire 52 questions. Questions grouped thematically over 8 pages. Multiple choice or specific format to enable automated analysis. All questions had to be answered to be able to complete questionnaire.

Questionnaire 8 possible non-compliances. ( Does there exist written instructions for RPO? ) 9 possible notifications. ( What year were instructions for RPO revised? ) 22 requests for information. ( Number of devices for gamma radiography? ) 13 questions regarding substitution. ( To what extent can UT replace gamma/x-ray? )

Response timeline 0 1 2 3 4 5 6 7 8 9 10 16-1-2015 18-1-2015 20-1-2015 22-1-2015 24-1-2015 26-1-2015 28-1-2015 30-1-2015 1-2-2015 3-2-2015 5-2-2015 7-2-2015 9-2-2015 11-2-2015 13-2-2015 15-2-2015 17-2-2015 19-2-2015 21-2-2015 23-2-2015 25-2-2015 27-2-2015 1-3-2015 3-3-2015 5-3-2015 7-3-2015 9-3-2015 11-3-2015 13-3-2015 15-3-2015 17-3-2015 19-3-2015 21-3-2015 23-3-2015 25-3-2015 27-3-2015 29-3-2015 31-3-2015 2-4-2015 4-4-2015 6-4-2015 8-4-2015 10-4-2015 12-4-2015 Number of responses

Response timeline 80 70 67 70 60 57 50 40 30 20 10 0 Deadline 1 Deadline 2 Threat of fine

Results overview 70 questionnaires completed response rate 100 %. Updated information on radiography companies: 928 radiation protection certified operators. 255 gamma sources. 237 x-ray sources.

Results overview 25 20 Number of companies 15 10 5 0 1-2 3-5 5-10 10-20 20-30 Over 30 Number of operators Number of radiography operators is 10 or less for about two thirds of the companies

Results - overview 30 25 Number of companies 20 15 10 5 0 1 2 3-5 5-10 10-20 Over 20 Number of radiation sources (gamma and/or x-ray) Number of radiation sources is five or less for about two thirds of the companies.

Non-compliances distribution 60 53 50 Number of companies 40 30 20 12 10 5 0 0 1 2 Number of non-compliances 22 non-compliances were found at 17 companies, no company more than two.

Non-compliances causes Too high dose rate outside shielded enclosure. No written emergency procedures. No local log of gamma sources. No written procedure for radiography. Personal alarm monitor not available. Gamma souces not registered with the NRPA. No written instructions for the RPO. X-ray sources not registered with the NRPA. 0 2 4 6 8 10 12 Number of companies

Web-based vs on-site inspections 2 Number of non-compliances 1 0 A B C D E F G H I J K L M 13 companies were subjected to on-site inspections in parallel to the webbased ones. More non-compliances were found on-site, unsurprisingly.

Web-based vs on-site inspections Company D. In questionnaire, they confirmed having written procedures, thus in compliance. On-site these procedures were found sufficiently poor and outdated to warrant a non-compliance. Company F. Said in questionnaire that they were using a closed facility for radiography. On-site inspection revealed that this facility did not fulfill all conditions of a closed facility, and a non-compliance was issued. Company G. Gave a number of certified operators in questionnaire. Turned out on on-site inspection that one operator did not posess an accredited certificate in radiation protection.

Self reporting vs NRPA auditing Too high dose rate outside shielded enclosure. No written emergency procedures. No local log of gamma sources. No written procedure for radiography. Personal alarm monitor not available. Gamma souces not registered with the NRPA. No written instructions for the RPO. X-ray sources not registered with the NRPA. 0 10 20 30 40 50 60 Non-compliances from online inspection Non-compliances from registry audit

Self reporting vs NRPA auditing 300 250 200 150 100 50 0 Gamma Online Registry Application X-ray

Substitution Question: To what extent can gamma and/or x-ray be replaced by NDT methods which improve radiation protection? Six possible substitutions: 1. X-ray for gamma. 2. Ultrasound for gamma/x-ray. 3. Magnetic particle for gamma/x-ray. 4. Dye penetrant for gamma/x-ray. 5. Eddy current for gamma/x-ray. 6. Leakage testing for gamma/x-ray. Long story short: Only options 1 & 2 were considered viable.

How many gamma examinations could be performed with x-ray? All. Most of the examinations (more than 75 %). About half the examinations (25-75 %). Some examinations (up to 25 %). None. Impossible to say. 0 2 4 6 8 10 12 14 16 Number of companies About two thirds of the companies (64 %) believe that at least some gammaradiography can be replaced with x-ray radiography.

What prevents x-ray from replacing gamma radiography? Alternative impractical. Alternative method does not give desired results. Alternative method more expensive. The customers do not want alternative. No industrial standard for alternative. No in-house competence on the alternative. Other: Number of companies using argument 0 5 10 15 20 25 30 35 40 Main argument against x-ray radiography is acessability for relatively large equipment, poorer image quality and expense for customer (x-ray taking longer).

How many gamma/x-ray examinations could be performed with ultrasound? All. Most of the examinations (more than 75 %). About half the examinations (25-75 %). Some examinations (up to 25 %). None. Impossible to say. 0 5 10 15 20 25 30 Number of companies About half the companies believe that at least some gamma/x-ray radiography can be replaced with ultrasound.

What prevents ultrasound from replacing gamma/x-ray radiography? Alternative method does not give desired results. The customers do not want alternative. Alternative impractical. No industrial standard for alternative. Alternative method more expensive. No in-house competence on the alternative. Other: 0 10 20 30 40 50 60 Number of companies using argument The main problem with ultrasound replacing ionising radiation is that it cannot be applied in all situations (thickness of objects).

Substitution «conclusion»? There is potential for increasing use of x-ray to replace gamma and ultrasound to replace gamma/x-ray, and many companies phase out gamma for their own radiation protection purposes. Main obstacles for substitution are accessibility (size of x-ray) and applicability (object dimensions for ultrasound). Economical considerations may work against substitution, as x- ray takes longer, making it more expensive for customer. Technology developing rapidly, can authorities find incentives to speed substitution up?

Feedback time spent 50 45 40 Number of companies 35 30 25 20 15 10 5 0 < 1 h 1-2 h > 2 h Time to complete questionnaire

Feedback - usefulness 40 35 30 Number of companies 25 20 15 10 5 0 Very useful Somewhat useful Not useful

Conclusion Web-based inspections feasible response rate 100 %. Much data gathered quantity over quality. Future inspections may: Utilise feature of «conditional questions». Ask for attachment of documents (although currently not a feature in EasyResearch ). Method may also be applicable for inspections in other areas (veterinary, dentist, control sources, etc.)