www.osram-os.com OS-IN-2017-032 Customer Information Package OS QM CQM 15.08.2017 Light is OSRAM
Content of the Infonote 1) New Design of Datasheets 2) Glossary for Full Conversion yellow 3) Change of Viewing Angle Description 4) Revision of Tape and Reel Drawing 5) Revision of Dry Packing Note 6) Specification of Reverse Characteristics of Devices 7) Introduction of Corrosion Classes 8) Correction of Laser Classification 9) New Disclaimer 2 OS-IN-2017-032 15.08.2017
Reason for Change OSRAM Opto Semiconductors will adjust the layout and the information content of the datasheets to ensure a clearer structure and a higher benefit for the customer. In this Infonote we announce several changes which will be introduced from now onwards for Datasheet updates. 3 OS-IN-2017-032 15.08.2017
1) New Design of Datasheets Reason: To ensure a clearer structure and a higher benefit for the customer. Products affected: All OS products. 4 OS-IN-2017-032 15.08.2017
2) Glossary for Full Conversion yellow (LED only) 2a) Reduction of Measurement Tolerances for converted yellow Devices Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility of +/- 0.005 and an expanded uncertainty of +/- 0.01 (acc. to GUM with a coverage factor of k = 3). Chromaticity coordinates are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/- 0.001 and an expanded uncertainty of +/- 0.004 (acc. to GUM with a coverage factor of k = 3). Reason: Full conversion of blue light into yellow can be measured with a higher reproducibility compared to white light Products affected: LCY xxxx, KY DMLx31.FY 5 OS-IN-2017-032 15.08.2017
2) Glossary for Full Conversion yellow (LED only) 2b) Add typical dominant Wavelength in Datasheet for converted yellow Devices Show CxCy values Show CxCy values Show typical dominant wavelength Reason: Easier comparison of color between InGaAlP yellow and converted yellow devices Products affected: LCY xxxx, KY DMLx31.FY 6 OS-IN-2017-032 15.08.2017
3) Change of Viewing Angle Description Page 1 : Viewing angle at 50 % I V : xx Page 4: Viewing angle at 50 % Iv Page 1:Viewing angle: xx Page 4: Viewing angle at 50 % Iv Radiation Characteristics shows the typ. values Radiation Characteristics shows the typ. values Reason: Better fit to standard viewing angles Product affected: All packaged visible LED Products 7 OS-IN-2017-032 15.08.2017
4) Revision of Tape and Reel drawing Reason: Redundant information in combination with the tape drawing will be removed and tables will be updated accordingly. Tape dimensions are shown on the preceding page already. New reel drawing will focus only on the reel information in the future. No change of any dimensions. Product affected: All taped OS Products 8 OS-IN-2017-032 15.08.2017
5) Revision of Dry Packing Note Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter Tape and Reel under the topic Dry Pack. Here you will also find the normative references like JEDEC. Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card according JEDEC-STD- 033C. Reason: Included JEDEC-STD-033C reference in the Datasheet No change of dry packing specification Product affected: All dry packed OS Products 9 OS-IN-2017-032 15.08.2017
6) Specification of Reverse Characteristics of Devices Not designed for Reverse operation Specification of Reverse Voltage Specification for Reverse Current Reverse characteristics of possible ESD device Reverse Operation of 10 hours is permissible in total. Continuous Reverse Operation is not allowed. Reason: Benefit for the customer to have more information of the reverse characteristic. Product affected: all OS Products except General Lighting 10 OS-IN-2017-032 15.08.2017
6) Specification of Reverse Characteristics of Devices Examples for some devices: LW TVSG.BB LUW CEUN.CE LA T676 Reverse voltage V R (V R Based on Device Solderpads) Max. 1.2 V (I R = 20 ma) Max. 1.2 V (I R = 20 ma) 12 V (Max. Rating) Reverse voltage V R ESD (ESD device only) Min. 5 V (I R ESD = 5 ma) Min. 45 V (I R ESD = 5 ma) n.a. Reverse current I R 200 ma (Max. Rating) 200 ma (Max. Rating) Typ. 0.01 µa Max. 10 µa (V R = 12 V) 11 OS-IN-2017-032 15.08.2017
7) Introduction of Corrosion Classes Corrosion robustness: few information of corrosion robustness, test condition and recommendation for atmosphere of production and use. Specification of corrosion classes and grades A & B. See details on next page. (e.g. Test conditions: 40 C/90% r.h. / 15ppm H 2 S/336h=stricter than IEC 60068-2-43 (H 2 S) [25 C/75% r.h./10ppm H 2 S/21 days] =Regarding relevant gas (H 2 S) stricter than EN 60068-2-60 (method 4) [25 C/75% rh/200ppb SO 2, 200ppb NO 2, 10ppb Cl 2 /21 days]) (e.g. classification as grade 3B which stands for testing 40 C / 90 % r.h. / 15 ppm H 2 S / 14 days (stricter than IEC 60068-2-43) where discoloration is allowed) Reason: To ensure a clearer structure and a higher benefit for the customer. Product affected: All packaged OS products. 12 OS-IN-2017-032 15.08.2017
7) Introduction of Corrosion Classes OS Corrosion Class Grade A Grade B n.a. discoloration 0 None possible 25 C / 75 % RH / 200ppb SO 2, 200ppb NO 2, 10ppb H 2 S, 10ppb Cl 2 / 1 2 21 days (EN 60068-2-60 (Method 4)) 25 C / 75 % RH / 10 ppm H 2 S / 21 days (IEC 60068-2-43) No visible discoloration (Microscope: 50x magnification) discoloration possible (Microscope: 50x magnification) 3 40 C / 90 % RH / 15 ppm H 2 S / 14 days (stricter then IEC 60068-2-43) Grade A: Subcomponents of this LED contain, in addition to other substances, metal filled materials. Metal filled materials can be affected by environments that contain traces of aggressive substances. Therefore, we recommend that customers minimize LED exposure to aggressive substances during storage, production, and use. Grade B: Subcomponents of this LED contain, in addition to other substances, metal filled materials including silver. Metal filled materials can be affected by environments that contain traces of aggressive substances. Therefore, we recommend that customers minimize LED exposure to aggressive substances during storage, production, and use. LEDs that showed visible discoloration when tested using the described tests above did show no performance deviations within failure limits during the stated test duration. Respective failure limits are described in the IEC 60810. 13 OS-IN-2017-032 15.08.2017
8) Correction of Laser Classification Some IRED products do not have any eye safety classification acc. to IEC 62471 in product datasheet. Some IRED products are wrongly classified and labelled as laser class 1M, 3R or 3B (according to IEC 60825). SFH 4735, SFH 4735 E9603, SFH 4736, SFH 4736 E9603: Get eye safety class Moderate Risk (RG2) according to IEC 62471. All other IRED products get eye safety class N (0 - Exempt group) according to IEC 62471. Labeling on packing will change accordingly Notes: Laser classes defined for Laser products will not be changed. All pure detector products (without IRED component): No eye safety classification needed Product affected: all packaged OS IRED products 14 OS-IN-2017-032 15.08.2017
9) New Disclaimer Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in lifesupport devices** or systems with the express written approval of OSRAM OS. *) A critical component is a component used in a lifesupport device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. OSRAM OS components are not developed, constructed or tested for the application as safety relevant component or for the application in medical devices. In case Buyer or Customer supplied by Buyer considers using OSRAM OS components in product safety devices/applications or medical devices/applications, Buyer and/or Customer has to inform the local sales partner of OSRAM OS immediately and OSRAM OS and Buyer and /or Customer will analyze and coordinate the customerspecific request between OSRAM OS and Buyer and/or Customer. Reason: Previously the disclaimer was related to life-support devices or systems only. The focus now should be generalized to safety relevant components or for the application in medical devices. Product affected: All OS products. 15 OS-IN-2017-032 15.08.2017