Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Safety Light Curtain C 4000

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Electrical connection

Electrical connection

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Light curtain bar pairs

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Amplifier for fiber optics. Dimensioned drawing

SPACESCAN SERIES SS 02

Electrical connection

Electrical connection

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

SU17 Series Fiber Optic Sensors

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Operating Instructions

Standard signal metering in wall-mounting case

Operating instructions Through-beam sensor. OJ51xx / / 2004

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

Electrical connection

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Operating instructions Electronic preset counter Type series 717

Assembly. Front view. LEDs. Parametrization interface. Power Bus

REGO Start&Go USER MANUAL

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Absolute Encoders Multiturn

Next Generation 4800 LUX. RT STROBE pocket LED. The ultra high-performance, hand-held stroboscope. Superfast. Superbright. Superlight. Supertight.

Technical data. General specifications. Indicators/operating means

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Standard RS232 RS ma

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Lt DELTA USA, Inc

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

KNX Dimmer RGBW - User Manual

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectrics Through-beam Type PA18C.T..., DC

MICROMASTER Encoder Module

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

STX Stairs lighting controller.

Safety Light Curtains

WF next: Fork sensors for a wide range of applications

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS AND SERIOUS CALLBACKS.

V 180 Series Photoelectric Switches

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

TC3005(LED/ELED/LASER) User's Manual

Actuators IC 20, IC 40

Inductive sensor NI3-EG08K-Y1-H1341

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Amplifier for fiber optics. Dimensioned drawing

02/11/2015

Gamma instabus. Technical product information

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

1440/2880 HP RGB+WW+CW

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Transmitter optics with 9x white light LED (optics cover made of glass)

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

DLP200M 2 Relay Module for Heating and Cooling Plants

LCD Thermometer / Clock S No. 1253

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

TC3301. User's Manual

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Safety Light Curtain Orion1 Extended

SERIES 400 SERIES 620

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Transcription:

Light Curtain Type LA Status: 2011-04-27 Subject to change without notice. No responsibility is taken for the correctness of this information. Your suggestions for corrections or improvements are welcome! Features No separate control unit is needed. The device can be directly connected to 24 V DC. 2 short-circuit-proof PNP-outputs, NPNoutputs optionally Functions and parameters configurable via PC interface. Easy-Run: full configuration settings from factory. Automatic range setting during calibration cycle Diagonal beams analysis for enhanced monitoring resolution. DUOmetric AG Weberstr. 8 86836 Lagerlechfeld /Graben Tel: +49-8232-95979-0 Fax: +49-8232-95979-29 www.duometric.de E-Mail: support@duometric.de

Table of content Features... 1 Table of content... 2 The bars and mechanical design... 3 Functions... 4 Signal output... 4 Switching Threshold... 4 Usage... 4 Output assignment... 4 Output assignment normal... 4 Output assignment inverted... 4 Output assignment inverted without warning... 5 OutDelay... 5 Beam variations... 6 Recommendations:... 6 Contamination alarm... 6 Recommendations:... 6 TopBlankable... 7 Beam Blanking... 7 Recommendations:... 7 Syncbeam Synchronisation beam... 7 Recommendations:... 7 Areas... 7 Recommendations:... 7 NOFDARK... 8 Configuration values... 9 Recommendation... 9 Calibration Sequence... 10 Recommendations:... 10 Flashing codes during the calibration cycle... 10 LED Indicators / Error Diagnosis... 11 Receiver bar... 11 Transmitter bar... 11 Interfaces / Outputs... 12 M8 connector... 12 Installation / Initial Operation... 12 Conformity... 13 Technical Data... 13 PC-Interface... 14 Ordering Key and Example... 15 Key:... 15 Example... 15 Accessories... 16 Page LA 2of LA 16

The bars and mechanical design A wide choice of beam spacing and attachment options (mechanical) is available. Please refer to separate light curtain bar information sheet: Information sheet: light curtain bars Page LA 3 of LA 16

Functions Signal output You can configure the light curtain to be light or dark switching via the output function parameter. light dark Free beams active inactive interrupted beams inactive active Switching Threshold During the calibration sequence the signal intensity of each (parallel) beam is measured and permanently stored. By multiplying with the relative switching threshold (percentage of the relative threshold) the absolute threshold for each beam is determined. In order to have the system react to small signal reductions a higher switching threshold has to be adjusted. The threshold shall not exceed 179 (equivalent to ~70%). Usage o Automatic threshold detection => RelThreshold = 0 o Detection of transparent objects => high threshold o Reduced beam deflection influence => high threshold Output assignment The light curtain has two outputs (wires black and yellow). The Output functions can be set via the parameter Output assignment. Output assignment normal Output Wire Function Description Out 1 Yellow Signal out light or dark switching Out 2 Black Warning out Active during disruption Exception > Start second range 0 Out 1 Yellow Area 1 light or dark switching Out 2 Black Area 2 light or dark switching Output assignment inverted Functions like normal but with switched outputs Output Wire Function Description Out 1 Yellow Warning out Active during disruption Out 2 Black Signal out light or dark switching Exception > Start second range 0 Page LA 4of LA 16

Out 1 Yellow Area 2 light or dark switching Out 2 Black Area 1 light or dark switching Technical information Output assignment inverted without warning Out 1 is without function. Out 2 is used as Signal out on black wire Output Wire Function Description Out 1 Yellow - No function Out 2 Black Signal out light or dark switching Exception > Start second range 0 Out 1 Yellow - No function Out 2 Black Area 1 light or dark switching Output assignment antivalent Out 1 is as Signal out on yellow wire Out 2 is active when Out 1 is inactive. OutDelay This configuration value delays the status change of switching outputs by the set value in milliseconds (ms). Maximum delay value is 255 ms. Page LA 5 of LA 16

Beam variations Parameter Diagonal = 0 Diagonal = 1 Diagonal = 4 Description Multiple beam diagonal beams off diagonal beams on crossings Number of n 2n-1 5n-6 beams Max beam number (n) 128 64 26 Drawing Recommendations: o After changing this parameter run a calibration cycle. o The cycle time increases with the number of beams. o A total of 128 logical beams is supported. Contamination alarm If the beam brightness remains under a certain threshold (weak signal threshold) for a specific duration (weak signal delay), the light curtain signals a simple error. Remedy: Clean the beam output. Attention: do not damage the front foil. Do not use caustic cleaning agents. Align the bars and recalibrate. Recommendations: Set the weak signal threshold parameter to 0 in order to switch off the contamination alarm. Page LA 6of LA 16

TopBlankable Technical information When turning on the device interrupted beams and the bar ends can be blanked out permanently.. TopBlankable defines, how many consecutive beams are blanked out. This function was specifically implemented for elevator systems. Beam Blanking Permanently interrupted beams can be blanked automatically. Which identical beams can be blanked is adjusted with the Max.autoblanked parameter. Max.autoblanked Automatic Blanking 0 None 1 each 2. identical beam 2 each 3. identical beam...... Defective beams are not considered in the analysis. The parameter Maxdefect defines the number of ignored beams. A serious error is signaled should the number of defective beams exceed the value of Maxdefect. Blanked out beams are not added to Maxdefect. Recommendations: o Use the section Beam Configuration on the right side of the DUO-Konfapplication window in order to manually blank out beams. Select there which receiver element shall be blanked out. o The Syncbeam must always stay active! Syncbeam Synchronisation beam The Syncbeam parameter defines whether the first (near the connectivity point) or the last beam is used for the optical synchronisation. Recommendations: o Transmitter and receiver have to be set to the same value. o The Syncbeam cannot be blanked. o Interruption of the Syncbeam is signal on both sections. Areas Parameter Start second area separates the light curtain into two areas. The status of the areas is signaled at outputs OUT 1 and OUT 2. Recommendations: o Switching ranges for Diagonal 0 (=> diagonal beams on) overlap. o Interruption of the Syncbeam is signaled in both areas. o Areas can be configured to be light or dark switching. Page LA 7 of LA 16

NOFDARK Defines the threshold after which number of interrupted beams the outputs are switched (separately for both areas). Example: NofDark1 = 5 => Output of areas 1 switches after 5 interrupted beams in section 1. Special: Start second area = '1' Both NofDark-values relate to the entire monitoring range. After reaching the corresponding number id interrupts the corresponding output is switched. Page LA 8of LA 16

Configuration values Standard value First Beam 1 value always equals 1 Description Last Beam 1 xx value is system dependent Output function Light switching Dark switching Output assignment normal inverted inverted without warning antivalent Diagonal 0 = diagonal beams off 1 = diagonal beams on Relative Threshold Maxdefect 84 1 2...4 = multiple beam crossings 84 equals 33% (256 equals 100%) 0 = automatic theshold adjustment activ. Max. number of allowed defective beams Delay for Autoblanking Time in seconds until a beam interruption can be 60 blanked Max. Autoblanked Number of consecutive identical beams available 0 for blanking Start for second area Beam number defining the start oft he second 0 section. Only recommended for Diagonal = 0! Syncbeam first = synchronisation via first beam last = synchronisation via last beam NofDark1 Minimum number of interrupted beams defining 1 an interruption. (Area 1) NofDark2 Minimum number of interrupted beams defining 1 an interruption. (Area 2) OutDelay Duration in ms between output state changes. 0 (range: 0 255 ms) TopBlankable number (1,2 or 3) of beams that can be blanked 0 consecutively during power-up. Weak signal threshold Threshold for contamination warning. 147 equals 57% (Wert x 256) Weak signal delay Time in seconds after which a contamination is 60 signaled AutoCalDelay Recommendation o Configuration value Syncbeam must be identical for Transmitter and Reciever for the light curtain to work properly. 1 Only the value of physically present beams can be adjusted. A incorrect value can result in improper functionality. Page LA 9 of LA 16

Calibration Sequence 1. Place yellow wire on +24 V DC during activation. => self-calibration (other flashing signals as those in normal mode). 2. Both LED of the receiver bar illuminate steady => self-calibration is completed without an error. 3. Remove yellow wire as long as LA is still switched on => saves sensitivity data. Example for implementation with standard connectivity (plus switching): 1. Insert a bridge between connection points of yellow wire and brown wire (plus). 2. Ensure that the entire monitoring range is uninterrupted. 3. Turn on supply voltages. 4. Remove bridge. Recommendations: The calibration is important for proper functionality of the light curtain. Rerun the calibration after each change on the light curtain. For an error-free calibration the monitoring range must be free of obstacles and both LEDs on the receiver must light up. Flashing codes during the calibration cycle One LED flashes LEDs flash in-phase LEDs flash out-phase Defective beams Differences too big or not yet calibrated. Verify alignment of bars as well as monitoring range. Error during Selftest Page LA 10of LA 16

LED Indicators / Error Diagnosis When the light curtain detects a failure, the warning output is enabled and the LED displays one of the following error codes. As soon as the failure is resolved, the output becomes inactive again. Receiver bar LED1 LED2 Operating mode Monitoring area off off off unknown on on operational free on off operational beam interrupted flashing on simple error free flashing off simple error beam interrupted Double Off Configuration error unknown flashing flashing flashing flashing (in phase) flashing (out of phase) fatal error A fatal error B unknown unknown Simple error: Light curtain continues to run with constriction, for example, beam blanked or contamination alarm. Fatal error: Light curtain no longer operational. Transmitter bar LED off on flashing Operating mode off operational error Page LA 11 of LA 16

Interfaces / Outputs M8 connector View towards connector pins Installation / Initial Operation Pay attention to the installation rules (see mounting instructions for light curtain bar pairs). Avoid optical sensors from mutually affecting each other, even through reflection, because this can lead to malfunction. Maximal 1.5 secounds after power up the light curtain is operating. Insulate unused wires. Disconnect the connections during insulation measurements. Execute a calibration cycle. Page LA 12of LA 16

Conformity The light curtain version LA is compliant and meets all the requirements of the following standards: EN 61000-6-3:2001. EN 61000-6-1:2001. The light curtains are not certified safety lights curtains compliant with EN 61496. They are not safety components in the context of EU Machine Guideline 89/392/EEC with 93/44/EMW addition, Appendix 4. Therefore, they must not be used so as not to endanger individuals. Technical Data Light curtain housing Connection Transmitter Receiver Operating voltage Power consumption Outputs Operating temperature -10 C to 45 C Range 2 Reduced range Response time Maximum number of beams Naturally anodised aluminium, plastic front panel, dark red (Do not use any cleaning agents containing solvents!) Securely attached lines 4 m long, precut with wire end ferrules 2-core round cable, about 4,9 mm (PVC) 4-core round cable, about 4,9 mm (PVC) 24 V DC (-15%..+20%) with max. ripple 5%, protected against polarity reversal, use polarised earthed power supply! approx. 8 W (total) Short-circuit-proof semiconductor outputs PNP (or NPN) switched current max. 200 ma ~ 0.7... 4 m (calibration necessary) default setting: 4m ~ 0.2 1 m (calibration necessary) 1 ms cycle time per beam plus base time (~4 ms) 128 logical beams 2 With standard profile. Range with other profile types see techn. Information light grid bar pairs. Page LA 13 of LA 16

PC-Interface The PC Interface connects to the serial port of a PC. Use the Software DUO-Konf for configuration of a light curtain pair. Plus switching light curtain Transmitter brown blue green Receiver brown blue black yellow Minus switching light curtain Receiver brown blue black yellow Page LA 14of LA 16

Ordering Key and Example Key: Light curtain bar pair Consisting of receiver and transmitter bar Type Beam Number / Mechanical Options Beam Separation LA Choose from beam seperation between 5mm and 112 mm. Choose from 4 shapes and 8 mounting options Color Cable length Connectivity option Front cover. For details regarding the specific ordering codes refer to detailed light curtain bar document. Example LA16/112-2000A Light curtain bar pair with integrated controler unit (24 Vdc, PNP) 16 beams Beam spacing of approx. 112 mm Bar length 2000 mm, bar cross-section 12x24 mm, Aluminium naturally anodized 4 bolts on top, cone on the bottom Protection class IP54 Parameterisation: standard*) LA24/12,5-510I Light curtain bar pair with integrated controler unit (24 Vdc, PNP) 24 beams Beam spacing of approx. 12,5 mm Bar length 510 mm, bar cross-section 12x24 mm, Aluminium naturally anodized 2 M4x10 threaded stud bolts spaced 400 mm apart Protection class IP54 Parameterisation: dark diagonal beams *) Default values can be found in the configuration table. Please mention different parameterisations in your purchase order. Page LA 15 of LA 16

Accessories LCPower/2 FP-110-00001 LCPower/2-SR FP-110-00002 Programminginterface LA FP-20-13538 Power Supply(24Vdc) for types LC/LA/LT - 230/110 Vac - plastic housing - Protection class IP65 - Relais Power Supply(24Vdc) for types LC/LA/LT - 2xRelaisoutput - connections via PG 9 - internal connection via terminal block - plastic housing - buzzer Programming interface for plus- and minus switching systems Including connection wires DUO_Konf-Software for Download: http://www.duometric.com/dokus/la/ Page LA 16of LA 16