8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Similar documents
Advanced Test Equipment Rentals ATEC (2832)

8650A SERIES UNIVERSAL POWER METERS

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

Microwave Counter, Power Meter and DVM in One Portable Package

Agilent 5345A Universal Counter, 500 MHz

E4416A EPM-P Series Single Channel Power Meter

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Agilent 8560 E-Series Spectrum Analyzers

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

R-1580A Microwave Downconverter. Product Brochure

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Advanced Test Equipment Rentals ATEC (2832)

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

GFT Channel Digital Delay Generator

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet


Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

Full-featured CW Microwave Counters for Field, Factory or Lab

Agilent Technologies 54522A

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

R&S ZVA110 Vector Network Analyzer Specifications

GFT Channel Slave Generator

R-1550A Tempest Wide Range Receiver

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

UFX-EbNo Series Precision Generators

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Keysight N1913A and N1914A

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

MICROWAVE MEASURING INSTRUMENTS

Keysight Technologies E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Agilent 8757D Scalar Network Analyzer

JD725A Cable and Antenna Analyzer - Dual Port

Keysight N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Data Pattern Generator DG2020A Data Sheet

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

Keysight Technologies E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Spectrum Master. Compact Handheld Spectrum Analyzer. Technical Data Sheet

OPTICAL POWER METER WITH SMART DETECTOR HEAD

PM Series Microwave Power Calibration System

PM Series Microwave Power Calibration System

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

DVO700 P FIBRE OPTIC TRANSMITTER

CBF500 High resolution Streak camera

SATCOM FIBER OPTIC PRODUCTS

Data Pattern Generator

Datasheet SHF A

ScopeMeter 190 Series Specifications

R3267/3273 Spectrum Analyzers

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

SYNTHESIZED COMMUNICATION CONVERTERS

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

R&S ZNBT Vector Network Analyzer Specifications

Synthesized Clock Generator

High-Value 100 Series (Outdoor)

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Boonton 4540 Remote Operation Modes

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Assembly Level Service Guide

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Calibrating attenuators using the 9640A RF Reference

2 MHz Lock-In Amplifier

Spectrum Analyzers. 2399A 9 khz to 3 GHz Spectrum Analyzer.

R&S ZND Vector Network Analyzer Specifications

Portable Performance for Debug and Validation

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

PULSE & DELAY GENERATOR. Output Amplitude HIGH SPEED DIGITIZER. BW / max. Sample Rate STREAK CAMERA

R&S FSMR Measuring Receiver Specifications

1/3 RACK-MOUNTED BLOCK CONVERTERS

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

DA E: Series of Narrowband or Wideband Distribution Amplifiers

HP 70950B OPTICAL SPECTRUM ANALYZER

MULTIBAND 1/3 RACK-MOUNTED

R&S EDS300 DME/Pulse Analyzer Specifications

Multiple Band Outdoor Block Up- and Downconverters

SMS3000X Series Spectrum Analyzer

Microwave/Counter/Analyzer with Integrated Power Meter MCA3000 Series Datasheet

R&S FPC1000 Spectrum Analyzer Specifications

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Multi Application Test System

USB Smart Power Sensor

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Keysight Technologies N1090A, N1092A/B/C/D/E and N1094A/B DCA-M Optical and Electrical Sampling Oscilloscopes

Technical Description

FRQM-2 Frequency Counter & RF Multimeter

Signal Stability Analyser

N1000A DCA-X. Wide Bandwidth Oscilloscope Mainframe and Modules. Find us at Page 1

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

Microwave/Counter/Analyzer & Integrated Power Meter

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Page 1 of 5 8500A The Giga-tronics 8500A Series Peak Power Meters THE ACCURACY STANDARD channel capability. For tests on pulse mod- SERIES PEAK POWER METERS combine CW power measurement with the ability to make precise peak power measurements at any point on a pulsed waveform. This dual, built-in capability lets you measure and analyze pulsed waveforms with a single instrument. VITAL STATISTICS 8500A Series meters let you view a pulsed waveform, along with critical parameters, on a built-in display. A reference cursor pinpoints the precise measurement location on the waveform with 100 ps resolution. Precise sequential sampling lets you measure the same point on each pulse at over 70 measurements At the heart of an 8500A Series meter is a built-in power sweep calibrator with NIST traceable accuracy. The calibration system uses the inherent linearity and stability of an ovenized thermistor to accurately calibrate the high-speed diode sensors from 0 to 50 C, ambient. This built-in capability lets you make absolute power measurements with accuracy generally found only in thermistor power meters. And automatic self-calibration take less than a minute. ONE OR TWO CHANNELS Choose the Model 8501A meter for single-channel operation, or the Model 8502A meter for two- ulators and pulsed TWTs, the 8502A can measure a CW signal on one channel and a pulsed signal on the other. And the power reading from each sensor is independently corrected, automatically. BUILT-IN FREQUENCY RESPONSE CALIBRATION Correcting for sensor frequency response is easy and automatic. Each sensor contains an EEPROM programmed with the frequency calibration factors measured at the factory, or in your cal lab. When you key in the frequency at which power is being measured, the meter automatically applies the per second. correct cal factor

Giga-tronics 8500A Series Peak Power Meters Page 2 of 5 from the sensor EEPROM. Not only is this an easy way to handle cal factors, but it also avoids the chance of errors from reading a table or graph. It also saves time on GPIB systems, because you don t have to manually enter a new set of cal factors when changing sensors. Sensor diodes and PROMS can be replaced in the field. Use the Giga-tronics PROM programmer to download new cal factor data into the replacement PROM. AUTOMATIC SELF EXAMINATION AND CALIBRATION 8500A Series meters automatically execute a self-test routine at turn-on that performs eleven different checks on critical internal circuitry. When turned on, an 8500A Series meter also checks the serial number of the attached sensor and, if necessary, requests selection of the automatic calibration routine. MENU DRIVEN OPERATION 8500A Series meters are extremely easy to use. Interactive prompts and softkey-operated menus step you quickly and easily through triggering setups and measurements. Rise time, pulse width and fall time can be displayed automatically. ANALYZE PULSE PROFILES Analyze pulse profiles and read peak power at any point on the pulse using the reference level cursor. And make precise timing measurements, such as rise time and pulse width, using up to four measurement points per channel. GBIP OPERATION GPIB capability allows computer control of the instrument. Many internal high-level functions, such as rise time and pulse width, are available directly over the bus, freeing you to perform other tasks. Power readings can typically be made every 10ms, using the Fast Data mode. An optional internal MATE interface is also available. HIGH-SPEED DIODE SENSORS Giga-tronics uses high-speed diode sensors, rather than slower thermal sensors, to achieve higher sampling rates. Interchangeable sensors cover the frequency range from 30 MHz to 40 GHz. Fast rise time sensors are available to measure single shot or repetitive pulses as narrow as 15 ns. And the same sensors measure CW signals over a wide -40 to +20 dbm dynamic range.

Giga-tronics 8500A Series Peak Power Meters Sensor Selection Guide and Specifications Page 3 of 5 Sensor Selection Guide Power Range Maximum Maximum Model Frequency Range Peak CW Power VSMR RF Connector High Speed Sensors (<15 ns Rise Time, Typically 10 ns) 16936A 750 MHz to 18.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 Type N(m) 16937A 750 MHz to 18.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 APC-7 17266A 750 MHz to 26.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 Type K(m) 17071A 750 MHz to 40.0 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 Type K(m) 26.5 to 40.0 GHz 1.92 Low Frequency Sensors (<750 ns Rise Time, Typically 500 ns) 16934A 30 MHz to 18.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 Type N(m) 16935A 30 MHz to 18.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 APC-7 17267A 30 MHz to 26.5 GHz 20 to +20 dbm 40 to +20 dbm +23 dbm Below 2.0 GHz 1.12 Type K(m) METER Frequency Range: 30 MHz to 40 GHz depending on sensors (see sensors specifications) Power Range: Pulse: -20 to +20 dbm CW: -40 to +20 dbm (see sensor specifications) ACCURACY The uncertainty of microwave power measurements depends on several factors, the most imporant being the effective mismatch of both the power sensor and the RF source. Excluding mismatch effects, the measurement uncertainties of the instrument are: Calibration Power Uncertainty (at 0 dbm): ± 1.5% Linearity after Automatic Calibration: ± 3% (at stable temperature) Typical Temperature Coefficient of Linearity at Ambient ± 5 C, CW and Peak; typical: >-10 dbm: negligible, 0 to 50 C <-10 dbm; ± 0.5%/ C, 15 to 50 C; ± 1.0%/ C, 0 to 15 C (Instrument indicates if ± 5 C calibration range is exceeded.) Uncertainty due to Zeroing and Noise: CW (Avg.=500): <± 10 nw, 15 to 50 C; <± 20 nw, 0 to 15 C Peak (Avg.=100): <± 3.5 µw, 15 to 50 C; <± 5.0 µw, 0 to 15 C Single Pulse (typ.): <± 15 µw, 15 to 50 C; <± 30 µw, 0 to 15 C Measurement Uncertainty (Using Root of the Sum of the Squares) Assume Frequency = 6 GHz and Source Return Loss 16 db Total RSS Uncertainty Uncertainty Calibration Factor Uncertainty at 6 GHz 3.40% 1.82% Calibrator at 1 GHz 1.50% 0.80% Calibrator/Sensor Mismatch at 1 GHz 0.60% 0.60% Linearity (If not near 1 mw) 3.00% 3.00% Noise ±3.5 µw Sensor/Source Mismatch 3.20% 3.20% Total Measurement Uncertainty= 11.7% ±3.5 µw RSS Value = 4.85% ±3.5 µw 1 1 Total Measurement Uncertainty = Total Calibration Factor Uncertainty + Total Calibrator Uncertainty + Total Calibrator/Sensor Mismatch Uncertainty + Total Linearity Uncertainty + Total Sensor/Source Mismatch Uncertainty + Total Noise Uncertainty Time Base Range: 1.2 ns/div to 20 ms/div (12 ns to 200 ms time window, using either the Data Entry Keyboard or the Control Knob.) Maximum Resolution: 0.1 ns Accuracy: 0.01% of time window, ± 1 ns

Giga-tronics 8500A Series Peak Power Meters Specifications Page 4 of 5 Triggering Modes: Internal: -20 to + 16 dbm External (BNC): TTL Levels, Maximum PRF 1 MHz Trigger Delay Range: 0 to 200 ms, using either the Data Entry Keyboard or the Control Knob. Resolution: 0.1 ns Accuracy: 0.01% of delay, ± 1 ns Minimum Pulse Width: 20 ns, 15 ns rise time sensors Markers: Up to 4 markers per channel plus a Reference Power Level cursor. Markers can be positioned at any point on the pulse waveform. Typcially they would be positioned to make rise time and pulse width measurements. The markers and cursor can be positioned either at user selected delays or automatically at specified percentage of amplitude for pulse parameter measurements. Graph Display Mode: Plots the outline of the detected pulse on the front panel display, and provides readout of amplitude and timing information. Fast Measurement Mode: Available under GPIB control to provide fast data acquisition and output. For an average number = 1, typically between 70 and 120 measurements per second are made. Via the rear panel analog output, swept frequency response tests can be made using a network analyzer. Power Sensor Calibration Factor Uncertainties Power Sensors 16934A 16934A 16935A 17266A 16935A 17266A 16936A 17267A 16936A 17267A 16937A 17071A 16937A 17071A Frequency Sum of Uncertainties (%) 2 Probable Uncertainties (%) 3 30.0 MHz to 1.0 GHz 1.39 3.06 1.25 1.64 1.0 to 2.0 GHz 2.34 3.51 1.44 1.73 2.0 to 4.0 GHz 2.93 4.42 1.60 1.93 4.0 to 8.0 GHz 3.42 4.94 1.82 2.08 8.0 to 12.4 GHz 4.31 6.04 2.30 2.55 12.4 to 18.0 GHz 4.91 6.86 2.53 2.83 18.0 to 26.5 GHz 9.27 3.63 26.5 to 40.0 GHz 15.19 6.06 2I Includes uncertainty of reference standard and transfer uncertainty. CALIBRATOR Frequency: 1 GHz ± 5% Power Uncertainty at 1 mw: ± 1.5% Return Loss at 1 mw: >25 db Self Calibration Time: <1 minute Connector: Type N(f) GENERAL Stored Setups: Saves settings at power down and ten additional stored setups in non-volatile memory. Self-Test: Performed automatically at turn-on and optionally at anytime. A diagnostic code indicates the cause and location of any errors. Reset Control (Rear Panel): Returns instrument to present default condition. Design and Construction: To the intent of MIL-T-28800C, Type III, Class 5, Style E or F, Color R. Power Requirements: 100, 120, 220 or 240 VAC ± 10%, 48 to 480 Hz. Power Consumption: Approximately 100 VA Temperature: Operating: 0 to 50 C (32 to 122 F) Non-operating: -40 to +65 C (-40 to 149 F) Humidity (Operating w/o precipitation): 95% ±5% to 30 C; 75% ±5% to 40 C; 45% ±5% to 50 C Physical Characteristics: Size: 13.3 cm H x 42.6 cm W x 35.6 cm D (5.25 in x 16.75 in x 14 in) Weight: Model 8501A, 12 kg (26 lbs); Model 8502A, 13 kg (28 lbs) AUXILIARY OUTPUTS/INPUTS (BNC) Monitor: Provides a real time profile of the detected RF envelope. Rise time is typically 20 ns, output impedance is nominally 50 Ω. Voltage output is typically 4 mv to +2 V depending on power level. Trigger Input: TTL RF Blanking: TTL open collector low during zeroing. Used to control power source. Directly traceable to NIST. 3 Square root of the sum of the individual uncertainties squared (RSS).

Giga-tronics 8500A Series Peak Power Meters Specifications Page 5 of 5 Analog Output: Provides a voltage proportional to detected power. Scale factor is 100 mv/db, ±0.5%, offset is <±10 mv. Voltage Proportional to Frequency (V/GHz): Allows direct entry of frequency from RF power sources equipped with V prop F output. GPIB INTERFACE In accordance with IEEE STD 488-1978 GPIB Indicators: REM, TLK, LSN, SRQ, LLO Remote Operation: Complete setup and measurement capabilities accessible via GPIB. Reporting of errors, malfunctions, operational status and self-test diagnostics available through serial poll capability. Direct Plot Output: Outputs hardcopy pulse profile, including time, date and part identification, to a GPIB plotter. GPIB Address: Selectable from front panel. GPIB Interface Functions: SHI, AHI, T6, L4, SRI, RLI, PPO, DCI, DTI, TEO, LEO ORDERING INFORMATION Peak Power Meters 8501A Single Channel Peak Power Meter 8502A Dual Channel Peak Power Meter Power Sensors 16934A 30 MHz to 18.5 GHz, Type N 16935A 30 MHz to 18.5 GHz, APC-7 16936A 750 MHz to 18.5 GHz, High Speed, Type N 16937A 750 MHz to 18.5 GHz, High Speed, APC-7 17266A 750 MHz to 26.5 GHz, High Speed Sensor, Type K 17267A 30 MHz to 26.5 GHz, Type K 17071A 750 MHz to 40.0 GHz, High Speed Sensor, Type K 17071/S5428 500 MHz to 40.0 GHz, High Speed, Type K Options 01 Rack Mount 03 Rear Panel Sensor and Calibrator Connectors (Replaces Front Panel Connectors) 04 Internal MATE Interface 2002 Giga-tronics Incorporated GT-071-B Accessories and Maintenance Tools 16956-001 Extra Sensor Cable Assembly, 5 ft. 16956-002 Extra Sensor Calbe Assembly, 10 ft. 14052 IEEE-488 (GPIB) Cable, 2 Meter 16976 Sensor PROM Programmer 17075 Extender Board, Single Connector 17076 Extender Board, Dual Connector 20790 Extra 8500A Series Manual 19206 8500A Series Calibration Kit: Consists of 17075, 17076, 16976 & 20790 Giga-tronics Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800 726 4442 or 925 328 4650 Telefax: 925 328 4700 Web Site: www.gigatronics.com