NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Similar documents
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications

FOX THEATRE ST. LOUIS

Technical Specifications

Technical Specifications

The Breen Center for the Performing Arts Saint Ignatius High School

Marjorie S. Deane Little Theater

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

Lighting Information

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Technical Services and Specification

Performing Arts Theatre

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Patriots Theater at the War Memorial Technical Data

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

FIVE FLAGS THEATER SERVICES STATEMENT

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

NORTH CHARLESTON PERFORMING ARTS

Technical Information

TECHNICAL PACKAGE.

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Dale F. Halton Theater Technical Specifications

Sandusky State Theatre Technical Specifications

SAINT ANSELM COLLEGE DANA CENTER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

DEREHAM MEMORIAL HALL

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

NORTH CHARLESTON PERFORMING ARTS

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Concert Hall Technical Specifications

Technical Specifications. Taylor Little Theater

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Directions. Driving directions and other UCSD maps

SHUBERT THEATER 247 College Street, New Haven, CT

Technical Information

Technical Specifications and Inventory Spring 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Theatre Technical Specifications

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Baker Hall Technical Information Package

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Arcadia Performing Arts Center Technical Specifications and Information

Theater Technical Information

Clayton Center for the Arts Ronald and Lynda Nutt Theater Technical Specifications December 2014

Technical Specifications

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Concert Hall Technical Specifications

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Quick-Advance Fact Sheet

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Main Stage Technical Specs - Hall #2

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

PRODUCTION INFORMATION

Venue and Production Information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

NORTH CHARLESTON PERFORMING ARTS

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Technical Specifications

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

THEATRE PROJECTS. Parts of a Theatre Building

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Facility Information

Stephen B. Humphrey Theater

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

Bartlesville Community Center

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Ferst Center for the Arts Technical Specifications (Revised May 2016)

TECHNICAL INFORMATION

Downtown Arts Center Tech Packet. General Information

Paramount Theatre Production Recap

TECHNICAL SPECIFICATIONS MARSHALL E. RINKER, SR. PLAYHOUSE

THEATRE TECH MANUAL. Location and Mailing Address: Irving Arts Center 3333 North MacArthur Suite 300 Irving, Texas 75062

Dinkelspiel Auditorium - Technical Specifications

Center Theater Technical Information 9/1/12

Facility Technical Information

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Technical Facilities Specifications Erling B. and Dorothy E. Hanson Auditorium West Delaware High School

New Theatre Royal Lincoln Technical Information

Latrobe Performing Arts Centre

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

VENUE TECHNICAL REQUIREMENTS

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

JEANNE B. McCOY COMMUNITY CENTER FOR THE ARTS TECHNICAL SPECIFICATIONS

TECHNICAL INFORMATION & SERVICES

Transcription:

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7

LOAD IN The Victoria Theater stage is directly accessible via loading dock doors off SL. Distance from dock doors to stage is approximately 50. There is room at the dock for 1 tractor-trailer. Stage Loading Doors are 11'-8" W x 18'-6" H STAGING STAGE SPECIFICATIONS STAGE FLOOR Sprung flooring system, maple tongue and groove surface on ¼ neoprene pads. There are no traps in the floor. The use of stage fasteners, lags, screws, or nails, etc. must be discussed. The use of rosin and other dance treatment is restricted to areas covered by a linoleum or other dance floor coverings. Any damage to the floor must be repaired at the expense of the Presenter. PROSCENIUM OPENING 40'-0 W x 24'-0 H STAGE DIMENSIONS Width: Wing Space SR 17'-0 Wing Space SL 20'-0 Depth: plaster line to US wall 39'-4" apron depth, DS from plaster line 4'-0 depth of orchestra pit at center 7'-0 Height: of the stage 3-2 FLY GALLERIES Height from stage floor SR and SL: 30'-0 ORCHESTRA PIT The primary position is audience level with seats row AA 101-108 & BB 101-108 (total 16 seats). The pit measures 7'-0 deep at center, 40'-0 wide, with an additional 11'-0 of depth extending under the apron. The orchestra pit platforms can be manually set at three levels: stage height, audience level and orchestra pit level. DISCUSS POSITIONS WITH PRODUCTION MANAGER. PORTABLE PLATFORMS There are 32 units of 4-0 x 8-0 Wenger System risers with skirts (subject to availability). Leg heights are in increments of 8 up to 40. Casters are available. There are 9 units of 2 H X 6 W, 3 steps Wenger Choral Risers with railings (subject to availability). A fourth step add-on is available for choral risers. EMPTIES STORAGE Empties may be left in the loading dock. In addition, part of the basement under the Prudential Hall stage may be available for storage. This must be discussed with the Production Manager. Page 2 of 11

STAGING (CONT D) RIGGING SPECIFICATIONS GRID 59'-6" height from stage floor. Made of 3" channel with wells at CL, and 11'-0, 22'-0 SR and SL. HOUSE CURTAIN FLY RAIL Blue/green, manual, guillotine only, center split, operates from DSR Stage Right, operator at stage level BATTENS 39 manual single purchase counterweight sets on varied centers with 48'-0 long battens of 1.5" pipe and truss battens where noted. Each line set is rated for 1,100 pounds capacity. TRIMS Pipe trims In: 3'-7" Out: 56'-9" Maximum travel 53'-2" LIGHT LADDERS EXTRA WEIGHT There are 4 light ladders on motorized tracks, 28-10 SR and 29-8 SL of center, adjustable tracking 3 0 to 33-0 from plaster line. All are 21 h x 20 with 7 rungs. 25,000 pounds SOFT GOODS & RIGGING INVENTORY 1 House curtain 46-0 w x 28-0 h with a center split 1 Downstage Black Out Drop 45-0 w x 28-0 h, black velour without a split 1 Midstage Black Out Drop 45-0 w x 28-0 h, black velour without a split 1 Upstage Black Out Drop 48-0 w x 28-0 h, black velour with a center split 1 Border 48-0 w x 20-0 h, black velour, no fullness, pipe pocket in bottom 5 Borders 48-0 w x 12-0 h, black velour, no fullness, 12 Legs 12-0 w x 28-0 h, black velour, no fullness 1 Black scrim, sharkstooth 48-0 w x 35-0 h, pipe pocket in bottom 1 Natural muslin cyc 48-0 w x 32-0 h, pipe pocket in bottom 4 Tabs 8-0 w x 28-0 h, black velour, no fullness, pipe pocket in bottom 6 Tabs 6-0 w x 28-0 h, black velour, no fullness, pipe pocket in bottom 1 White Chiffon Drop 44 w x 20 h 1 Green Austrian Drop 50 w x 30 h 1 Traveler Track 48-0 LINE SCHEDULE - (SUBJECT TO CHANGE) See attached document. The rep position for the legs is 18-0 right and left of center. The rep position for the border is 20-0 to the bottom of the border. Page 3 of 11

LIGHTING CONTACT & POLICY All lighting and circuitry plots need to be discussed with the Head Electrician at (973) 297-5856.. PRODUCTION LIGHTING CONSOLE ETC ION with current software With Wireless Remote Focus Unit DIMMERS HOUSE LIGHTS CURTAIN WARMERS 312-2.4Kw Dimmers The house is wired in dimmer per circuit configuration House lights can be controlled from three positions: the lighting booth, the follow spot booth, and backstage wall panel located downstage right. There are five presets; full, half, concert, lecture, and out. Additionally, there is a local setting that can be set from either the lighting booth or the backstage panel allowing individual settings for 8 channels of houselights. The fade time between any two settings is approximately six seconds and is not adjustable. Curtain warmers can be controlled from three positions: the lighting booth, the followspot booth, and from the downstage right equipment rack. There are four presets: full, half, preset, and out. Additionally, there is a local setting that can be set from either the lighting booth or the backstage panel allowing individual settings for two channels. In rep, each of these two channels control a pair of Par 64 s on the balcony rail. The fade time between any two settings is approximately six seconds and is not adjustable. Page 4 of 11

LIGHTING (CONT D) DIMMER POSITIONS & NUMBERS FRONT OF HOUSE (Dimmers are numbered SL to SR) Far catwalk Dimmers 1-24 Near catwalk Dimmers 25-38 High Box Booms Dimmers SR 57-65, SL 48-56 Low Box Booms Dimmers SR 75-83, SL 66-74 Balcony rail Dimmers 39-47 ONSTAGE LOCATIONS (Dimmers are numbered SL to SR, DS to US) 1st Elec. Dimmers 90-121 2nd Elec. Dimmers 131-139, 140-149 3rd Elec. Dimmers 150-159, 169-177 4th Elec. Dimmers 178-186, 187-195 5th Elec. Dimmers 241-249 Fly Galleries Dimmers SR 256-261, SL 265-273 DS Wall Dimmers SR 284-288, SL 280 283 (mirrored on US wall) US Wall Dimmers SR 253-255, 277-279, SL 250-252, 274 276 Grid Dimmers 289-294, 295-300, 301-306, 307-312 1 Ladder Stage Left Dimmers #122 - #130 2 Ladder Stage Left Dimmers #160 - #168 3 Ladder Stage Left Dimmers #196 - #204 4 Ladder Stage Left Dimmers #232 #240 1 Ladder Stage Right Dimmers #122 - #130 2 Ladder Stage Right Dimmers #160 - #168 3 Ladder Stage Right Dimmers #196 - #204 4 Ladder Stage Right Dimmers #232 #240 Ladder dimmer boxes can be used as drop boxes if not already in use. HOUSE & WORK LIGHTS House lights, aisle lights and work lights are on a separate dimming system. The House Lights are controlled SR, in the Light Booth and in the Followspot Booth. INVENTORY & ACCESSORIES (subject to change) LIGHTING INVENTORY 24 Source4 750 19º units (FOH) 80 Source4 26º units 66 Source4 36º units 12 Source4 50º units 40 Altman 8 Fresnels, 1Kw 24 Altman 6 Fresnels, 750w 52 Source4 PAR with all lenses 12 L & E 3-circuit (12 lamp) PAR 56 strips, 300W mfl 16 L & E 3-circuit (30 lamp) MR-16 strips, 75W/12V 10 Altman T3 X-Rays 3Circuits(12 lamp) 500W fcl 2 1K Xenon Trouper Spotlights 30 Par 64 1K (upon availability) ACCESSORIES High hats, barndoors, 4 drop in irises, cables and other lighting hardware for house units are available. Please call the Head Electrician at (973) 297-5856 with inventory enquiries. Page 5 of 11

LIGHTING (CONT D) CONTROL & POWER CONTROL POSITIONS Control booth orchestra level, shared with sound, 62' from plaster line Spotlight booth 62'-0 out and 34'-0 up from plaster line, contains 2 Xenon Trouper Followspots CUE LIGHTS ON STAGE POWER The control stations, which are located DSL & DSR, control cue-light circuits. The outputs are DSL, DSR, and USR. DSL and DSR - 100A, 3 phase, 4 wire, 120/208 Vac disconnect Pit SL - 60A, 3 phase, 4 wire, 120/208 Vac disconnect There is no company power and no transfer panel. There is separate power for sound. CONTACT & POLICY AUDIO Please contact the Head of Audio (973-297-5878) with specific questions. SYSTEM & INVENTORY See Audio One Sheet DISTRIBUTION & OTHER FEATURES MULTI All 48 lines of the multi feed the Sound Booth or House Mix Position or Broadcast (Victoria Theater loading dock) Position with wire only (no splitter). COMMUNICATIONS HEARING ASSISTANCE VARIABLE ACOUSTIC CURTAINS POWER A four channel Clear-Com system is installed throughout the theater with base station capability at SL, Control Booth, House Mix or production table. 1 HME 4 station wireless system with 4 headsets, patched to the Clear-Com system. A dressing room monitor and paging system is installed, paging from SL. AUDIO (CONT D) Sennheiser SI-1013 infrared system with 20 headsets, 5 hearing aid plug in adapters, 5 hearing aid loop adapters. Manually operated velour acoustic curtains are located throughout the theater. These convert the theater from hard, live mode (ideal for recitals) to soft mode. DSL - isolated ground, 100A, 3 phase, 4 wire, 120/208 Vac disconnect. This is separate power from lighting. VIDEO MONITORING VIDEO & STAGE MANAGEMENT A Color and Black and white low light camera is located on the balcony rail focused on the stage. Monitors are located at the stage manager s station DSL and DSR. A limited number of other monitors and cameras are available. PROJECTION There are three projection screens, subject to availability SCREENS 1 15 X 20 framed screen with front and rear projection surfaces, rigged to fly 1 12 X 16 framed screen with front and rear projection surfaces, rigged to fly with dress kit and optional legs 1 7.5 X 10 framed screen with front and rear projection surfaces, not rigged to fly Page 6 of 11

with dress kit and legs STAGE MANAGEMENT There are positions SL and SR and in the booth for a stage manager. SL and SR position POSITIONS are equipped with both color and infra-red cameras, paging station, wired Clear-Com station, cue light, and house light controls. SUPPORT SPACES **SMOKING AND PETS ARE PROHIBITED THROUGHOUT THE FACILITY** HOSPITALITY AND ARTIST ACCOMMODATIONS PERFORMERS Located just off Stage Left LOUNGE DRESSING ROOMS All dressing rooms are located stage left. Each is equipped with audio monitoring and paging systems, and all have individual bathrooms with showers. STAGE LEVEL 2 Principal Dressing Rooms (mirrors for 4) SECOND FLOOR 4 Chorus Dressing Rooms (2 with mirrors for 8, 2 with mirrors for 10). All are accessible by stairs. OFFICE The Visiting Company Production Office is located stage level, just off SL. The phone number is (973) 297-5867. Page 7 of 11