Operating Instructions

Similar documents
INSTRUCTION MANUAL V Barometric Pressure Sensor. May Copyright 2007 Campbell Scientific (Canada)Corp.

TELEDYNE HASTINGS INSTRUMENTS

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

SUPPLEMENTARY INFORMATION

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

LAUREL ELECTRONICS, INC.

Level Measurement silometer FMC 420, FMC 423

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

T-Series "SMART" Sanitary Pressure Transmitter

Signet 2250 Hydrostatic Level Sensor

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

Digital differential Pressure switch Model DPS Instruction manual

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Process Transmitter RMA 422

SCALE & WEIGHT DISPLAYS

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

T775U Series 2000 Electronic Stand-Alone Controller

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Digital differential pressure controller Model DPD Instruction manual

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Modular Lube Lubrication Systems System Controls

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

J R Sky, Inc. tel: fax:

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

T775U Series 2000 Electronic Stand-Alone Controller

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Micro-Machined Silicon Transducers

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Model IQ4-PC User Manual Revision Date:

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

263 Series LED Bargraph Indicator and Controllers

The measurements are stored in non-volatile memory, which retains data even when the power down.

Standard signal metering in wall-mounting case

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Series 937B. Features & Benefits

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

Vacuum measurement and control units

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

CERTIFICATE of EU TYPE-EXAMINATION

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

FIELD MOUNTED RATE TOTALISER MODEL 202D

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DMP 331i / DMP 333i LMP 331 i

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Revision 1.2d

4.9 BEAM BLANKING AND PULSING OPTIONS

AH-PMP-1DA & AH-1DA Operator's Manual

Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

CNV-ALT. Introduction. 1 Features. Serial altitude to parallel Gillham code converter for mode C transponders. Operating Manual English 1.

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

D Issue G. Instruction Manual. Wide Range Gauge

Pen and Multichannel Recorder: Digital Display

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

RST INSTRUMENTS LTD.

3 Cleaning. 4 Technical data

Electronic converter for level transmitters MT03L Instructions manual

T10 Float Level Switch

GC61 Digital Pressure Gauge. Operation Manual

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

MKS. Series 937B. Opera. RevC

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

800 Displaying Series Flowmeter

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Pressure transmitter COMPACT IO-Link,

2291 Guided Wave Radar Level Transmitter

Sensopress LCD Special English

Pressure transmitter For applications in hazardous areas Model IS-3

Transcription:

Operating Instructions Vacuum Transmitters for Diaphragm & Pirani Sensors 24 VDC Power With Pirani Sensors.01 to 100 mtorr.01 to 100 X 10-3 mbar.001 to 13.3 Pa 1 to 2000 mtorr.001 to 2 mbar 0.1 to 200 Pa.01 to 20 Torr.01 to 26 mbar 1 to 2660 Pa With Diaphragm Sensors 1 to 1500 Torr 1 to 2000 mbar 0.1 to 200.0 kpa Atmos. to 30 in. Hg

Vacuum Transmitters for Diaphragm & Pirani Sensors 24 VDC Power.01 to 100 mtorr.01 to 100 X 10-3 mbar.001 to 13.3 Pa 1 to 2000 mtorr.001 to 2 mbar 0.1 to 200 Pa.01 to 20 Torr.01 to 26 mbar 1 to 2660 Pa 1 to 1500 Torr 1 to 2000 mbar 0.1 to 200.0 kpa Atmos. to 30 in. Hg Contents Introduction...............................................1 Specifications.............................................1 Pirani Gauges, Analog Output Settings & Circuit Board Maps.01 to 100 mtorr /.01 to 100 X 10-3 mbar /.001 to 13.3 Pa...2 & 3 1 to 2000 mtorr /.001 to 2 mbar / 0.1 to 200 Pa............4 & 5.01 to 20 Torr /.01 to 26 mbar / 1 to 2660 Pa...............6 & 7 Diaphragm Gauges, Analog Output Settings & Circuit Board Maps 1 to 1500 Torr / 1 to 2000 mbar / 0.1 to 200.0 kpa...........8 & 9 Atmos. to 30 in. Hg.................................10 & 11 Calibration of Transmitter...................................12 Gauge Tube Wiring.......................................14 i

Vacuum Transmitters for Diaphragm & Pirani Sensors 24 VDC Power.01 to 100 mtorr.01 to 100 X 10-3 mbar.001 to 13.3 Pa 1 to 2000 mtorr.001 to 2 mbar 0.1 to 200 Pa.01 to 20 Torr.01 to 26 mbar 1 to 2660 Pa 1 to 1500 Torr 1 to 2000 mbar 0.1 to 200.0 kpa Atmos. to 30 in. Hg These vacuum transmitters are available with Pirani or Diaphragm sensors in ranges from 10-5 Torr to 1500 Torr. Instruments are also available calibrated in microns, in. Hg, PSI, mbar, and Pascal. The basic transmitter has a non-linear 0 to 5 VDC output and an optional digital display is available. Transmitters with the digital display have a linear 0 to 2 VDC output. We recommend that the gauge tube cable with the connector wired to one end be puchased with the transmitter. Cables up to 500 feet (150 m) can be used if wire gauge is #22 or larger. Specifications Absolute & Differential Vacuum Gauges/Transmitters Power: Gauges operate from 12 to 35 VDC power, 150 ma. for all ranges except.01 to 20 Torr which requires 300 ma. Response time: With VRC Pirani; 0.3 sec time constant. With VRC Diaphragm tubes; less than 400 milliseconds. Accuracy: Pirani Gauges better than 5% of value or ±3 mt. whichever is larger. Diaphragm Gauges 1% of reading or ± 2 Torr whichever is larger. Relay: SPDT contacts rated for 5A @ 115 VAC, non-inductive. Remote Sensor Absolute or Differential 1

Pirani Gauges.01 to 100 mtorr.01 to 100 X 10-3 mbar.001 to 13.3 Pa Linear analog output for 100 mt transmitters with digital display 0 to 1 volts, 1 mv = 1 mtorr Non-linear analog output for 100 mt transmitters without digital display and linearizer. OUTPUT SIGNAL VOLTS 0.000 0.013 0.026 0.062 0.121 0.180 0.239 0.567 1.065 1.504 1.890 2.225 2.516 2.770 2.992 3.354 3.639 4.054 4.765 5.000 in mtorr 0.00 0.05 0.10 0.25 0.50 0.75 1.00 2.50 5.00 7.50 10.00 12.50 15.00 17.50 20.00 25.00 30.00 40.00 75.00 100.0 in mbar.00000.00006.00013.00033.00066.00100.00133 00333.00606.01000.01333.01666.02000.02332.02666.03332.04000.05332 0.09997 0.13330 in Pascal.000.006.013.033.066.100.133.333.666 1.000 1.333 1.666 2.000 2.332 2.666 3.332 4.000 5.332 9.997 13.333 2

Pirani Gauges.01 to 100 mtorr.01 to 100 X 10-3 mbar.001 to 13.3 Pa Gauge with Display Gauge with No Display 3

Pirani Gauges 1 to 2000 mtorr.001 to 2 mbar 0.1 to 200 Pa Linear analog output for 2000 mt transmitters with digital display 0 to 2 volts, 1 mv =1 mtorr Non-linear analog output for 2000 mt transmitters without digital display and linearizer. OUTPUT SIGNAL VOLTS 0.000 0.052 0.105 0.207 0.499 0.726 0.937 1.210 1.319 1.493 1.655 2.450 2.662 3.024 3.686 3.969 4.127 4.402 4.674 4.856 5.000 in mtorr 0.0 5.0 10.0 20.0 50.0 75.0 100.0 135.0 150.0 175.0 200.0 350.0 400.0 500.0 750.0 900.0 1000.0 1250.0 1500.0 1750.0 2000.0 in mbar 4 0.0 6 13 27 67 100 133 180 200 233 267 467 533 666 1000 1200 1,333 1,666 2,000 2,333 2,666 in Pascal 0.0 0.7 1.3 2.7 6.6 10.0 13.3 19.8 20.0 23.3 26.6 46.6 53.2 66.5 99.8 119.7 133.0 166.3 200.0 232.7 266.0

Pirani Gauges 1 to 2000 mtorr.001 to 2 mbar 0.1 to 200 Pa Gauge with Display 0 to 5 VDC Gauge with No Display 5

Pirani Gauges.01 to 20 Torr.01 to 26 mbar 1 to 2660 Pa Linear analog output for 20 Torr transmitters with digital display 0 to 2 volts, 1 mv =10 mtorr Non-linear analog output for 20 Torr transmitters without digital display and linearizer. OUTPUT SIGNAL VOLTS 0.000 0.011 0.072 0.149 0.371 0.703 0.989 1.239 1.997 2.530 2.930 3.243 3.800 3.816 3.899 4.057 4.195 4.482 4.695 4.864 5.000 in Torr 0.000 0.010 0.050 0.100 0.250 0.500 0.750 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 12.500 15.000 17.500 20.000 in mbar 0.000 0.013 0.067 0.133 0.333 0.667 1.000 1.333 2.670 4.000 5.330 6.670 8.000 9.330 10.670 12.000 13.330 16.660 20.000 23.330 26.660 in Pascal 0 1.33 6.65 13.3 33.25 66.5 99.75 133 266 399 532 665 798 931 1064 1197 1333 1663 1995 2328 2660 6

Pirani Gauges.01 to 20 Torr.01 to 26 mbar 1 to 2660 Pa Gauge with Display Gauge with No Display 7

Diaphragm Gauges 1 to 1500 Torr 1 to 2000 mbar 0.1 to 200.0 kpa 1 to 1500 Torr Linear analog output for 1500 Torr transmitters with or without digital display is 0 to 1.500 VDC, 1 mv =1 Torr 1 to 2000 mbar Linear analog output for 2000 mbar transmitters with or without digital display is 0 to 2.000 VDC, 1 mv =1 mbar 0.1 to 200.0 kpa Linear analog output for 200.0 kpa transmitters with or without digital display is 0 to 2.000 VDC, 1 mv = 0.1 kpa 8

Diaphragm Gauges 1 to 1500 Torr 1 to 2000 mbar 0.1 to 200.0 kpa Gauge with Display Gauge with No Display 9

Diaphragm Gauges Atmos. to 30 in. Hg Linear analog output for 30 in. Hg transmitters with digital display is 0 to +300 mv, 1 mv = 0.1 in. Hg Linear analog output for 30 in. Hg transmitters without digital display and linearizer. OUTPUT SIGNAL VOLTS 0.000 0.050 0.100 0.200 0.210 0.220 0.230 in inches Hg Atmosphere 5.0 10.0 20.0 21.0 22.0 23.0 OUTPUT SIGNAL VOLTS 0.240 0.250 0.260 0.270 0.280 0.290 0.300 in inches Hg 24.0 25.0 26.0 27.0 28.0 29.0 30.0 Gauge Pressure vs. Absolute Pressure Please note that this is a Gauge pressure instrument. The other instruments in this manual are built to measure pressure in Absolute units such as Torr, Microns, and mbar. Gauge pressure means that atmospheric pressure is used as the reference for zero and 29.92 in. Hg designates high vacuum. Gauge pressure measurement can be useful in certain applications such as determining if a vacuum chamber is actually at atmospheric pressure so that the door can be opened safely. But, because the zero of Gauge measurements changes with atmospheric pressure the entire scale also changes. For example, if you are reading 28.00 inches Hg and the next day your instrument reads 28.39 inches Hg it may be that your pump is working better or it may be that a storm moved into your area and atmospheric pressure dropped. Changes in altitude also affect the readings of Gauge pressure instruments. For example, there is a difference of 5 inches Hg (127 Torr) between sea level and Denver, Colorado. 10

Diaphragm Gauge Atmos. to 30 in. Hg 0 to + 300 mv Gauge with Display 0 to + 300 mv Gauge with No Display 11

Calibration of Transmitter Two methods for calibrating these transmitters are described below. Calibration using the Reference Gauge Calibrator This method requires a reference gauge calibrator, and for transmitters without the optional digital display, you will also need a digital voltmenter with an accuracy of + 0.1 mv or better and a current calibration certificate. Purchase the calibrator from the vacuum gauge manufacturer or your supplier. And be sure that the calibrator matches the range of your instrument. Connect the calibrator in place of the gauge tube and follow the instructions on the front panel of the calibrator. Calibration using a Manometer and Vacuum System This method requires a high vacuum system and a certified precision calibration "standard" such as a capacitance manometer. If your transmitter does not have a digital display a high quality digital voltmeter will be required. Be sure the instrument has been turned on with a gauge tube installed for at least one hour before calibrating. 12

100 mtorr and 2000 mtorr Pirani (See pg. 3 for 100 mt circuit board map & pg. 5 for 2000 mt circuit board map) 1. Short pins (#5 green wire and #8 white wire) on the terminal strip together. The tube does not have to be disconnected. Locate the Offset pot and adjust so the digital display reads 000. Remove the wire short from between pins 5 and 8. 2. Pump the tube to hard vacuum (1 hour for 100 mt and 30 minutes for 2000 mtorr. Locate the Zero pot and adjust so the digital display reads 000. Note: Hard vacuum means 10-6 Torr or lower for 100 mt; 10-5 Torr or lower for 2000 mt instruments. 3. Raise the pressure in the system to a known upscale point. 100 mt = 40.00 mt upscale point; 2000 mt = 900 mt upscale point. Locate the Span pot and adjust so the digital display reads the proper upscale number. 4. Repeat steps 1, 2, and 3 until no further adjustments are necessary. 20 Torr Pirani Transmitter (See pg. 7 for circuit board map) 1. Short pins (#6 blue wire and #7 brown wire) on the terminal strip together. The tube does not have to be disconnected. Locate the Offset pot and adjust so the digital display reads 000. Remove the wire short from between pins 6 and 7. 2. Pump the tube to hard vacuum for 30 minutes. Locate the Zero pot and adjust so the digital display reads 0.00. Note: Hard vacuum means 10-4 Torr or lower for 20 Torr instruments. 3. Raise the pressure in the system to a known upscale point. 20 T = 9 Torr upscale point. Locate the Span pot and adjust so the digital display reads 9.10 4. Repeat steps 1, 2, and 3 until no further adjustments are necessary. 1500 Torr Diaphragm Transmitter (See pg. 9 for circuit board map) There are only 2 calibration adjustments that are normally necessary to restandardize the instrument. One is an offset adjustment. The second is a span adjustment to set up scale tracking at some known pressure. Plug in the power cord of the instrument for at least 30 minutes before calibrating. 1. Pump the transducer to hard vacuum ( The term hard vacuum refers to any pressure lower than.1 Torr (100 mt). This is a relative zero below which the transducer no longer changes output. It need not be known as long as you are sure it is this low.) Adjust the OFFSET pot until the meter reads 0. 2. Vent the transducer to atmosphere. Call the nearest airport weather station and obtain the immediate barometric pressure. Ask for station pressure not altimeter setting. Multiply the figure you are given for barometric pressure by 25.4 to convert to mmhg (Torr) from inches Hg. Then, 13

adjust the Span pot until the display reads that pressure. For example, if you are in Pittsburgh and you are at 636 ft. altitude on a standard day the following is true: at sea level the Std. Barometer is 29.92 in Hg = 760 Torr (29.92 X 25.4 = 759.968 Torr). This is the altimeter setting for an aircraft, so that at landing the plane s altimeter reads 636 ft. (At sea level the altimeter reads 000.) Multiply the station pressure by 25.4 to convert inches Hg. to Torr and adjust the span to read the calculated number which in the above example is 743 Torr. To obtain this information, look in the phone book under US Government, Transportation Dept., and call the number for Pilot One Call Briefing. Ask for the Station Pressure. Tell them your application is for industrial calibration purposes. Atmosphere to 30 in. Hg Diaphragm Transmitter (See pg. 11 for circuit board map) Zero adjustment is made by exposing the transducer to atmospheric pressure and setting the Offset pot to read 000 on the meter. Pump the transducer to a vacuum that is at least 2 mmhg (Torr) absolute or lower. It need not be known as long as it is less than the 2 mm Hg. Obtain the correct barometric pressure and adjust the pot marked Span to read the barometric pressure. To obtain the correct barometric pressure call the FAA Pilot one call briefing line at your local airport. Ask for the Station Pressure, not the Altimeter setting. Gauge Tube Wiring The gauge tube can be checked with an ohmmeter between pins 1 and 5 to verify that the sensor is good. Generally, the reading is less than 2.5 ohms if good; 900 ohms if the sensor is broken. The actual readings for each type of tube should be as follows: SENSOR PINS 1 TO 5 BLACK AND GREEN WIRE APPROXIMATE RESISTANCE 100 mt 2.4 Ohms 2000 mt 2.1 Ohms 20 Torr 1.3 Ohms 14

Printed 7/26/03 Vacuum Research Corporation 2419 Smallman Street Pittsburgh, PA 15222 USA (800) 426-9340 (412) 261-7630 FAX: (412) 261-7220 e-mail: vrc@vacuumresearchcorp.com