AEV ITB201 - dual telephone hibryd AEV ITB 2O1. Dual Telephone Hybrid

Similar documents
BSM Evolution USB - Compact ON AIR console. BSM Evolution USB. AEV On Air compact broadcast console

AEQ BRAVO Broadcast Mixing Console

clipping; yellow LED lights when limiting action occurs. Input Section Features

AEQ TH-03 Digital Hybrid of 1 (TH-03.1) or 2 lines (TH-03.2) with Frequency Extender

Distribution Unit. User Guide

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

AMU2-2MHD+ Audio monitoring Unit

ENGLISH Antenna Distributor

AEQ BRAVO Broadcast Mixing Console

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

PROFESSIONAL 2 CHANNEL SOLID-STATE MIC / LINE PREAMPLIFIER USER S MANUAL

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Noise Detector ND-1 Operating Manual

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

USER MANUAL GOLDMUND PH3 Phono Preamplifier

INSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

SP205+ DUAL 1x5 VIDEO & AUDIO DISTRIBUTION AMPLIFIER

ASP-FIBRS1 User Manual

Technical Specifications

In-Line or 75 Ohm In-Line

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

Integre4. Audiophile integrated amplifier. v1.2

MX-206 Stereo Microphone Mixer. Operating Manual

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

DH400. Digital Phone Hybrid. The most advanced Digital Hybrid with DSP echo canceller and VQR technology.

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

12 Channel Media Splitter MS12 Mk2 User manual

MANUAL ENGLISH Core Club Ordercode: D2314

USER MANUAL Goldmund PH3.8 Phono Preamplifier

Summit Audio Model TLA-50 Tube Leveling Amplifier

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

USB-TG124A Tracking Generator User Manual

508 Phono Preamplifier. Boulder Amplifiers, Inc. 255 S. Taylor Ave. Louisville, CO (303) /1/2018 Rev. 1.

Oxygen ORDERCODE D2150

AVMU2-BHD+/3G Audio monitoring Unit

32 Channel CPCI Board User Manual

HeadAmp 4 Pro. User s Manual. Project Series. Five Channel Headphone Amp with Listen and Talkback

VK-P10SE WARRANTY REGISTRATION FORM

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

5.1 + Stereo Monitor Controller

Natural-sounding telephone audio... Hybrids

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last.

VGA & Audio over CAT5 Distribution Series

NS-3 RF Noise Source Operation Manual

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Kramer Electronics, Ltd.

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

DCX-24 ORDERCODE D2020


Phono Amplifier brinkmann «EDISON» Manual.

INSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

Operating Instructions

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

AMU1-BHD+ Audio monitoring Unit

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

BISON 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

Utility Amplifier GA6A Model

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

innkeeper LTD Digital Hybrid User Guide JK Audio

ZIG-POEPRO-70A. HDBaseT HDMI Extender

EXT-HBT70-SET_2016V1.2

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

ZIG-POC-100. HDBaseT HDMI Extender

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

USB Phono Plus. Project Series USER S MANUAL. Audiophile Computer Interface

BP2-MM MM Phono Preamplifier Owner s Manual

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

16-Channel Headstage Omnetics IFU

Reference 150 LINEAR

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

Power Source The equipment should be connected to a power supply only of the type described in this manual or as marked on the equipment.

Kramer Electronics, Ltd. USER MANUAL. Model: 482xl. Bi-directional Audio Transcoder

DISTRIBUTION AMPLIFIER

By CHANNEL VISION. Flush Mount Amplifier A0350

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

THERMIONIC CULTURE. TheEarlybird 2.2. valve microphone pre-amplifier OPERATING MANUAL

Transcription:

AEV ITB 2O1 Dual Telephone Hybrid 1

Guarantee The equipment is warranted for a period of 2 years from the date of invoice (exworks). The warranty does not cover faults provoked by carelessness, natural causes and parts subject to wear. In addition, the cost of labour and shipment is not covered. The warranty will be voided if the equipment is mishandled. AEV Broadcast via della Tecnica,33 40050 ARGELATO (BO) ITALY Web site : www.aev.eu - email: info@aev.eu Feedback AEV welcomes your comments on our products. Your suggestions may be extremely useful to develop new equipment and manuals and this will be of benefit to you too! Let us have your comments on our products and we will be pleased to read them. Send your information by e-mail to the following address::info@aev.eu Technical Support If you require technical support, contact AEV SERVICE giving a clear and concise account of your specific problem. Quote the serial number of your equipment by referring to the AEV nameplate attached to the equipment itself as this is the most important piece of information to be provided. Factory Service If problems arise while the equipment is being installed, consult this manual and check that the installation is being carried out properly. If the problems still cannot be solved, call the AEV SERVICE Department for further information. If the problem is a minor one we can a telephone call will probably suffice. If, on the other hand, the equipment is to be shipped to AEV for service or repairs, the AEV SERVICE Dept. will accept it only if the RMA return authorisation number has been provided. This number must be included in the shipping documents. We also recommend providing a detailed description of the fault which has occurred, the type of service needed and (if required) the name of the employee at the AEV SERVICE Dept. you have spoken to. No repairs will be made if the cost of shipment is charged to AEV. In this case, we will not accept the delivery. 2

Shipping Instruction When shipping the equipment to AEV, use the original package in order to be certain that it will be fully protected during handling. If you need the original package, call us for a new one. If you ship the equipment in a different packing container, take care to provide a double package by interposing padding material between the two containers in order to fully protect the equipment during shipment. The package should be marked "FRAGILE" in red. IMPORTANT: Carefully read this paragraph as it contains important instructions concerning operator safety and directions regarding the installation, operation and maintenance of the equipment. Failure to observe the safety instructions and information given in this manual constitutes an infringement of the safety rules and design specifications provided for this piece of equipment. Futurcom. declines all responsibility if any one of the safety rules given herein is not observed. Futurcom declines all responsibility if the end-user resells the product. Keep this manual with the utmost care and close at hand so that it can be consulted whenever needed After unpacking the equipment, check it for condition. Avoid banging the equipment. The packing material (plastic bags, polystyrene, nails, etc.) must never be left within the reach of the children, as these items are potential sources of danger. Do not use the equipment in places where the temperature is not within the recommended range, as specified by the manufacturer. Before connecting the equipment, make sure the nameplate specifications correspond to the mains electricity supply (the nameplate is located on the equipment enclosure). Do not remove the sticker from the equipment as it contains important specifications and the relevant serial number. To join the equipment to the mains supply, use the power cord purchased with the equipment. The equipment must be used only for the purpose it was designed for. Abuse or misuse of the equipment is extremely dangerous for people, pets and property. The manufacturer declines all responsibility for damage and injury resulting from improper use and mishandling. Certain basic safety rules must be observed when using electrical equipment, in particular: - Never touch the equipment with wet and/or damp hands or other parts of the body. - Keep the equipment away from drops of water or sprinkling systems. - Never use the equipment near high heat sources or explosive material. - Do not introduce any extraneous matter into the equipment. - Do not allow children or untrained people to use the equipment. 3

Contenents Guarrantee...1 Precaution...1 Technical support...1 Factory Service.....1 Shipping Instruction...2 Safety precautions......3 Contenents....4 Telephone Hybrid...5 General Features...5 Intallation...6 The front panel...6 The rear panel...6 Connection to mixer and lines...7 Line Hook...7 Adjusting level......7 Line compensation...7 Technical data...7 Audio levels...7 Hybrid circuit...7 General Data...8 Connection...8 Remote...8 4

Telephone hybrid A telephone hybrid is a system that provide the connection between a telephone line and an audio equipment. Actually, this is not a simple connection since the telephone line characteristics require special techniques to ensure good audio quality and high immunity to interference. The frequency response of a normal telephone line is set between 100 Hz and 3-4 KHz in order to guarantee an acceptable reproduction of the human voice. A telephone hybrid must have a much wider bandwidth, in order to adapt itself to the quality of any line and to avoid further limitations to the system. Unfortunately telephone lines suffer often of intense disturbances, noise, crackling, fading etc. Furthermore they are often sources or conductors of static charge and overvoltage, that are able to destroy circuits which have been imprudently connected to them. In addiction, the resistive and capacitive behaviour of lines is not uniform, and thus barely repeatable, and clearly the transmitted audio quality will vary with time. It is therefore necessary to take particular care in the design of line-audio interfaces in order to avoid significant degradation of the bandwidth or rejection of induced interference. The interface must also ensure complete electrical isolation between theline section and that connecting to the audio equipment. Another problem arises during a telephone connection between a remote correspondent and an interviewer or DJ; the DJ s voice will be transmitted down the telephone line and, since the same line is used for transmission and reception, will be received again with delay with respect to the original. It will be re-amplified and looped back resulting in whistles and Larsen effects. Antilocal circuits are fitted to remedy this by identifying those audio components which tend to enter into the loop and eliminating only the part which re-enters. This is particularly necessary for Meetings General Features AEV ITB-201 MKII is a studio telephone hybrid. It is designed in a 19", 1 unit rack mount. ITB-201 MKII allows the connection of 2 phone lines individually commutable during transmission. By means of an extra telephone, to be plugged into 2 special connectors, you may call or receive on both lines. The calls are visualized by leds and announced by a ringer. ITB-201 MKII was specially designed to solve all interfacing problems between lines and any Mixer having no telephone module. It allows to call or receive private communications or to pass them over to the antenna without having to use additional headsets or microphones. It is easy to install and requires no special instruments. ITB-201 MKII has an available output to record phone conversation both privately and in antenna. Installation AEV ITB-201 MKII telephone hybrid has been designed and manufactured to conform to urrent safety standards. The unit should only be installed by competent personnel and in compliance with operator safety requirements and the environmental specification. Great care should be taken in making earth and ground connections to the unit and associated equipment. As for any electronic apparatus, adequate ventilation for cooling must be ensured in order to guarantee operating temperatures within the limits defined in the Technical Specifications section. This is particularly important in the case of rack mounting or installation in confined or poorly ventilated locations. It is advisable to leave a space between each unit and adjacent units 5

AEV ITB201 - dual telephone hibryd (above and below) even if mounted in a ventilated rack. If well connected to the rack s ground and earth connections, the unit will be immune to interference including RF, as long as the high frequency units have been correctly connected. The AEV ITB-201 MKII is anyhow fitted with RF filters on its inputs in order to eliminate annoying interference. Gas discharge tubes are fitted to the telephone lines to guarantee immunity from static charges or over-voltage. General Description Front Panel 1 2 1 ) HOOK LIN 1 2 ) LINE SELECTION 3 ) HOOK LIN 2 4 ) BUZZER OFF/ON 5 ) LIN ADJ 6 ) STAND BY 7 ) RECEIVE 8 ) MIX 9 ) SEND 10 ) POWER 3 4 5 6 7 8 9 10 Hooks line 1 (equivalent to pick up the handset) Selects the line to be put on air Hooks line 2 (equivalent to pick up the handset) Buzzer enable Button Antilocal effect adjustment trimmer Stand By phone line Button Adjusts the phone line receiving level Adjusts the phone line transmission level Rx and / or Tx Adjusts the phone line transmission level Power Led Rear Panel 1 2 3 4 5 6 7 8 9 AC POWER SEND REC RECEIVE TEL LINE 2 TEL SET 2 TEL LINE 1 TEL SET 1 REMOTE Line power socket Audio input Phone call recording output Audio output Service telephone connection (connector RJ45) Telephone line connection (connector RJ45) Service telephone connection (connector RJ45) Telephone line connection (connector RJ45) Remote function connector (DB9) www.aev.eu info@aev.eu 6

Connections to mixer and lines The connection of the AEV ITB-201 MKII to 2- wire telephone lines is made by inserting the telephone cable into the corresponding socket on the ITB-201 MKII using a standard telephone line connector. Other telephonic equipment may be connected by inserting a standard connector in the ppropriate ITB-201 MKII socket. This additional equipment is useful for making calls and checking the line. Connection is optional. The mixer output should be connected to the hybrid s TX TEL input, whilst the line return RX TEL can be connected to an input connected to the CUE of the same mixer. WARNING: TAKE GREAT CARE IN CONNECTING LOOP-BACKS TO THE MIXER. FAILURE TO DO SO CAN GENERATE HUM, ECHOES AND TUBE EFFECTS. Line Hook To hook a line it is necessary to lift the ( HOOK switch on the front panel). Adjusting Levels Once the line has been hooked, adjust the TX and RX level by injecting a 1 KHz test signal, or a standard signal, and calibrate the levels for a near zero reading on the mixer. Line Compensation Once the telephone line is busy, it is possible to carry out an optimization through the Line Compensation potentiometer (A.L.E.). The fine adjustment is obtained by injecting a TX signal and receiving a minimum RX signal. Hanging-Up Lowering the HOOK switch on the front panel releases the line. Technical Data AUDIO LEVELS Input level (SEND 1/2) ± 12 dbm Input impedance >10 KΩ Electronically Balanced Connector XLR female Output level (RECEIVE 1/2) 0 dbm Output impedance 100 Ω Electronically Balanced (max load 600 Ω) Hybrid Circuit Input/output balanced and floating. Impedance 600 Ω RX Level - 20 0 dbm TX Level - 8 dbm Hybrid null - 40 db Full Band (on urban telephon line) Frequency response 230 3400 Hz Distortion 0.8 % 7

GENERAL DATA Power supply Dimension Weight 87 a 254 V 50/60 Hz 10 VA 19" Rackmount 1 Unity 2.0 Kg Attentino: All cables should not be more than 3 meters length. Connection SEND: 1-GROUND 2-INPHASE 3-RETURN RECEIVE: 1-GROUND 2-INPHASE 3-RETURN 2 WIRE: 2-N.C. 3-TEL. SET / TEL. LINE 4-TEL. SET / TEL. LINE 5-N.C. REMOTE CONNECTOR 2 - Hook 1 (active low TTL input : internal pull-up 4K7) 3 1 / 2 SEL (active low TTL input : internal pull-up 4K7) 4 - Hook 2 (active low TTL input : internal pull-up 4K7) 9 - Rem 1 (active low TTL input : internal pull-up 4K7) 5 - + 5 Volt (50 ma max) 1 - GND 6 - GND 7 - LED 1 (50 ma max) 8 - LED 2 (50 ma max) 8