High Performance Outdoor Test Translators

Similar documents
Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Multiple Band Outdoor Block Up- and Downconverters

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

1/3 RACK-MOUNTED BLOCK CONVERTERS

MULTIBAND 1/3 RACK-MOUNTED

High-Value 100 Series (Outdoor)

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

SYNTHESIZED COMMUNICATION CONVERTERS

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Instruction Manual Model Block Up/Downconverter

SATCOM FIBER OPTIC PRODUCTS

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Satellite Up- and Downconverter Indoor / Outdoor

Instruction Manual Model

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

Indoor Dual Converter

Synthesized Block Up- and Downconverter Indoor / Outdoor

Instruction Manual Model

L-Band Block Upconverter

Instruction Manual Model Ka-Band Block Downconverter

Synthesized Block Up- and Downconverter

Inmarsat Downconverter Narrowband Downconverter

Satellite Up- and Downconverter

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Satellite Up- and Downconverter

L-Band Block Up- and Downconverter Indoor / Outdoor

Instruction Manual Model # Block Upconverter

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Product Catalogue January 2018

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

Instruction Manual Model BlockUpconverter

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Modular Block Converter Systems

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

DA E: Series of Narrowband or Wideband Distribution Amplifiers

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

X-Band Redundant LNB Systems

Analog & Digital RF-Solutions

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Ku-Band Redundant LNB Systems

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

C-Band Redundant LNB Systems

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

THE ART OF ENGINEERING

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

R-1580A Microwave Downconverter. Product Brochure

R3267/3273 Spectrum Analyzers

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Wideband LNB: 2.4 GHz

DVO700 P FIBRE OPTIC TRANSMITTER

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

Typical applications:

Instruction Manual Model Block Downconverter

16W Ku-band Matchbox BUC

Instruction Manual Model UHF, L-Band, Up/Downconverter

ThinkRF D GHz RF Downconverter

The Art of Engineering

Instruction Manual Model Block Upconverter

MP7200. RF Recorder / Player.

Advanced Test Equipment Rentals ATEC (2832)

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

HDO701 FIBRE OPTIC TRANSMITTER

Instruction Manual Model Downconverter

RF Semiconductor Test AXRF RF Port Upgrade Kits

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ACION 8000 Series. A8KFR1 1RU Forward Receiver

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Up/Downconverter

Instruction Manual Model Upconverter

Datasheet SHF A

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

2 MHz Lock-In Amplifier

MODEL Band Channels Up/Down IF In/Out RF In/Out Step Size Remote M&C Price

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Noise Detector ND-1 Operating Manual

10MHz Source/Inserter

Ku-band 2W (3W typ.) Transmitter Model No. NJT5037 Type 1 (N-type Female Input Connector) Model No. NJT5037F Type 2 (F-type Female Input Connector)

Transcription:

Input Output LO Frequency Frequency Frequency Model (GHz) (GHz) (GHz) Number RF Transmit-Band to RF Receive-Band 5.85 6.425 3.625 4.2 2.225 DN-WS-6.1/3.9 5.85 6.65 3.4 4.2 2.45 DN-WS-6.25/3.8 6.725 7.025 4.5 4.8 2.225 DN-WS-6.8/4.6 7.9 8.4 7.25 7.75 0.65 DN-WS-8.15/7.5 7.9 8.4 7.175 7.675 0.725 DN-WS-8.15/7.4 12.75 13.25 10.7 11.2 2.05 DN-WS-13/11.2 13.75 14.5 10.7 11.45 3.05 DN-WS-14/11 13.75 14.5 11.45 12.2 2.3 DN-WS-14/11.8 13.75 14.5 12 12.75 1.75 DN-WS-14/12.3 13.75 14.5 10.95 11.7 2.8 DN-WS-14.1/11.3 13.75 14.5 11.7 12.45 2.05 DN-WS-14/12 17.3 18.1 11.7 12.5 5.6 DN-WS-17.7/12.1 Ka-Band 29.5 30 19.2 19.7 10.3 DN-WS-29.75/19.45 29.5 30 19.7 20.2 9.8 DN-WS-29.75/19.95 29 30 19.2 20.2 9.8 DN-WS-29.5/19.7 30 31 20.2 21.2 9.8 DN-WS-30.5/20.7 RF Transmit-Band to L-Band 5.85 6.65 0.95 1.75 4.9 DN-WS-6.25 5.925 6.425 0.95 1.45 7.375 DN-WS-6.175-INV 7.9 8.4 0.95 1.45 6.95 DN-WS-8.15 12.75 13.25 0.95 1.45 11.8 DN-WS-13 14 14.5 0.95 1.45 13.05 DN-WS-14.25 13.75 14.5 0.95 1.7 12.80 DN-WS-14.125 14.5 14.8 0.95 1.25 13.55 DN-WS-14.65 17.3 18.1 0.95 1.75 16.35 DN-WS-17.7 Ka-Band 28.35 28.6 0.95 1.2 27.4 DN-WS-28.475 29.25 29.5 0.95 1.2 28.3 DN-WS-29.375 29.25 30 0.95 1.7 28.3 DN-WS-29.75 30 31 0.95 1.95 29.05 DN-WS-30.5 30 31 1 2 29 DN-WS-30.5-1 This equipment is designed for applications where frequency translation is needed with a minimum of amplitude and group delay distortion. Features Small weather resistant enclosure 30 db level control Local oscillator monitor port Output signal monitor port (L-band output only) Low phase noise Low intermodulation distortion RS422/RS485 and 10/100Base-T Ethernet Options Higher frequency stability Automatic 5/10 MHz internal/external reference selection Gain on transmit to L-band units

Specifications Test Translators Input characteristics Frequency Refer to model number table Return loss (50 ohms) 18 db minimum Non-damage level +10 db maximum Output characteristics Frequency Refer to model number table Return loss (50 ohms) 18 db minimum Signal monitor -20 dbc nominal (RF transmit-band to L-band only) Transfer characteristics Conversion loss 25 db maximum (RF transmit-band to RF receive-band), 15 db maximum (RF transmit-band to L-band)/(20 db gain optional) Level control 30 db in 0.2 db steps Conversion loss stability ±0.25 db/day at 23 C Amplitude response ±0.25 db/40 MHz maximum, ±1 db maximum over RF frequency band Intermodulation -50 dbc minimum at -5 dbm input Frequency stability 5 x 10-6 /day (-40 to +60 C) Input/output isolation 60 db minimum Mute function 60 db minimum Remote control 10/100Base-T Ethernet interface providing: HTTP-based web server SNMP 1.0 configuration Alarm reporting via SNMP Trap Telnet access Password protection and selectable RS485/422 Gain control is 30 db in 0.2 db steps Phase Noise Specifications -20 PHASE NOISE CHARACTERISTICS PHASE NOISE (dbc/hz) -40-60 -80-100 -120 27 30 GHz Local oscillator (LO) -4.9 to 9 GHz -above 9 GHz -above 3.1 GHz INTELSAT IESS 308/309 16 20 GHz Maximum external reference (Option 10 and 17 only) -140 10 Hz 100 Hz 1.0 KHz 10 KHz 100 KHz 1.0 MHz FREQUENCY OFFSET FROM CARRIER

Options 11. Gain on transmit to L-band units Gain... 20 ±3 db Power output (1 db compression)... 18 dbm minimum Gain slope... 0.03 db/mhz maximum Gain stability... ±0.25 db/day maximum at constant temperature Intermodulation distortion (third order)... With two inband signals at 0 dbm output, third order intermodulation products are less than 60 dbc minimum and 50 dbc minimum (Ka-band units). 17. 30 db additional level control. 18. LO level detect. 19. Input filter. 10. Higher frequency stability reference. External 5 or 10 MHz at +4 ±3 dbm. If external reference is below +1 dbm nominal, the converter will automatically lock to the internal reference. Reference oscillator acts as an analog phase lock with a 0.1 Hz nominal loop bandwidth. Typical loop suppression of the external reference is as follows: -28 db at 1 Hz offset; 65 db at 10 Hz offset and 100 db at 100 Hz offset. Internal oscillator is available with the following stabilities: A. ±5 x 10-8, -40 to +60 C, 1 x 10-9 /day typical (fixed temperature after 24 hour on time). B. ±1 x 10-8, -40 to +60 C, 1 x 10-9 /day typical (fixed temperature after 24 hour on time). C. ±5 x 10-9, -40 to +60 C, 1 x 10-9 /day typical (fixed temperature after 24 hour on time). Note: Translator may require 7-10 days to reach stability after long storage periods. 19. DC power input. A. +24 to +32 VDC input B. +42 to +60 VDC input C. -42 to -60 VDC input Note: For literature describing local control (front panel) and remote control (bus control), refer to MITEQ s Technical Note 25T060. Missing option numbers are not applicable for this product.

General Specifications Primary Power Requirements Voltage... 90 250 VAC Frequency... 47 63 Hz Consumption... 12 W typical Physical Weight... 15 pounds (6.8 kg) nominal Front panel connectors RF band... N female (below 15 GHz), SMA female compatible (above 15 GHz), WR28 (Ka-band above 27 GHz) L-band... N female L-band monitor... SMA female External reference input... SMA female Status monitor... MS3116F14-18P* Remote interface... RJ-45 female for Ethernet, RS422/485 available on status connector Primary power input... FCI clipper series CL1M1102* *Note: Unit supplied with mating connector. Environmental Operating Temperature... -40 to +60 C Atmospheric pressure... Up to 10,000 feet Nonoperating Temperature... -50 to +70 C Atmospheric pressure... Up to 40,000 feet Shock and vibration... Normal handling by commercial carriers

Translator Outline Drawing 12.61 [320.29] ±0.06 [1.52] 1/4-20 TAPPED THRU, #10 CLEARANCE HOLE 4 PLACES 7.50 [190.50] 12.26 [311.40] ±0.06 [1.52] 3.38 [85.85] AC INPUT 7.88 [200.15] 6.63 [168.40] TEST TRANSLATOR J3 T1.25A/250V LINE 90-250 VAC 47-63 Hz 250 VA MAX J4 EXT. REF. INPUT 5/10 MHz +4 ±3 dbm J2 LO MON POWER SUMMARY EXT. REFERENCE INPUT MONITOR OUTPUT (L-BAND ONLY) CONNECTOR BREATHER VALVE STATUS LEDs J6 J1 10-32 GROUND SCREW NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.

For Satellite Communications Ka-Band Translator Outline Drawing 12.61 [320.29] ±0.06 [1.52] 1/4-20 TAPPED THRU, #10 CLEARANCE HOLE 4 PLACES 7.50 [190.50] 1.83 [46.48] 12.26 [311.40] ±0.06 [1.52] 3.38 [85.85] AC INPUT 6.63 [168.40] TEST TRANSLATOR J3 T1.25A/250V LINE 90-250 VAC 47-63 Hz 250 VA MAX J4 EXT. REF. INPUT 5/10 MHz +4 ±3 dbm POWER SUMMARY J2 7.88 [200.15] EXT. REFERENCE INPUT CONNECTOR BREATHER VALVE STATUS LEDs 1.83 [46.48] 2.02 [51.31] J6 J1 10-32 GROUND SCREW 0.68 [17.27] NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS. D-340B /01.24.12 100 Davids Drive, Hauppauge, NY 11788 TEL.: +1-631-436-7400 FAX: +1-631-436-7431 www.miteq.com Specifications are subject to change without notification.