F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Similar documents
Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Operating instructions Electronic preset counter Type series 717

Multifunction Digital Timer

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

48x24. Options ORDER NUMBER OF TYPE PFL B

02/11/2015

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

Solid-State Digital Timer

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Model IQ4-PC User Manual Revision Date:

Electronic Pulse Counter Combination device

Flexible Counter Series in DIN size 24 x 48 mm

Frequency/Rate Meter

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Hour Meters / Timers, electronic

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Multifunction devices

Absolute Rotary Encoder E6CP

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Digital Flow Switch for Large Flow

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Operating Instructions

Standard signal metering in wall-mounting case

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

GC30 Digital Differential Pressure Gauge Operation Manual

XTM72E & F Real-Time Clock Modules

EVENT INPUT/OUTPUT MODULE [PUME]

Flexible Counter Series in DIN size 24 x 48 mm

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Single Axis Position Controller

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Assembly. Front view. LEDs. Parametrization interface. Power Bus

VA13 INSTALLATION & OPERATING INSTRUCTIONS

BC104 BATCH CONTROLLER

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

DA E: Series of Narrowband or Wideband Distribution Amplifiers

263 Series LED Bargraph Indicator and Controllers

Ø50mm Shaft Multi-Turn Absolute Type

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Magnetic Sensor - Incremental EHP

Preset counters, electronic

Input type NPN/Voltage pulse PNP 240 VAC

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

SIGNET 5500 Flow Monitor ENGLISH

USER S MANUAL. FX2N-8AD Analog input block

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

K3NX Process Meter OPERATION MANUAL

Time meter electronic

Solution Selection Guide

Material: Weight: IP Rating: Cable: Connector:

Digital Flow Switch for Air/Water

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

C200H-AD002/DA002 Analog I/O Units Operation Guide

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

The measurements are stored in non-volatile memory, which retains data even when the power down.

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

SCALE & WEIGHT DISPLAYS

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Analogue output module DAO 081

INTRODUCTION INTRODUCTION

DA : Series of Narrowband or Wideband Distribution Amplifiers

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

FRQM-2 Frequency Counter & RF Multimeter

E R A I GATE OPENERS DEPARTMENT

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Programmable Counter/Timer CT Series. User Manual. CT Series. CT Series

Kuhnke Technical Data. Contact Details

Eaton Durant. Counters, process instruments and hour meters.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

THE ASTRO LINE SERIES GEMINI 1000/2000 INSTRUCTION MANUAL

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Transcription:

F90 Series (Rate Indicators / Controllers) INSTRUCTI MANUAL FEATURES DIN 48 9mm DIN 48 9mm Standard Panel Size Monitor & Preset Type 1 Monitor type with the large display 2 Preset Type can make the upper/lower limit output Decimal Point Positioning By selecting the decimal point position it will be available to display the measured data of below the decimal point 1 / TAU High precision from low speed to high speed by 1/TAU Measuring range is 011Hz ~ 20kHz Input Correspond to each input mode of Contact Open Collector Voltage and Magnetic Sensor Up-Date Time Regardless of sampling time it will be available to set the up-date time Prescale Available to multiplier and divider at once correspond to any revolution ratio and circumference ratio Analog Output With option prepared the Analog output Key Lock and Output Inhibition By easy wirings key lock (front key operation lock) and output inhibition are available MODELS MODEL FUNCTI NUMBER OF DIGITS SETTING DIGITS ADDED FUNCTI F90 101 Monitor Type F90 103 ANALOG OUTPUT F90 201 Preset Type F90 203 ANALOG OUTPUT FRT PANEL & DIP SWITCH LINE SEIKI prescale value upper limit output lamp multiplier lower limit output lamp divider upper limit setting lamp lower limit setting lamp up date time operation key UP LO / LINE SEIKI prescale value multiplier up date time upper/lower limit setting value divider / : Alternate display of upper limit and lower limit value : Enter to mode and change digit for editing Call of the prescale value Used for the decimal point positioning LINE SEIKI : Increase the numerical value of the setting digit Used for the decimal point positioning : Decrease the numerical value of the setting digit Used for the decimal point positioning For changing of analog output range Dip switch (Black) For changing of input type Dip switch (Black) : Memory of the selected numbers Call of the prescale value : Call of the up date time

EDITING < PRESCALE VALUE > For prescale both multiplier and divider can be set The formula on displayed value and the prescale value is the following Display Value = Multiplier Divider Number of Input Pulse For example in case of fitting the 200 ppr encoder on the roller which circumference is 50 cm and making the roller s surface speed display at cm/min set the multiplier at 50 and divider at 200 OPERATI EXPLANATI OF OPERATI MITOR TYPE : F90 101 103 PRESET TYPE : F90 201 203 key and with key pressed + Present prescale value will be displayed The display returns to measuring mode if key is pressed or key is not pressed within 3 seconds while present prescale value appears multiplier=1 multiplier=1 divider=1 key to enter multiplier editing mode and make the leftmost digit blink key 5 times or continue to press to set the leftmost digit to be 5 key once to make the next digit flash key once to set 0 to this flashing digit key times or continue to press to shift the flashing digit for editing key while the rightmost digit of the multiplier is flashing Then the display will enter divider editing mode and the leftmost digit will blink divider=1 key twice to set 2 to this flashing digit editing key twice to shift flashing digit for key once to set 0 to this flashing digit key to stop flashing of digit and memory the selected numbers The display returns to measuring mode after 3 seconds automatically or by pressing key again In case of setting the multiplier to be 000000 this means the multiplier is 100 In case of setting the divider to be 0000 this means the divider is 1

< UP DATE TIME > By setting the up-date time the display can be renewed at reasonable time without renewing the display in every sampling For example if you hope that display renews every 28 seconds set 28 for the up-date time OPERATI DESCRIPTI MITOR TYPE : F90 101 103 PRESET TYPE : F90 201 203 key to display present up-date time The display returns to measuring mode if key is pressed or key is not pressed within 3 seconds while present up-date time appears left digit flash key to enter editing mode and make the key twice to set 2 to this flashing digit key once to shift flashing digit for editing key twice to set 8 to this flashing digit key to stop flashing of digit and memory the selected numbers The display returns to measuring mode after 3 seconds automatically or by pressing key again In case of setting the up-date time to be 00 this means the up-date time is equal to the sampling time In case of except for 00 the display shows newest measured data every up-date time passed But it shows newest measured data at once if the status of upper or lower output is changed by comparing calculation of every sampling time < DECIMAL POINT POSITIING > By using the decimal point positioning function the display can shows up to the 4th digit below decimal point of measured data In case of the upper/lower limit type the decimal point position of preset display shifts automatically corresponding to the decimal point of measuring display OPERATI DESCRIPTI MITOR TYPE : F90 101 103 PRESET TYPE : F90 201 203 + Whenever key is pressed while both and key are pressed decimal point shifts and be determined

< UPPER / LOWER LIMIT OUTPUT > F90 201 202 203 can set upper lower limit to compare with measured data and to output For example when output for upper limit should be at 180000 and output for lower limit should be at 9200 set upper limit for 180000 and lower limt for 9200 OPERATI DESCRIPTI UPPER LIMIT 180000 OPERATI DESCRIPTI UPPER LIMIT 180000 / / key to display preset upper limit value and to turn the lamp / / key to display preset lower limit value and to turn the lamp leftmost digit flash key once to make the the 4th digit key three times to make flashing digit for 1 key once to set this flashing digit for 9 key 9 times to set this digit for editing key once to shift flashing digit for editing key once to shift flashing flashing of digit for 8 key twice to set this flashing digit for 2 key twice to set this key to stop flashing of digit and to memory the selected numbers key to stop flashing of digit and to memory the selected numbers Regardless of up-date time the measured data is compared with the upper/lower limit value in every sampling time In this case displayed data of digits which is decided to be displayed by decimal point positioning function is compared with upper or lower limit data and not displayed data is no concern with comparison MEASURED DATA AND COMPARED OUTPUT Example : Upper Limit = 180000 Lower Limit = 9200 UPPER LIMIT (180000) LOWER LIMIT (9200) UPPER LIMIT OUTPUT LOWER LIMIT OUTPUT OUTPUT I Upper limit < measured data ; make upper limit output and short N O and COM of relay (terminal No 11 and 12 = ) Upper limit measured data ; make upper limit output and short N C and COM of relay (terminal No 13 and 12 ) Lower limit measured data ; make lower limit output and short N O and COM of relay (terminal No 14 and 15 ) < < = < Lower limit measured data ; make lower limit output and short N C and COM of relay (terminal No 1 and 15 ) If inhibition output is upper limit output turn to at the lowest sampling time

WIRING AND REAR TERMINALS Type Monitor Type Upper / Lower Limit Preset Type Model F90 101 103 F90 201 203 INPUT ANALOG * INPUT ANALOG * Rear Terminals IN 1 11 12V PS I E GND2 2 3 4 12 13 14 5 15 1 7 8 17 18 FG 9 10 19 20 IN 1 11 NO 12V OUT SET PS I E GND2 2 3 12 13 4 5 14 15 7 1 17 COM NC NO COM NC FG 8 9 18 19 10 20 RESET POWER OUT UP OUT LO RESET POWER * F90 103 LY * F90 203 LY Power Source and Earth 18 19 20 Supply 100 ~ 240VAC to terminal No and Earth terminal No 18 in case of need 19 20 CTACT OPEN COECTOR VOLTAGE PSE MAGNETIC SENSOR - (NPN) NPN Input 1 2 1 2 1 2 1 2 IN IN IN IN By type of input signal set dip-switch (Black) on your right side Comparison Output 11 12 13 14 15 1 11 14 NO COM OUT UP 12 15 13 1 NC NO COM OUT LO NC : UPPER LIMIT OUTPUT : LOWER LIMIT OUTPUT CTACT INPUT OPEN COECTOR INPUT Output Inhibition 4 5 4 5 OUT Short terminal No 4 and 5 comparison output mode will be inhibited OUT Key Lock CTACT 4 7 4 7 SET PS OPEN COECTOR INPUT SET PS Short terminal No & 4 the change of upper / lower limit and up-date time will be disabled (except monitor type) Short terminal 7 & 4 the change of prescale will be displayed Analog Output ANALOG I E GND2 8 9 10 - Terminal No 8 ; current output - Terminal No 9 ; voltage output - Terminal No 10 ; common of analog output (Select current output or voltage output) Select the key of output by dip-switch (Black) on your left side Analog output is adjusted by the volume beside dip-switch Analog output is converted directly from frequency of input signal and no concerned with prescaler function Do not use the terminal No 5 11 ~ 17 of F90 101 103 and the terminal No 17 of F90 201 203 Writing of terminal No 8 9 10 for analog output is available for model F90 103 203 only

SETTING FOR SAMPLING TIME The sampling time can be set in the range of the following diagram KEY OPERATI LAY NOTE 1 + The cross reference between setting value and sampling time is following diagram When the display is indicating the measuring display press key and the same time key at (Existing setting value) * This value is set to 0 on ex-factory 2 ~ ~ ( If the or is not pressed within 3 secs the display returns to the measuring display automatically ) or key to blink existing setting value By using these keys select the favorite setting value 3 The display returns to the measuring display by pressing key or 3 sec later automatically key to make setting value memorize CROSS REFERENCE BETWEEN SETTING VALUE AND SAMPLING TIME Setting Value 0 9 8 7 5 4 3 2 1 Sampling Time (seconds) Minimum Input Frequency (Hz) Converging Time (seconds) 05 ~ 10 01000 10 ~ 20 05 ~ 9 01112 9 ~ 18 05 ~ 8 01250 8 ~ 1 05 ~ 7 01429 7 ~ 14 05 ~ 017 ~ 12 05 ~ 5 02000 5 ~ 10 05 ~ 4 02500 4 ~ 8 05 ~ 3 03334 3 ~ 05 ~ 2 05000 2 ~ 4 05 ~ 1 10000 1 ~ 2 Converging time means the time duration to make the display showing 0 after input pulse ends Shortest converging time is equal to the sampling time and longest one is double of sampling time For a sampling time and converging time refer to the cross reference between setting value and sampling time DIP SWITCHES For Input Switch (Black) Input No SW1 SW2 SW3 Open Collector Input Voltage Input Magnetic Sensor Input Contact Input For analog output range (Black) F90 103 203 Range No SW1 SW2 SW3 SW4 Voltage Output Current Output 20Hz ~ 200Hz 1-10V (frequency Hz X 005V) 5-20mA (frequency Hz X 008mA + 4mA) 20Hz ~ 2kHz 01-10V (frequency Hz X 0005V) 41-20mA (frequency Hz X 0008mA + 4mA) 200Hz ~ 20kHz 01-10V (frequency Hz X 00005V) 41-20mA (frequency Hz X 00008mA + 4mA)

SPECIFICATIS Type Monitor Type Upper / Lower Limit Preset Type MODEL F90 101 F90 201 (Additional Function) F90 103 (ANALOG output only) F90 203 (Upper Limit Lower Limit and ANALOG output) Display Number of Digits Display Range Decimal Point Position Scale Range Preset Level Measuring Method Measuring Accuracy Sampling Time Up-date Time Input Signal Input Frequency Prescale Overflow Memory Keylock Output Inhibition Upper / Lower Output Analog Output (For type 103 203) Sensor Supply Power Source Power Supply Power Consumption Operating Temperature Operating Humidity Front Panel Weight Red LED 1422 78mm Measuring Display: Red LED 100 55mm Preset Display: Green LED 80 40mm 00001 ~ 999999 Maximum : Decimal point 4th 011Hz ~ 20KHz (1 pulse/ revolution : 7rpm ~ 120000rpm) Upper / Lower Limit 1/TAU standard sampling : X tal 2MHz ± 50ppm ±0008% reading ±1 digit (multiplier = 10000 divider = 1) 05 ~ 10 seconds (sampling time is changed automatically by pulse interval) Every sampling or 1 ~ 99seconds (maximum) Contact input Open collector input Voltage input Magnetic sensor input Contact input Open collector or Voltage input Magnetic sensor input : sink current 2mA : sink current 2mA : input impedance 3KΩ : input impedance 3KΩ : 011Hz ~ 25Hz : 011Hz ~ 20KHz : 011Hz ~ 20KHz L : 0~19V L : 0~19V H : 35 ~ 30V (P-P35Vmin) L : -0 ~ -17 H : 0 ~ 17V minimum pulse width 20µsec minimum pulse width 25µsec minimum pulse width 25µsec (L : -0Vmax H : 0Vmin) Multiplier : 00001 ~ 100 Divider : 1/1 ~ 1/9999 (available to use at the same time) At every sampling when the measured data is over digits ----------------------- is displayed Prescale value upper/lower limit value and up date time are reserved for 10years by E²PROM (rewrite 10000 times) Prescale value upper/lower limit value (exclude monitor type) and up date time are inhibited to be changed Contact input Open collector input (sink current 7mA L : 2Vmax) 12VDC ±10% 100mA max (Analog output is 50mA maximum) 100 ~ 240VAC -15% +10% (85 ~ 24VAC) 50/0Hz Approximately VA -5 ~ 50 C (Non freezing) 45 ~ 85% RH (Non condensing) IP54 Standard Approximately 280g Upper / Lower Limit output inhibition Contact input Open Collector input (sink current 7mA L : 2Vmax) Each 1C relay contact (250VAC 05A/30VDC 2A ; load) Frequency voltage converter method Voltage Output : 01 ~ 10V (1KΩ min) ±05%FS Current Output : 41 ~ 20mA (500Ω max) ±05%FS Output Ripple : 20mVp-p max 3 types of range 20Hz ~ 200Hz or 20Hz ~ 2KHz 200Hz ~ 20KHz can be selected by dip-switches (Select voltage output or current output) DIMENSIS MIIMETERS 48 445 9 2 998 918 (10) +0 +08 Panel Cutout 45 0 92 0 LINE SEIKI CO LTD 37-7 CHUO-CHO 2-CHOME MEGURO-KU TOKYO JAPAN 152-0001 TEL: +83-3-371-5151 FAX: +83-3-3710-4552 E-MAIL: webtrade@linecojp URL: http://wwwlineseikicom This manual was last revised March 25 2010 4F90001C *Subject to change without prior notice All Rights ReservedCopyright 2010LINE SEIKI COLTD