Pendant Light Fitting IEC Series 6470/2

Similar documents
Pendant Light Fittings Series 6050

7 Lighting Technology

Explosion Proof Audible Signal db(a) Series YA60

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX 6480 Series

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Explosion Proof Audible Signal db(a) Series YA60

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Circuit-Breakers for Motor Protection Series 8523/8

Operating instructions

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

EXPlora. Introduction

Motor Protection Circuit Breaker Series 8146/5-V27

8 Installation Equipment

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

I Ex-protected connectors exlink I

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

LIGHTING SOLUTIONS. The bright side of the ship

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

Champ-Pak Wall Pack Luminares

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Inductive sensor BI1.5-EG08K-Y1

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Inductive sensor NI3-EG08K-Y1-H1341

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PROPORTIONAL VALVES Sentronic plus

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Inductive sensor With analog output BI15-M30-LI-EXI

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Optical Signal Devices. Free-standing Beacons

Horn loudspeaker, Ex proof, short/long flare

Applications. Standard Materials

TYPE APPROVAL CERTIFICATE

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

XML LED X M L L E D. Explosionproof Linear LED Lighting

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Inductive sensor NI10-M18-Y1X-H1141

Nessie Coils for VDH and VDHT valves

Coils for solenoid valves

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

WLB SERIES HID Lighting for Hose Down Applications

Model JDF Field Indicator

Illustrated Feature. Options

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Linear flow control with actuator IFC

Panel-mounting thermostats, type series EM

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

ExCam XPT Q6055. User Manual

TFRN Industrial RTD temperature sensor. CombiTemp TM

82540/ /2-way diaphragm valves

Modular pulse operated latching relay 16 A

Pressure transmitter For applications in hazardous areas Model IS-3

Safety dialogue solutions

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Mechanical flow switch for On/Off control

3 Large Housing. Assembly Guide. To order a UNIPAK fixture, see page 29. Complete luminaire consists of : To order separate components, order

DMP 331i / DMP 333i LMP 331 i

Parts List _2.1. Flygt /.890

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections


CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Revision 1.0 Parts List Minor

PMG. Vibration Energy Harvesters

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

TFRH Hygienic RTD temperature sensor. CombiTemp TM

NEC/CEC: Simultaneous Exposure (Class I, Division 2/Class II, Division 1) Fixtures Outside Type (Salt Water) Type 4X IP66. Standard Materials

S020 fluorescent tube luminary

Parts List _2.1. Flygt /.190

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Installation instructions Ex frames

Revision 2.0 Parts List Minor

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

3 Cleaning. 4 Technical data

Installation instructions Cable transit device Roxtec RS ES Ex

LED HIGHBAY I-VALO XENRE

Flow Measurement SITRANS F M

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Single Point Flow Monitor SW118 SW119

Panel-mounting Thermostats EM Series

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Linear flow controls VFC Linear flow controls with actuator IFC

TFRN Industrial RTD temperature sensor. CombiTemp TM

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

RSCC. Load cells. Special features. Data sheet

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Transcription:

> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x Explosion Protection Global (IECEx) Gas and dust IECEx PTB 06.0007 Ex nr IIC T* Gc Ex tb IIIC T* C Db Ex tc IIIC T* C Dc * temperature classes and surface temperatures see selection table Europe (ATEX) Gas and dust PTB 05 ATEX 2045 (Zones 2, 22) PTB 05 ATEX 2043 (Zone 21) E II 3 G Ex nr IIC T* Gc Certifications and certificates Certificates Ship approval E II 2 D Ex tb IIIC T* C Db E II 3 D Ex tc IIIC T* C Dc * temperature classes and surface temperatures see selection table IECEx, ATEX, Kazakhstan (TR), Russia (TR), Ukraine (TR), Belarus (TR) GL WebCode 6470C Lighting /1

Selection Table Version Assembly Cable glands Lamps 1) Lamp holder Lamp wattage Temperature class at Ta = Surface temperature at Ta = Order number Art. no. Weight 40 C 55 C 55 C kg Pendant light fitting, size 1 with compensation, without wire guard Pendant light fitting, size 2 with compensation, without wire guard Pendant light fitting, size 3 with compensation, without wire guard Wall - Ceiling Pole 25 2 x M20 x 1.5, HIE 7 100 W T4 T4 125 C 6470/2121-2101-100-2 237869 8.400 150 W T4 T3 147 C 6470/2121-2151-100-2 237881 9.200 HSE 7 70 W T4 T4 112 C 6470/2121-3071-100-2 237857 8.300 1 1 / 2 BSP HSE 7 70 W T4 T4 112 C 6470/2153-3071-100-2 241134 8.600 1 1 / 4 BSP HIE 7 100 W T4 T4 125 C 6470/2152-2101-100-2 237871 8.600 Wall 2 x M20 x 1.5, Wall - Ceiling Pole 25 2 x M20 x 1.5, 150 W T4 T3 147 C 6470/2152-2151-100-2 237883 9.400 HSE 7 70 W T4 T4 112 C 6470/2152-3071-100-2 237859 9.400 HIE 7 100 W T4 T4 125 C 6470/2141-2101-100-2 237870 9.000 150 W T4 T3 147 C 6470/2141-2151-100-2 237882 9.900 HSE 7 70 W T4 T4 112 C 6470/2141-3071-100-2 237858 9.000 HSE E40 100 W T4 T4 117 C 21-3102-100-2 237875 8.700 150 W T4 T3 140 C 21-3152-100-2 237887 9.600 HID E40 250 W T3 T3 (HSE) -- (HIE) 167 C (HSE) 152 C** (HIE) 21-6252-100-2 224250 9.700 1 1 / 2 BSP HSE E40 100 W T4 T4 117 C 53-3102-100-2 224344 9.100 150 W T4 T3 140 C 53-3152-100-2 224345 9.950 1 1 / 4 BSP HSE E40 100 W T4 T4 117 C 52-3102-100-2 237877 9.100 Wall 2 x M20 x 1.5, Wall - Ceiling Wall 2 x 1 / 2 NPT, 2 x M20 x 1.5, 2 x 1 / 2 NPT, 2 x M20 x 1.5, 150 W T4 T3 140 C 52-3152-100-2 237889 9.100 HID E40 250 W T3 T3 (HSE) -- (HIE) 167 C (HSE) 152 C** (HIE) 52-6252-100-2 224252 9.960 HSE E40 100 W T4 T4 117 C 41-3102-100-2 237876 9.400 150 W T4 T3 140 C 41-3152-100-2 237888 10.300 HID E40 250 W T3 T3 (HSE) -- (HIE) 167 C (HSE) 152 C** (HIE) HID E40 250 W T4 T3 145 C (HSE) 136 C (HIE) 400 W T3 T3 154 C (HSE) 162 C (HIE) HID E40 250 W T4 T3 145 C (HSE) 136 C (HIE) 400 W T3 T3 154 C (HSE) 162 C (HIE) HID E40 250 W T4 T3 145 C (HSE) 136 C (HIE) 400 W T3 T3 154 C (HSE) 162 C (HIE) HID E40 250 W T4 T3 145 C (HSE) 136 C (HIE) 400 W T3 T3 154 C (HSE) 162 C (HIE) 41-6252-100-2 224251 10.400 6470/2327-6252-100-2 224350 14.000 6470/2327-6402-100-2 224351 16.700 6470/2321-6252-100-2 224254 14.000 6470/2321-6402-100-2 224255 16.700 6470/2347-6252-100-2 224354 15.900 6470/2347-6402-100-2 224355 18.600 6470/2341-6252-100-2 224257 15.900 6470/2341-6402-100-2 224258 18.600 Notes: 1) HIE HSE HID Metal halide lamp High-pressure sodium lamp (HIE + HSE) ** at ambient temperature T a = 40 C - - The light fittings are supplied without lamps. The light fittings are compensated. /2 Lighting

Technical Data Electrical data Lamps QT IEC 60357 HIE IEC 61167 HSE IEC 60662 Ballast QT without Rated operational voltage U e HIE / HSE magnetical ballast Lamps QT HIE/HSE Current consumption 150 W 250 W 500 W 230 (+/- 6%) V AC, 50 Hz x x x x x x x x 240 (+/- 6%) V AC, 50 Hz x x x x x 208 (+/- 6%) V AC, 60 Hz x x x 220 (+/- 6%) V AC, 60 Hz x x x x x x x x 240 (+/- 6%) V AC, 60 Hz x x x x x Lamp Lamp power Supply current in A 220... 230 V AC/DC 0, 50, 60Hz QT 150 W 0.65 QT 250 W 1.08 QT 500 W 2.17 70 W 100 W 150 W 250 W 400 W Lamp Lamp power Compensated Power factor cos φ Supply current in A Inrush current in A Uncompensated Power factor cos φ Supply current in A Inrush current in A 230 V AC / 240 V AC, 50 Hz HIE / HSE 70 W 0.96 0.38 0.50 0.37 1.00 1.30 HIE / HSE 100 W 0.90 0.56 0. 0.41 1.20 1.70 HIE / HSE 150 W 0.95 0.79 1.50 0.40 1. 2.70 HIE / HSE 250 W 0.92 1.30 2.00 0.40 3.00 4.20 HIE 400 W 0.93 2.00 2.40 0.43 4.20 5. HSE 400 W 0.91 2.10 2.50 0.43 4.45 6.00 208 V AC, 60 Hz HIE / HSE 70 W 0.92 0.39 0.50 0.37 1.00 1.30 HIE / HSE 150 W 0.94 0, 1.50 0.42 1. 2.70 HIE 400 W 0.97 1,90 2.50 0.44 4.20 5. HSE 400 W 0.96 2,30 2. 0.44 4.45 6.00 220 V AC / 240 V AC, 60 Hz HIE / HSE 70 W 0.95 0.36 0.50 0.37 1.00 1.30 HIE / HSE 100 W 0.91 0.62 0. 0.44 1.20 1.70 HIE / HSE 150 W 0.96 0.75 1.50 0.42 1. 2.70 HIE / HSE 250 W 0.90 1.50 2.00 0.40 3.00 4.20 HIE 400 W 0.98 1. 2.40 0.44 4.20 5. HSE 400 W 0.98 2.20 2.70 0.44 4.45 6.00 Lighting /3

Technical Data Inrush current max. light fittings per circuit breaker with the maximum network impedance of 1 Ohm: compensated [uncompensated] QT HIE/HSE 150 W 250 W 500 W 70 W 100 W 150 W 250 W 400 W B10A 11 7 4 8 [5] 7 [4] 5 [2] 3 [1] 2 [1] B16A 22 13 7 13 [8] 11 [6] 8 [4] 5 [2] 3 [1] B20A 28 17 9 16 [9] 14 [8] 10 [5] 6 [3] 4 [2] B25A 35 21 11 20 [12] 17 [10] 12 [6] 8 [4] 5 [2] C10A 11 7 4 12 [7] 10 [6] 7 [4] 5 [2] 3 [1] C16A 22 13 7 18 [11] 16 [9] 11 [6] 7 [3] 4 [2] C20A 28 17 9 23 [14] 20 [11] 14 [7] 9 [4] 5 [3] C25A 35 21 11 29 [17] 25 [14] 17 [9] 11 [5] 7 [4] Energy efficiency class Ambient conditions Ambient temperature EEI A2-30... +55 C HSE, HIE -30... +40 C 250 W HIE (Size 2) -50... +55 C QT Mechanical data Degree of protection IP66 (IEC 60598) Protection class I (PE-connection) Material Enclosure material saltwater-resistant aluminium Glass cover thermal shock resistant borosilicate glass Cover seal silicone rubber Glass seal silicone rubber Mounting bracket Stainless steel External reflector glass fibre reinforced polyester Wire guard saltwater-resistant aluminium Enclosure lock Mounting screw M8 (stainless steel) Mounting / Installation Operating position pendant mounting or slewing angle (30 and ) Mounting Cover Mounting Description Universal Cover Wall Ceiling (pendant) Ceiling (fix) with help of mounting bracket as accessory with help of ring bolts as accessory with help of mounting bracket as accessory Wall cover Wall direct on a wall Pole 25 cover Pole direct on a pole Cable glands Specially certified cable entries (according to Directive 94/9/EC) - risk of mechanical hazard "high" - with a minimum type of protection of IP66 must be used. The number of cable entries depends on the mounting version. Standard Special entry 2x M25 and 2x M20 others on request Connection option Spring clamp terminal 0.5... 4 mm 2 Strip length 10... 11 mm 3-pole (2x L1, 2x N, 2x PE) Screw-in thread for pole 1 1 / 4 BSP, 1 1 / 2 BSP mounting Wire guard and external can easily be mounted later using a mounting screw M6 reflector /4 Lighting

Light Distribution Curve (typical) 1 100 60 40 120 160 200 30 15 0 15 30 30 15 0 15 30 cd/klm η = 81% cd/klm η = 67% 18906E00 18907E00 6470 Size 1 without reflector 6470 Size 1 with reflector 1 60 40 120 160 200 30 15 0 15 30 cd/klm η = 83% 30 15 cd/klm 0 15 30 η = 69% 18908E00 18909E00 6470 Size 2 without reflector 6470 Size 2 with reflector Lighting /5

Light Distribution Curve (typical) 1 100 60 40 120 160 200 30 15 0 15 30 30 15 0 15 30 cd/klm η = 87% cd/klm η = 63% 18910E00 18911E00 6470 Size 3 without reflector 6470 Size 3 with reflector Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Power Lamp holder Voltage Light current Halogen lamps QT 205 W 7 230 V 4200 Im 203469 0.100 05355E00 150 W 7 230 V 2870 lm 207458 0.0 500 W E40 230 V 10250 Im 108874 0.120 Metal halide lamps HIE 04963E00 70 W 7 230 V 5100 Im 100 W 7 230 V 7700 Im 109307 0.073 109308 0.101 150 W 7 230 V 11500 Im 109309 0.110 250 W E40 230 V 20000 Im 108883 0.154 400 W E40 230 V 34000 Im 108885 0.242 High-pressure sodium lamps HSE 04963E00 50 W 7 230 V 3500 lm 70 W 7 230 V 5600 Im 109350 0.061 109105 0.054 100 W E40 230 V 9500 Im 109504 0.081 150 W E40 230 V 14500 Im 108900 0.285 250 W E40 230 V 27000 Im 108901 0.173 400 W E40 230 V 400 Im 108903 0.235 /6 Lighting

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg High-pressure sodium lamps HSE (TwinArc) 04963E00 50 W 7 230 V 4000 Im 70 W 7 230 V 6500 Im 109493 0.070 109494 0.059 100 W E40 230 V 9500 lm 150 W E40 230 V 17000 lm 109495 0.090 109496 0.160 250 W E40 230 V 32000 lm 109497 0.195 400 W E40 230 V 55000 lm 109498 0.237 Safety glass temperature resistant borosilicate glass with screw-in thread 10572E00 6470/21 123041 3.370 123051 4.400 6470/23 123052 6.600 Wire guard made of saltwater-resistant aluminium, with mounting parts for 6470/21 123038 0.250 10571E00 for 123039 0.300 123040 0.600 Standard reflector 10288E00 made of glass fibre reinforced polyester, with mounting parts 123048 1.900 123053 5.500 Reflector 30 made of glass fibre reinforced polyester, with mounting parts 123043 0.600 06249E00 Mounting bracket made of stainless steel, with mounting parts for 6470/.1 and 6470/.2 for 6470/.3 122757 1.200 122758 1.500 10570E00 Lighting /7

Accessories and Spare Parts Designation Illustration Description Art. no. Weight Cover for wall and ceiling mounting 105E00 Ceiling mounting via taps located on the cover. A mounting bracket or ring bolts can be attached to the cover later (must be ordered as accessory). 2 x M20 x 1.5 and kg 248973 1.364 2 x M20 x 1.5 and 248974 1,.177 2 x 1 / 2 NPT and 248975 1.575 2 x 1 / 2 NPT and 248976 1.388 Cover for wall mounting 2 x M20 x 1.5 and 248977 1.409 10573E00 2 x M20 x 1.5 and 248978 1.700 2 x 1 / 2 NPT and 248979 1.620 2 x 1 / 2 NPT and 2489 1.911 Cover for pole mounting 25 1 1 / 2 BSP 248981 1.694 10577E00 1 1 / 2 BSP 248982 3.076 1 1 / 4 BSP 248983 1.340 1 1 / 4 BSP 248984 3.076 Ring bolts Cable entries 05378E00 M8, direct mounting in insert nuts, 1 pair 115736 0.112 M10, direct mounting in insert nuts, 1 pair 118560 0.210 of moulded material, Series 8161 8161/7-M20-1304 50 pieces 239156 0.600 02055E00 8161/5-M25-1707 50 pieces 239157 1.000 Stopping plug of moulded material, Series 8290 04840E00 8290/3-M20 1 piece 143522 0.005 8290/3-M20 100 pieces 143543 0.500 8290/3-M25 x 1,5 1 pieces 143524 0.007 8290/3-M25 100 pieces 143544 0.700 /8 Lighting

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Special key Handheld testing instrument for gastight enclosures 05263E00 for tightening cable glands respectively cap nuts for cable glands thread size packing unit M20 x 1.5 1 For testing of restricted breathing of gastight enclosures of type Ex nr 114208 0.132 230434 1.334 11006E00 Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations Ceiling mounting without wire guard 10574E00 Ceiling mounting with wire guard 10566E00 Ceiling mounting with reflector 10564E00 Pendant mounting by means of ring bolts 10568E00 Lighting /9

Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 6470/21 6470/23 A 277 [10.91] B 352 [13.86] 414 [16.30] 372 [14.65] 514 [20.24] B2 331 393 498 C 230 [9.06] D 347 [13.66] E 240 [9.45] 310 [12.20] 525 [20.67] 329 [12.95] 10561E00 10563E00 Wall mounting Pole mounting 25 F 357 [14.06] G 1 1 H M 8 M 8 423 [16.65] 533 [20.98] 260 M 10 I 358 424 535 J 444 444 715 J1 340 367 511 K 20 20 L 18 18 Q 7 7 25 22.5 8 10567E00 Tube mounting S 105 125 160 T 405 466 592 V 105 105 X 366.5 366.5 139 579 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /10 Lighting