FIBRE OPTIC CABLE SOLUTIONS

Similar documents
OPTICAL FIBRE CABLE NETWORK 2004/1

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Section Communications Optical Fiber Backbone Cabling

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Ø 1000 * 588 mm 50 kg

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Revision No. 4 Page No. Page 1 of 7

Product Catalogue. Fibre Optic Cable

Empowering businesses through innovative network solutions.

FREEDM Loose Tube Interlocking Armored Cables

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

INSTALLATION INSTRUCTIONS

SECTION 4 TABLE OF CONTENTS

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Mining and Petrochemical Fiber Optic Cables

The FiberMark1 offers an ideal solution for

Detailed Specifications & Technical Data

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

ViaLiteHD Fibre Optic Green OEM Link Modules

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Fiber ICT. Optical Fiber Catalogue

SPECIFICATION. Optical Fiber Cable

RetractaNet XS. Extractable Solutions for OSP. October 2012

OPTICAL CABLE FIBER-LAN INDOOR

HCS - HES Cabling Systems

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

DOME OPTIC SPLICE CLOSURE

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

PREMIUM 5e F/UTP PRODUCTS

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

Medium Box for Cable Termination

SPECIFICATION. Spec No : VSS-1402-CS603B

TECHNICAL SPECIFICATION

3M Fiber Optic Wall Mount Enclosure 8430 Series

DIAMOND Fiber Optic Components

Connectivity accessories by Nestor Cables

EXPlora. Introduction

IP-LINX Fiber :: X-XXXX

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

LANmark-OF ENSPACE Patch Panel

Public Works Division Lighting District Fiber Optic Specifications April 2009

LD Series High Performance Loose Tube Fiberoptic Cables

SOLO ADSS Short-Span Cables, Fibers

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

Optical Distribution Box 300 Installation Guide. Version : R0.0

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Special Specification 6242 Special Fiber Optic Cable

ETSI ES V1.1.1 ( )

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

IP-LINX. Installation Guide

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2011 The Practicalities of Fibre Deployment Colin Kirkpatrick

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Triax TechInfo. Installing and pulling Fibre Optic cables

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Preferred ordering guide for NETCONNECT

Mini-breakout & Mini-bundle cable. Riser cabling solution

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

3M Fiber Closures BPEO

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Micro duct Cable with HDPE Sheath for Installation by Blowing

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

The World Of Professional Fiber Optics. safe flexible reliable

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Lensed Fibers & Tapered Ends Description:

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

PRO SERIES FIBRE-150M

TECHNICAL SPECIFICATION

FOSC 450 C6 and D6 Closures

Singlemode Patch Cords and Pigtails

Transcription:

point2point FIBRE OPTIC CABLE SOLUTIONS Introduction From patch-leads through to cross-site cables, or optical adapters through to patch panels, PPM s one-stopshop approach to fibre optic cable management offers a range of various high performance solutions designed to facilitate the quick and easy installation of all its fibre optic link products. Patch leads Our range of single-mode patch-leads can be ordered in lengths ranging from 0.5m up to 1km long and are terminated at either end with corresponding optical connectors to mate between your fibre optic link system and/ or patch panel. Can also be used to fusion splice to un-terminated fibre optic cables when used inside a Cable Termination Box (CTB) Patch-lead specification table Connector type FC/APC E2000/APC Compliance IEC 61754-13 IEC 61754-15 TIA 604-4-A TIA 604-16 Insertion loss at 1300nm 0.4dB 0.4dB Return loss >65dB >65dB Fibre type Jacket Single-mode 9/125µm SMF 28 tight buffered Self-extinguishing LSFH, very low fire load for high safety. Jacket diameter (mm) 2.5 ~ 3.0 Min bead radius (mm) during installation Patch-lead part number ordering information: F 6 R1 / XXXX 60 30 Cable type F = Fibre Optic Cable Patch-lead identifying characters Connector type 4=FC/PC 6=PC/APC 7=E2000 Assembly length Always four figures, measured in metres, up to a max of 1000 F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 1 of 6 Issue 1 CR 1943

Cross Site Cables To facilitate every possible on site installation requirement, PPM offers a range of fibre optic cross-site cabling solutions for customer specific indoor or outdoor applications. Choose between: Fully terminated indoor Fully terminated outdoor Un-terminated indoor Un-terminated outdoor Fully terminated cross-site cable assembly (indoor and outdoor applications) This solution can be installed within the shortest time via the use of dedicated waterproof and crush resistant pulling boots, fitted at one or both ends of the assembly. Each pulling boot protects the delicate fibre optic connectors during installation and can be readily removed once in situ, to offer the customer a virtual plug - n -play fibre optic cabling solution. Installation is done without the need for any on-site splicing or testing due to the optical connectors being factory fitted prior to despatch. Each cable can accommodate up to 12 optical connectors the required number being specified at time of order. Un-terminated cross-site cable (indoor and outdoor applications) Exactly the same cable type as utilised for the fully terminated cross-site cable can be supplied in varying lengths but without any optical connectors fitted. This solution would require the on site splicing of optical pigtails to the main fibre. The cable contains between 4 and 12 250µm optical fibres (dependant on cable choice and environment). Note on typical indoor applications for cross-site cable assemblies In general, fibre optic cables installed in an indoor environment are not exposed to the severe mechanical and environmental conditions that are experienced in the outdoor environment. They are usually protected within the confines of cable ducts (including riser applications), plant room and various other climatecontrolled indoor environments. Note on typical outdoor applications for cross-site cable assemblies Fibre optic cables installed in an outdoor environment are exposed to more severe mechanical and environmental conditions than are experienced in the protected, climate-controlled indoor environment. Outdoor installations (usually lashed aerially, pulled through duct, or directly buried in the ground) are subjected to combinations of ultraviolet (UV) radiation, standing water, ice, cable-gnawing rodents, temperature extremes and other outdoor-specific hazards. For normal external horizontal runs of fibre that do not exceed 3m in a vertical run, PPM recommends the use of its loose-tube jelly filled fibre optic cable in order to make the tube in which the fibre(s) reside longitudinally and transversely watertight. As the jelly in this cable is fairly viscous, PPM offer a loose-tube non-jelly filled alternative for external riser applications that exceed 3m in height. F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 2 of 6 Issue 1 CR 1943

Cross site Fibre optic Cable specification table Environment INDOOR OUTDOOR Description Tight buffered, secondary coated, non metallic multi core Loose tube (jelly filled), glass armoured single core Loose tube (non-jelly filled), glass armoured single core Number of Fibres per Cable 4 fibres 8 fibres 12 fibres 12 12 PPM part number 93228 93230 93231 93227 93233 Jacket diameter (mm) 5.0 6.0 7.0 8.5 8.5 Tight tube diameter (mm) with 1 fibre each 0.9 0.9 0.9 N/A N/A Weight (kg/km) 28 33 52 82 58 Tensile load (N) Min bead radius (mm) Crush resistance (N/cm) Temperature range in sevice in storage Number of connectors per end Jacket 1200 400 100 50 1800 300 2400 800 120 60 1800 300 3000 1000 130 70 1800 300-10 to +50-20 to +70-25 to +70 Between 4 and 12 (dependant on cable choice and part numbering specification) Self extinguishing LSFH, very low fire load for high safety 3000 1500 130 80 400 200-10 to +50-40 to +70-45 to +70 3000 1500 130 85 400 200-5 to +50-5 to +60-5 to +60 Between 2 and 12 (dependant on part numbering specification) UV resistant, self extinguishing LSFH, longitudinal/ transverse watertight, Rodent resistant Fibre type Single-mode 9/125µm SMF 28 UV resistant, self extinguishing LSFH, Rodent resistant Connector types available FC/APC, E2000 (APC) Fire propagation LSFH to IEC 60332-1 Length From 25m to 2km. Please contact PPM Sales F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 3 of 6 Issue 1 CR 1943

PPM part numbering system (terminated cross-site assembly) Cable type: 2 = External, jelly filled 4 = External, dry filled 5 = Internal, tight buffered Cable length in metres - always 4 digits. From 25 to a max of 2000 (+/ - 0.5M) in 5m steps Fibre Optic Cable F 0 4 4 0 1 6 6 / 0 0 5 0 Number of terminated fibres: 01 to 12 End A Pulling boot: 0 = Not fitted 1 = Fitted End B End A End B Connector type: 0 = none fitted 4 = FC/PC 6 = FC/APC 7 = E2000/APC (refer to PPM spec 81000-BS) The above example (F04-4-01-66/0050) is for a 50m length external jelly-filled cable assembly, terminated each end with 4 FC/APC connectors, and with a pulling boot on one end PPM part numbering system (un-terminated loose cable) 932XX/ XXXX PPM part number: Internal 4 core = 93228 Internal 8 core = 93230 Internal 12 core = 93231 External 12 core (jelly) = 93227 External 12 core (non-jelly) = 93233 Cable length in metres always 4 digits. From 25 to a max of 2000 (+/-0.5m) in 5m steps F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 4 of 6 Issue 1 CR 1943

Cable termination boxes (CTB): To facilitate the complete installation of either of the cross-site cables (terminated or un-terminated), PPM offers three application specific 19 1U high pressed aluminium cable termination boxes, each capable of accepting a maximum of 24 fibre optic adapters (based upon using two 12 way fibre optic Cables). Using the basic CTB part number (refer to matrix below), customers can order a set of parts that exactly matches and compliments the fibre management requirements applicable to the fibre cable as selected. CTB s for fully terminated cross-site cable assemblies The plug- n-play theme is continued with this CTB when used in conjunction with fully terminated crosssite fibre optic cable assemblies fitted with pulling boots, as no drilling is required to fit and tether the cable into position. Each pulling boot on the assembly is connected onto a moulded gland/ shoulder on the outer sheath of the cable and is easily removable after installation. This moulded shoulder incorporates the main strength member into its construction to take the full tensile load during deployment. The shape of the shoulder corresponds with a cut-out in gland-plate 29098, into which the shoulder of the cable is slotted and thus held captive, mitigating the need for cable gland nuts. Note : each CTB is capable of accepting two fibre Cable assemblies, therefore any unused positions should be covered with blank gland-plate 29114. Because terminated Cable assemblies are factory terminated with the customers preference to a specific optical connector, no on-site splicing of optical pig tails is necessary. Therefore terminated loose leads of the Cable can be quickly and neatly dressed around to the correct number of optical adapters on the internal face of the optical mating panel of the CTB. Simply select the correct number and type of optical adapters to suit the terminated Cable and correspondingly select the appropriate number of blanking caps to neatly dress any vacant positions. CTB basic part numbers Product Family Optical termination FC/APC E2000/APC ViaLite 75006 75007 point2point 75008 all CTBs supplied complete with fixing hardware to install into any standard 19 cabinet CTB s for un-terminated loose Cables The same basic CTB is employed for un-terminated cables as is utilised for fully terminated cross-site cable assemblies, except for the addition of a dedicated fusion splice management tray. The splice and fibre optic cable management tray is mounted within the CTB and is designed to assist the installation Engineer neatly dress and secure fusion spliced patchleads (refer to patchlead matrix for part numbers) into position whilst maintaining an adequate bend radius. In order to anchor the main cable into position, it is necessary for the customer to select the appropriate gland plate(s) and associative cable gland nut from the CTB accessory parts list matrix on the next page. F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 5 of 6 Issue 1 CR 1943

Gland plates (2 required per CTB) CTB accessories 29098 (for fully terminated cross-site cable assemblies) 29099 (for un-terminated loose cables) 29114 (for blanking off unused cable position) Gland nut (for un-terminated cables only) 92210 (PG11 suitable for 5-10mm cable diameters) 56172 FC/APC (complete with dust caps) Optical Adapters (for insertion into optical mating panel) 56181 E2000 (dust caps integral to adapter) 50061 Blanking caps (to blank vacant positions on (FC/APC) optical mating panel) 50062 (E2000) Fusion splice management tray (capable of 50063 accepting 24 fusion splices) (only for use on un-terminated loose cable) All fixing hardware supplied with basic CTB Distributed By: GMW Associates 955 Industrial Road, San Carlos, CA, 94070 USA PHONE: +1 650-802-8292 FAX: +1 650-802-8298 EMAIL: sales@gmw.com WEB: www.gmw.com CONTACT US For further details of this or any other product from PPM, please contact us at: PPM Ltd, 65 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire, SN6 8TY, UK. Email: sales@ppm.co.uk, Tel.: +44 (0)1793 784389 Fax: +44 (0)1793 784391 Web: www.vialite.co.uk or www.ppm.co.uk F-xxx-DS-1 Fibre Optic Cable solutions Datasheet Page 6 of 6 Issue 1 CR 1943