FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Similar documents
3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Medium Box for Cable Termination

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

GCO2-BC6/16-MC-XV GCO2-BD6/16-MC-XV GCO2-BE6/16-MC-XV. 3.1 Installation of the workstand 3.2 Opening the FIST-GCO2

Gel-sealed in-line fiber optic closure

FOSC-450 Product Range Ordering Guide

FOSC 450 C6 and D6 Closures

3A TC 699/SIP/UK/12

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

Ordering Guide. for FIST-GCO2 product range

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

3M Distribution Box (DDB)

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

Optical Distribution Box 300 Installation Guide. Version : R0.0

HCS - HES Cabling Systems

SLiC Fiber Aerial Closure System

Ordering Guide. for FIST-GSS2 product range

Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

INSTALLATION INSTRUCTIONS

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Seal Kits for BUDI Enclosures

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FACT Cable Termination Unit

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

2178-L/S Series Fiber Optic Splice Case with Gasket

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

FOSC 400. Fiber Optic Splice Closure. Features

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

Fiber Optic Splice Closure GPJ Instruction Manual

27mm ECAM Double Cable Entry Port

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

18mm ECAM Cable Entry Port

3 SLiC Aerial Closure with Rubber End Seal

FOSC 400 C5 & D5 Fiber Optic Splice Closures

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Splice Closure Fiber (SCF) Family

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

TECHNICAL SPECIFICATION

FOSC 400. Fiber Optic Splice Closures

3M Fiber Closures BPEO

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Instruction manual. Midi Fiber Dome. Instruction manual

FOSC 400 A4 Fiber Optic Splice Closure

Customer-Owned Outside Plant

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

IP-LINX. Installation Guide

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Coupling Tray FDTC-10S-COUPLINGTRAY

Water blocking tape. Locator ridge HPA-0486

Instructions. Cable with Armor F CAUTION. October Rev A

2178 L/S Series Fiber Optic Splice Cases and Accessories

SPECIFICATION. Spec No : VSS-1402-CS603B

IP-LINX Fiber :: X-XXXX

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

3M Better Buried Closures

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Crimp & Cleave Termination Instructions for SEL ST Connectors

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

3M Better Buried Compound Compression Closure System

DOME OPTIC SPLICE CLOSURE

3M Fiber Optic Closure System LL

LGX Compatible (LSX) Connector Module) User Manual)

Aerospace Fiber Optics

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

FOSC 400 A4. Fiber Optic Splice Closure. 1. General Product Information I N S T A L L A T I O N I N S T R U C T I O N S

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

RetractaNet XS. Extractable Solutions for OSP. October 2012

Coyote popup display set up instructions

Fiber Optic Closure. Fiber Optic Splice Closure For Aerial Line. Model : W-ICL-007-xxF. Features

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

3. Electronics and MMU2 unit assembly

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

OCT 15 Rev B

INSTALLATION INSTRUCTIONS MO023A

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

Transcription:

FIST-GCOG2 I N S T A L L A T I O N I N S T R U C T I O N TC-986-IP Rev A, Mar 2017 www.commscope.com FIST-GCOG2-Dx6 Content 1 Introduction 2 General 2.1 Abbreviations 2.2 Kit contents 2.3 Tools 2.4 Accessories 3 Installation 3.1 Opening the FIST-GCOG2 3.2 Installation of the cable attachment plate holder 3.3 Cable entrance positions 3.4 Looped cable preparation 3.5 Drop cable preparation 3.6 Cable termination 3.7 Installation of the gel block 3.8 Uncut loose tube storage and loose tube preparation 3.9 Fiber routing and fiber storage on trays 3.10 Tray identification and tube holder capacity 3.11 Cable grounding 3.12 Closing the closure 3.13 Important steps 3.14 Re-arrangement 1 Introduction The FIST-GCOG2 is the environmentally sealed enclosure for the fiber management system that provides the functions of splicing and passive components integration in the external network. The product can be tailored to almost any required configuration by adding splicing and/or passive device sub-assemblies. The FIST-GCOG2 has provision for all cable termination and sealing requirements. The closure is a single-ended design made of a thermoplastic material. The base and dome are sealed with a clamp and an O-ring system. For cable sealing, a wrap-around block with 6 ports is used which contains a pre-installed gel profile. One can terminate 6 cables with a diameter of minimum 9 mm and maximum 25 mm. It can be opened and closed repeatedly without the need to replace the gel. Uncut loose buffer tube storage is available between or on the UMS profiles. Follow all local safety regulations related to optical fiber plant elements. For cleaning FIST components the use of isopropylalcohol is recommended. 2 General 2.1 Abbreviations Universal Mounting System Universal Cable Termination UMS UCT

2.2 Kit contents 3 Installation 3.1 Opening the FIST-GCOG2 Lever Dome Base Cable attachment plate with UMS profiles and routing blocks Gel block with trigger Clamp O-ring 2 Cable retention devices 4 Plugs for unused ports 2 Strength member fixation devices Silicagel 2 Tray covers Tray wedge Plastic bags to store uncut loose buffer tubes Installation instructions Cross reinforcement blocks Clamp 3.1.1 Open and remove the clamp 3.1.2 Remove the dome and the O-ring. Remark: take care with the O-ring and the sealing surfaces on the base and dome (avoid damaging). Clean only with clear water or with the supplied cleaning tissue if needed. 2.3 Tools FACC-STRIPPER-02 FIST-GCOG-CAPH FIST- GCOG-L-BRACKET FIST- GCOG-CCLAMP Tie wrap fixation tool To strip loose tubes Cable attachment plate holder (table mounted) L-bracket for attaching pole/wall mounting to table 3 screw clamps To tighten tie wraps 2.4 Accessories FIST-GCOG-MOBRA FIST-GCOG-POLE-KIT FIST-GCOG-WALL-KIT FIST-GCOG -CA FIST- GCOG-MULTI-4 Mounting bracket Pole mounting set Wall mounting set Cable retention device Cable entrance kit for up to 4 internal cables 3.1.3 Loosen the securing screws of the cable attachment plate and take out the cable attachment plate with the pre-installed UMS. 2

3.2 Installation of the cable attachment plate holder 3.4.1 Prepare the needed window cut (see table). 3.4.2 S-cable: Mark the cable in the middle and at 1.75, 1.85 or 1.95 m left and right of the first mark. Remove the cable jacket between the outer marks. A B 3.2.1 Install the cable attachment plate holder (FIST-GCOG-CAPH) to the cable attachment plate and use the clamp to mount it on a table. 3.3 Cable entrance positions 2 6 4 5 3 1 3.4.3 Reversed oscillating cable: Mark the cable in the middle of the loop and remove the cable jacket left and right of the mark over a total length of 1.1 m (a little more as the distance between two reversal points on the cable). Locate the buffer tube reversal point on the cable and mark the cable at 1.75, 1.85 or 1.95 m left and right from this point. Remove the rest of the cable jacket between the outer marks. Important: make sure that the twist position of the loose tubes is identical in A and B. This must be done correctly for the ease of installation. 3.3.1 Install the looped (main) cable in port 1 and 2. Loops are stored in between the UMS s. In case more than X tubes: put the uncut loop at one side and fix the plastic bag with the tubes on the UMSprofiles with tie-wraps. FIST-GCOG2-DC FIST-GCOG2-DD FIST-GCOG2-DE X 8 10 12 (X = maximum # of loose tubes [D=3.1 mm] to be stored between the UMS s) 3.3.2 Drop cables can be installed in all the remaining ports. 3.4 Looped cable preparation 3.4.4 Cut the strength member at 90 mm from the cable jacket. If a shield is present, leave 15mm of the shield. In case of shielding, make sure that it is positioned on the outside of the cable (for maximum routing space of the loose tubes). FIST-GCOG2-DC FIST-GCOG2-DD FIST-GCOG2-DE 3.4.5 Clean the loose tubes and remove all the grease. Window cut 3.50 3.70 3.90 Length (m) 3.4.6 Identify the loose tubes with the split collet rings if necessary. There are different split collet rings depending on the diameter of the loose tube. 3

3.5 Drop cable preparation 3.5.1. Remove the outer jacket over a length of 2 meter. 3.5.2 Cut the strength member at 90 mm from the cable jacket. If a shield is present, leave 15mm of the shield. In case of shielding, make sure that it is positioned on the outside of the cable (for maximum routing space of the loose tubes). 3.5.3 Clean the loose tubes and remove all the grease. 3.5.4 Identify the loose tubes with the split collet rings if necessary. There are different split collet rings depending on the diameter of the loose tube. 3.6 Cable termination 3.6.3 Heat the cable jacket and position the cable retention device 5 mm behind the cable jacket end. Push the cover in the cable retention device and make sure that the teeth of the device and the cover are pressed in the cable jacket. Tighten the tie wraps (with the tie wrap tool). 3.6.1 Guide the cable without torsion to the desired port and mark the cable. This line is used to position the cable retention device. See next steps. 3.6.4 Slide the base over the cables and position the cable retention devices in the cable attachment plate. 3.6.2 Install the tie wraps in the cable retention device as shown on the drawing. 4

3.7 Installation of the gel block 3.7.3 Slide and position the base over the gel block and tighten the securing screws of the cable attachment plate. 3.7.1 Remove the protection of the gel block and open the gel block. Position the open gel block in between the cables. Leave ± 2 cm between the gel block and the cable attachment plate. 3.7.4 Tighten the trigger until it butts. When necessary, use wrench (n 12) to tighten the trigger. 3.7.2 Before closing the gel block make sure it is clean. Insert the plugs in the unused ports. Remark: When installing the plugs make sure not to bend the crowns in the gel block. 5

3.7.5 Mark base and cable (see picture). Note: these lines on base and cable must always match when the closure is moved. 3.7.8 Remove the cable attachment plate holder and place the base in the pole/wall mounting bracket for ease of working. Tighten all the securing screws of the cable attachment plate. 3.8 Uncut loose tube storage and loose tube preparation 3.7.6 Mount the UCT (strength member fixation) on the strength member (if needed cut the strength member to length). Fix the eyelet on the closure bracket. 3.7.7 Install the cross reinforcement blocks into the unused ports. 6

3.8.2 In case more than X tubes have to be stored on the empty UMS side. 3.8.1 Remove the plastic parts at the top and the sides of the UMS profiles. Make some loops with the uncut loose tubes and put these in the plastic bag (be careful not to damage the loose tubes!). Two sizes of bags are available. Use the correct size according to the volume of the loose tubes. If needed use two bags. Slide the bag between the UMS as shown. Close the UMS. Remark: Loose tubes routed up to the tube holder should be routed in such a way that one still has complete access to the stored tubes between the UMS profiles. This is needed for later routing of loose tubes from the loops to the tube holders, without creating crossings and without creating disturbances on the loose tubes already routed up to the tube holders. 7

3.8.4 Clean and degrease the fibers and wind some PTFE tape around the transition from tube to fibers for protection. 3.8.5 In case of S-cable: cut the loose tube(s) (with fibers to be spliced) in the middle of the loop. Separate the cut loose tube(s) from the others. Match the loose tube(s) on the tubeholder and mark both sides. Strip the loose tube(s) between the marks. Clean and degrease the fibers. Separate the fibers up to the tube holder and route to single circuit or single element tray(s). 1 Position the tube on the lowest tubeholder retainer. Slide a tubeholder retainer until it snaps above the tube. 2 Remove the lowest tubeholder retainer. Use a tweezer if necessary. 3 Slide this tubeholder retainer in the lowest possible groove, above the (two or more) tubes. 4 Remove the top tubeholder. 3.8.6 Different loops can be put together beneath the same tube holder retainer. Position one or more loose tubes in the tubeholder and slide the tube holder retainer with the snap forward in the lowest possible grooves of the tubeholder above the loose tube(s). The tube holder retainer must snap. 3.8.3 In case of reversed oscillating cable: separate the loose tube(s). Match the loose tube(s) on the tubeholder and mark both sides between the two marks. Shave between the two marks with the appropriate tooling. 3.8.7 If the fibers are twist free one can route the fibers separately to single circuit trays or single element trays. Separate all the fiber loops first up to the tubeholder. If the fibers are not twist free select first the fiber(s) which have to be spliced and cut these fibers in the middle of the loop. Remove these from the bundle up to the tubeholder. These fibers can be routed to single circuit trays, the other uncut fibers will be routed to a single element tray (never in dark fiber storage, see fiber routing). 8

3.9 Fiber routing and fiber storage on trays 3.9.3 Fix the wraparound groove plate on the UMS by putting the plate with the long protrusions in the S1 UMS-profile and sliding the plate in the S2 UMS-profile until it snaps. (Do not leave gaps between groove plates). 3.9.1 Fibers can be routed between As1, As2, Bs1 and Bs2. In case fibers have to be routed from side A to side B, use the window. Select the cable termination in such a way that a minimum of fibers will cross and have to be routed through the window. Therefore the selection of ports according to the cable lay-out is important. Ports 1, 5 for cables to As2 Ports 2, 6 for cables to As1 Ports 1, 3 for cables to Bs2 Ports 2, 4 for cables to Bs1 Verify the position of two cables if they are placed on the same side, because the total number of loose tubes can never exceed the capacity of the tube holder. 3.9.4 To remove push the two snapfits at S2 UMS-profile and slide the wraparound plate towards the S1 UMS-profile. 3.9.2 Remove the hook and loop fastener and routing block cap. To remove the routing block cap lift the two snaps at one side of the routing block cap. 9

3.9.6 To remove the tray put the fiber guiding pin between the lip on the wraparound groove plate and the tray, and move laterally towards S1. 3.9.5 Place a tray in the wraparound groove plate: do this by pushing the lip on the groove plate slightly up with the tray and move the tray laterally into the hinge cavities. Start from the FAS block side and preferably mount trays as you fiber up. In case of SC trays do not leave spaces. In case of SE trays always leave one hinge facility open (between that FAS block and tray or tray and tray). 3.9.7 Identify the tray to be worked on and make it accessible. If the routing block and trays are in vertical position, you will have to support the trays above the selected one using the tray wedge which fits in the holes of the wraparound groove plate. Position the wedge carefully such that the groove is still accessible for the fibers and be careful not to push the wedge against fibers. To remove the wedge,use two hands to pull on both ends (near the groove plate) at the same time. 10

3.9.8 Route the fiber in the correct groove of the wraparound groove plate to the entrance of the identified tray. Fiber must be routed in the groove behind the hinge of the tray! 3.9.12 ANT in SE tray. 3.9.9 Pull gently on the fibers in the tray and make sure that the fibers are well contained in the routing block and wraparound groove plate. 3.9.13 RECORDsplice/ANT in SC tray. 3.9.14 Ribbon 4/8 tray. 3.9.10 Store the fibers temporarily on a tray (the picture shows the case of a loopback). 3.9.11 Storing dark fibers can be done in different ways: 1) Organise dark fibers into the different trays, following instructions as described. 2) Organise dark fibers together into the first available tray (i.e. with a max. of 24 cut or 12 loops primary coated fibers in one SE-tray). 11

Overview loose tubes FOPT tube 1,8 mm (3 retainers) 4x30 = 120 tubes FOPT tube 3,1 mm (3 retainers) 4x9 = 36 tubes FOPT tube 4,3 mm (1 retainer) 4x6 = 24 tubes FOPT tube 5,0 mm (1 retainer) (2x3) + (2x4) = 14 tubes 3.9.15 Ribbon 12 tray. Overview spiral tubes 3.10 Tray identification and tube capacity Spiral tube 5,0 mm (1 retainer) (2x3) + (2x4) = 14 tubes Spiral tube 6,4 mm (1 retainer) 4x2 = 8 tubes Spiral tube 8,8 mm (1 retainer) 4x1 = 4 tubes 3.10.2 Tube holder capacity Number x outer diameter loose tube (mm) 3.11 Cable grounding 3.10.1 One can use a permanent marker pen to write on the tray. Overview loose tubes Loose tube 1,5 mm (3 retainers) 4x30 = 120 tubes Loose tube 2,3 mm (3 retainers) 4x12 = 48 tubes 3.11.1 In case of grounding, mount the grounding wire on the grounding bolt. 12

3.12 Closing the closure 3.12.1 Place the O-ring back on a clean base! Remove the silica-gel from the bag and place it in the closure. 3.12.3 Install the dome and close it with the clamp. 3.12.2 Make sure the two foam blocks are on top of the UMS profiles. Note: the foam blocks have a functional purpose. 13

3.13 Important steps during installations Make sure that the grooves on the wraparound groove plates are clean. Clean the fibers. Loose tubes routed up to the tube holder should be routed in such a way that one still has complete access to the stored tubes between the UMS profiles.this is needed for later routing of loose tubes from the loops to the tube holders without creating crossings and without creating disturbances on the loose tubes already routed up to the tube holders. Use correct lengths in the tubeholder. Make sure not to loose ID. Be secure when preparing window cuts on loose tube cables for storing uncut fibers. Avoid in all cases crossings of fibers and loose tubes. Replace the silica gel after each re-entry. Do not mount the closures with the base pointing up. 3.14 Re-arrangement Avoid to pull fibers in between groove plates. Avoid fiber movement between the tubeholder and first containment lips on the routing block. Take special care re-arranging fibers from side A to B or reverse. If accidentally active fibers are removed from the containment devices, reposition them carefully. 14

15

To find out more about CommScope products, visit us on the web at www.commscope.com For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/supportcenter 2017 CommScope, Inc. All rights reserved. FIST, SMOUV and all trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. This product is covered by one ore more U.S. patents or their foreign equivalents. For patents, see: www.commscope.com/productpatent/productpatent.aspx.