Setup Guide. Quantum Data 70x/80x Series. Video Generators. Rev. 1.1

Similar documents
Setup Guide. Murideo SIX-G. Digital Video Generator. Rev. 1.6

Setup Guide. Dolby PRM Rev. 1.1

Setup Guide. Panasonic VX200/VX300/BT300. Plasma Displays. Rev. 1.1

Setup Guide. Panasonic BT-4LH310. Rev. 1.1

Setup Guide. Flanders Scientific BoxIO. Rev. 1.1

Setup Guide. AJA Video Systems LUT-box. Rev. 1.2

Setup Guide. Konvision monitors. Rev. 1.0

Setup Guide. Pandora Pluto. Color Management System. Rev. 1.1

Setup Guide. Creating 3D LUTs. CalMAN Overview. Rev. 1.1

Setup Guide. X-Rite i1display. Retail and OEM. Rev. 1.2

Setup Guide. Blackmagic Design HDLink Pro. Rev. 1.1

Setup Guide. Teradek COLR. Rev. 1.1

Setup Guide. Panasonic. VT30/DT30/D30, VT50/WT50 (US/NA models) Rev. 1.1

Setup Guide. SpectraCal ColorBox. (also eecolor) Image Calibration Processor. Rev. 1.1

Setup Guide. Blackmagic Design Teranex Mini. Rev. 1.3

Setup Guide. Panasonic. VT60/ZT60/WT60/DT60, WT600 (US/Canada) VT60/ZT60/GT60/WT60/DT60/FT60, VT65, WT600 (EU) VT60/WT60/DT60 (NZ/Asia) Rev. 1.

Setup Guide. Panasonic. VT30/GT30/DT30, VT50/GT50/WT50/DT50 (EU/UK models) Rev. 1.1

Setup Guide. AV Foundry VideoForge HDMI. Digital Video Generator. Rev. 1.1

2018 Quick Reference Guide

Setup Guide. SpectraCal MobileForge. Pattern Generator App. Rev. 1.6

Setup Guide. EIZO Monitors. Rev. 1.4

Setup Guide. Panasonic AS800/AX800/AX Models. Rev. 1.1

Setup Guide. SpectraCal C6 HDR2000 Colorimeter. Rev. 1.2

Setup Guide. CalMAN ColorMatch. Rev. 1.1

Setup Guide. Klein K-10CP Colorimeter. Rev. 1.1

Setup Guide. Color Volume Analysis Workflow. Rev. 1.2

2018 Quick Reference Guide

Setup Guide. CalMAN Client for SCRATCH. Rev. 1.1

Setup Guide. Rev. 1.7

AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide

User Manual. Rev. 1.3

So, how do I create LUTs for each one of the buttons on the remote?

Using LightSpace CMS for User Created Calibration LUTs

Calibration Using i1 probe with CalMan and Resolve

Achieve Accurate Critical Display Performance With Professional and Consumer Level Displays

What is the history and background of the auto cal feature?

Calibration Best Practices

Achieve Accurate Color-Critical Performance With Affordable Monitors

Palette Master Color Management Software

More Skills 14 Watch TV in Windows Media Center

GWL/ Power Group Technology Solutions Stay Powered for the Future

FSI Calibration Guide Using I1 / LightSpace / Resolve

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0) on the disk sent with the printer. Follow the steps (see the picture):

3G-SDI to HDMI Scaler Installation Guide

SXGA096 DESIGN REFERENCE BOARD

FSI Calibration Guide Using CR100 / LightSpace / BoxIO

Yellow Frog. Manual Version 1.1

RF Solution for LED Display Screen

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Instruction Manual. 1 Page

HDMI to 3G-SDI Scaler Installation Guide

USER MANUAL. 840Hxl Pattern Generator MODEL: P/N: Rev 7

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

User Manual January,

USER MANUAL. 840Hxl Pattern Generator MODEL: P/N: Rev 5

In-situ Port Cal for Dual Carriages Tuner

PLASMA MONITOR (PT20 UVVis) USER GUIDE

Interface sheet - Edan ST-1212 Stress - CPET ergometer

Ydea-C5 System. Automatic Brightness Adjustment_DMX User Manual

Connecting To and Programming the LPC2148 Blue Board. Method 1 ISP (In-System Programming) w/ Flash Magic

R4 AIS Class B Transponder

High Power Bundle for the Icom IC-7300

Instruction for Locking Tuner s Carriage(s) before Shipping

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

Auxiliary states devices

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Table of Contents CHAPTER 1: INTRODUCTION: THE BASICS...6

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

ASKING FOR ASSISTANCE

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

Agilent CSA Spectrum Analyzer N1996A

Kaleidescape Co-Star for Lumagen

HITS QT/QT+ Setup Instructions for QSD/QHD Services using: Drake SCT2x4 Headend Transcoder 2 Satellites/4 Multiplexes

Portland Trail Blazers: CalMAN Display Calibration Case Study

SpectraCal C6-HDR Technical Paper

TransitHound Cellphone Detector User Manual Version 1.3

Installer Guide. Follow these instructions to set up the PowerLite Pro Cinema 1080 projector and HQV video processor.

Mortara X-Scribe Tango+ Interface Notes

OptoFidelity Video Multimeter User Manual Version 2017Q1.0

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

1 Synchronising Xsens with the Delsys Trigno EMG System

$99 $199 $299 $399 $199 $295 $695 $1,595 $1,495 $2,495 $2,995

Quick Guide Book of Sending and receiving card

User s Guide. Version

MX194. Your advantages. 1MP Medical-Display

Transmitter Interface Program

Install and Set Up G550 Hardware

Extra long-range RFID (proximity) card reader

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

AVIA Professional A multi-disc calibration, set-up and test suite Developed by: Ovation Multimedia, Inc. July, 2003

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Lite USER GUIDE. 3 Lite. For more information visit

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

4x1 VGA & Audio Switch with IR

Portable VGA & USB Audio to HDMI Converter Installation Guide

Transcription:

Setup Guide Quantum Data 70x/80x Series Video Generators Rev. 1.1

Introduction CalMAN Required Version The Quantum Data 70x and 80x Video Generator test patterns can be automatically controlled by CalMAN Display Calibration Software. The generators provide test patterns for visual performance evaluation, grayscale luminance ramp calibration, color gamut (CMS) calibration, and validation measurements of white, primary, and secondary luminance ramps. These generators do not provide RGB triplet support. These generators cannot provide test patterns for saturation sweeps, ColorChecker patterns, or 3D LUT calibration. Note: The QD 804B controls its window pattern size and the luminance/color of the window, but does not control the background of the window pattern. When you select APL patterns or the Window 4-40 pattern with the 804B, it produces a constant black background instead of the expected background. Version 5.6.0 or later Version 5.6.1 adds HDR10 support for QD 804 pattern generator (no 804b HDR10 support at this time) CalMAN Recommended Workflows All measurement and calibration workflows except ColorMatch and Color Cube. Quantum Data Generator Required Firmware All firmware versions are acceptable QD 804 requires firmware version 15092260 or higher to support HDR10 patterns Quantum Data Generator Control Port RS-232 Serial Quantum Data Generator Computer Connection Connect the Quantum Data generator to the computer with a null modem serial cable and, if necessary, a USB to serial converter. 2

If a USB to serial converter is used, be sure that the proper USB driver is installed for the converter. If necessary, install the SpectraCal Device Driver Pack from this link: http://www.spectracal.com/download.php?id=3 Note: See the following guide on USB to Serial Converters. http://www.spectracal.com/documents/qsgs/ftdi_usb_to_serial_set upguide.pdf 3

CalMAN Connection Procedure CalMAN Source Connect 1. On the CalMAN Source Settings tab, click Find Source. 2. On the Find Source dialog (Figure 1), select Quantum Data as the Manufacturer. 3. Select the Model to match your Quantum Data generator. 4. Select the Com Port that is assigned to the connected generator (check this in Windows Device Manager). CalMAN Source Settings Tab Figure 1. CalMAN Find Source dialog, for connecting to the Quantum Data generator as a CalMAN test pattern source. 5. Click Connect on the Find Source dialog. The CalMAN Source Settings tab (Figure 2) provides Source Information and Settings for the connected Quantum Data Video Generator. 4

Figure 2. CalMAN Source Settings tab, for selecting generator setup options. Settings Window Size Select the desired test pattern size and type from the Window Size selection box. Note: For Plasma and CRT displays, Constant APL 50 works well. Delay CalMAN provides a default measurement delay time of 2 seconds to accommodate the test pattern settling time of the Quantum Data generator and an attached display. To optimize the delay time for a particular configuration, potentially speeding up all measurement times, click the Optimize button. Specialty Patterns The pattern selection field allows you to manually select patterns from the Quantum Data generator for visual display evaluation (not for automated measurements or calibration). 5

About / Contact About Portrait Displays Portrait Displays, Inc., since 1993, is a leading application software provider (ASP) for PC, smartphone, and tablet displays. The Portrait Displays team now includes SpectraCal, the world s leading provider of video display calibration software. The combined companies offer value-added, feature-rich solutions to both OEM display manufacturers and end users seeking improved accuracy and manageability of their displays. Portrait Displays, an Intel Capital Portfolio company, is a private corporation with headquarters in Pleasanton, California, USA with representatives in Europe, Taiwan, China, Japan, and Korea. Contact Us Submit a Technical Support Request: http://calman.spectracal.com/techsupport.html spectracal.com sales@spectracal.com +1-925-227-2700 Portrait Displays, Inc. 6663 Owens Drive Pleasanton, CA 94588 USA portrait.com 6