Product Identification

Similar documents
OPERATING INSTRUCTIONS. Hand-Washing Timer 740-T2HW ELECTRICAL TABLE OF CONTENTS

OPERATING INSTRUCTIONS. Baked Potato Timer 740-T2B ELECTRICAL TABLE OF CONTENTS

OPERATING INSTRUCTIONS. Single Function Timers Model No. 740-T, 740-TJ & 740-TSeries ELECTRICAL TABLE OF CONTENTS

Product Identification. 247SL Series

OPERATING INSTRUCTIONS. Multi-Function Computers Model No. 840-C, 840-CJ & 840-CF Series ELECTRICAL TABLE OF CONTENTS

Sprite TL Quick Start Guide

VK-P10SE WARRANTY REGISTRATION FORM

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Operation Manual VMS 3.0 Video System

blink USER GUIDE Bluetooth capable Reclocker Wyred 4 Sound. All rights reserved. v1.0

LED Programmable Interval Timer Owner's Handbook

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide


Installation And Programming Guide

HD Digital Set-Top Box Quick Start Guide

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

Installation And Programming Guide

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Viztrac AM200 User s Guide. Page 1 of 12

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

TimeView Display. Operating Manual

Introduction. Package Contents. Installation Requirements

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

Distribution Unit. User Guide

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

APSPB PUSH BUTTON ZERO Installation Manual

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

Watch and Learn Visit upunch.com/resources to view our helpful videos. Or scan this QR Code to get our step-by-step videos right on your phone.

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Tube Rotator. User Guide. Version 1.2

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

AWT150C/AWT150CS/ AWT151C CCD Camera

Advanced Digital Melting Point Apparatus

Tube Roller Shakers. User Guide. Version 1.2

Access Control Keypad for MK-DV, JB-DV

Installation & Programming Manual. Please read before using this timer.

Master Time Clock MTC Users Manual

Manual No: Revision: D. IQ Box. Software Upgrade Instructions

By CHANNEL VISION. Flush Mount Amplifier A0350

User Manual. Model 1365 Video Scaler

UC1000 Universal Controller

Information. Marketing Description. For Models: DA2133i. 2113i. User s Guide Rev B

MARCO CORNER, 19/ THIENE (VI) ITALIA

Sample BD Tech Concepts LLC

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Evolution Digital HD Set-Top Box Important Safety Instructions

Kramer Electronics, Ltd.

Picture Fan. display your photos, graphics & messages

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

M1020 Programmable Limit Switch (PLS)

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

User Instructions. 16 SCB Sync Station.

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

User Manual. Model 1351 DVI Repeater with HDCP

HP6E Operating Manual. August 2012

Home Kit. Model XM101HK

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

KODAK Video Monitor CFH-V10

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Single Station Waterproof Timer

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

RemotePoint. Navigator. User s Manual VP4150

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

HawkEye 1500 Series Quick Start Guide V2.4.1, Nov 2008

LIGHT COPILOT II. elationlighting.com Internet:

Warnings and Precautions

1080P. Wireless for HDMI. In-Room Solution. GTV-WHD-1080P-SR User Manual. gefentv.com

USER MANUAL Model: A5

MANUAL ENGLISH Core Club Ordercode: D2314

Preset 10 Ethernet Interface Configuration & Owner s Manual

Quintet SL. Owner s Manual

PIXEL BAR 40. user manual 1.0. ELATION PIXEL BAR 40 user manual 1.0

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

Disclaimer. Trademarks. Copyright. Contact Us Control4 Corporation S. Election Road Salt Lake City, UT USA

Kramer Electronics, Ltd. USER MANUAL. Model: 6809HD. HD/SD-SDI AES Embedder

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

Tension Electric Screen. CineTension Series. Users Guide USER S GUIDE. Rev. 1.1

Kramer Electronics, Ltd.

ZVOX AccuVoice TV Speaker MODEL AV150.

FiliBuster. User Manual

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Chore-Tronics 2 Breeder Edition Override Box

VITEK VTM-TLM191 VTM-TLM240

AS Telecommunication Watch Dog. Version 2.70

KOP4800 Owner s Manual

LED Pixel Track V3 ORDERCODE 42200

NT-9600 Wireless Barcode Scanner. Introduction

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200N5. 1:2 High Resolution UXGA DA

Protect Your Hearing!

Z100 / Z300 Z500 Z700 OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW ELLIPTICAL!

Introduction. Trademarks Used

RG NDT INTERNATIONAL INC

Wireless VGA Extender LR. GTV-WVGA-LR. User Manual

Transcription:

Operation Manual Multi-display 10-Channel and 16-Channel Timers Product Identification The Prince Castle Model 755 Series Multi-display 10-Channel Timer and 16-Channel Timer are easy-to-use timers that count down in minutes and seconds, or hours and minutes. Each channel has its own display and can be programmed independently. Slide in replaceable menu strips identify the product being timed on each channel, and are replaceable as restaurant menus change. Both auditory and visual signals are used to alert busy staff people when a function is complete. LIMITED WARRANTY This product is warranted to be free from defects in material and/or workmanship for a period of 1 year from date of original installation, not to exceed 18 months from the date of manufacture. Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts and labor. This equipment is portable; charges for on-location service (e.g., trip charges, mileage) are not included in the provisions of this warranty. This warranty is subject to the following exceptions/conditions: Use of any non-genuine Prince Castle parts voids this warranty. All labor to be performed during regular work hours. Overtime premium (the incremental amount) will be charged to the customer. Damage caused by carelessness, neglect and/or abuse (e.g., dropping, tampering or altering parts, equipment damaged in shipment, by fire, flood or an act of God) is not covered under this warranty. All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage is the customer s responsibility. This equipment must be serviced by Prince Castle Authorized Service Agency or a Prince Castle Service Technician during the warranty period. LIMITED WARRANTY (cont.) The power cord on this product is rated for a maximum surface temperature of 194 F (90 C ). If the cord comes into contact with the fryer or rethermalizer or any other heated surface, it may be damaged and/or cause damage to the product and/or injury to the user. The power cord may also be damaged if placed directly in the path of the high temperaresulting from any such misuse may result in a voided Warranty at the sole discretion of the manufacturer. TABLE OF CONTENTS Product Identification... 1 Safety Information... 1 Important... 1 Installation... 1 Cleaning... 1 Operation... 2... 2 Programming... 4 355 East Kehoe Blvd. Carol Stream, IL 60188 Phone: 630-462-8800 Toll Free: 1-800-PCASTLE Fax: 630-462-1460 www.princecastle.com Safety Information Important! WARNING: Indicates information important to the proper operation of the unit. Failure to observe may result in damage to the equipment and/or severe bodily injury or death. CAUTION: Indicates information important to the operation of the unit. Failure to observe may result in equipment damage. Prince Castle reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. Installation Remove the unit from the carton and inspect for signs of damage. If there is damage to the unit: Notify the freight carrier (e.g. UPS) within 24 hours, Save carton and packaging materials for inspection purposes, Contact your local dealer, or if purchased directly, the Prince Castle Sales Department at 1-800-722-7853 or 630-462-8800 to arrange for a replacement unit. NOTE: When installing this unit, the ambient temperature at the mounting site should not exceed 100 F (37.8 C). CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes. Plug the unit into an applicable electrical receptacle. Cleaning Use ONLY a clean damp cloth, wipe the face and other surfaces on the Model 755 Series Timer, as necessary. If desired, a mild soap may also be used. NEVER use chemicals and/or degreaser of any kind! Long term use of certain chemicals has a negative effect on the surface of the timer, making it brittle and easily damaged. 755-503revA

Operation or (Menu 1) (Menu 2) When a channel s timing cycle has been activated its individual display will show the timing countdown of that channel. If the time is in Hours-Minutes (H:M) the colon in the middle of the 4-digits will flash. If the time is in Minutes-Seconds (M:S) the colon in the middle of the 4-digits will be on continuously. At the conclusion of a timing cycle the display flashes 0. At the conclusion of a timing cycle the display will show either disc for discard or done for done. This indication is programmable. Each of the channels of the 10-Channel or 16-Channel timers operate in an identical manner. Press a channel button to activate a timing cycle (a short beep sounds). The timers can be programmed to count up to a selected value or count down to 0:00. NOTE: To cancel any operation in progress, press the related channel button three times in quick succession (less than three seconds). The channel LED turns off and the LED of the next channel with the lowest countdown remaining will blink. At the conclusion of a timing cycle the display will show either disc or done depending on how it is programmed. Two different timing cycles can be setup for each channel. These are called Menu 1 and Menu 2. To change from one menu to the other, all channels must be idle. Simultaneously press both the UP and DOWN buttons for 6 seconds. The display will change between the single-line display (Menu 1) and the three-line display (Menu 2). HM10 Menu 1 Channel 1 30:00 0:00:00 DISC Channel 2 30:00 0:00:00 DISC Channel 3 30:00 0:00:00 DISC Channel 4 30:00 0:00:00 DISC Channel 5 30:00 0:00:00 DISC Channel 6 30:00 0:00:00 DISC Channel 7 30:00 0:00:00 DISC Channel 8 30:00 0:00:00 DISC Channel 9 04:00 0:00:00 DISC Channel 10 04:00 0:00:00 DISC HM10 Menu 2 Channel 1 30:00 0:00:00 DISC Channel 2 30:00 0:00:00 DISC Channel 3 30:00 0:00:00 DISC Channel 4 30:00 0:00:00 DISC Channel 5 30:00 0:00:00 DISC Channel 6 30:00 0:00:00 DISC Channel 7 30:00 0:00:00 DISC Channel 8 30:00 0:00:00 DISC Channel 9 04:00 0:00:00 DISC Channel 10 04:00 0:00:00 DISC 2 755-503revA

Operation HM16 Menu 1 Channel 1 :00 0:00:00 DISC Channel 2 :00 0:00:00 DISC Channel 3 :00 0:00:00 DISC Channel 4 :00 0:00:00 DISC Channel 5 :00 0:00:00 DISC Channel 6 :00 0:00:00 DISC Channel 7 :00 0:00:00 DISC Channel 8 :00 0:00:00 DISC Channel 9 30:00 0:00:00 DISC Channel 10 30:00 0:00:00 DISC Channel 30:00 0:00:00 DISC Channel 12 30:00 0:00:00 DISC Channel 13 30:00 0:00:00 DISC Channel 14 30:00 0:00:00 DISC Channel 30:00 0:00:00 DISC Channel 16 30:00 0:00:00 DISC HM16 Menu 2 Channel 1 :00 0:00:00 DISC Channel 2 :00 0:00:00 DISC Channel 3 :00 0:00:00 DISC Channel 4 :00 0:00:00 DISC Channel 5 :00 0:00:00 DISC Channel 6 :00 0:00:00 DISC Channel 7 :00 0:00:00 DISC Channel 8 :00 0:00:00 DISC Channel 9 30:00 0:00:00 DISC Channel 10 30:00 0:00:00 DISC Channel 30:00 0:00:00 DISC Channel 12 30:00 0:00:00 DISC Channel 13 30:00 0:00:00 DISC Channel 14 30:00 0:00:00 DISC Channel 30:00 0:00:00 DISC Channel 16 30:00 0:00:00 DISC 755-503revA 3

Programming Timer Programming Countdown Mode To program the timer, all 10 or 16 timing channels must be idle with the display showing either one or three sets of four dashes and all LED s turned off. A single set of dashes is shown to program Menu 1 and three sets of dashes are shown to program Menu 2. NOTE: This mode can only be entered when all channels are idle. Enter the Countdown Mode by holding the UP button for 6 seconds. This will determine if all the timing cycles count up from 0:00 or count down to 0:00. Use the UP or DOWN buttons to toggle between count up or count down. Display 1 will indictor C-uP or C-dn. When the desired mode is obtained, momentarily press any channel button to save it and return to Timing Mode. NOTE: To return to Timing Mode without saving, momentarily press the Prince Castle logo button. Entering Program Mode Press and hold the Prince Castle logo button for 6-8 seconds to enter the Programming Mode. The display changes to Prog and all channel LED s turn red. 4 755-503revA

Programming Volume Level Selection Individual Channel Programming NOTE: This mode can only be entered when all channels are idle. Press and hold the DOWN button for 6 seconds to initiate the Volume Level Setup Mode. In this mode the timer s audio volume can be set to one of three different levels by using the UP and DOWN buttons. A display will sequence through SL-1, SL-2, SL-3. When the desired level is obtained, momentarily press any channel button to save the setting and return to the Timing Mode. NOTE: To return to Timing Mode without saving, momentarily press the Prince Castle logo button. NOTE: This mode can only be entered when all channels are idle. Pressing and holding the Prince Castle logo button for 6 seconds will transfer the unit into Channel Parameter Programming Mode. When programming mode is first entered, the displays will show Prog until a channel is selected. Momentarily pressing a channel s button enables the parameterprogramming mode for that channel. After a channel has been selected, its associated display will show and its timing cycle value, end of cycle label information and action alarm time information will be displayed above or below it. Restoring Factory Presets Simultaneously pressing both the UP button, DOWN button and the Prince Castle logo button during the first 6 seconds after applying power to the timer will reset all channels back to their factory default settings. While in Channel Parameter Programming Mode, pressing the channel button next to a parameter (timing value, end-of-cycle label or action alarm time) enables the programming of that parameter for the selected channel. Use the UP and DOWN buttons to modify the value of the enabled parameter. When either the timing cycle value or action alarm time value are programmed, pressing the UP button will increment the value and pressing the DOWN button will decrement the value. Each time the UP or DOWN button is pressed the timing value increments or decrements by one count. NOTE: If either button is pressed and held, the timing value begins to increment or decrement automatically with the change rate increasing the longer the button is held. When the parameters for the selected channel are set, pressing the Prince Castle logo button will exit the channel s Parameter Programming Mode and return the unit to a state where another channel can be selected for programming. When parameter changes for all channels have been completed, press the Prince Castle logo button to exit Programming Mode and return the unit to an operationally ready, idle state. 755-503revA 5

Exploded View 8 88-591 INLET 85-7-02S POWER SUPPLY 9 5 755-013S MOUNTING BRACKET ASSY. 4 88-709-2-1 SPEAKER 5 5 3 2 740-497S HM16 740-498S HM10 MAIN BRD. 1 740-450S DISPLAY BRD. 740-662S HM16 740-664S HM10 MEMBRANE SWITCH ASSY. NOT SHOWN: POWER CORD #72-200- 6 755-503revA