Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Similar documents
SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Specification

Technical Specification Pavilion Dance

Technical Specification for the Alley Theatre, Strabane

DEREHAM MEMORIAL HALL

Stage. Get In & Parking

New Theatre Royal Lincoln Technical Information

Technical Specifications

TECHNICAL SPECIFICATIONS

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

The Haymarket Basingstoke Technical Specifications

INFORMATION FOR VISITING COMPANIES

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specifications Updated 01/10/2017. Stage

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Matt Dann Cultural Centre

Theatre Technical Specifications

2017 TECHNICAL SPECIFICATIONS

Theatre Technical Specification

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

CENTRE FOR PERFORMING ARTS

HIRE AND TECHNICAL INFORMATION

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Information

CHELSEA THEATRE. Technical Specifications

Technical Specifications Nov 2016

Technical Specification. Updated: April 2016

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Pleasance London Main House Visiting Company Information Pack May 2017

Cornerstone Technical Specifications 2018 / V1

Technical Director of Production Andrew Quick Ext 252

Main House Technical Specification

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Summary. Access and Parking

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specifications

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Technical Specification Ardhowen Theatre

UNIVERSITY CONCERT HALL. Technical Specification

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical specifications Main theatre. Sound

Visy Theatre technical information and general specifications 2019

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Access to back stage is off Fletcher St on the eastern side of the building

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Data Sheet

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Technical Specification

John Leslie Theatre. Technical Specifications. Updated July 2018

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

TECHNICAL SPECIFICATIONS

Latrobe Performing Arts Centre

JERWOOD VANBRUGH THEATRE

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Main House Technical Specifications

Monash Academy of Performing Arts

MONASH University Academy of Performing Arts

Technical Pack. Attenborough Arts Centre

The Anvil Technical Specifications

Technical Specifications

Monash University Academy of Performing Arts

Lighthouse Theatre Technical Specification

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Information for Incoming Companies

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

350 fixed seats with the capabilities of an additional 50 removable seats.

There are 10 dressing rooms in Theatre Kerkrade.

THE STREET THEATRE. Technical Specifications

Marjorie S. Deane Little Theater

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

SAINT ANSELM COLLEGE DANA CENTER

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

The Lights Technical Guide June 2017

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Services and Specification

Powerhouse Theatre technical information and general specifications 2017

Anvil Theatre. Technical Information

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

MAIN AUDITORIUM TECHNICAL INFORMATION

The set is very simple. It consists of one small box, a small stool, and a small ping- pong table.

Main Stage Technical Specs - Hall #2

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Yan Yean Theatre Technical Specifications

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Arcadia Performing Arts Center Technical Specifications and Information

Transcription:

Main House Technical Specification Get In Access for loading and unloading is via St Stephen s goods yard into the Hull Truck loading bay. Flat access at Stage Level for HGV s, backing directly onto main theatre stage rear dock, ramps available for smaller vehicles. Dock door is a 3m 70cm Width X 6m Height roller shutter with automated acoustic sliding door for direct access to stage. Lift available to Control Room level. Auditorium Raked seating on 3 sides of thrust stage. Maximum capacity = 429 Stage Thrust stage configuration with upstage shallow proscenium Stage is a modular system and can be set to various heights. Minimum height = flat to front row of auditorium. Maximum height = 700mm. Dimensions Full Width = 8m Depth upstage wall to DS edge = 9m 50cm Pros Width = 10m Depth upstage wall to pros = 4m Stage Left wing = 4m Depth X 3m 60cm Width Stage Right wing = 3m 10cm Depth X 6m 40cm Width Height to Grid from flat floor = 12m 55cm Pros height from flat floor = 6m Stage to underside of fly galleries from flat floor = 7m Flying System 4x Motorised LX winch bars Upstage of Pros with a 500Kg rating 8x 4-line manual Hemp-set Upstage of Pros with a 50Kg rating Please note that Hemp Bars should have the weight evenly distributed and are a 3 person lift so should not be used for live flying. All bars 11m length, 48mm barrel. Gridded height = 11m 20cm LX Bridges 5x LX Bridges above thrust stage DS of pros, to above auditorium seating. Height from flat floor to underside of bridges 1 3 = 7m 20cm Height from flat floor to underside of bridge 4 = 6m 70cm Height from flat floor to underside of bridge 5 = 6m Hard and soft masking available upon request.

Backstage Facilities Stage Kitchen Stage kitchen/prep area in Stage Left wing. Wardrobe Wardrobe facilities available including washing machines, dryers, hotbox, iron and ironing boards. Dressing Rooms Dressing Room 1 Located on the ground floor (stage level) 5 dressing tables with mirrors Toilet and Shower Dressing Room 2 Located on the ground floor (stage level) 5 dressing tables with mirrors Toilet and Shower Dressing Room 3 Located on the first floor (with lift and stair access) 5 dressing tables with mirrors Toilet and Shower Dressing Room 4 Located on the first floor (with lift and stair access) 7 dressing tables with mirrors 2 Toilets and Showers Green Room Large shared green room with filtered cold and boiling water. Oven, Hob, Grill, Refrigerator and Microwave oven. Show relay and video relay to both auditoria available. Wifi Available. SM Office Stage management office available for use as company office on request. Access to the internet available via provided computers. Internet is available in most areas of the theatre, including the auditoria. Please note: the stage management office and substage have poor signal. Power 63A Single Phase 32A Single Phase 63A Three Phase (3P+N+E) Located where Bridge 1 meets the fly floor Stage Left. Located in the workshop behind the back wall of the stage. There is cable access to the main stage, but this may have to be unplugged during the course of a run. Please note that we stock no 32 or 63A cables, converters or distros. If you wish to use either of these power supplies it is essential that you contact the venue well in advance of your arrival.

Stage Management Equipment SM Console with Cuelight System, Video Monitor & Paging (located in control room) 1 SM console available on stage at prompt positions on request but offers very poor view of stage. Wired Comms Channels 2(+3)* Wireless Comms Channels 1(+1)* Tecpro Wired Comms Packs (mixture of single and double channel) 12 HME DX Series Wireless Comms Packs 4(+4)** Video Relay Channels (not available in dressing rooms) 1 Backstage & FOH Paging from SM Desk and Stage Right Wing 1 * Extra wired comms channels must be negotiated before arrival. Wireless comms are connected to wired comms on one channel and feature an additional isolated wireless only channel. **A maximum of four wireless packs in full duplex mode (talk) at once. Extra packs must be negotiated before arrival. Lighting Equipment Circuits 3kw Dimmer Circuits (15amp socket) 196 5kw Dimmer Circuits (2 x 15amp socket & 1 x 32/1p amp socket per channel) 20 3kw Non-Dim Circuits (15amp socket) 28 Direct Mains Circuits (15amp socket. 32A max on whole ring) 14 Some circuits can be provided as a 6 channel Socapex on request. (depending on location) Fresnels & PC s Selecon 650W Acclaim Fresnel 10 Selecon 650W Acclaim PC 20 Selecon 1200W Rama 150 Fresnel (Standard) 24 Profiles ETC Source Four 19 Degree Fixed Beam Ellipsoidal 4 ETC Source Four 26 Degree Fixed Beam Ellipsoidal 13 ETC Source Four 36 Degree Fixed Beam Ellipsoidal 9 ETC Source Four 50 Degree Fixed Beam Ellipsoidal 6 ETC Source Four 15-30 Degree Zoom Ellipsoidal (New Optics) 7 ETC Source Four 15-30 Degree Zoom Ellipsoidal (Old Optics) 3 ETC Source Four 25-50 Degree Zoom Ellipsoidal (New Optics) 6

ETC Source Four 25-50 Degree Zoom Ellipsoidal (Old Optics) 8 Please note Zoom Profiles include a mix of 99 and 08 model lens tubes, the optics may differ significantly, old optics have a frosted focus to them. All Source Four Profiles are 750w model. Parcans (Various lamps/lenses available, please specify) Par 64 Long Nose Can (Black) 32 ETC Source Four Par 750w 4 Moving Head Fixtures Martin Mac 250 Krypton *ADDITIONAL HIRE COST MAY BE APPLICABLE* 2 Martin Mac 250+ *ADDITIONAL HIRE COST MAY BE APPLICABLE* 2 Strobes Available on request Lighting Console & Control ETC ION with 10 Fader Wing & 2 x 19 touch screens. 1 ETC 2 Port DMX Output Gateways (Standard positions: bridges, fly floor, SL & R wings) 4 Please note that we do not supply any colour. We operate a standard 2 universe set-up with universe one being completely consumed by generic dimming. If more than one spare universe of DMX is required, please contact the venue prior to arrival. Effects Smoke Machines Unique 2.1 Hazer 1 Jem Glaciator Low Fogger 1 Jem ZR-12 DMX Smoke Machine 2 Jem Techno Fog Smoke Machine (Non-DMX) 2 Please note that these items are shared with the Studio and will be supplied on a first come first served basis. Recharge costs may apply to the above items.

Sound Equipment Mixing Desks Soundcraft GB4 32 Channel Mixing Console (Live Mixing Position) Yamaha 01V96i Digital Mixing Console with ADAT Card & USB 16in/out. CH: 20 IN 10 OUT (Between DSM and LX op Position for SFX playback) Digico SD9 Digital Mixing Console with USB MADI 56in/out. CH: 48 mono/stereo IN / 24 mono/stereo flexi busses OUT (Live Mixing Position) Digico D-rack for use with SD9 Console. 32in/8out (One portable, one fixed in main house patch bay) 1 1 2 House System (see plan for exact locations) We operate a LCRS configuration of our house system. Options are available however to simply this to a simple LR. Please note, all side and delay fills are unable to be controlled separately to the rest of the system. Please contact the venue for more information and options. The following loudspeakers are part of the house system: EM Acoustics MSE-159 Flown Left & Right Prosc (left right for centre seating bank) 2 EM Acoustics 5 Piece HALO-C Array Flown Centre (centre fill for central seating bank) 1 EM Acoustics EMS 81 Fills (left and right seating bank fills) 2 EM Acoustics EMS 61 Delay Fills (rear of centre seating bank delay fills) 4 EM Acoustics EMS 118 Reflex Subwoofer (Floor standing moveable LF normally 2 positioned at or just behind prosc line) Other Available Amplifiers The following amplifiers are surplus to the house system amplifiers and are available for use to drive small/medium loudspeakers. QSC CX404 (4 x 250w RMS @ 8ohm) 2 T&M Performance SA600Pro (2 x 380w RMS @ 8ohm) Yamaha H5000 (2 x 550w RMS @ 8ohm) C-Audio RA3001 (2 x 400w RMS @ 8ohm) Other Available Loudspeakers EM Acoustics EMS 121 Full Range Loudspeaker (vertical flying brackets available) 7 EM Acoustics I-2 Spot/Fill Loudspeaker 6 EM Acoustics I-8 Compact Subwoofer 2008 4 Logic Systems LM12 Monitor Wedge Loudspeaker 4 ElectroVoice SX300 12 full range Loudspeaker (4 with horizontal flying brackets) 6 JBL Control One Spot Loudspeaker. ElectroVoice S40 Compact Monitor Loudspeaker 2

Effects & Processing Lexicon MPX1 Reverb Unit 1 Alesis Midiverb 4 Alesis Microverb 3 Behringer MDX 2400 Multicom Quad Dynamics Processor Compressors and Graphic EQ ( for use with analogue mixers) BSS FCS 966 Opal Dual Graphic EQ 3 Klark Teknik Square One 8Ch dynamics processor 1 Playback Mac Pro 5.1 with Qlab 3 Pro Bundle 16 channels in / 16 out (used in conjunction with Yamaha 01V96i mixer) 48 channels in / 48 out (used in conjunction with Digico SD9 Mixer) MD/CD players be available on request 1 Microphones Shure SM58 cardioid Vocal Microphone 4 Shure SM57 cardioid Microphone 4 AKG C1000 Microphone 4 AKG D112 Microphone 1 Sennheiser E604 Microphone 4 Sennheiser EW300 Series Radio Microphone Receivers with Beltpack Transmitters 8 Sennheiser SKM 300-835 Handheld Cardioid Microphone (to be used with above 4 receivers) Please note that radio microphones are shared with the Studio and will be supplied on a first come first served basis. RECHARGE COSTS MAY APPLY. Please check for available microphone heads. DI Boxes Available on request