DOP (dual output) encoder system

Similar documents
Installation guide M A

Installation guide M A

QUANTiC RKLC40-S incremental linear encoder system

QUANTiC RESM40 angle encoder system

Installation guide M D

Installation guide M A. VIONiC RESM20 / REST20 angle encoder system

TONiC T103x RTLC-S linear encoder system

TONiC T100x RGSZ linear encoder system

Installation guide M F RESOLUTE

Installation guide M C

TONiC T103x RTLC/FASTRACK linear encoder system

RESOLUTE absolute optical encoder with Panasonic serial communications

ATOM miniature encoder system

Installation guide M C. RESOLUTE RESA and REXA absolute angle encoders

ATOM miniature encoder system

LM10 linear magnetic encoder system

User guide M A. Advanced Diagnostic Tool ADTi-100 and ADT View software

E3/DS3 Fibre Extender

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Absolute Encoders Multiturn

ODW-621. RS-232 Point-to-point applications

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Installation guide H A. OMI-2H optical machine interface

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Fibre optic router for TP/FT-10 LRW-112PP

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

NI PXI/PXIe-2543 Specifications

Fibre Optic Modem ODW-622

Linear encoders without bearings incremental System for linear motion feedback

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

ENC - LKE51 - L I B

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Power Injector 1520 Series

Three Axis Digital Readout System

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

OM2000N INSTALLATION MANUAL

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

In-process inspection: Inspector technology and concept

One channel video link With duplex data and contact closure

Fibre Optic Modem ODW-611

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

CrystalView DVI Micro-DL Extender

LONWORKS Fibre Optic Converter

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 9

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

CLR-101C CAMERA LINK REPEATER. User s Manual. Document # , Rev 1.0, 2/24/2013

PicoScope 4000 Automotive PC Oscilloscopes

ViaLiteHD Fibre Optic Green OEM Link Modules

LONWORKS Fibre Optic Router

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

HD-One DX/DX500 HDMI Extender

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Installation and user s guide M A. HS20 installation guide

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Magnetic Sensor - Incremental EHP

PicoScope 3000 Series Automotive User guide

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

02/11/2015

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Technical data. General specifications. Indicators/operating means

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Model Number Structure

VGA to DVI Extender over Fiber SET

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Assembly. Front view. LEDs. Parametrization interface. Power Bus

TBC & Matrix Switcher TBC-5000 Instruction Manual

DATA SHEET Panorama Rudder Indicator, TRI-2

Multifunction Digital Timer

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Electrical connection

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Transcription:

Installation guide M-9653-9278-01-D (dual output) encoder system RSLM high accuracy linear encoder

Renishaw plc declares that complies with the applicable standards and regulations. A copy of the EC Declaration of Conformity is available on request. FCC compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that any changes or modifi cations not expressly approved by Renishaw plc or authorised representative could void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance. Further information Further information relating to the encoder range can be found in the system Data sheet (L-9517-9337). This can be downloaded from our website www.renishaw.com/encoder and is also available from your local rep re sent a tive. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. Disclaimer RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. RoHS compliance Compliant with EC directive 2002/95/EC (RoHS) Patents Features of Renishaw s encoder systems and similar products are the subjects of the following patents and pat ent applications: JP 3,202,316 US 5,241,173 EP 0514081 EP 0543513 US 5302820 US 5,861,953 EP 0748436 US 6,481,115 B1 IL 138995 US 6,775,008 B2 EP 1173731 IL146001 GB 2397040 CN 1293983C US 7,367,128 JP2005533247 CN 0543424 US 7659992 US 7624513 The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor.

Storage and handling Readhead Readhead Interface N-heptane Acetone CH 3 (CH 2 ) 5 CH 3 CH 3 COCH 3 Chlorinated Solvents Propan-2-ol CH 3 CHOHCH 3 Methylated Spirits Readhead Storage +70 C -20 C Operating +70 C 0 C Humidity Rated up to +40 C, <95% relative humidity (non-condensing)

readhead installation drawing (RELM/RSLM scale shown. For other scales, see relevant system installation guide) Dimensions and tolerances in mm Reference mark selector (A-9653-0143) (Only required for T readheads) (Yaw tol. ±0.4 ) / / 0.25 3 Reference mark selector sensor position P and Q limit switch sensor position Alternative mounting face (Roll tol. ±1.0 ) / / 0.24 15.1 14.7 3.7 13.5 P limit magnet (A-9653-0138) 15 Forward direction of readhead relative to scale 16 18 7.8 7.8 31 Optical centreline (incremental and reference mark) 3 2 off mounting holes M2.5 through, counterbored Ø3 x 2.75 deep from alternative mounting face Q limit magnet (A-9653-0139) Recommended mounting faces 4.25 4.15 13.8 ±0.15 6 min Set-up LED >R20 Dynamic bend radius >R Static bend radius CAL/AGC LED Detail A Ø 4.25 ±0.25 11.5 35 23 A 2 off mounting holes M2.5 through, counterbored Ø3 x 2.3 deep both sides (Pitch tol. ±1.0 ) / / 0.6 Scale reading surface Adhesive thickness 0.2 Scale thickness 1.5 ±0.1 1.5 6.3 22 29 Readhead to scale clearance Rideheight 2.1 ±0.15 Dimensions from substrate surface

interface installation drawing Dimensions and tolerances in mm quick-start guide 8.7 33.3 2.8 (0.11 inch) This section is a quick-start guide to installing a TONiC system. More detailed information on installing the system is contained in the following sections of the installation guide. INSTALLATION Ensure scale, readhead optical window and mounting faces are clean and free from obstructions. 4-40 UNC hex standoff 2 positions Output 26 way hi-density D-type plug 36 3 7 External earthing tag 14.2 21 Plug the readhead cable into the interface under the cover plate and reassemble interface. Connect to receiving electronics and power-up. Ensure AGC is switched off - the CAL LED on the readhead should be off (if not press and hold the CAL button on the interface until the CAL LED on the readhead switches off). 21 Install and align the readhead to maximise signal strength over the full axis travel as indicated by the readhead and interface set-up LEDs (readhead - green; interface - ideally blue/purple). 59.3 Ø3.5 Clearance holes for M3 cap screws and star washers or alternative Calibration button Set-up LED 15 Readhead cable 48 32 PORT NOT CONNECTED 53 9 12.4 Mounting for 35 mm DIN rail (EN5022) Cable exit Access hatch for readhead cable connection 37.3 85 93.5 CALIBRATION Press and release the CAL button on the interface. The CAL LED on the readhead will be single fl ashing. Move the readhead along the scale at slow speed (<0 mm/s), without passing a reference mark, until the CAL LED starts double fl ashing. If a reference mark is not being used, the calibration routine should now be exited by pressing the CAL button. If a reference mark is being used move the readhead back and forth over the selected reference mark until the CAL LED stops fl ashing and remains off. The system is now calibrated and ready for use. AGC can now be switched on if required by pressing and holding the CAL button until the CAL LED on the readhead switches on. CAL values and AGC status are stored in readhead non-volatile memory at power down. NOTE: If calibration fails restore factory defaults by pressing and holding the CAL button whilst switching on. Then repeat the installation and calibration routine.

System connection Approved ESD precautions must be followed at all times during readhead and interface electrical connections. The readhead is connected to the interface via a small, rugged connector to allow for easy feed-through during installation. Connecting the readhead Remove the cover plate as shown (2 x M2.5 hex head screws). Taking care not to touch the pins, plug the connector into the socket in the interface, ensuring correct orientation as shown. Refi t the cover plate ensuring the cable ferrule is located in the recess on the inside and no wires are trapped under the cover plate. Cover plate Readhead mounting and alignment Mounting brackets The bracket must have a fl at mounting surface and should enable conformance to the installation tolerances, allow adjustment to the rideheight of the readhead, and be suffi ciently stiff to prevent defl ection or vibration of the readhead during operation. Readhead set-up Ensure that the scale, readhead optical window and mounting face are clean and free from obstructions. To set nominal rideheight, place the readhead spacer with the aperture under the optical centre of the readhead to allow normal LED function during set-up procedure. Adjust the readhead to maximise the signal strength and achieve a green set-up LED on the readhead (70 to 135% signal). Aim for a blue LED on the interface. NOTE: The readhead should be installed and set-up with the AGC switched off. Readhead set-up LED status Green Orange Red Yaw 0 ±0.4 Disconnecting the readhead Remove the cover plate on the interface (2 x M2.5 hex head screws). Gently lever the connector PCB (on the end of the cable) out of the socket. Place the connector in an anti-static bag. Refi t the cover plate. Pitch 0 ±1.0 Roll 0 ±1.0 Green spacer Rideheight 2.1 ±0.15 mm Interface SIG and OPT LED status Blue Green Orange Red RELM/RSLM scale shown. For other scales, see relevant system installation guide.

System calibration Calibration is an essential operation that completes readhead set-up, with the optimum incremental and reference mark signal settings stored in the readhead non-volatile memory. Before system calibration, install the readhead to maximise the signal strength throughout the axis travel. NOTE: CAL routine maximum speed <0 mm/s Step 1 Incremental signal calibration Ensure Automatic Gain Control is switched off (CAL LED on readhead is not illuminated) before beginning calibration. Press and release the CAL button on the end of the interface as shown. The CAL LED will now periodically single-fl ash to indicate that it is in incremental signal calibration routine. Move the axis at slow speed, ensuring you do not pass the reference mark. The CAL LED will double-fl ash periodically, indicating the incremental signal is now calibrated and the new settings are stored in the readhead memory. The system is now ready for reference mark phasing. CAL button Set-up LED { NOTE: The LED on the interface will flash blank when the reference mark is detected (<0 mm/s only). It indicates the presence of a reference mark not the phasing status. Switching Automatic Gain Control on or off AGC can be switched on or off via the interface CAL push button switch. Press and hold the CAL button on the interface for >3 seconds to switch AGC on or off. The CAL LED on the readhead will be illuminated when AGC is active. NOTE: The system must be calibrated before switching AGC on. Txxxx Readhead LED diagnostics Set-up CAL LED Incremental Reference mark Operating Indication Green Orange Red Green (flash)* Orange (flash) Red (flash) On Off Status rmal set-up: signal level 70% to 135% Acceptable set-up; signal level 50% to 70% Poor set-up; signal may be too low for reliable operation; signal level <50% rmal phasing Acceptable phasing Poor phasing; recalibrate Automatic Gain Control On Automatic Gain Control Off NOTE: For systems without a reference mark, go to Calibration routine - manual exit Step 2 Reference mark phasing Move the axis until the reference mark passes the readhead optical centre in any direction, the CAL LED will continue to double flash periodically. Move the readhead back over the selected reference mark; the CAL LED will stop fl ashing and remain off. The reference mark is now phased. The system automatically exits the CAL routine and is ready for operation. Calibration routine - manual exit To exit the calibration routine at any time press and release the CAL button. The CAL LED will stop fl ashing and remain off. If step 1 is complete (CAL LED is periodically double-fl ashing) the incremental signal CAL settings will be stored. Reference mark phasing settings will not be stored for CAL manual exit. If the calibration routine has not been completed, restore factory defaults and then repeat the full calibration. Restoring factory defaults When re-installing the system, or in the case of incomplete calibration, the factory defaults should be restored. To restore factory defaults; Switch system off. Press and hold the CAL button whilst switching the system on. The CAL LED on the readhead will fl ash several times, indicating that the factory defaults have been restored. Release CAL button. Check the Readhead mounting/installation and re-calibrate the system. Calibration Reset Single flashing Double flashing Flashing at power-up (<2s) interface set-up LED diagnostics Signal Incremental Reference mark Purple Blue Green Orange Red Indication Purple / blank - flashing Blue / blank - flashing Red / blank - flashing Blank flash Calibrating incremental signals Calibrating reference mark Restoring factory defaults *Flash will effectively be invisible when incremental signal level is >70% when passing reference mark. Status rmal setup; signal level 1% to 135% Optimum setup; signal level 90% top 1% rmal set-up: signal level 70% to 90% Acceptable set-up; signal level 50% to 70% Poor set-up; signal may be too low for reliable operation; signal level <50% Over signal; system in error Over speed; system in error Poor set-up; signal level <20%; system in error Reference mark detected (speed <0mm/s only) Alarm output* *-Alarm output will take the form of 3-state or line driven E signal depending on interface confi guration. Also, some confi gurations do not output overspeed alarm. See TONiC Data Sheet (L-9517-9411) for details of interface confi guration. -Momentary status only, while fault condition remains. -Alarm may result in axis position error, re-datum to continue. Yes Yes Yes NOTE: System must be re-calibrated after restoring factory defaults.

Connections output Electrical connections system grounding and shielding Readhead Inner shield Interface Extension cable max. 50m dependent on output frequency Customer electronics 5 V 26 pin high density D type plug Outer shield 0 V Output signals Function Output type Signal Pin Power 5 V Power 26 Incremental signals 5 V Sense 0 V Power 0 V Sense A+ 18 9 8 24 IMPORTANT: The outer shield should be connected to the machine earth (Field Ground). The inner shield should be connected to 0 V at receiving electronics only. Care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues. RS422A digital A- B+ B- 6 7 16 NOTE: The external earthing tag on the interface should be used when mounting the interface on a DIN rail. NOTE: Maximum cable length between readhead and interface is m. Reference mark Cosine Analogue Sine RS422A digital V 1 + V 1 - V 2 + V 2 - Z+ Z- 1 19 2 11 15 23 Recommended signal termination Digital outputs Limit outputs Analogue outputs Alarm Limits Readhead set-up Shield Analogue RS422A digital Open collector V 0 + V 0 - E+ E- P Q X Inner shield Outer shield 12 20 25 17 4 13 t connected Case Interface A B Z E+ A B Z E- Cable Z 0 = 120R 120R Customer electronics Standard RS422A line receiver circuitry 5 to 24 V P Q R* *Select R so max. current does not exceed 20 ma Alternatively, use a suitable relay or opto-isolator V 0 V 1 V 2 + V 0 V 1 V 2-120R

Output specifications Digital output signals Form - Square wave differential line driver to EIA RS422A (except limits P and Q) Analogue output signals NOTE: Analogue signals are also available direct from all TONiC readheads Incremental 2 channels A and B in quadrature (90 phase shifted) Incremental 2 channels V 1 and V 2 differential sinusoids in quadrature (90 phase shifted) Model P (µm) S (µm) Signal period P 0004 20 5 20 µm Resolution S 0020 4 1 0040 00 0200 2 0.8 0.4 0.5 0.2 0.1 (V 1 +)-(V 1 -) 0 0.7 to 1.35 Vpp with green LED indication (readhead) and 120R termination. Centred on 2.5 V A B 0400 00 0.2 0.08 0.05 0.02 (V 2 +)-(V 2 -) 2000 0.04 0.01 4000 0.02 0.005 KD 0.008 0.002 20KD 0.004 0.001 Reference Reference Z Synchronised pulse Z, duration as resolution 0.8 to 1.2 Vpp Wide reference (V 0 +)-(V 0 -) 45 360 (nom) Bi-directionally repeatable Differential pulse V 0 centred on 45 Z Synchronised pulse Z,duration as signal period NOTE: Select standard or wide reference at time of ordering, to match the requirements of the controller being used. Limits Open collector output, asynchronous pulse Alarm Asynchronous pulse P Q Active high or Active low Repeatability <0.1 mm ~ Length of limit actuator P Q Repeatability <0.1 mm ~ Length of limit actuator E >15 ms Alarm asserted when signal level is less than 20% or greater than 135%. Alarm is also asserted if readhead speed is too high for reliable operation. or 3-state alarm (option) Differentially transmitted signals forced open circuit for >15 ms when alarm conditions valid. Set-up* 1 Voltage at X Setup signal voltage proportional to incremental signal amplitude 0 0 Signal level 0% * Set-up signal as shown is not present during calibration routine Inverse signals not shown for clarity

General specifications Power supply 5 V ±% Readhead only <0 ma System <275 ma NOTE: Current con sump tion fig ures refer to unterminated systems. For digital outputs a fur ther 25 ma per chan nel pair (eg A+, A-) will be drawn when ter mi nat ed with 120 Ω. For analogue outputs, a further 20 ma will be drawn when terminated with 120 Ω. Power from a 5 V dc supply complying with the requirements for SELV of standard EN (IEC) 60950. Ripple 200 mvpp maximum @ frequency up to 500 khz Temperature (system) Storage -20 C to +70 C Operating 0 C to +70 C Sealing (readhead) IP40 (interface) IP30 Acceleration (readhead) Operating 500 m/s 2 BS EN 60068-2-7:1993 (IEC 68-2-7:1983) Shock (system) n-operating 00 m/s 2, 6 ms, ½ sine BS EN 60068-2-27:1993 (IEC 68-2-27:1987) Vibration (system) Operating 0 m/s 2, 55 Hz to 2000 Hz BS EN 60068-2-6:1996 (IEC 68-2-6:1995) Mass Readhead g Interface 205 g Cable 26 g/m Environmental Compliant with EU Directive 2002/95/EC (RoHS) Readhead cable Double shielded, outside diameter 4.25 ±0.25 mm. Flex life >20 x 6 cycles at 20 mm bend radius. UL recognised component Maximum cable length Readhead to interface m Speed Minimum receiver clock frequency (MHz) 50 40 25 20 12 8 6 4 1 Analogue output 0004 5 µm 4.2 0020 1 µm 9 8. 6.48 4.50 3.37 0.84 0040 0.5 µm 8. 6.75 4.50 4.05 3.24 2.25 1.68 0.42 00 0.2 µm 6.48 5.40 3.24 2.70 1.80 1.62 1.29 0.90 0.67 0.16 Maximum speed (m/s) 0200 0.1 µm 3.24 2.70 1.62 1.35 0.900 0.8 0.648 0.450 0.338 0.084 0400 50 nm 1.62 1.35 0.8 0.675 0.450 0.405 0.324 0.225 0.169 0.042 (-3dB) 00 20 nm 0.648 0.540 0.324 0.270 0.180 0.162 0.130 0.090 0.068 0.017 2000 nm 0.324 0.270 0.162 0.135 0.090 0.081 0.065 0.045 0.034 0.008 4000 5 nm 0.162 0.135 0.081 0.068 0.045 0.041 0.032 0.023 0.017 0.004 KD 2 nm 0.065 0.054 0.032 0.027 0.018 0.016 0.013 0.009 0.0068 0.0017 20KD 1 nm 0.032 0.027 0.016 0.013 0.009 0.0081 0.0065 0.0045 0.0034 0.0008 Angular speed depends on ring diameter - use the following equation to convert to rev/min. V x 00 x 60 Angular speed (rev/min) = Where V = maximum linear speed (m/s) and D = external diameter of RESM or REXM (mm) π D Interface to controller Receiver clock frequency (MHz) 40 to 50 <40 analogue Maximum cable length (m) 25 50 50 Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential.

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire GL12 8JR United Kingdom T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com www.renishaw.com RSLM high accuracy linear encoder For worldwide contact details, please visit our main website at www.renishaw.com/contact RENISHAW and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc. 20-2011 Renishaw plc All rights reserved Issued 11 *M-9653-9278-01*