User s Guide. PHB-900 Series. ph Benchtop Meters.

Sartorius Professional Meter

WQ Series Water Quality Bench top Meters

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Good Laboratory Practices (GLP) Notepad. Automatic Datalogging. Automatic Stability Function. P.I.N. Code Security Access.

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

USER MANUAL MODEL 650. TWO-WIRE ph/orp TRANSMITTER. um

Quality. Accurate, reliable results in a durable easy-to-use design

Instruction Manual ph/ion 510 Bench ph/ion/mv Meter

ph GENERAL INFORMATION

BASIC PH METER BASIC PH METER KIT

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

Large Display ORP Pen

Instruction Manual Alpha ph 190 1/8 DIN ph/orp Controller Transmitter ph / mv / ºC

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Specifications. Tougher. Smarter. More Versatile. YSI Professional Plus Water Quality Instrument

Instructions Manual

Instruction Manual Aquamon 2000 plus 2-Wire ph/orp Transmitter

Vinmetrica SC-200 User Manual

Real-time ph and Conductivity Data Acquisition with the ACQUITY UPLC H-Class Bio System, Auto Blend Plus, and the GE Healthcare Monitor ph/c-900

Assembly Level Service Guide

KHT 1000C HV-Probe Calibrator. Instruction Manual

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Operating Instructions

MANUAL ENGLISH Core Club Ordercode: D2314

Troubleshooting CS800/LC900 Bikes

CONDUCTIVITY + ph. ORION STAR A215 BENCHTOP ph/conductivity METER

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

PLL1920M LED LCD Monitor

NS-3 RF Noise Source Operation Manual

TVAC20000 User manual

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Quick Reference Guide

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

OSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD

CONDUCTIVITY + ph. ORION STAR A215 BENCHTOP ph/conductivity METER

SATRI AMPLIFIER AMP-51R. Owner s Manual

Operation Manual for. SCU1 Signal Conditioning Unit

the measure of confidence Thermo Scientific Orion Meter Brochure

Spectra Batten (Order code: LEDJ95)

TABLE OF CONTENTS. Instructions:

Model WP-80 ph-mv-temp. Meter Version : 3.51 Date : 02/07/2003 Author : MS

ABB Instrumentation Operating Instructions Series Transmitters. Second Retransmission Output Supplement All Models.

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

HD Digital Set-Top Box Quick Start Guide

TX2000 Intelligent ph/orp Transmitter

Evolution Digital HD Set-Top Box Important Safety Instructions

8 Port HD/SD-SDI Switch

Safety Precautions and Maintenance

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

COLOR TFT LCD MONITOR. Manual

Operating Instructions

LIGHT COPILOT II. elationlighting.com Internet:

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

LED Pixel Track Pro ORDERCODE 42205

DH551C/DH550C/DL550C Double Sided Display User Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Fiber Optic Meter Fiber Optic Source

Model KT 53 Cooling incubators with thermoelectric cooling

Oxygen ORDERCODE D2150

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Metal Electrode Meter

IMPORTANT SAFETY INSTRUCTIONS

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

ENGLISH Antenna Distributor

600 Series Video Surveillance Monitors

HD-CM HORIZON DIGITAL CABLE METER

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Total Chlorine Sensor

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

Noise Detector ND-1 Operating Manual

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

ST-200Pro. Electrolyte Analyzer OPERATOR S MANUAL

Installation Note. Agilent 89441A Option AYC Installation Kit

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

ScienceLine ph combination electrodes

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

DCX-24 ORDERCODE D2020

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

PATTERN GENERATOR PG-3D1X USER MANUAL V.2012PG-3D1X101.00

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Model KT 115 Cooling incubators with thermoelectric cooling

Transcription:

This document courtesy of: Data Weighing Systems, Inc. Contact Us For immediate assistance call 1-800-750-6842

Operation Manual Sartorius Basic Meter PB-11 98648-012-08

Contents 4 General View 6 Warning and Safety Information 7 Installing and Maintaining Electrodes 9 Standardizing for ph Measurement 13 Using Setup 15 Standardizing for Millivolt Measurement 18 Understanding ph Theory 19 Temperature Compensation 20 Measuring ph 21 Troubleshooting 23 Meter Specifications 24 Accessories 25 C Declaration of Conformity 3

General View Front View 1 2 3 Display 13 12 11 10 Sal TDS S C %DO mg/l m S/cm K µ cm ion rel mv ph M OK Set Error Clear 1234567810101213 1.68 4.01 6.86 9.18 12.46 14 Auto Man 1 %/ C 2 3 S1 S2 S3 4 5 6 7 8 9 1 Setup button: Press to clear buffers, review electrode calibration or select new autorecognized buffers 2 Mode button: Press to toggle between ph and mv mode 3 Standardize button: Press to enter each buffer 4 Enter button: Press to select menu item options 5 Measuring icon 6 Temperature 7 Mode 8 Result 9 Prompts 10 Buffer icons 11 Icon: standardization (calibration of the meter) in process 12 Stability icon 13 Standardizing icon 14 Standardization result 4

Rear View 1 2 3 4 1 Power cable connector 2 Reference electrode connector (used with separate reference electrodes) 3 BNC electrode connector 4 Temperature compensation probe connector 5 AC adapter Connecting to a Power Source 5 1 5

Warning and Safety Information For safety and operating reasons, only authorized service technicians may open the Basic Meter PB-11 housing. Therefore, only authorized technicians may repair or perform maintenance on this ph meter. Any tampering with the ph meter or negligent or intentional damage to this equipment will void any warranty claims against the manufacturer. If liquid gets into the ph meter, unplug it from AC power (mains supply) and have an authorized service technician check the ph meter. If you do not plan to use this ph meter for a relatively long period, please disconnect it from AC power. For safety reasons, use this equipment only for the application described in this operation manual. Make sure that the buffers used for standardizing have exactly the same values that are stored. 6

Installing and Maintaining Electrodes 1. Remove the protective end cover from the electrode. 2. Before first use of your electrode, or whenever the electrode is dry, soak overnight in a standard solution or KCI solution. 3. Remove the shorting cap on the ph meter connector. Install the electrode by plugging the BNC and ATC connectors into the jacks on the rear panel. 7

4. Option: Install an ion selective electrode by removing the BNC shorting cap and plugging the BNC connector (twist-lock) into the BNC jack. If a combination electrode is not available, plug the separate reference electrode into the ref pin. Reference Electrode ISE 5. Clean the electrode between each measurement with distilled water or deionized water, or part of the next solution to be measured. 6. Store glass ph electrodes in KCI solution or electrode filling solution. Make sure the liquid level of the internal filling solution is always a few centimeters higher than that of the measurement solution. 8

Standardizing for ph Measurement Because electrodes vary in their response, you must standardize (calibrate) your ph meter and electrode to compensate for electrode variation. The more frequently you standardize, the more accurate your measurements. Standardize daily, or more often, for accurate results. This ph meter allows automatic standardization using up to three buffers. Press the Standardize button again to delete all the standardization data stored up to that point. The ph meter performs automatic temperature compensation. 1. Immerse electrode in a buffer solution. Stir gently. Allow the electrode to reach a stable value. 2. Press the Mode button until your digital display indicates ph mode. This button toggles between ph and mv modes. 9

3. Clear existing buffers when doing a new 2- or 3-point standardization. Use the Setup button. Also use the Setup button to select the individual sets of buffers. (See page 13.) [Standardize] 4. Press Standardize. The meter recognizes the buffer and flashes a buffer icon. When the signal is stable, the buffer is entered. By pressing ENTER you can also enter the current buffer directly. 5. The meter displays the slope of the electrode as 100.0%. On entering a second or third buffer, the meter performs a diagnostic check on the electrode and displays the slope. (See step 7 ff.) 10

[Standardize] 6. To enter a second buffer, place the electrode in the second buffer solution, stir, allow time for the electrode to stabilize, and press Standardize again. The meter recognizes the buffer and displays the first and second buffer values. 7. Next, the meter performs a diagnostic test of the electrode. The display indicates either Good Electrode ( OK ) or Electrode Error ( Error ). The meter also displays the slope of the electrode. 8. Error indicates that your electrode or the buffer is not working properly, or a wrong set of buffers has been selected. The electrode response must be between 90 and 105% slope. (See Troubleshooting, on page 21.) Press Enter to clear the Error, then try re-entering the buffer as described in step 6. [Standardize] 9. To set a third standard, place the electrode in the third buffer solution, stir, allow to stabilize, and press Standardize. The results will be the same as in steps 6 and 7, except the display will show three buffer values. 11

10. After entering three buffers, the Standardizing icon goes out and the Measuring icon appears on the display to indicate that the meter returns to Measuring operation.! Note: The meter continually adjusts for temperature. Therefore, buffers may vary slightly from the nominal values because of temperature. 11. Standardize your ph meter using at least two buffers with ph values bracketing the expected ph of your samples. Stirring with a magnetic stir bar provides faster electrode response. 12

Using Setup [Setup] The Setup button lets you clear all the standardization data that you have entered, review calibration information, or select the buffer set that you want. You can escape the setup mode at any time by pressing ph/mv. 1. Press Setup once to clear all buffers you have entered. If you are sure you want to clear the buffers, press Enter. The meter clears all buffers and returns to Measuring. [Enter] 2. Press Setup again to show electrode performance, slope and the first and second calibration points. The two buffer values will also be displayed. 2+ [Setup] 3. Pressing Setup again shows the electrode slope between the second and third buffers (if three buffers have been entered) and shows the second and third buffer icons. 13

[Setup] 4. Press Setup again to display a Set Buffers icon and to display the first buffer set icons. [Setup] or [Enter] 5. Press Enter to select the set of buffers shown on the display or Press Setup again to toggle between the existing sets of buffers. 6. Press Enter to select the displayed buffer set that contains the buffer you want to use. Press Setup again, or press the Mode button at any time to return to Measuring.!Note: You may select buffers from different sets. 14

Standardizing for Millivolt Measurement (Relative Millivolt) You will normally use millivolt measurements for determining ion concentration and for measuring redox potential (also called ORP, oxidation reduction potential). You will use an ion selective electrode (ISE), combined with a reference electrode, to measure ion concentration. The ISE senses the ion concentration and responds with a millivolt potential. The millivolt readings are then used to determine ion concentrations (on the basis of a previously entered calibration curve). You will normally use a redox/orp electrode to measure redox potential (ORP). ORP measurements indicate the oxidizing or reducing capability of a solution. You can use ORP values to monitor or control solutions requiring a set amount of oxidants or reductants. 1. Immerse electrode in a standard solution. 15

[Mode] 2. Press Mode until your digital display indicates mv mode. [Standardize] 3. Press Standardize to enter an mv standard and read relative mv. 4. When the signal becomes stable, or when you press Enter, the current absolute mv value (offset) becomes zero relative millivolts. 16

[Setup] 5. To clear an mv offset and return to absolute millivolt mode, press Setup. The meter displays a flashing Clear icon, and shows the current relative millivolt offset. [Enter] 6. To clear the previous mv offset, press Enter. You then return to absolute mv mode. 17

Understanding ph Theory Defining ph The measurement of ph plays an important role in identifying and controlling acidity and alkalinity levels for industry and research. ph is a measure of the acidity or alkalinity of a solution and can be represented by this equation: ph = -log [H + ] with [H + ] representing the concentration of hydrogen ions in the solution. ph is sometimes referred to as the power of the hydrogen ion in a solution. By using a ph meter, you can determine exact ph levels of solutions. For example, rather than say that lemon juice is quite acidic, you can say that lemon juice has a ph of 2.4. An exact ph value can be used to control or measure acidity levels for manufacturing processes or for basic research. ph values generally range from 0 to14, with a ph of 7 being the neutral point, or the value of pure water. ph values greater than 7 represent increasing alkalinity, whereas ph values below 7 represent increasing acidity (Figure 1). more acidic ph 0 Strong Acid 1 2 Lemon Juice 3 4 Tomato Juice 5 Coffee 6 Neutral 7 Pure Water 8 Baking Soda more basic 9 10 11 (sodium hydrogen carbonate) 12 Ammonia 13 14 Strong Base Figure 1. ph scale showing the relative acidity or basicity of some common substances. 18

Temperature Compensation!Note: Automatic temperature compensation only functions properly if a temperature probe is connected. Temperature compensation influences the results in two different ways: 1. ph values of the buffers change as a function of temperature. Each buffer varies as a function of the temperature of the respective solution. Typically, these values are indicated on the buffer label. The values detailed in the table below apply to most technical buffers. Standard buffers: ph 4.00 ph 7.00 ph 10.00 0 C 4.005 7.13 10.34 5 C 4.003 7.10 10.26 10 C 4.001 7.07 10.19 15 C 4.002 7.05 10.12 20 C 4.003 7.02 10.06 25 C 4.008 7.00 10.00 30 C 4.010 6.99 9.94 35 C 4.020 6.98 9.90 40 C 4.030 6.97 9.85 50 C 4.061 6.97 9.78 If standardization is performed in the ph mode, the ph value is adapted to the nominal value of the current temperature. For example, if the buffer has a nominal ph of 7.00 at a temperature of 25 C, the meter will standardize the buffer to 7.02 instead of 7.00 at a temperature of 20 C. 2. Electrode slope changes as a function of temperature. Theoretically, the change of voltage per ph unit is approx. 59.16 mv at 25 C. However, this mv per ph unit changes as a function of temperature. The meter compensates for these changes by taking into account the temperature dependency of the Nernst factor when calculating ph values. 19

Measuring ph To measure ph with a conventional glass ph electrode, the meter uses a ph-sensing glass bulb that is sensitive to hydrogen ions. The potential developed at the glass membrane is directly related to the ph of the solution. Reference Electrode Porous Junction (Diaphragm) The glass electrode is paired with a reference electrode which completes the electrical measuring circuit and provides a stable reference point. These two electrodes are joined to create a combination electrode. The combination glass electrode is connected to the ph meter which reads the voltage, converts it to ph units, and displays the result. ph Sensor Temperature sensor with automatic temperature compensation (ATC) 20

Troubleshooting 1. If the signal from the electrode is out of range, the display will show. This may happen when the electrode is not immersed in a solution. 2. The meter will display Error when it detects an error in electrode response. During standardization, the message indicates that the electrode is less than 90% or more than 105% of the correct response. The Error message can indicate either a bad electrode or bad buffer(s). 3. If the meter detects an error in the temperature measurement, the display shows - C. If you do not use a temperature probe, the meter uses the standard temperature (25 C). 21

Electrode Test ph=7 ph=4 ph=10 0 ± 30 mv 169 to 186 mv more than ph 7 159 to 185 mv less than ph 7 4. To test the ph electrode, place it in a good ph 7 buffer. Press ph/mv to use the mv mode, and note the millivolt reading. Repeat for either a ph 4 or ph 10 buffer. The electrode signals must be within the limits shown below (when temperature is approx. 25 C). Power Ref Input ATC 5. To test the meter for correct operation, install the BNC (input) shorting cap. Press ph/mv to select the mv mode, and note the mv reading. If the meter reads 0 ± 0.3 mv, it is measuring correctly. Note that a long-term drift of 0.1 mv/month since last calibration is specified. 22

Meter Specifications ph 2.00 bis +20.00 Readability 0.01 Accuracy ± 0.01 mv 1800.0 to 1800.0 mv Readability 0.1 mv Accuracy ± 0.2 mv (0.05% if < 400 mv/>+ 400 mv) Temperature range 5.0 to +105.0 C Readability 0.1 C Accuracy ± 0.2 C Calibration points Maximum 3 buffers Automatic buffer recognition 16 buffers 2; 4; 7; 10; 12 1; 3; 6; 8; 10; 13 1.68; 4.0; 6.86; 9.18; 12.46 Automatic temperature compensation Automatic electrode slope correction between 90 105% of the theoretical slope 23

Accessories Order No. ph combination electrodes: Plastic body with built-in temperature sensor, KCI liquid-filled PY-P10 Glass body with built-in temperature sensor KCI liquid-filled, platinum junction PY-P11 Plastic body with built-in temperature sensor, gel-filled PY-P12 Plastic body, gel-filled PY-P20 Glass body, KCI liquid-filled, platinum junction PY-P21 Temperature Probe PY-T01 Other ph electrodes and sensors for special measuring conditions including ion selective electrodes and redox electrodes are also available on request. 24

25

26

Sartorius AG Weender Landstrasse 94 108 37075 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. Status: March 2004, Sartorius AG, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine W1A000 BasicMeter PB11 KT Publication No.: WPB6004-e04032