AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

Similar documents
CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016

Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018)

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION

SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053

May 2016 DIVISION 3 - CW 2145-R4 TABLE OF CONTENTS

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

MATERIAL SPECIFICATION FOR SIGNAL HEADS

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

GENERAL REGULATIONS FOR THE PRESENTATION OF THESES

Signalling Cable Equivalent Sizes (formerly RT/E/C/11213)

Toronto Hydro - Electric System

HIGH COURT OF BOMBAY AT GOA

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

TECHNICAL SPECIFICATION

The University of Texas at Austin September 30, 2011

Advanced security made easy PRO-555. Day/Night CCD Security Camera. Operating Instructions SW331-PR5 SR331-PR

Signalling Cable Equivalent Sizes

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

AWT150C/AWT150CS/ AWT151C CCD Camera

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

SPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4)

GAMING COMMISSION REGULATIONS ESTABLISHING MINIMUM STANDARDS FOR SECURITY AND SURVEILLANCE

-Technical Specifications-

Colour Explosion Proof Video Camera USER MANUAL VID-C

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

)454 ( ! &!2 %.$ #!-%2! #/.42/, 02/4/#/, &/2 6)$%/#/.&%2%.#%3 53).' ( 42!.3-)33)/. /&./.4%,%0(/.% 3)'.!,3. )454 Recommendation (

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Draft for Public Comment

Telecommunication Infrastructure Project September 20, 2002

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

SECTION 686 VIDEO DECODER DESCRIPTION

SPECIAL SPECIFICATION 1118 Dual OC-3 ATM MPEG-2 Encoder

CCTV BASICS YOUR GUIDE TO CCTV SECURITY SURVEILLANCE

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Fixed Signals - Rules 1 to 23

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Standards for the Format and Binding of a Thesis

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

REDFISH TECHNOLOGIES

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

INSTALLATION MANUAL. ST-CVTMD420-WPIR-W Covert Motion Detection Color Camera. v1.3 8/11/11 1

PERFORMANCE SPECIFICATION SHEET

March 4 th, Addendum No. 1. Brooklyn College Systems Integrator Broadcast Television Equipment Project No: BY019/

Sealed Linear Encoders with Single-Field Scanning

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

SKG ASSESSMENT GUIDELINES 573 (SUMMARY)

Telemetry Receiver Installation Guide

Special Specification 6293 Adaptive Traffic Signal Control System

DCI Memorandum Regarding Direct View Displays

Simple all-in-one design style with front stereo speakers and natural ventilation system

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

COLORSCAN. Technical and economical proposal for. DECOSYSTEM / OFF.A419.Rev00 1 of 8. DECOSYSTEM /OFF A419/09 Rev November 2009

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

1. The contractor shall ensure that: c) Contractor or sub-contractor has at least 5 years experience

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

900-Lumen Portable LED Projector Part #: User manual

This Chapter does not apply to applications and decisions on, development on land reserved in corridor maps.

Kodak Ektapro HS Motion Analyser

SPECIAL SPECIFICATION 6740 Video Imaging Vehicle Detection System

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists

Global Trade Medical Supplies

PERFORMANCE SPECIFICATION SHEET

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Linear encoders without bearings incremental System for linear motion feedback

Mar11 Rev E

DETAIL SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, RFI SHIELDED, SERIES 2, CRIMP TYPE, BAYONET COUPLING, CLASSES A, D, L, T, W AND K

MONDO VIDEOSCREENS AND LED SOLUTIONS

MILITARY SPECIFICATION SHEET

Public Works Division Lighting District Fiber Optic Specifications April 2009

Preparing a home for TransACT fibre-to-the-premise (FTTP) services

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

Summer Training Project Report Format

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

2 Hour Electronic Boost Timer

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Linear flow controls VFC Linear flow controls with actuator IFC

1.0 GENERAL. 1.2 SUMMARY.1 Section Includes:

ELIGIBLE INTERMITTENT RESOURCES PROTOCOL

SYMPHONIC LIMITED PRESSING AGREEMENT (For Use By Canadian Orchestras)

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

In-process inspection: Inspector technology and concept

Transcription:

Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 409 November 2010 AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES OPSS 409.05.01 is superseded by: All cassette video tapes shall be a minimum of high quality, T120 length, unused and Super VHS format. The third paragraph of OPSS 409.07.01 is superseded by: A fixed camera shall be used for pipelines less than 200 mm in diameter. For pipelines equal to or greater than 200 mm a pan and tilt camera shall be used. OPSS 409.07.05 is superseded by: Reports shall be submitted to the contract Administrator in the following formats, within 10 working days of the completion of the field work, with the noted number of copies. a) One bound copy of the printed report in book format with serlox binding that must include: A copy of each Community map to reference work locations. A sleeve bound behind the last page to adequately hold each map. Photographs of pipe defects as requested. A hard cover with the following information: Book and video numbers. The community area (only one per book). Inspection dates. Sewer section numbers (e.g. 6439 to 6514) Total meters inspected in that book. b) Two 3.5 inch computer disks each containing the identical survey report information. c) One copy of the video recording. d) Two CD-ROM renderings/copies shall be provided by the contractor. Each CD-ROM shall be capable of having up to 2 hours of Full Frame Colour Video encoded onto it (i.e. one CD-ROM per video) in one continuous MPEG file. The CCTV data must also be CD-ROM compliant in that the video digits in the data accurately reflect the position on the CD-ROM. Amendments To OPSS 409 (APR 99) Construction Specification for Closed Circuit Television Inspection of Pipelines Page 1 of 2 TS 409 November 2010

The CCTV video recording (CD version) must be indexed to the textual data. The field survey must record the time index on the video which shows the images corresponding to the text record. The indexing must include the start time of the entire survey and the exact time number for each pipe feature/defect recorded in the data. This indexing will permit the user to view a particular sewer pipe or a particular feature/defect in a pipe, after inserting the appropriate CD, and then Advance to the stored time index in the MPEG file, then display the image(s). All required header information fields shall be completed and verified for correctness. The software used to produce the survey report shall not allow the operator to continue inputting information until the preceding field has been completed. The report shall be machine printed and presented according to the MSCC. All dimensions in the survey report shall be metric. Amendments To OPSS 409 (APR 99) Construction Specification for Closed Circuit Television Inspection of Pipelines Page 2 of 2 TS 409 November 2010

ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 APRIL 1999 CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES 409.03 DEFINITIONS 409.04 SUBMISSION AND DESIGN REQUIREMENTS 409.05 MATERIALS 409.06 EQUIPMENT 409.07 CONSTRUCTION 409.08 QUALITY ASSURANCE - Not Used 409.09 MEASUREMENT FOR PAYMENT 409.10 BASIS OF PAYMENT 409.01 SCOPE This specification covers the requirements for inspecting new and existing sanitary and storm pipe sewers, and pipe culverts by closed circuit television. 409.02 REFERENCES This specification refers to the following standards, specifications or publications: Water Research Centre (WRc) Publication: MSCC Manual of Sewer Condition Classification, Third Edition, 1993 Page 1 Rev. Date: 04/1999 OPSS 409

409.03 DEFINITIONS For this specification the following definitions apply: CCTV: means closed circuit television. Drainage Structure: means a catch basin, maintenance hole or ditch inlet. NAAPI: means North American Association of Pipeline Inspectors. 409.04 SUBMISSION AND DESIGN REQUIREMENTS A copy of the CCTV operator's current NAAPI Certification Certificate is to be provided to the Contract Administrator two weeks prior to the start of CCTV inspection operations. A copy of said certificate is required for each operator working on the contract. 409.05 MATERIALS 409.05.01 Video Cassette All video cassette tapes shall be a minimum of high quality, T120 length, unused and VHS format. 409.06 EQUIPMENT 409.06.01 Survey Vehicle The survey vehicle shall contain a separate area for viewing, recording and controlling the CCTV operation. The viewing and control area shall be insulated against noise and extremes in temperature. External and internal sources of light shall be controlled in a manner as to ensure the light does not impede the view of the monitor screen. Proper seating accommodation shall be provided to enable persons, in addition to the operator, to clearly view the monitor screen. All equipment utilized within the pipeline shall be stored outside the viewing, recording and control area. The vehicle shall include a telephone, or suitable alternative as agreed with the Contract Administrator for the duration of the work. 409.06.02 Survey Equipment The surveying equipment shall be capable of surveying a length of pipeline up to: a) 350 m where entry to the pipeline may be obtained at each end of the pipeline; b) 30 m where rodding is used; or c) 150 m where a self propelled unit is used when entry is at one end of the pipeline only. Page 2 Rev. Date: 04/1999 OPSS 409

Work shall not commence in a work shift until the Contract Administrator is satisfied that all items of the survey equipment have been provided and are in full working order. Each survey unit shall contain a means of transporting the CCTV camera in a stable condition through the pipeline. Where the CCTV camera is towed by winch and cable through the pipeline, all winches shall be stable during the entire CCTV inspection. All cables shall be steel or of an equally non-elastic material to ensure the smooth and steady progress of the CCTV camera. Each unit shall carry sufficient numbers of guides and rollers such that, when surveying, all cables are supported away from pipe and maintenance hole edges. All CCTV cables and lines used to measure the camera's location within the pipeline shall be maintained in a taut manner and set at right angles, where possible, to run through or over the measuring equipment. 409.06.03 Video Equipment Quality The electronic systems, television camera and monitor shall be of such quality as to enable the following to be achieved. 409.06.03.01 Camera The pan and tilt camera shall have the capability of panning the pipe at 360 with tilt capability of 275 to ensure complete inspections and view of all laterals and deficiencies. Resolution The live picture shall be visible with no interference and capable of registering a minimum number of lines of resolution at the periphery as indicated below: a) Fixed view camera 350 lines of resolution. b) Pan & Tilt camera 400 lines of resolution. Colour Constancy To ensure the camera provides optimum results when used with its own illumination source, the lighting shall be fixed to intensity prior to commencing the survey. To ensure colour constancy, no variation in illumination shall take place during the survey. 409.06.03.02 Video Cassette Recorder The video cassette recorder (VCR) shall be capable of reproducing a resolution, at the periphery, of a minimum of 250 lines recorded at standard VHS speed. The VCR shall have four heads. 409.06.03.03 Focus, Iris, Illumination The adjustment of focus and iris shall allow optimum picture quality to be achieved and shall be remotely operated. The illumination shall be such as to allow an even distribution of the light around the pipeline perimeter without the loss of contrast or flare out of picture shadowing. Page 3 Rev. Date: 04/1999 OPSS 409

409.07 CONSTRUCTION 409.07.01 CCTV Inspection The work shall include a CCTV inspection of the pipeline, and the preparation of all video, digital and written reports. Videos shall be recorded at standard VHS speed. The CCTV operator shall be certified by the NAAPI. A fixed camera shall be used for pipelines less than 300 mm in diameter. For pipelines equal to or greater than 300 mm a pan and tilt camera shall be used. At the start of each pipeline being surveyed, the length of pipeline from zero chainage up to the cable calibration point shall be recorded and reported in order to obtain a full record of the: a) pipe sewer length from the inside face of the maintenance hole to the inside face of the next maintenance hole or outlet end of the pipe sewer; or b) pipe culvert length from one end of the pipe culvert to the other. The metre reading entered on to the data display at the cable calibration point shall allow for the distance from the start of the survey to the cable calibration point such that the metre reading at the start of the survey is zero. In the case of surveying through a maintenance hole where a new header sheet is required, the metre reading shall be set at zero with the camera focused on the outgoing pipe entrance. At the start of each maintenance hole length, a data generator shall electronically generate and clearly display on the viewing monitor and video recording a record of data in alpha-numeric form containing the following minimum information: a) Automatic update of the camera's metre reading position in the pipeline from adjusted zero. b) Pipeline dimensions. c) Maintenance hole/pipe length reference numbers. d) Date of survey. e) Road name/location. f) Direction of survey. g) Time of start of survey. h) Pipeline use. Once the survey of the maintenance hole length is underway, an automatic update of the camera's metre reading position in the pipeline from zero, in metres and tenths of a metre, shall be continually displayed. The camera shall be stopped when defects are being noted on the coding sheet. Page 4 Rev. Date: 04/1999 OPSS 409

The survey shall be restarted at the opposite end of the pipeline if a blockage or obstruction is encountered. 409.07.02 Camera Position The camera lens shall be positioned centrally in the pipeline with a positioning tolerance of ± 10% of the vertical pipeline dimension. In all instances the camera lens shall be positioned looking along the longitudinal axis of the pipeline. 409.07.03 Camera Travel Speed The travelling speed of the camera in the pipeline shall be limited to: a) 0.1 m/s for pipeline of diameter less than 200 mm; b) 0.15 m/s for diameters exceeding 200 mm but not exceeding 310 mm; and c) 0.20 m/s for diameters exceeding 310 mm. 409.07.04 Camera Position Metre Reading Device A suitable metre reading device shall be used which enables the cable length to be accurately measured to indicate the location of the camera. The metre reading device shall be accurate to ± 1% of the length of the sewer being surveyed. The tolerance shall be demonstrated using one or both of the following methods in conjunction with a linear measurement audit form, which shall be completed each day during the survey: a) Cable calibration device. b) Tape measurement of the surface distance between maintenance holes. If the accuracy of the measuring device fails it is to be replaced. The Contract Administrator may require that those lengths of pipeline first inspected with the original measuring device be resurveyed using the new measuring device. 409.07.05 Survey Reporting Reports shall be submitted to the Contract Administrator in the following formats, within 10 working days of the completion of the field work, with the noted number of copies. a) 3 copies of the printed report. b) 2-3.5 inch computer disks each containing the identical survey report information. c) 2 copies of the video recording. All required header information fields shall be completed and verified for correctness. The software used to produce the survey report shall not allow the operator to continue inputting information until the preceding field has been completed. The report shall be machine printed and presented according to the MSCC. All dimensions in the survey report shall be metric. Page 5 Rev. Date: 04/1999 OPSS 409

409.07.06 Site Coding Sheets Each pipeline length shall be recorded according to the MSCC. Any variation from the manual shall be noted in the survey report. 409.07.07 Drawings One clean set of the Owner's drawings showing maintenance hole numbers, which coincide with the coding sheets and video tapes, shall be returned to the Contract Administrator on completion of the survey. The drawings shall be clearly annotated to show any discrepancies between the drawings and the survey report. Such discrepancies shall be brought to the attention of the Contract Administrator during the survey. 409.07.08 Pipeline Cleaning and Dewatering When specified, pipelines shall be cleaned and flushed immediately prior to inspection. 409.09 MEASUREMENT FOR PAYMENT 409.09.01 Actual Measurement Measurement for the CCTV inspection of pipelines is in metres measured on the ground surface from the: a) centre of one drainage structure to the centre of the adjacent drainage structure, or the outlet end of the sewer pipe; or b) one end of a pipe culvert to the other end of the pipe culvert. In the event that a CCTV inspection is terminated due to a blockage or collapsed pipe, or the pipe is inaccessible, measurement will be in metres for the actual length of pipeline inspected as determined from the chainage indication on the video tape. 409.09.02 Plan Quantity Measurement When measurement is by Plan Quantity, such measurement will be based on the units shown in the clause under Actual Measurement. 409.10 BASIS OF PAYMENT 409.10.01 CCTV Inspection Payment at the Contract price of the appropriate tender item for the installation of sanitary and storm pipe sewers, or pipe culverts shall include full compensation for all labour, equipment and material to do the work of CCTV inspection. Page 6 Rev. Date: 04/1999 OPSS 409