Setting up the communication between a Total Station and SiteMaster range of products

Similar documents
RF Solution for LED Display Screen

Quick Guide Book of Sending and receiving card

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0) on the disk sent with the printer. Follow the steps (see the picture):

1 Synchronising Xsens with the Delsys Trigno EMG System

Solutions for a Real Time World. Unigen Corp. Wireless Module Products. PAN Radio Modules Demonstration & Evaluation Kit UGWxxxxxxxxx (Part Number)

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

IxStream Headend. Quick Guide - Begin working with the IxStream headend. IX-Streamer, rev 1.1

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

RADIO FREQUENCY SYSTEMS

Auxiliary states devices

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

First Time Setup Guide

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

GWL/ Power Group Technology Solutions Stay Powered for the Future

Logic Controls LV3000 VGA Connected Virtual Pole Display

Fiber Optic Extender User Manual. Model: CV-F01-TX

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

Interface sheet - Edan ST-1212 Stress - CPET ergometer

Syntor X Flash Memory Module Revision C

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

TVS-2-TAIT VPU-15-TAIT

OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE

C Module Description

Instruction for Locking Tuner s Carriage(s) before Shipping

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

The Playful Invention Company. PicoCricket Troubleshooting. Version 1.2a

VIDEO ALARM VERIFICATION UNIT VIVER

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

Yellow Frog. Manual Version 1.1

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

Connecting To and Programming the LPC2148 Blue Board. Method 1 ISP (In-System Programming) w/ Flash Magic

Palette Master Color Management Software

Sky HD+ / Sky Q Module

Scan Converter Quick Installation Guide

HITS QT/QT+ Setup Instructions for QSD/QHD Services using: Drake SCT2x4 Headend Transcoder 2 Satellites/4 Multiplexes

Teacher s AIDE Training System. EZ Teach Silver Installation

Mortara X-Scribe Tango+ Interface Notes

Configuration Nordex CC

Narrow-Band Emergency Message System (EBEMS) - MT-63 Operating Instructions

Audio Design Associates (ADA)

Projection Display. Serial Interface Specification

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

C Module Description

Encoder Modulator. IPTV Setup

PLASMA MONITOR (PT20 UVVis) USER GUIDE

YAMAHA 03D SERIAL AUDIO MIXER

Library ebooks and Your Sony ereader

COPYRIGHT NOVEMBER-1998

Any feature not specifically noted as supported is not supported.

KARIN Operator manual WinKARIN 3.X

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

Universal DiSEqC controller USER MANUAL

Universal DiSEqC controller USER MANUAL SAT CONTROL

DVB-T USB SET-TOP BOX

1 OVERVIEW 2 WHAT IS THE CORRECT TIME ANYWAY? Application Note 3 Transmitting Time of Day using XDS Packets 2.1 UTC AND TIMEZONES

User Guide Mix-iT.ATEM v2.0. September User Guide Mix-iT for ATEM v2.0

My XDS Receiver- Affiliate Scheduler

EEG A1452 SCTE-104 Inserter Frame Card

SXGA096 DESIGN REFERENCE BOARD

User Manual. Product Link:

Douglas Lighting Controls Bluetooth Commissioning and Room Control App BT-APP

Harmony Smart Control. User Guide

This document describes the different ways to allow the automation system to close a gpi contact from the transmission list.

SHENZHEN H&Y TECHNOLOGY CO., LTD

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

D-Star the Easy Way Using the DV Dongle

Modbus for SKF IMx and Analyst

VSP 168HD Quick Start

YAMAHA 03D SERIAL AUDIO MIXER

The user manual of LED display screen and RH-32G control card.

In-situ Port Cal for Dual Carriages Tuner

Projector Management Application Version 7.00 Instruction Guide

Setup Guide. Quantum Data 70x/80x Series. Video Generators. Rev. 1.1

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Configuration Vestas VMP3500

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Receiver Integration Note

Topic: Instructional David G. Thomas December 23, 2015

Roku How To. a. Go to if you do not plan on purchasing premium channels or features.

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Viewing Serial Data on the Keysight Oscilloscopes

LUMINOUS TWO APP USER GUIDE FOR ANDROID

Mini Micro Pulse Lidar System

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Appendix Lightolier Compose System

S-Series Server Setup Quiz

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

My XDS Receiver- Affiliate Scheduler

2x50 ETHERNET MODULE

R4 AIS Class B Transponder

Pin Assignment for serial cables (RS232, 9-Pin)

Rack-Mount Receiver Analyzer 101

Transcription:

Setting up the communication between a Total Station and SiteMaster range of products Before we set up the communication, one important thing to know.. Please NOTE that to check any setup and take measurements with the Total Station in the SiteMaster software, YOU MUST add a STATION into your drawing. To do this, once communication has been established. Go into the Station Manager and ADD a NEW STATION station (after typing a Station No. in the top dialogue) Once done you will be able to go into the DRAW module and use the Icon to take measurements.

OK SETTING UP COMMUNICATION BETWEEN THE Total Station and Sitemaster Using Bluetooth We have 3 things to setup here 1. We must set the Total Station in Bluetooth mode 2. We must have the Bluetooth switched ON on the PC/PDA 3. We must use the Search for Bluetooth.. option in SiteMaster (note that this option will not appear if your Bluetooth is not switched on on your PC/PDA) If everything is set OK you will see Connected to Leica etc at the bottom of the dialogue. If everything is set OK you can proceed to adding a Station. (see page 1) If everything is not OK you may need to check the Communication Parameters using the Settings button.see below. Either way, please note that the default setting on the Total Station may be to use the PRISM. Please see below for how to switch between using the Prism and NOT using the Prism (using the laser) see end of this document. Using Serial Cable We have to setup. 1. Connect the cable between Total Station and device running SiteMaster 2. Set the data output on the Total Station see below 3. In SiteMaster set the Device Type, Port No, and check that the parameters match in the software and on the Total Station.

To use Bluetooth on the Total Station, you must tell it you want to use it. To do this you have to go into CONFIG > DATA OUTPUT and set BLUETOOTH SEE BELOW FOR SETTINGS If you want to use a serial cable, set the RS232 option for Data Output If you want to use Bluetooth set the Bluetooth option for Data Output (note when using Bluetooth, if it asks for a password code the default is 0000 (four zeros) Note that Endmark by default on the Serial option is CR/LF so presumably this is what needs to be set on the Bluetooth as well.

Setting up communications in SiteMaster. Using Bluetooth, select the Search for Bluetooth option. If using Serial connection select the Serial Connection and then the Settings (If checking the Bluetooth settings select Settings ) Note that with Leica s there are 2 protocols that can be used GSI and GEO, check you manual for the relevant setting. With some devices it may be necessary to check the Com port setting that the Bluetooth/Serial port is using and parameters..this can be done in Start > Control Panel > System > Hardware > Device Manager > Ports (COM & LPT). In SiteMaster set the port number as per below. (note that your settings may be different to what is documented below so check YOUR settings) Click the DETAILS.. button to access further settings, set them the same as the parameters set on the Total Station

SEE BELOW FOR SETTINGS If you want to use a serial cable, set the RS232 option for Data Output If you want to use Bluetooth set the Bluetooth option for Data Output (note when using Bluetooth, if it asks for a password code the default is 0000 (four zeros) Note that Endmark by default on the Serial option is CR/LF so presumably this is what needs to be set on the Bluetooth as well. Once the Parameters are set the same the only thing that may still be wrong is the COM Port notice above that I have 2.try one first then the other if no communication is made (if your not sure about the GSI / GEO bit repeat on each setting).

Once settings are correct, you should see Connected to Leica.etc at the bottom of the dialogue box below And you can then click the OK button To proceed into the software. Again.you must add a Station into The drawing before taking any Measurements Please refer to the first page of this Document for how to do this.

Switching between Prism and Laser (none prism) on the Leica 400 and 500 series. By default the Leica range of Builders default setting is to use the Reflector. One of the main things you will have to do on the Total Station is to switch between using the reflector and using the laser (this allows you to measure to any point that is not the reflector on a wall for instance). To switch modes, do a long press on the button indicated below (f) the indicator (g) will be red if you are set on the laser and white if you are set on the reflector.

Switching between Prism and Laser (none prism) on the Leica 100, 200 and 300 series. By default the Leica range of Builders default setting is to use the Reflector. One of the main things you will have to do on the Total Station is to switch between using the reflector and using the laser (thia allows you to measure to any point that is not the reflector on a wall for instance). To switch modes, do a long press on the button indicated below (f) the indicator (g) will be red if you are set on the laser and white if you are set on the reflector.