Circuit-Breakers for Motor Protection Series 8523/8

Similar documents
Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

8 Installation Equipment

Motor Protection Circuit Breaker Series 8146/5-V27

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fittings Series 6050

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Explosion Proof Audible Signal db(a) Series YA60

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Main. Device short name. Device application

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

GV2ME. Main. Device short name. Device application

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

GV2P05. Main. Device short name. Device application

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Type: DILM25 10(24V50HZ) Article No.:

High performance circuit breakers

Type: DILM12 10(24VDC) Article No.:

7 Lighting Technology

TeSys circuit-breakers

Bulletin 190 IEC Modular Starter System

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Explosion Proof Audible Signal db(a) Series YA60

A V 50Hz / V 60Hz

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

AS09..S 3-pole Contactors - Spring Terminals

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

C E R T I F I C A T E O F C O M P L I A N C E

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Series CT7N Bimetallic Overload Relays

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

PRINCIPLES AND APPLICATIONS

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Minicontactorrelay,2NO/2NC,DCoperated

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I Ex-protected connectors exlink I

Panel-mounting thermostats, type series EM

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Manual Motor Starter Specifcations

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

SMALL OIL SEALED PUMPS

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

Magnetic and Hydraulic-Magnetic Circuit Breaker

Datasheet - SRB-E-201ST

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Process Transmitter RMA 422

EXPlora. Introduction

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Selection table SITOP power supplies

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

3AH3 Vacuum Circuit-Breakers

DMP 331i / DMP 333i LMP 331 i

Features XT SC 012 B B A

Figure 1: Device components

Nessie Coils for VDH and VDHT valves

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Features XT SC 012 B B A

Magnecraft Power Relays

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Datasheet - SRB301LC 24VAC/DC

PRE Series 16 Amp Plugs and Sockets Increased Safety

Transcription:

> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting ranges www.stahl.de 03150E00 circuit-breakers are equipped with a permanently set short-circuit fast trip and a thermal overcurrent trip adjustable at the switch. ATEX / IECEx / GOST Zone 0 1 2 20 21 22 For use in x x WebCode 8523A Components for System Solutions /1

Circuit-breaker for Motor Protection - suitable for protection of increased safety motors up to 12.5 kw (400 V, AC-3) - permanently set short-circuit fast-trip - adjustable thermal overcurrent trip Setting range 0.1... 22.5 A Rated voltage Optional equipment 690 V AC 1 NO + 1 NC or 2 NO + 2 NC 08875E00 Under voltage trip or shunt trip Selection Table Version Circuit-breaker, enclosure size 1 Current adjustment range Auxiliary contacts Additional device Order number 0.1 A... 0.16 A without without 8523/81-01-000 0.16 A... 0.25 A without without 8523/81-02-000 0.25 A... 0.4 A without without 8523/81-03-000 0.4... 0.63 A without without 8523/81-04-000 0.63... 1.0 A without without 8523/81-05-000 1.0... 1.6 A without without 8523/81-06-000 1.6... 2.5 A without without 8523/81-07-000 2.5... 4.0 A without without 8523/81-08-000 4.0... 6.3 A without without 8523/81-09-000 6.3... 9.0 A without without 8523/81-10-000 9.0... 12.5 A without without 8523/81-11-000 12.5... 16.0 A without without 8523/81-12-000 16.0... 20.0 A without without 8523/81-13-000 20.0... 22.5 A without without 8523/81-14-000 Order Number Supplement Trip Undervoltage trip 8523/8.-..-1.. Shunt release 8523/8.-..-2.. Auxiliary facilities 1 auxiliary circuit switch 1NC+1NO 8523/8.-..-.2. 2 auxiliary circuit switch 2NC+2NO 8523/8.-..-.4. Voltage and 48 V AC, 50 Hz 8523/8.-..-1.3 frequency for trip 60 V AC, 50 Hz 8523/8.-..-1.4 110 V AC, 50 Hz 8523/8.-..-1.5 230 V AC, 50 Hz 8523/8.-..-1.6 400 V AC, 50 Hz 8523/8.-..-1.7 415 V AC, 50 Hz 8523/8.-..-1.8 500 V AC, 50 Hz 8523/8.-..-1.9 24... 60 V AC / DC 8523/8.-..-2.1 110... 240 V AC / DC 8523/8.-..-2.2 /2 Components for System Solutions

Selection Table Version Release Auxiliary contacts Order number Circuit-breaker, without 1 NC + 1 NO 8523/82-..-020 enclosure size 2 2 NC + 2 NO 8523/82-..-040 Undervoltage trip 1 NC + 1 NO 8523/82-..-12. 2 NC + 2 NO 8523/82-..-14. Shunt release 1 NC + 1 NO 8523/82-..-22. 2 NC + 2 NO 8523/82-..-24. Order Number Supplement Current adjustment 0.1... 0.16 A 8523/8.-01-... range 0.16... 0.25 A 8523/8.-02-... Voltage and frequency for trip Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Certificates and approvals Certificates 0.25... 0.4 A 8523/8.-03-... 0.4... 0.63 A 8523/8.-04-... 0.63... 1.0 A 8523/8.-05-... 1.0... 1.6 A 8523/8.-06-... 1.6... 2.5 A 8523/8.-07-... 2.5... 4.0 A 8523/8.-08-... 4.0... 6.3 A 8523/8.-09-... 6.3... 9.0 A 8523/8.-10-... 9.0... 12.5 A 8523/8.-11-... 12.5... 16.0 A 8523/8.-12-... 16.0... 20.0 A 8523/8.-13-... 20.0... 22.5 A 8523/8.-14-... 48 V AC, 50 Hz 8523/8.-..-1.3 60 V AC, 50 Hz 8523/8.-..-1.4 110 V AC, 50 Hz 8523/8.-..-1.5 230 V AC, 50 Hz 8523/8.-..-1.6 400 V AC, 50 Hz 8523/8.-..-1.7 415 V AC, 50 Hz 8523/8.-..-1.8 500 V AC, 50 Hz 8523/8.-..-1.9 24... 60 V AC / DC 8523/8.-..-2.1 110... 240 V AC / DC 8523/8.-..-2.2 IECEx BVS 08.0039 U Ex de IIC Ex de I DMT 01 ATEX E 153 U E II 2 G Ex de IIC E I M 2 Ex de I ATEX, IECEx, Canada (CSA), Belarus (GOST-B) Components for System Solutions /3

Technical Data Electrical data Rated operational voltage Rated working current Switching capacity Mechanical life Main contacts Short circuit protection Thermal overcurrent trip Electromagnetic fast trip Power dissipation Auxiliary contacts Device version Auxiliary contacts Rated voltage Rated current max. 690 V AC, 50 / 60 Hz 0.1... 22.5 A dependent on adjustment range dependent on adjustment range (AC) 230 V 400 V 500 V 690 V 7.0 kw 12.4 kw 16.0 kw 22.0 kw 10 5 operations 3-pole fuse U e (~V) AC-3 (kw) gg (A) I K (A) 220 / 230 7.0 20 ) 300 380 / 400 12.5 25 ) 400 35 ) 650 500 16.0 690 22.0 Adjustable at switch; dependent on adjustment range Adjustment range Threshold values set at factory 0.16... 0.63 A 7.5... 12.0 I n 1.0... 2.5 A 9.0... 14.0 I n 4.0... 6.0 A 10.0... 15.0 I n 9.0... 22.5 A 12.0... 17.5 I n max. 6.75 W Options: none; 1 NC + 1 NO; 2 NC + 2 NO max. 500 V AC AC-15 230 V 400 V 2 A 1 A DC-13 60 V 110 V 220 V 2.5 A 0.6 A 0.25 A Ambient conditions Ambient temperature -20... +40 C /4 Components for System Solutions

Technical Data Mechanical data Enclosure material Operating handle Weight Connection Undervoltage trip Function Electrical data Voltages Shunt release Function Electrical data Voltages Note Other features Epoxy resin or polyester resin on request 8523/81 1.4 kg 8523/82 1.8 kg Main contacts 1.5... 6 mm 2 flexible 1.5... 10 mm 2 solid Auxiliary contacts 0.75... 1.5 mm 2 flexible 0.75... 2.5 mm 2 solid When power is lost, circuit-breaker trips; this prevents unwanted restarting, e.g. of a motor possible rated actuating voltage U c 50 Hz: 48; 60; 110; 230; 400; 415; 500 V Pick-up 0.85... x U c Drop-out 0.7... 0.35 x U c for remote tripping of circuit-breakers by applying actuating voltage possible rated actuating voltage U c AC / DC: 24... 60 V, 110... 240 V Switches are suitable for protection of increased safety motors; Switch operated by rotary actuator; clearly visible position indication; Phase failure sensivity. Due to shortened switch grip, release is ensured even if mechanism is locked. Breaking parameter: can be used as MAIN or EMERGENCY OFF switch. If necessary accessories are fitted. Components for System Solutions /5

Trip Response Adjustment range of motor protection switch Trip time of motor protection switch at 3 4 5 6 7.2 8 times the setting current, 3-pin, from cold state. A... A s s s s s s 0.1... 0.16 15.0 9.0 6.5 4.8 3.7 3.2 0.16... 0.25 16.0 10.0 6.8 5.2 4.0 3.6 0.25... 0.4 16.0 9.7 6.5 5.0 3.8 3.3 0.4... 0.63 17.0 10.2 7.3 5.7 4.4 3.9 0.63... 1.0 17.5 10.2 7.2 5.5 4.2 3.8 1.0... 1.6 17.0 10.0 7.1 5.6 4.4 4.0 1.6... 2.5 18.0 10.3 7.5 5.9 4.7 4.2 2.5... 4.0 18.4 11.5 8.1 6.4 5.0 4.6 4.0... 6.3 19.0 12.0 8.5 6.7 5.3 4.9 6.3... 9.0 18.2 11.5 7.9 6.0 4.5 3.8 9.0... 12.5 19.0 11.5 8.0 6.0 4.6 4.0 12.5... 16.0 19.5 11.5 7.5 5.4 4.0 3.3 16.0... 20.0 20.0 11.5 7.8 5.7 4.2 3.5 20.0... 22.5 20.0 10.4 7.0 5.0 3.7 3.2 1) Multiples of the nominal current 2) Tripping time 3) 2-pole 4) 3-pole 5) Electromagnetic release 11050E00 11051E00 /6 Components for System Solutions

Trip Response 11052E00 11053E00 1) Multiples of the nominal current 2) Tripping time 3) 2-pole 4) 3-pole 5) Electromagnetic release 11054E00 11055E00 Components for System Solutions /7

Trip Response 11056E00 11057E00 1) Multiples of the nominal current 2) Tripping time 3) 2-pole 4) 3-pole 5) Electromagnetic release 11058E00 11059E00 /8 Components for System Solutions

Trip Response 11060E00 11061E00 1) Multiples of the nominal current 2) Tripping time 3) 2-pole 4) 3-pole 5) Electromagnetic release 11062E00 11063E00 Components for System Solutions /9

Accessories and Spare Parts Designation Illustration Description Art. no. Weight Jumper for undervoltage release, length 400 mm (two bridges required) kg 147121 0.019 04951E00 Dimensional Drawings (All Dimensions in mm ) - Subject to Alterations 8523/81 Circuit-breaker for motor protection, Module width 1, without auxiliary contacts 04324E00 8523/82 Circuit-breaker for motor protection, Module width 2, with auxiliary contacts 04323E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /10 Components for System Solutions