Inspire Station. Programming Guide. Software Version 3.0. Rev A

Similar documents
Control Console User Manual. Version 1.1.2

ETC Quick Guide. Source Four LED Profile

Control Console User Manual. Version 1.6

Relay Panel User Manual. Version 1.0

Yoke Safety cable loop. Up Light Bulb

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

Application Note #428 Revision A April 2012 Wired seetouchr QS Wallstation: Advanced Programming Mode

PRELIMINARY. Pro One-Cell Fixed. ArcSystem Series

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

Preset 10 Ethernet Interface Configuration & Owner s Manual

American DJ. Show Designer. Software Revision 2.08

ARCSYSTEM. Fully-dimmable LED lighting for auditoriums, retail and commercial installations. visual environment technologies etcconnect.

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

DSIM-GI Installation Guide Revision P

H A R D W A R E S O F T W A R E

Show Designer 3. Software Revision 1.15

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Best then, best now Source Four by ETC.

STX Stairs lighting controller.

ColorSource AV Console

SceneStyle2 User Guide

VERSION 2.A 10/21/1999. Lightronics Inc. 509 Central Drive, Virginia Beach, VA TEL

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

Conference Speaker Timing System. Operating Instruction Manual

Figure 1. MFP-3D software tray

Application Note #247 Revision E November 2014

ONSIGHT CONNECT FOR SMARTPHONES GUIDE

OPERATING MANUAL. including

ecast for IOS Revision 1.3

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

THE FROG SERIES OPERATING MANUAL

Manual Addendum For Rerun V1.1 software 12/12/2006, RERUN-A = Serial #06A068, RERUN-P = Serial #06A031

Chapter 23 Dimmer monitoring

Source Four LED ETC. Source Four LED Series. General information. Source Four LED Light Engine with Shutter Barrel. Source Four LED Light Engine Body

NETWORK COMPASS USER MANUAL CONTENTS

randomrhythm Bedienungsanleitung User Guide

ETC. Source Four LED Series. General information. Source Four LED Studio HD Light Engine with Shutter Barrel

Selador Series by ETC Lustr Paletta Vivid Vivid-R Vivid Fire Vivid Ice Pearl User Manual

EasyAir Philips Field Apps User Manual. May 2018

Copyright and Disclaimer

III Phrase Sampler. User Manual

Celect Communications. Complete TV Users Guide

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

Complete TV Users Guide

Operating Guide. ViewClix offers a revolutionary experience for seniors and their families and friends.

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

TABLE OF CONTENTS. 2 SGM Light Technology 23/08/1999 Ver. 2.00

Users Manual Firmware 3.03 May 9, 2018

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Users Manual Firmware 2.03 September 6, 2017

DSIM-AF Installation Guide Revision B

Casambi App User Guide

PRESET 10 ARCHITECTURAL OWNERS MANUAL

Whole House Lighting Controller

Contemporary III. Control your adjustable bed with your smart device using the remote mobile app

KNOBS. REPEATS Controls the feedback amount for the heads that have their feedback enabled. ECHO LEVEL

Quick Start Guide. Large-capacity Automatic Pet Feeder

INSTALATION PROCEDURE

DMX48. User s instruction manual. 24 Channel DMX controller

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

fxbox User Manual P. 1 Fxbox User Manual

MC 7516 MC 7524 MC 7516 / 7524 / 7532 MEMORY LIGHTING CONTROLLERS USER GUIDE

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

RELEASE NOTES. Introduction. Supported Devices. Mackie Master Fader App V4.5.1 October 2016

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

CN Remove the scanner assembly (X476 and X576 models) and all doors/covers.

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

VIBRIO. User Manual. by Toast Mobile

Element 78 MPE-200. by Summit Audio. Guide To Operations. for software version 1.23

Controller DMX DC-1224

CONTENT Product Introduction... 2 Packing Configuration...3 Hardware Orientation... 4 Front Panel... 4 Back Panel... 6 Using Your Product... 7 Content

PRODUCT MANUAL. DMX BOSS Wi-Fi Controller. Product Description

GAUGEMASTER PRODIGY EXPRESS

Operation Manual (not in Cubase LE)

User Manual LivingColors Bloom

Setup. Connecting to a DMX Interface

Four Head dtape Echo & Looper

Mini Gear Indicator Manual SW024

2002 Martin Professional A/S, Denmark.

Troubleshooting Guide for E-Poll Book

Made for LEDs. Quick Start. Version 1.3 Software

User Guide. express yourself through light. Based on FW of 27

DMX DC User manual. DMX controller

ETC. D40 Studio. Selador Desire Series GENERAL INFORMATION ORDERING INFORMATION. Desire CE D40 Studio

PRESET 10 PORTABLE OWNERS MANUAL

SM DMX LIGHTING CONTROLLER OWNERS MANUAL. May 19, 2009

Special Applications Modules

TABLE OF CONTENTS. Rev. 9 2 Stage Designer 50

USER MANUAL AL-Control 1 PRO

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

Casambi App FAQ. Version Casambi Technologies Oy.

Rako App Guide. A Rako lighting system can be controlled by the App if the system meets the following requirements:

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

The ATT Deluxe Receiver

SCENEMASTER 3F QUICK OPERATION

RERUN ARCHITECTURAL DMX512 RECORDER OWNERS MANUAL

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

PSC300 Operation Manual

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

Transcription:

Inspire Station Programming Guide Software Version 3.0 Rev A Copyright 2016 Electronic Theatre Controls, Inc. All rights reserved. Product information and specifications subject to change. Part Number: 7186M1220-3.0.0 Rev: A Released: 2016-02

ETC, Unison Echo, and Inspire are registered trademarks of Electronic Theatre Controls, Inc. in the United States and other countries. All other trademarks, both marked and not marked, are the property of their respective owners. ETC intends this document, whether printed or electronic, to be printed in its entirety.

Table of Contents Introduction.........................1 Document Conventions...............................1 Help from ETC Technical Services...........................2 Overview...........................3 Station Configuration....................................4 Record/Program Mode................................4 Function switch......................................4 Rotary and DIP Switches..............................4 Function switch: Preset...................................4 Preset Toggle.......................................4 Use Off............................................5 Preset Mode Raise / Lower.............................5 Sequence Control....................................5 Function switch: Custom..................................6 With EchoAccess.....................................6 Without Echo Access.................................6 Function switch: Zone....................................6 Zone Selection......................................6 Zone Toggle........................................6 Zone Raise / Lower...................................7 Color Control Mode (4 button with fader station only).....8 Record/Program Mode................9 Program Zone Start.....................................10 Space Combine (4 button only)........11 Combining Spaces..................................11 Program Mode for Space Combine.....................11 Function Switch for Space Combine....................12 Appendix A Station Functionality.................13 1 Station.......................................14 Factory Defaults....................................14 Preset.............................................14 Zone.............................................15 Custom...........................................16 2 Station.......................................17 Factory Defaults....................................17 Preset.............................................17 Zone.............................................18 Custom...........................................19 4 Station.......................................20 Table of Contents i

Factory Defaults....................................20 Preset.............................................20 Zone.............................................21 Custom...........................................22 Space Combine in Preset.............................23 Space Combine in Zone..............................24 Space Combine in Custom............................25 4 with Fader....................................26 Factory Defaults....................................26 Preset.............................................26 Zone.............................................27 Zone with Color Control Enabled......................28 Custom...........................................29 6..............................................30 Preset.............................................30 Zone.............................................31 Custom...........................................32 8..............................................33 Preset.............................................33 Zone.............................................34 Custom...........................................35 Appendix B Station Miscellaneous................37 Remove or Install the Wall Plate..........................38 Remove Wall Plate..................................38 Install Wall Plate....................................38 Install Legends..................................39 Rotary Switch Assignments..............................40 DIP Switch Settings.....................................41 ii Inspire Station Programming Guide

Introduction Welcome to the Echo Inspire Station Programming Guide. This document will guide you in the programming and configuration of your Echo Inspire Stations, including the 1 button, 2 button, 4 button, 6 button, 8 button, and the 4 button with fader station. This guide is intended for use after station installation; therefore the content of this document is targeted at programming the configuration and features of the station only. For detailed information regarding installation, please reference the Echo Inspire Station Installation Guide available for download on the ETC website www.etcconnect.com. For detailed information regarding the configuration of the Inspire station using EchoAccess, reference the EchoAccess Mobile App integrated help system. Document Conventions This document uses the following convention to draw your attention to important information. Notes are helpful hints and information that is supplemental to the main text. ETC's user documents are designed for printed or electronic use. However, there are many advantages to using the electronic (.PDF) versions. In addition to the benefits of a PDF (such as word search, bookmarks, and commenting tools) you can click on headings in the Table of Contents and jump to the desired page. Throughout this document, any cross-references (indicated in blue italics like this: Introduction on page 1) are links that may be clicked to jump to the specific part of the manual. All of ETC's documents are available for free download from our website: www.etcconnect.com. Please email comments about this manual to: TechComm@etcconnect.com. Introduction 1

Help from ETC Technical Services If you are having difficulties programming your Inspire station, your most convenient resources are the references given in this document. To search more widely, try the ETC website at www.etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below. Emergency service is available from all ETC offices outside of normal business hours. When calling for help, please have the following information available: Detailed description of the problem and a listing of equipment in the system. Be near the equipment for troubleshooting Notification number if you have called in previously Americas United Kingdom Electronic Theatre Controls Inc. Electronic Theatre Controls Ltd. Technical Services Department Technical Services Department 3031 Pleasant View Road 26-28 Victoria Industrial Estate Middleton, WI 53562 Victoria Road, 800-775-4382 (USA, toll-free) London W3 6UU England +1-608 831-4116 +44 (0)20 8896 1000 service@etcconnect.com service@etceurope.com Asia Germany Electronic Theatre Controls Asia, Ltd. Electronic Theatre Controls GmbH Technical Services Department Technical Services Department Room 1801, 18/F Ohmstrasse 3 Tower 1, Phase 1 Enterprise Square 83607 Holzkirchen, Germany 9 Sheung Yuet Road +49 (80 24) 47 00-0 Kowloon Bay, Kowloon, Hong Kong techserv-hoki@etcconnect.com +852 2799 1220 service@etcasia.com 2 Inspire Station Programming Guide

Overview Unison Echo Inspire stations provide preset, zone, and space combine controls for use with Unison Echo and Sensor control systems only. Reference Station Functionality on page 13 for detailed information about each station type and its possible function settings, or download the Inspire Station data sheet located on the ETC website www.etcconnect.com for the complete listing including model and ordering information. This programming guide is provided to detail the basic functions of the Inspire stations. For more detailed information about the custom configuration options using EchoAccess, reference the EchoAccess Mobile App integrated help system. Overview 3

Station Configuration The Inspire station has on-board switch and button settings that are available from the front of the station when it is installed and the cover is removed. Record/Program Mode RECORD/ PROGRAM MODE The [RECORD/PROGRAM MODE] button provides access to record and program settings. The associated LED indicates mode status. Function switch PRESET CUSTOM ZONE Function switch The Function switch determines how the controls of the station function. It has behavior settings of Preset, Custom, and Zone. Rotary and DIP Switches Additional rotary and DIP switch settings are accessible on the rear of the station. These settings typically are made prior to final installation of the station. Reference Rotary Switch Assignments and DIP Switch Settings on page 40 for more information. Also reference the Echo Inspire Station Installation Guide for detailed information regarding these switches and settings. Function switch: Preset Setting the Function switch to Preset (the highest switch setting) on an Inspire station allows you to perform preset related actions such as preset toggle, Off, record (snapshot levels), space raise / lower, and sequence control (1 button station only). Preset Toggle Switches 1 - Use Off 2 - Amber LED Disable INSPIRE STATION 3 - Space Combine Mode 50mA @ 24VDC, CLASS 2, TYPE1 4 - Fade Time Override For use with Dimming and Relay Products 5 - Zone Color Control 8 - Restore Defaults LISTED INDUSTRIAL CONTROL EQUIPMENT 9Z49 ENERGY MGMT. EQUIP Preset toggle control functionality allows you to toggle the preset on and off by pushing the assigned preset button or fader knob. A single button push activates / deactivates the preset that is assigned to that button using a two second fade time. A double button push activates / deactivates the preset that is assigned to that button using a 1/2 second fade time. A double-tap of any preset button will toggle the configured preset using a 1/2 second fade time for quick preset recall and deactivate. Address Space rear of station (4 button with fader shown) When a preset is active, the button LED lights blue to indicate its active state. If preset levels are altered while the preset is still active, the related button LED will return to its default state, either off or amber. Reference DIP Switch Settings on page 41. 4 Inspire Station Programming Guide

Use Off Use Off functionality enables the last button on the station with a dedicated space off action. A single push of the Off button will set the level of all zones to zero using a 2 second fade time. A double push of the Off button will set the level of all zones to zero using a 1/2 second fade time. Use Off functionality is enabled when DIP switch 1 is set to On. Reference DIP Switch Settings on page 41. The 1 button station does not recognize Use Off functionality. Reference DIP Switch Settings on page 41. Preset Mode Raise / Lower Raise and lower levels for all zones in the space using the assigned station buttons or fader knob (determined by the station type). Reference the appendix for the station type you are configuring for complete details. Push and hold the assigned raise / lower station button to raise or lower the intensity level of all zones in the space. Rotating the fader knob will raise or lower the intensity level of all zones in the space. Sequence Control Sequence control is available using the 1 button station in conjunction with ETC power control products that support sequences. DIP switch 1 must be set to the On position to enable sequence mode. For more information see DIP Switch Settings on page 41. In sequence mode, pressing the station button will toggle the sequence for the selected space (i.e. activate the sequence if it is inactive or deactivate it if it is active). Reference the related power control product user documentation for the products in your system for more information. Overview 5

Function switch: Custom Setting the Function switch to Custom (the middle switch setting) allows for varied features either with or without EchoAccess, although the presence of EchoAccess in the control system allows for an expanded feature set for Inspire stations. With EchoAccess EchoAccess provides complete customization of the Inspire station when it is in Custom control mode. For more information on the configurable device parameters and actions available, reference the EchoAccess Mobile App integrated help system. Changes made in EchoAccess impact the Custom Function switch setting of the Inspire stations only. Preset and Zone Function switch settings remain unaffected by changes made while using EchoAccess configuration tools. Without Echo Access By default the Custom Function switch setting on an Inspire station provides behavior that extends the Zone Function switch setting behaviors for control of more Zones. For example, on an 8 button station, Zone control mode defaults to zones 1 through 6. Setting the station in Custom control mode, by default, provides access to zones 7 through 12. Function switch: Zone Setting the Function switch to Zone (the lowest switch setting) on an Inspire station allows you to manually control the level of a zone using on / off and raise / lower functionality. When the station is placed in Zone control mode, the raise level button LED lights in dim blue and the lower level button LED lights in dim amber. This button assignment is determined by the station type. See Station Functionality on page 13. Zone Selection Zone selection allows the control of individual zones using raise / lower functionality. Zone selection is only available for the 4, 6, 8 and 4 button with fader stations. The 1 and 2 button stations are single zone control only. While the Function switch is set to Zone, the station provides visual indication of its current zone selection with backlit button LEDs. When a zone is un-selected the associated button will have no LED indication. To select a zone, push the Zone button. The button will illuminate in blue to indicate selection. Once a zone is selected, raise / lower functionality for only that zone is possible. Reference Zone Raise / Lower for more information. Zone Toggle While the Function switch is set to Zone, the station allows you to toggle the zone on and off most commonly by double-tapping the Zone button. The controlled zone level raises to full or toggles off using a 1/2 or 2 second fade time, depending on the station type. Reference Station Functionality on page 13 for more information. 6 Inspire Station Programming Guide

Space Toggle (4 button with fader station only) With no zones selected, toggle the levels for all zones in the space using the fader knob. A single push of the fader knob toggles all zone levels in the space to full or off, depending on the current state of the space, using a 2 second fade time. A double-tap of the fader knob toggles all zone levels in the space to full or off, using a 1/2 second fade time. A double-tap of any Zone button will toggle the configured zone using a 1/2 second fade time for quick access to lighting level extents. Zone Raise / Lower Raise and lower the selected zone level using the assigned raise and lower station controls. Each station type has configured raise and lower controls. Reference Station Functionality on page 13 for the station type you are configuring for complete details. Control With a Zone Selected The selected zone button LED lights blue to indicate its active state. A single push of the raise or lower button increments/decrements the level. Push and hold the raise or lower button to fade the level gradually. A double-tap of the raise or lower button toggles the level to full or off in a 1/2 second fade. With No Zone Selected With no zone selected, raise and lower button functionality modifies the intensity level for all zones in the space. A single push of the raise or lower button increments/decrements the intensity level for all zones in the space. Push and hold the raise or lower button to fade the level gradually, altering the intensity level for all zones in the space. A double-tap of the raise or lower button toggles the intensity level to full or off for all zones in the space, using a 1/2 second fade. Fader knob (4 button with fader station only) With a Zone Selected With a zone selected, the selected zone button LED lights blue to indicate its active state. Use the fader knob to raise / lower the selected zone intensity. A clockwise rotation of the fader increases zone intensity. A counter-clockwise rotation decreases zone intensity. Overview 7

The fader knob indicates with a blue LED halo the zone intensity level as it is raised and lowered. A level at full will indicate with a complete halo around the fade knob Levels between full and 1% indicate proportionately When the level is off (level zero), no halo shown but an amber LED illuminates at the 6 oclock position. With No Zone Selected With no zone selected, the fader knob modifies the intensity for all zones in the space. Color Control Mode (4 button with fader station only) Color Control functionality allows the Inspire 4 button with fader station to control patched LED zones on an Echo DMX Scene Controller. This setting only applies then the Function switch is set to Zone. Color Control mode does not affect the station when the Function switch is set to Preset or Custom. Reference the DMX Scene Controller Installation Guide for more information on setup. To enable Color Control on a 4 button with fader station, set DIP switch 5 On and set the Function switch to Zone. With a Color Zone Selected With a color zone selected, the selected zone button LED lights blue to indicate its active state. Use the fader knob to modify the selected zone intensity, saturation, and hue. The fader button in Color control mode has three control states that are cycled through with each press of the fader button. The station starts in Intensity mode, press the fader knob to progress through each additional mode. Intensity Mode A clockwise rotation of the fader increases zone intensity. A counter-clockwise rotation decreases zone intensity. As the intensity increases or decreases, the fader knob halo indicates intensity level. Saturation Mode A clockwise rotation of the fader increases zone color saturation. A counter-clockwise rotation decreases zone color saturation (fully de-saturated is white light). Saturation mode has a 0-100% range. As the saturation increases or decreases, the fader knob halo indicates its level. Hue Mode Rotation of the fader changes the hue of the zone color. Hue mode has a 0-360 degree range. As the hue increases or decreases, the fader knob halo indicates its position. Considering a color wheel, red would be at the 12 o clock position. 8 Inspire Station Programming Guide

Record/Program Mode Program mode allows adjustment of the consecutive range of presets and zones assigned to the station by allowing you to set the starting preset or zone, respectively. Enter Program mode by pressing and holding the [Record / Program Mode] button for three seconds. The Function switch determines whether edits are made to the consecutive range of presets or zones. Program adjustment is not available while in Custom Mode. In the case of the 4 button station, the DIP switch selection also determines what is programmed to the station. Record allows snapshot of all current output levels into the designated preset for playback. Reference Record Preset on page 9. Program mode only affects station behaviors when the Function switch is set to Preset or Zone, and does not affect Custom. Program Preset Start Step 1: Step 2: Step 3: Step 4: Set the station Function switch to its highest position of Preset. Press and hold the [Record / Program Mode] button for three seconds to enter Program mode. The Mode LED illuminates (steady amber) and the first preset button LED for the station flashes the current (first) preset controlled. (For example, if the first preset controlled is preset 3, the button LED will flash 3 times.) Push any station button to increase the starting preset number by one, the count always begins at 1. The station will update the LED indication, flashing the LED to reflect the new preset number. (For example, pushing the station button eight times will set the first preset for the station to preset 8). All station preset controls will be consecutively assigned beginning with the specified count. When the desired preset number is set, press and release the [Record / Program Mode] button to save the new setting. The Mode LED turns off and the station LEDs will display the new setting before returning to normal operation. To change the preset button assignment to a lower number than what is currently set, exit Program Mode then reenter Program Mode and the preset count will restart at 1. Record Preset Inspire stations provide recording (snapshot) of presets using the current output levels for the controlled zones in the space. The station must be set up for Preset control prior to recording. Step 1: Step 2: Press the [Record / Program Mode] button, an amber LED will blink during a 10 second record period. Push the button of the preset control you would like to record (snapshot). This stores current levels to the designated preset, exits record mode, and activates the newly recorded preset. Record/Program Mode 9

Program Zone Start Step 1: Step 2: Step 3: Step 4: Set the Function switch to its lowest position of Zone. Press and hold the [Record / Program Mode] button for three seconds to enter Program mode. The Mode LED illuminates (steady amber) and the first zone control button LED flashes the current (first) zone controlled. (For example, if the first zone controlled is zone 5, the button LED will flash 5 times.) Push any station button to increase the starting zone number by one, the count always begins at 1. The station will update the LED indication, flashing the LED to reflect the new zone number. (For example, pushing the station button three times will set the first zone for the station to zone 3). All station zone controls will be consecutively assigned beginning with the specified count. When the desired zone number is set, press and release the [Record / Program Mode] button to save the new setting. The Mode LED turns off and the station LEDs will blink the new setting before returning to normal operation To change the zone button assignment to a lower number than what is currently set, exit Program Mode then reenter Program Mode. The steps of exiting and reentering programming mode start the zone start count back to 1. 10 Inspire Station Programming Guide

Space Combine (4 button only) Placing the 4 button station (model # E1004) in space combine mode, accomplished by setting DIP switch 3 On, allows for combined control of multiple spaces. For more information on DIP switch settings, see DIP Switch Settings on page 41. In space combine mode, the zones with the same number but in different spaces will respond identically when the spaces are combined. For example, consider a divisible meeting room with four spaces. Each space contains a number of independently controlled zones and control stations. Space 1: Zone 1 Zone 2 Space 3: Zone 1 Zone 2 1 2 3 4 Space 2: Zone 1 Zone 2 Space 4: Zone 1 Zone 2 A 4 button station in space combine mode will control functionality changes as the room configurations change. The spaces that combine are determined by the function of the station, either Preset or Zone control. Before space combine functionality is possible, your connected system must have all of the spaces configured that you want to combine. In the example above, the system must be configured with four spaces in order to effectively combine their controls.. Combining Spaces To combine control for spaces, push the button with the desired combination of spaces. Multiple combinations can be activated to control larger spaces. For instance if the button to combine 1 and 2 is pushed and the button to combine 2 and 3 is also pushed, then the controls for space 1, 2, and 3 will all function together to control the entire combined space and space 4 would be controlled separately. The last button combines the last space with the first when the Function switch is set to Preset. When in Zone control mode, the last button on the station will combine control with the next space. Reference pages 23-25 for information about space combine actions on the 4 button station. Program Mode for Space Combine Program mode behaves in a slightly different manner when the 4 button station is set to space combine mode. Step 1: Press and hold the [Record / Program Mode] button for three seconds to enter Program mode. The Mode LED illuminates (steady amber) and the first space combine button LED flashes the current (first) space controlled. (For example, if the first combined space pair is space 3 & 4, the button LED will flash 3 times.) Step 2: Push any station button to increase the starting space combine pair number by one, the count always begins at space 1. The station will update the LED indication, flashing the Space Combine (4 button only) 11

Step 3: LED to reflect the new starting space pair number. (For example, pushing the station button eight times will set the first combined space pair for the station to spaces 8 and 9). All station combined space pairs will be consecutively assigned to the controls beginning with the specified count. When the desired space combine pair is set, press and release the [Record / Program Mode] button to save the new setting. The Mode LED turns off and the station LEDs will display the new setting before returning to normal operation. To change the space combine pair assignment to a lower number than what is currently set, exit Program Mode then reenter Program Mode and the count will restart at 1. Function Switch for Space Combine The Function switch affects how the last button on the station behaves. Function switch: Preset 3 & 4 4 & 5 5 & 6 6 & 3 When the Function switch is set to Preset, the last button on the station will combine the last space with the first space assigned to the station. Function switch: Zone 3 & 4 4 & 5 5 & 6 6 & 7 When the Function switch is set to Zone, the last button on the station will combine control for the next sequential space. 12 Inspire Station Programming Guide

Appendix A Station Functionality This appendix contains the following sections: 1 Station........................................ 14 2 Station........................................ 17 4 Station........................................ 20 4 with Fader..................................... 26 6.............................................. 30 8.............................................. 33 Station Functionality 13

1 Station The 1 button Inspire station offers control of a single preset or zone as determined by the Function switch setting. Factory Defaults The 1 button Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. All DIP switches are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, Preset 1 is the default. With the Function switch set to Zone, Zone 1 is the default. The 1 button station supports the following button actions: Push 1 Toggle Preset 1 or *Toggle Sequence When DIP switch 1 is On and the station Function switch is set to Preset, Sequence toggle mode is enabled (available on the 1 button station only). This feature allows the button to toggle the sequence associated in the configured space. Reference DIP Switch Settings for more information about DIP switches. Hold 1 Space raise Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. 1 Toggle Preset 1 14 Inspire Station Programming Guide

Zone The 1 button station supports the following button actions: Push 1 Toggle Zone 1 Hold 1 Zone 1 raise Double-tap Double-tap the button to toggle the zone to its full or off, using a 1/2 second fade time. 1 Toggle Zone 1 Station Functionality 15

Custom The 1 button station provides the following button actions: Push 1 Toggle Zone 2 Hold 1 Zone 2 raise Double-tap Double-tap the button to toggle the zone to its full or off, using a 1/2 second fade time. 1 Toggle Zone 2 These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. 16 Inspire Station Programming Guide

2 Station The 2 button Inspire station offers control of two presets or 1 zone as determined by the Function and DIP switch settings. Factory Defaults The 2 button Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. DIP switch 1 is set to On, for Use Off functionality. All others are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, Preset 1 is the default starting preset. With the Function switch set to Zone, Zone 1 is the default starting zone. The 2 button station supports the following button actions: Push 1 2 Toggle Preset 1 *Off or toggle Preset 2 Hold 1 2 Space raise Space lower Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. 1 2 Toggle Preset 1 *Off or toggle Preset 2 DIP switch 1 is set to On by factory default, which reserves button 2 on the station for Off functionality. Reference DIP Switch Settings on page 41 for instructions to change this default setting. Station Functionality 17

Zone The 2 button station supports the following button actions: Push 1 2 Zone 1 raise Zone 1 lower Hold 1 2 Zone 1 raise Zone 1 lower Double-tap Double-tap the button to toggle the zone to its extents using a 1/2 second fade time. 1 2 Zone 1 to full Zone 1 to 0% 18 Inspire Station Programming Guide

Custom The 2 button station provides the following button actions: Push 1 2 Zone 2 raise Zone 2 lower Hold 1 2 Zone 2 raise Zone 2 lower Double-tap Double-tap the button to toggle the zone to its extents using a 1/2 second fade time. 1 2 Zone 2 to full Zone 2 to 0% These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. Station Functionality 19

4 Station The 4 button Inspire station offers control of four presets or two zones, or space combine actions for up to five consecutive spaces as determined by the Function and DIP switch settings. Factory Defaults The 4 button Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. DIP switch 1 is set to On, for Use Off functionality. All others are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, Preset 1 is the default starting preset. With the Function switch set to Zone, Zone one 1 is the default starting zone. The 4 button station supports the following button actions: Push Toggle Preset 1 2 3 4 Toggle Preset 2 Toggle Preset 3 *Off or toggle Preset 4 Hold Space raise 2 3 4 Space raise Space lower Space lower Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. Toggle Preset 1 2 3 4 Toggle Preset 2 Toggle Preset 3 *Off or toggle Preset 4 20 Inspire Station Programming Guide

Zone The 4 button station supports the following button actions: Push Raise selection 2 3 4 Select Zone 1 Select Zone 2 Lower selection Hold Raise selection 2 3 4 Select Zone 1 Select Zone 2 Lower selection Double-tap Double-tap the button to toggle the zone to its extents using a 1/2 second fade time. Selection to full 2 3 4 Zone 1 toggle Zone 2 toggle Selection to 0% With No Zone Selected When no zone is selected, the raise selection and lower selection buttons (1 and 4) change the levels for the configured space. A double-tap on the raise selection and lower selection buttons (1 and 4) changes the levels for the configured space to their extents, using a 1/2 second fade time. Station Functionality 21

Custom The 4 button station supports the following button actions: Push Raise selection 2 3 4 Select Zone 3 Select Zone 4 Lower selection Hold Raise selection 2 3 4 Select Zone 3 Select Zone 4 Lower selection Double-tap Double-tap the button to toggle the zone to its extents using a 1/2 second fade time. Selection to full 2 3 4 Zone 3 toggle Zone 4 toggle Selection to 0% These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. 22 Inspire Station Programming Guide

Space Combine in Preset Setting the Function switch to Preset, with DIP switch 3 On, enables space combine mode on the 4 button station. The 4 button station in Space Combine mode supports the following button actions: Push Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 1 Hold Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 1 Double-tap is not a supported feature in Space Combine mode. When the 4 button station in Space Combine mode, and the Function switch is set to Preset, the spaces will wrap, meaning the last button on the station will combine with the first space configured for control on the station. All combine actions are toggles (essentially wall toggles), that both combine and un-combine the specified spaces. Station Functionality 23

Space Combine in Zone Setting the Function switch to Zone, with DIP switch 3 On, enables Space Combine mode on the 4 button station. The 4 button station in Space Combine mode supports the following button actions: Push Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 5 Hold Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 5 Double-tap is not a supported feature in Space Combine mode. 24 Inspire Station Programming Guide

Space Combine in Custom Setting the Function switch to Custom, with DIP switch 3 On, enables Space Combine mode on the 4 button station. The 4 button station in Space Combine mode supports the following button actions: Push Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 1 Hold Combine 1 & 2 2 3 4 Combine 2 & 3 Combine 3 & 4 Combine 4 & 1 Double-tap is not a supported feature in Space Combine mode. These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. Station Functionality 25

4 with Fader The 4 button with fader Inspire station offers control of up to five presets or four zones as determined by the Function and DIP switch settings. Factory Defaults The 4 button with fader Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. DIP switch 1 is set to On for Use Off functionality. All others are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, the fader knob is Preset 1. With the Function switch set to Zone, Zone 1 is the starting zone. The 4 button with fader station supports the following button actions: Push Toggle Preset 2 Toggle Preset 4 *Off or toggle Preset 1 2 3 4 5 1 Toggle Preset 3 Toggle Preset 5 Rotate clockwise - space raise Rotate counter-clockwise - space lower Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. Toggle Preset 2 Toggle Preset 4 *Off or activate / deactivate Preset 1 2 3 4 5 1 Toggle Preset 3 Toggle Preset 5 Rotate clockwise - space raise Rotate counter - space lower When DIP switch 1 is set to On, the 4 button with fader station uses the fader knob (push action) for Off functionality. *Push the fader knob to execute an Off command anytime presets or zones are On in the same space, otherwise the action toggles Preset 1. Reference DIP Switch Settings on page 41 for instructions to change this default setting. 26 Inspire Station Programming Guide

Zone The 4 button with fader station supports the following button and fader actions: Push Select Zone 1 Select Zone 3 *Selection toggle 2 3 4 5 1 select Zone 2 Select Zone 4 Rotate clockwise - raise selection Rotate counter - lower selection Hold Select Zone 1 Select Zone 3 2 3 4 5 1 Select Zone 2 Select Zone 4 Rotate clockwise - raise selection Rotate counter - lower selection Double-tap Double-tap the button or fader knob to toggle the zone or space using a 1/2 second fade time. Toggle Zone 1 Toggle Zone 3 *Selection toggle 2 3 4 5 1 Toggle Zone 2 Toggle Zone 4 Rotate clockwise - space raise Rotate counter - space lower *Push the fader knob to execute an Off command anytime presets or zones are On in the same space, otherwise the action toggles the space. With No Zone Selected When no zone is selected, rotate the fader knob to perform a space raise lower, changing all zone levels for the configured space. Double-tap on the fader knob to change the zone levels for the configured space to their extents, using a 1/2 second fade time. Station Functionality 27

Zone with Color Control Enabled With the Function switch set to Zone, and Color Control is enabled by setting DIP switch 5 On, the 4 button with fader station supports the following fader actions: Intensity Mode Select Zone 1 Select Zone 3 *Change Mode 2 3 4 5 1 select Zone 2 Select Zone 4 Rotate clockwise - raise intensity Rotate counter - lower intensity Saturation Mode Select Zone 1 Select Zone 3 *Change Mode 2 3 4 5 1 select zone 2 Select Zone 4 Rotate clockwise - raise saturation Rotate counter - lower saturation Hue Mode Select Zone 1 Select Zone 3 *Change Mode 2 3 4 5 1 select Zone 2 Select Zone 4 Rotate clockwise - raise hue Rotate counter - lower hue *Push the fader knob to change the Color Control mode from intensity, to saturation, then hue. With No Zone Selected When no zone is selected, rotate the fader knob to perform space wide commands, changing all zone levels for the configured space. 28 Inspire Station Programming Guide

Custom The 4 button with fader station supports the following button and fader actions: Push Select Zone 5 Select Zone 7 *Selection toggle 2 3 4 5 1 select Zone 6 Select Zone 8 Rotate clockwise - raise selection Rotate counter - lower selection Hold Select Zone 5 Select Zone 7 2 3 4 5 1 Select Zone 6 Select Zone 8 Rotate clockwise - raise selection Rotate counter - lower selection Double-tap Double-tap the button or fader knob to toggle the zone or space using a 1/2 second fade time. Toggle Zone 5 Toggle Zone 7 *Selection toggle 2 3 4 5 1 Toggle Zone 6 Toggle Zone 8 Rotate clockwise - space raise Rotate counter - space lower *Push the fader knob to execute an Off command anytime presets or zones are On in the same space, otherwise the action toggles the space. These are the default button and fader actions for Custom control mode. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. Station Functionality 29

6 The 6 button Inspire station offers control of up to six presets or four zones as determined by the Function and DIP switch settings. Factory Defaults The 6 button Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. DIP switch 1 is set to On for Use Off functionality. All others are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, Preset 1 is the default starting preset. With the Function switch set to Zone, Zone 1 is the default starting zone. The 6 button station supports the following button actions: Push Toggle Preset 1 Toggle Preset 2 Toggle Preset 4 Hold Space raise Space raise Space lower 1 2 3 4 5 6 1 2 3 4 5 6 Toggle Preset 3 Toggle Preset 5 *Off or toggle Preset 6 Space raise Space lower Space lower Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. Toggle Preset 1 1 Toggle Preset 2 2 3 Toggle Preset 3 Toggle Preset 4 4 5 6 Toggle Preset 5 *Off or toggle Preset 6 When DIP switch 1 is set to On, button 6 is designated for Off functionality. Reference DIP Switch Settings on page 41 for instructions to change this default setting. 30 Inspire Station Programming Guide

Zone The 6 button station supports the following button actions: Push Raise selection Select Zone 1 Select Zone 3 Hold Raise selection Select Zone 1 Select Zone 3 1 2 3 4 5 6 1 2 3 4 5 6 Select Zone 2 Select Zone 4 Lower selection Select Zone 2 Select Zone 4 Lower selection Double-tap Double-tap the button to toggle the selected zone or space using a 1/2 second fade time. Selection to full Zone 1 toggle Zone 3 toggle 1 2 3 4 5 6 Zone 2 toggle Zone 4 toggle Selection to 0% With No Zone Selected When no zone is selected, the raise and lower buttons (1 and 6) perform a space raise and space lower, changing all zone levels for the configured space. A double-tap on the raise or lower button changes the zone levels for the configured space to their extents, using a 1/2 second fade time. Station Functionality 31

Custom The 6 button station supports the following button actions: Push Raise selection Select Zone 5 Select Zone 7 Hold Raise selection Select Zone 5 Select Zone 7 1 2 3 4 5 6 1 2 3 4 5 6 Select Zone 6 Select Zone 8 Lower selection Select Zone 6 Select Zone 8 Lower selection Double-tap Double-tap the button to toggle the selected zone or space using a 1/2 second fade time. Selection to full Zone 5 toggle Zone 7 toggle 1 2 3 4 5 6 Zone 6 toggle Zone 8 toggle Selection to 0% These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. 32 Inspire Station Programming Guide

8 The 8 button Inspire station offers control of up to eight presets or four zones as determined by the Function and DIP switch settings. Factory Defaults The 8 button Inspire station ships from the factory in the following default settings: Preset Rotary switches are set to Address 1, Space 1. Reference Rotary Switch Assignments on page 40. All DIP switches are set to Off. Reference DIP Switch Settings on page 41. With the Function switch set to Preset, Preset 1 is the default starting preset. With the Function switch set to Zone, Zone 1 raise is the default starting zone. The 8 button station supports the following button actions: Push Toggle Preset 1 Toggle Preset 3 Toggle Preset 5 Toggle Preset 7 Hold 1 2 3 4 5 6 7 8 Toggle Preset 2 Toggle Preset 4 Toggle Preset 6 *Off or toggle Preset 8 Space raise Space raise Space lower Space lower 1 2 3 4 5 6 Space raise Space raise Space lower 7 8 Space lower Double-tap Double-tap the button to toggle the preset using a 1/2 second fade time. Toggle Preset 1 Toggle Preset 3 Toggle Preset 5 Toggle Preset 7 1 2 3 4 5 6 7 8 Toggle Preset 2 Toggle Preset 4 Toggle Preset 6 *Off or toggle Preset 8 When DIP switch 1 is set to On, the 8 button station uses button 8 for Off functionality. Reference DIP Switch Settings on page 41 for instructions to change this default setting. Station Functionality 33

Zone The 8 button station supports the following button actions: Push Zone 1 select Zone 3 select Zone 5 select Raise selection Hold Zone 1 select Zone 3 select Zone 5 select Raise selection 1 2 3 4 5 6 7 8 Lower selection 1 2 3 4 5 6 Zone 2 select Zone 4 select Zone 6 select Zone 2 select Zone 4 select Zone 6 select 7 8 Lower selection Double-tap Double-tap the button to toggle the selected zone or space using a 1/2 second fade time. Zone 1 toggle Zone 3 toggle Zone 5 toggle Selection to 0% With No Zone Selected 1 2 3 4 5 6 7 8 Zone 2 toggle Zone 4 toggle Zone 6 toggle Selection to Full When no zone is selected, the raise and lower buttons (7 & 8) perform a space raise and space lower, changing all zone levels for the configured space. A double-tap on the raise or lower button changes the zone levels for the configured space to their extents, using a 1/2 second fade time. 34 Inspire Station Programming Guide

Custom The 8 button station supports the following button actions: Push Zone 7 select Zone 9 select Zone 11 select Raise selection Hold Zone 7 select Zone 9 select Zone 11 select Raise selection 1 2 3 4 5 6 Zone 8 select Zone 10 select Zone 12 select 7 8 Lower selection 1 2 3 4 5 6 Zone 8 select Zone 10 select Zone 12 select 7 8 Lower selection Double-tap Double-tap the button to toggle the selected zone or space using a 1/2 second fade time. Zone 7 toggle Zone 9 toggle Zone 11 toggle Selection to 0% 1 2 3 4 5 6 7 8 Zone 8 toggle Zone 10 toggle Zone 12 toggle Selection to Full These are the default button actions for the station when the Function switch is set to Custom. For custom configuration using EchoAccess, reference the EchoAccess Mobile App integrated help system. Station Functionality 35

36 Inspire Station Programming Guide

Appendix B Station Miscellaneous This appendix contains the following sections: Remove or Install the Wall Plate........................... 38 Install Legends................................... 39 Rotary Switch Assignments............................... 40 DIP Switch Settings..................................... 41 Station Miscellaneous 37

Remove or Install the Wall Plate Remove Wall Plate After station installation is complete, to gain further access to the Record/Program Mode features and set the station Function switch, you must first remove the station wall plate. The wall plate is secured to the station with magnets that are attached to the wall plate. Step 1: Step 2: Using your index finger and thumb, lift the left and right side edges of the bottom of the wall plate, disengaging the magnets. The magnets that secure the wall plate are strong. You will need a good grip on the plate to lift it away. When the bottom of the wall plate is free from the magnets, continue lifting until the top of the plate is free from the tabs on the top of the station electronics assembly. Install Wall Plate Step 1: Step 2: Step 3: Step 4: Align the top of the wall plate to the station and angle the bottom approximately 20 degrees. Hook the top of the wall plate to the tabs located on the station electronics assembly. To ensure the wall plate is hooked properly on the top hook, wiggle it slightly side to side. Swing the bottom of the wall plate down until the magnets engage. If the wall plate does not fully attach automatically, wiggle the bottom of the plate until all of the magnets are seated properly to the station and the plate is secure. When installing a multi-gang wall plate to a station and the stations are not aligned properly in the back box, the wall plate will not attach properly. Loosen the screws that secure the station to the backbox, adjust each station to improve the alignment, secure the screws, then retry wall plate installation. 38 Inspire Station Programming Guide

Install Legends Inspire stations ship with standard button legends installed beneath a clear lens. An additional sheet of standard button legends are provided for field installation as needed. Customize and print your own button legends on standard transparency. Download the button legend template provided on the ETC website www.etcconnect.com. Each button can have a legend, installed beneath the button lens. To remove, install, or replace a button legend you must first remove the bezel and button lens from the station electronics. Step 1: Remove the bezel from the station electronics. Each corner of the bezel is provided with a notch to assist with bezel removal. Use your thumbnail to lift a corner free, then gently remove the bezel from the station. Step 2: Step 3: Remove the button lens. Using the pads of your thumbs, press on the lens and slide the lens either left or right, toward the button hinge points. Once the lens is removed, remove the existing legend and replace it with another standard legend, as provided with this station, or insert a custom legend. 7 Preset Step 4: Replace the lens onto the button by aligning the grooves of the lens to the button, then sliding the lens in place starting at the hinge. Slide the lens until it covers the entire button and clicks into place. Step 5: Replace the bezel to the station electronics when all legends and lenses are in place. Station Miscellaneous 39

Rotary Switch Assignments Two rotary switches on the rear panel of the station provide for station address and space assignment. Each station must be set to a unique station address for the assigned space. By default, these switches are set to station Address 1, Space 1. Events and commands are shared by all devices within an assigned space. 40 Inspire Station Programming Guide

DIP Switch Settings DIP switches on the rear panel of the station provide for advanced station functionality and local settings. Each station ships from the factory with a default DIP switch setting. Reference Station Functionality on page 13 for details about each station type and their related settings and factory defaults. ETC recommends that you reset power to the station after changing a DIP switch setting. Switch # Use When enabled, switch 1 provides Use Off functionality or Sequence toggle, depending on the station type. For the 2, 4, 6, 8 and 4 button with fader stations, setting switch 1 to On enables Use 1 Off for the last button on the station when in Preset mode. When this is set to Off, the Off function of the station is not provided. For the 1 button station, setting switch 1 On enables Sequence toggle. When enabled, places the station in Dark Station mode and amber LEDs on the station will 2 be disabled. The default switch setting is Off. This this default mode, the amber LEDs are illuminated so the station glows in darkened spaces, allowing it to be easily located. 3 4-button station only - changes the station functionality enabling space combine. Fade Time Disable - Applies a 0 second fade time to all station actions for non-dim switched 4 mode behavior (when dimming features are not wanted) 4 button with fader station only - changes the Zone mode (Function selection switch) of the 5 station into Color control mode. 6 future development 7 future development Restore to Defaults at boot. Setting this DIP switch, then cycling power to the station restores 8 the station to factory defaults. Set the DIP switch Off after the power has cycled. When the station Function switch is set to Custom, only DIP switch number 8 applies. All other DIP switch settings are ignored. Station Miscellaneous 41