Brown University. Communications Standard Parts List

Similar documents
Brown University Revised April 13, 2012 Facilities Design & Construction Standards SECTION COMMUNICATIONS PARTS

Follow The Leader In Shielded Technology

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

APPENDIX A Verify All Part Numbers (Partial List of Approved Products)

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

C. Link offers a standard 1-year warranty on all parts and labor. Manufacturer's warranty is available for larger projects.

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

Request for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Request for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Division 27 COMMUNICATION/DATA, PATHWAYS, AND WIRING

Keyed LC Connector Solution A LANscape Solutions Product

Information Technology Services DESIGN AND INSTALLATION STANDARDS

Preferred ordering guide for NETCONNECT

CABLING STANDARDS FOR

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Enterprise Networks. Comms Room and Backbone. in DETAIL

UNM IT/Telecommunications Guide Specification Labeling 11/07/

5400 Series Nonmetallic Raceway

High Performance Structured Cabling Products and Solutions. Product Catalog

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Mfgr. Berk Tek ea , Berk Tek ea , Berk Tek ea. Berk Tek ea ,350.

The Uniduct Nonmetallic Latching Raceway

Connected Solutions. April $ Post, 19 Rack ELERK1FR BK

SECTION COMMUNICATIONS HORIZONTAL CABLING

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

LTX Optical Distribution Panels. Ordering Guide

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

جامعة مؤتة العطاءات املركزية توريد وتركيب وتشغيل أجهزة شبكات/كلية الزراعة. Central Tenders Mu tah University

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

B. All work shall be in accordance with Building Industry Consulting Services International (BICSI) guidelines.

Telecommunications Cabling System Technical Specification for the K-12 Educational Environment Enhanced Category 5

blackbox.com/connect The smart choice when price matters most. Need help? Talk to a Black Box cable expert 24/7 at

Belden IBDN System 10GX 10GX Modules and 10GX Patch Panels

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable

Fiber Optics Redefined

SECTION COMMUNICATIONS HORIZONTAL CABLING

DATA/TELECOMMUNICATIONS REQUEST FOR PRICING

STRUCTURED CABLE SYSTEM (SCS)

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

SECTION COMMUNICATIONS HORIZONTAL CABLING

Cable Installation Tips

SC Connector. Fiber Optic Connectors. MDR Electronics

LGX Compatible (LSX) Connector Module) User Manual)

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

BLACK-BOX.EU/CONNECT

SOLICITATION ADDENDUM NO. 1 ITB THE FOLLOWING CHANGES TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED.

NGF optical distribution frame

Technical Specifications Florida Gulf Coast University

Optimax Field Installable Connectors and Installation Tool Kits

City of Winter Springs, FL

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting

6000 Series Patch Panel Terminating Instructions

Section Communications Optical Fiber Backbone Cabling

Uniprise. Quick Reference Guide.

SECTION 7 -- CROSS-CONNECT SYSTEMS

I/A Series Hardware Fiber Optic LAN Converter

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

Cable Installation Tips

Northwestern University Information Technology Building Infrastructure Requirements for Communication Facilities ( January 2010)

STANDARDS SECTION (16651) COMMUNICATIONS DISTRIBUTION SYSTEM (Rev. Jun 2011)

HighBand 25. TrueNet Category 6 Solutions

SECTION FIBER OPTIC STATION CABLES

Telecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components

Liberty Mutual Structured Cabling Specification Bid and Build Structured Cabling Technical Specification for:

Target Interface / Construction Compliance Inspection Checklist

Traditional RF Splitter/Combiner and Directional Coupler User Manual

CONNECT TO VALUE THE SMART CHOICE WHEN PRICE MATTERS MOST BLACK-BOX.EU/CONNECT

6.0 COPPER CONNECTIVITY. Category 6 Patch Panels. Applications. Category 6 Patch Panels. (6.2b) Category 6 Patch Panels

A. The requirements of Section govern the work specified in this section.

Best Friends General Trading FZE

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Broadband Connectivity System II

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Structured Cabling. Product Line Brochure

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

WaveTrax. Fiber Cable Management System

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Quality to fit your budget

Clarity Advanced Solutions6A

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

INSTALLATION INSTRUCTIONS FOR

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS Projector, Camera and Veteran s Project

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

Special Specification 6242 Special Fiber Optic Cable

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide

Small System Packages. Strand Dimming Systems

Transcription:

CIS - NTG Brown University Communications Standard Parts List All data installations must receive the 25-year Mission Critical Warrantee from Hubbell Premise Wiring. All fiber installations must receive Extended Warranty Program certification from Corning. This specification expires April 2010 FACEPLATES All faceplates shall be equipped with labels and label holders. Single gang 6 port faceplate shall be Hubbell P/N IFP16OW (Office White) Wall phone plates shall be recessed Hubbell P/N P630SR1GC6 MODULAR INSERTS Single Modular inserts for all data ports shall be Hubbell P/N HXJ6B (8-position blue universally wired category 6) Single Modular inserts for the voice port shall Hubbell P/N HXJUOW (6-pos USOC Office White) Blank Modular inserts shall be Hubbell P/N SFB10 Single Modular insert for Video shall be Hubbell P/N SFFX Modular inserts shall be positioned in the faceplate as follows starting at the top left: all voice jacks followed by all data jacks proceeding down the left column then down the right column. The first voice jack shall be named V1 in the tap list followed by V2. Data jacks shall ne named D1, D2, D3 and so forth in the tap list. 1 1 The tap list is a schedule of all cables in the project that lists the name of the communications outlet, the type of outlet, and destination communications room. Brown University Communication Specification 2009-2010 1 of 9

HORIZONTAL CABLE The UTP Horizontal cable utilized for the distribution of data shall meet or exceed Category 6 cable standards and shall comply with the Hubbell 25 year Mission Critical Warranty. Color shall be blue. Manufacturer shall be Mohawk P/N M57202B (non-plenum) P/N M57193B (plenum) The UTP Horizontal cable utilized for the distribution of voice, shall meet or exceed Category 6 cable standards and shall comply with the Hubbell 25 year Mission Critical Warranty.. Color shall be white.. Manufacturer shall be Mohawk P/N M56889B (non-plenum) P/N M56905B (plenum) The horizontal cable for video shall be 75 ohm, RG-6 Plenum rated Commscope P/N 2275V or approved equal DATA PATCH PANELS (Communications room) 48-port modular patch panel(s) shall be 8 position, 8 conductor, Category 6, manufactured by Hubbell P/N P6E48U 24-port modular patch panel(s), if approved, shall be 8 position, 8 conductor, Category 6, manufactured by Hubbell P/N P6E24U Use of a 24 port panel must be approved in writing by CIS. Horizontal wire management, when required, shall be manufactured by Hubbell P/N HC219ME3N FIBER OPTIC TERMINATION HARDWARE (Communications room) 72 Port Simplex Fiber Optic closet connector housing shall be Corning P/N CCH-04U 48 PORT Fiber Optic closet connector housing shall be Corning P/N CCH-02U 24 PORT Fiber Optic closet connector housing shall be Corning P/N CCH-01U 12 port fiber connector-housing panels for Multi mode fiber shall be Corning SC duplex panels P/N CCH-CP12-91 12 port fiber connector-housing panels for Single Mode shall be Corning SC duplex panels P/N CCH-CP12-59 Fiber optic horizontal manager shall be Corning P/N CJP-02U. Multi mode connectors shall be SC epoxy and polish, 900 µm boot, color navy blue manufactured by Corning P/N 95-100-48BP9N Single-mode connectors shall be SC epoxy and polish, 900 µm boot, color yellow manufactured by Corning P/N 95-250 08 BP9Y Brown University Communication Specification 2009-2010 2 of 9

VOICE TERMINATION HARDWARE (Communications Room) The 300 pair BIX mount shall be Nordx P/N QMBIX12E The 50 pair BIX mount shall be Nordx P/N QMBIX10C The 25 pair BIX connector shall be Nordx P/N QCBIX1A The 4 pair Bix connector shall be Nordx P/N QCBIX1A4 The Bix designation labels shall be Nordx. Label colors shall be GREEN Toward switch BLUE Toward telephone Building Entrance Terminals (BIX connectors IN and OUT with splice chamber): Manufactured by CIRCA o 25 pair- PN- 2100SB-25 o 50 pair- PN -2250SBP-50 o 100 pair- PN -2200SBP-100 Surge Protection Modules: Manufactured by CIRCA o PN- C3B1FS VIDEO TERMINATION HARDWARE (Communications room) The F connector utilized for the horizontal cable shall be manufactured by Gilbert P/N GF-6-AHS-USA Amplifiers, Directional couplers, and splitters shall be supplied and installed by Brown University s Communication Department. INTRA BUILDING BACKBONE CABLE The in -building backbone cables for voice shall be manufactured by ESSEX The in building backbone cable for data shall be a minimum of 12 strands single-mode and 12 stands multimode (62.5 micron) manufactured by Corning and installed by a Corning EWP certified vendor. Brown University Communication Specification 2009-2010 3 of 9

INTER BUILDING BACKBONE CABLES The Inter building backbone cable for voice shall be manufactured by Essex The Inter building backbone cable for data shall be manufactured by Corning and installed by a Corning EWP certified vendor. EQUIPMENT RACKS Ortronics Mighty Mo 10 Cable Management Rack: P/N OR-MM10716 Ortronics Mighty Mo Blank Filler Panels 1U P/N OR-401004788 2U P/N OR-401004789 3U P/N OR-401004790 4U P/N OR-401004791 Vertical Cable Management System Single Rack Line-Up Two Ortronics Mighty Mo Cable Management Cages with Door are required: P/N OR-MM6VMD706 The two Cable Management Cages for 7-foot racks are mounted at the front on each side These Cable Management Cages are attached to the rack directly on their near sides and with end support brackets on their far sides The doors open to either side as necessary Mulit-Rack Line-Up Two Ortronics Mighty Mo Cable Management Cages with Door (6-Inch) are required one each, on the left and right ends of the rack line-up: P/N OR- MM6VMD706 The two 6-inch Cable Management Cages for 7-foot racks are mounted at the front on the left and right sides, respectively, of the left-most and right-most rack in the line-up These Cable Management Cages are attached to their respective racks directly on their near sides and with end support brackets on their far sides The doors open to either side as necessary One Ortronics Mighty Mo Cable Management Cage with Door (12-Inch) is required between each adjoining rack: P/N OR-MM10VMD712 Brown University Communication Specification 2009-2010 4 of 9

The adjoining racks must be set exactly 8.5 inches apart so the 8.5-inch extrusion at the back of the 12-inch cage will fit between them The 12-inch Cable Management Cage is mounted directly to the front of the adjoining racks The door opens to either side as necessary Edge Network Electronics Supplied by CIS Cisco: P/N WS-3750-48P or other 1U model typical 1U 48-port PoE Edge Switch Cisco 3750 PoE maximum draw is 370 Watts Wireless Devices Supplied by CIS For inside: Aruba AP-65 Access Point http://www.arubanetworks.com/products/access-points/ap-65.php Aruba AP-65-MNT mounting kit For outside: Aruba AP-70 Access Point http://www.arubanetworks.com/products/access-points/ap-70.php Mounted inside close to the antenna on exterior Aruba AP-ANT-6 2.4/5.0Ghz, Wide Angle Angle 135 degree, SMA connector ap-ant-6_ss.pdf preferred antennae Aruba AP-ANT-9 2.4/7.0 Ghz, Bi Wide Angle 90 degree, SMA connector alternate antennae Uninterruptable Power Supply (UPS) Supplied by CIS American Power Conversion (APC): P/N SURTA3000RMXL3U APC Smart-UPS RT 3000VA Rack Tower 120V Rack Height 3U Net Weight 140 lbs. Online Thermal Dissipation 305 BTU Brown University Communication Specification 2009-2010 5 of 9

Input Connections NEMA L5-30P Cord Length 8 feet (2.44 meters) UPS Battery Pack American Power Conversion (APC): P/N SURT192RMXLBP3U Rack Height 3U Net Weight 200 lbs. RACK EQUIPMENT LAYOUT The standard network equipment rack is sized to hold six (6) patch panels or filler panels, 2U each one (1) 2U fiber patch panel and six (6) sets of 48-port Cisco 3750 PoE Edge Switch and 1U blank filler panel, or 2 U filler panels one 3U rack-mounted UPS and one (1) or two (2) 3U Battery Packs. The patch panel field begins with the top patch panel mounted at RUs 43 and 42 Additional patch panels, up to the rack maximum of six (6), shall be mounted immediately below the previous panel, without skipping RUs, with the sixth panel mounted at RUs 33 and 32 There are no horizontal cable management or blank filler panels to be placed between the patch panels The fiber LIU is mounted between the patch panels and electronics The edge switch field begins with a 1U blank filler panel at RU 31 Immediately below that filler panel, the first 1U edge switch is mounted at U30 Additional filler panel/edge switch pairs are added in order immediately below switch one (1), up to the rack maximum of six (6) pairs with the sixth switch mounted at RU 20 Empty rack units will be filled as necessary by panels sized to fit the rack switch count Dressing of Horizontal Distribution Cables All horizontal distribution cables to a single patch panel shall be dressed to one channel of the rack Cables to the various patch panels shall be dressed to alternate side channels, beginning with the right channel (facing the rear) for patch panel one. Brown University Communication Specification 2009-2010 6 of 9

Rack UPS Layout (One Battery Pack) - For one to three switches per rack The first 3U Battery Pack is placed through the rack until the front of the pack is even with the leading edge of the front angle support and rests directly on the front and rear angle supports Above the battery pack, the 3U UPS is mounted using the set of rack rails ordered with the UPS Total height of the UPS and Battery pack is 6U Blank filler panels are installed between the top of the UPS and the bottom of the lowest 3750 edge switch Rack UPS Layout (Two Battery Packs) - For four to six switches per rack The first 3U Battery Pack is placed through the rack until the front of the pack is even with the leading edge of the front angle support and rests directly on the front and rear angle supports The second 3U Battery Pack is placed through the rack and rests directly on the first battery pack Above the second battery pack, the 3U UPS is mounted using the set of rack rails ordered with the UPS Total height of the UPS and Battery pack is 9U Blank filler panels are installed between the top of the UPS and the bottom of the lowest 3750 edge switch A drawing of a typical rack with six switches is included at the end of this document. CABLE SUPPORTS / CABLE RACEWAY The Consulting Engineer shall specify Cable raceway and supports subject to approval by CIS. Snap in fittings for surface raceway may use a Wiremold adapter manufactured by Hubbell (A22) Furniture adapter plates are available for Steel case, Haworth, etc are available from Hubbell (A21) Brown University Communication Specification 2009-2010 7 of 9

OUTSIDE EMERGENCY PHONES Manufactured by Ramtel, Johnston, RI (www.ramtel.com) Micro Processor based hands free dual purpose phone with sealed chrome keypad & 4 auto dial buttons, Brown University stencil P/N RR734/3 Stainless steel Enclosure P/N 926 Heater/ clip on P/N 800-1072 24v transformer P/N 600-1011 Blinking blue light P/N BL-1A Free Standing stanchion 10'H x 10"W x 2"D ELEVATOR EMERGENCY PHONES Elevator phones shall be Ramtel P/N RR833 (If needed) Phone in Bezel Enclosure Ramtel P/N RR833-906 WHEELCHAIR LIFT PHONES One Button wheelchair assistance phone (on the lift) P/N RR733M Regular phone with Blue button for wheelchair lift (on each end of the lift) P/N RR734 Rev: June 17, 2009 Brown University Communication Specification 2009-2010 8 of 9

Brown University Communication Specification 2009-2010 9 of 9