Atomic-resolution Holography Electron Microscopic

Similar documents
3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

This work was supported by FINEP (Research and Projects Financing) under contract

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

DEVELOPMENT OF X-BAND KLYSTRON TECHNOLOGY AT SLAC

Defense Technical Information Center Compilation Part Notice

Monitor QA Management i model

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

Quadrupoles have become the most widely used

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Design Studies For The LCLS 120 Hz RF Gun Injector

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

Abstract. Keywords INTRODUCTION. Electron beam has been increasingly used for defect inspection in IC chip

Focused Ion Beam System MI4050

CATHODE-RAY OSCILLOSCOPE (CRO)

Semiconductors Displays Semiconductor Manufacturing and Inspection Equipment Scientific Instruments

Academic and Research Staff. Prof. John G. King Dr. John W. Coleman Dr. Edward H. Jacobsen. Norman D. Wittels

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Understanding & Optimising Scanning Electron Microscope Performance

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

SATRI AMPLIFIER AMP-51R. Owner s Manual

Detailed Design Report

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

SLAC R&D Program for a Polarized RF Gun

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

Application Note [AN-007] LCD Backlighting Technologies and Configurations

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Uniformity of Plasma Density and Film Thickness of Coatings Deposited Inside a Cylindrical Tube by Radio Frequency Sputtering

Linear Probe Encoder Page 1 of 7. Description. Features

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

Hamamatsu R1584 PMT Modifications

Nova NanoSEM Superior Imaging and Analytical Performance

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

AREAL- Phase 1. B. Grigoryan on behalf of AREAL team

Development of high power gyrotron and EC technologies for ITER

Development of OLED Lighting Panel with World-class Practical Performance

EPJ Web of Conferences 95,

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

The PEFP 20-MeV Proton Linear Accelerator

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Japan Completed Analog Switch Off in Terrestrial Television Broadcasting

A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

Elements of a Television System

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

Endurance Tests of Graphite Orificed Hollow Cathodes

Failure Analysis Technology for Advanced Devices

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Projectors EFFORTS FOR PROJECTOR QUALITY

CHAPTER 4 OSCILLOSCOPES

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

The Elettra Storage Ring and Top-Up Operation

Measurement of overtone frequencies of a toy piano and perception of its pitch

Operation Manual for. SCU1 Signal Conditioning Unit

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

RECENT PROGRESS IN UPGRADE OF THE HIGH INTENSITY THzzz zz-fel AT OzSAKzA UNIVERSITYzzzz

Laboratory for Ion Beam Interactions Facilities Overview. Damir Španja

An RF Excited Plasma Cathode Electron Beam Gun Design

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

S195AVGC-2BM 1.6x0.8mm, Red & Yellow Green LED Surface Mount Bi-Color Chip LED Indicator

These are used for producing a narrow and sharply focus beam of electrons.

Specification. EdiLex AC UFO Module 230V Series Datasheet 5ELACN2T23A ELACN2T23A ELACN2T23B Drawn Approval Approval

NMR. picospin. Maintenance Guide

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

TOSHIBA Industrial Magnetron E3328

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Colour Matching Technology

Improvements to Siemens Eclipse PET Cyclotron Penning Ion Source

HAPD and Electronics Updates

How to use and maintain survey meters and a personal digital dosimeter - Materials for explaining radiation measurement equipment and devices -

4.9 BEAM BLANKING AND PULSING OPTIONS

Present Status and Future Upgrade of KEKB Injector Linac

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

Physics of high-current diode

Photo cathode RF gun -

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

Preliminary Study on Radio Frequency Neutralizer for Ion Engine

MICROFOCUS X-RAY SOURCE PROJECT*

BY ADRIAN MESSER, UE Systems, Inc.

IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

Noise Detector ND-1 Operating Manual

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

bel canto SEP2 Single Ended Triode Tube Preamplifier User's Guide and Operating Information

Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows

CHAPTER 3 SEPARATION OF CONDUCTED EMI

RF Power Generation II

Specification. EdiLex AC Ultra-Low Flicker Module 230V Datasheet. Drawn Approval Approval

Screen investigations for low energetic electron beams at PITZ

Transcription:

SCIENTIFIC INSTRUMENT NEWS 2016 Vol. 7 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Article Atomic-resolution Holography Electron Microscopic Hiroyuki Shinada PhD, Principal Researche Basic Research Center Research and Development Group Hitachi, Ltd. Member, Japanese Society of Microscopy Member, Japan Society of Applied Physics Member, Society of Instrument and Control Engineers 1. Introduction The development of novel materials with revolutionary new properties and functionality requires measurements with atomic-scale resolution of the electromagnetic fields inside those materials, clarifying the quantum-mechanical phenomena responsible for material properties and functionality. To enable these investigations, we have developed a powerful tool: an ultra-high-voltage (1.2 MV) holography electron microscope. The holography electron microscope is a measurement instrument whose first successful practical application was achieved in 1978 by Dr. Akira Tonomura using a field-emission electron gun. 1,2) The accelerating voltage was subsequently increased to achieve higher resolution and to allow observations on thicker samples. In 2000, Hitachi and the university of Tokyo jointly developed the world s first ultra-high-voltage (1 MV) holography electron microscope 3) and used it to help clarify the superconductivity mechanism in high-temperature superconducting oxides. 4) The 10+ years since that breakthrough have witnessed major progress in the technology surrounding electron microscopy, and we have now exploited those technical advances to develop the ultimate holography electron microscope, achieving the world s highest resolution of 43 pm. This report surveys the development of this instrument. 2. An overview of the instrument and its four major technical challenges As shown in the schematic diagram in Figure 1, the atomic-resolution holography electron microscope is equipped with three tanks, in which are installed a 1.2 MV high-voltage generating circuit, a power supply for electron-gun control, and an electron gun and accelerator tube. Because high voltages (minus 1.2 MV) are applied to these pieces of equipment, they are stored in tanks filled with SF 6 (sulfur hexafluoride) gas to prevent electrical discharge. In addition, the high-voltage power supply is installed at a location separated from the main unit of the electron microscope to reduce the influence of the various types of noise it emits; the supply is connected to the main unit by a high-voltage cable. This basic structure is similar to that of the 1 MV ultra-high-voltage holography electron microscope completed in 2000; 3) however, to achieve the significantly increased resolution of the present instrument required overcoming four major technical challenges, as discussed below. Hitachi High-Technologies Corporation All rights reserved. 2016[46]

Fig.1 Overview of atomic-resolution holography electron microscope. This is a 1.2 MV ultra-high-voltage electron microscope using a three-tank scheme in which the high-voltage power supply is separated from the main unit in order to achieve high stability. The tanks are interconnected by high-voltage cables. 2-1 The world s first ultra-high-voltage electron microscope equipped with a spherical aberration corrector Optical microscopes use a combination of convex and concave lenses to correct spherical aberration in lenses. In electron microscopes, on the other hand, for many years it was not possible to exploit the functionality of concave lenses, and improvements in resolution were thus constrained by spherical aberration. Devices for correcting such aberration became available for practical use in 1995, 5) but extracting good performance from these devices required high stability from the electron microscope units on which they were mounted, and for this reason they were not installed on large-scale ultra-high-voltage electron microscopes. By surmounting the technical challenges described below to yield significant improvements in equipment stability, we succeeded in mounting a spherical aberration corrector on an ultra-high-voltage electron microscope for the first time in the world. 2-2 A 1.2 MeV electron beam with reduced energy fluctuations Energy fluctuations in an electron beam cause defocusing even in the presence of a spherical aberration corrector. For this reason, it is essential that an exceedingly stable voltage be used to accelerate the electron beam. Calculations indicated that, to attain a target resolution on the order of 40 pm, energy fluctuations in the electron beam would need to be kept below 0.6 ev while maintaining the high energy of 1.2 MeV. To improve the stability of the voltage used to accelerate the electron beam, we developed low-noise resistors with low temperature coefficients and a high-voltage cable equipped with noise-filtering capabilities. The 1.2 MV ultra-high-voltage power-supply system we developed boasted a stability of 3 10-7, approximately 70% greater than the stability of previous systems. Hitachi High-Technologies Corporation All rights reserved. 2016[47]

2-3 Electron gun capable of stable electron-beam emission over long periods of time In the 1 MV ultra-high-voltage electron microscope and other typical field-emission electron guns, a voltage (the extraction voltage) is applied to extract electrons, and the emitted electron current begins to decrease immediately after the start of electron emission. For this reason, when using machines of this type the extraction voltage must be adjusted once or twice per day. However, the trajectory of the electron beam shifts if only slightly each time the extraction voltage is adjusted, and for this reason it is not easy to operate the spherical aberration corrector under optimal opticalaxis conditions. We felt that we needed a field-emission electron gun that could be used without adjustment throughout a full day s observations. Although high-stability field-emission electron guns have been increasingly used for practical applications in recent years, we needed to advance this technology further, increasing the strength of the vacuum inside the electron gun to several times that found in the newest models; ultimately we developed an electron gun with an interior vacuum strength of 3 10-10 Pa (Pascals), some 100 times stronger than that for the 1 MV microscope developed in 2000 (Fig. 2). 8) Fig.2 High-stability, high-brightness electron gun Previous electron guns suffered from a decrease in electron emission immediately after the start of electron emission, requiring adjustment of the extraction voltage and other parameters, and consequential wait times for the system to stabilize. In this instrument, we used an ultra-high vacuum to ensure that the system is stable and ready to use from the moment of electron beam extraction. Hitachi High-Technologies Corporation All rights reserved. 2016[48]

2-4 Developing facility technologies to eliminate factors responsible for deterioration of resolution Successful atomic-scale observations require that both the electron beam and the measurement sample be isolated from external disturbances including vibrations, sound waves, and magnetic fields to the greatest possible extent. To suppress the effects of such disturbances, we constructed a dedicated building for our microscope; inside the experimental chamber we installed sound absorbers and implemented a precision temperature-control system. The performance of the resulting chamber exceeded our initial objectives: sound isolation and low-noise performance of 20 db (>200 Hz), floor vibrations of 7.2 10-4 cm/sec 2 at 100 Hz, and temperature stability of ±0.2 C / 8 hours (Fig. 3). 7) Fig.3 Electron microscope building designed to provide stable low-noise environment High sound isolation and low-noise performance: 20 db (>200 Hz) Reduced floor vibrations: 7.2 10-4 cm/sec 2 (100 Hz) Temperature variation (room temperature) around the microscope: ± 0.2 C/8 hours 3. The development process The development process was beset by numerous unexpected tragedies and other difficulties. Here we touch briefly on four of these challenges that proved particularly severe. 3-1 The passing of a veteran engineer in a key role Although the project was officially launched in March 2010, a serious setback was suffered when Isao Matsui a veteran engineer with a long history of involvement with the development of ultra-high-voltage electron microscopes who played a key role in the project proposal collapsed and died suddenly of scirrhous stomach cancer. Surely nobody was more deeply affected by this tragedy than Dr. Tonomura, who had worked closely with Matsui in advancing this project. Nonetheless, Dr. Tonomura s ongoing dedication to the project served as an inspiration to the remaining team members, who continued if in a somewhat somber mood to carry out their development efforts. Through the indefatigable efforts of the designers, the design of the major system components including the dedicated building, the high-voltage cable, and the high-pressure tanks that housed the high-voltage equipment proceeded on schedule, as did arrangements for their construction. Hitachi High-Technologies Corporation All rights reserved. 2016[49]

3-2 The Great Tohoku Earthquake The Great Tohoku Earthquake struck in March 2011. Although the development center in Saitama prefecture suffered no major damage, the high-voltage cable, which was under construction in Ibaraki prefecture, received water damage during the ensuing tsunami (Fig. 4). Starting over from scratch with this special-purpose 12.5-cm-diameter high-voltage cable was out of the question on both scheduling and budgetary grounds. Miraculously, a spare cable which was also under construction at the time and which managed to avoid water damage was completed with only slight delays. Another narrowly-averted disaster involved the Miyagi Prefecture-based electronics manufacturer responsible for developing the ultra-high-stability power supplies that may be said to constitute the beating heart of this microscope. In an event of providential good fortune, the advancing tsunami stopped just short of the factory, and the power supply was delivered without incident. Less happily, it was around this time that Dr. Tonomura was diagnosed with pancreatic cancer. Still, Dr. Tonomura was in strong spirits when, immediately after his diagnosis, he announced the situation to the full team and insisted that he would return to the project following his treatment. Fig.4 The high-voltage cable was damaged by the tsunami just before it was completed. 3-3 Withstand voltage of the high-voltage cables The dedicated building housing the microscope was erected in late August 2011, in accordance with the original plan (Fig. 3). 7) Thereafter, the power supply and the high-voltage cable were installed, and tests involving the application of 1.2 MV high voltages were conducted in late January 2012. Unfortunately, these tests found that electrical breakdown (discharge) occurred at 900 kv (Fig. 5). Because the cable had passed high-voltage tests involving the application of 1.3 MV prior to shipment from the factory, the unexpected appearance of electrical breakdown at such a low voltage came as a major shock. A response team of in-house high-voltage experts was drafted, and a battery of investigations including both simulations and experimental tests revealed that, according to dynamical simulations, there were some times at which high electric fields arose in regions in which near-zero electric fields had been expected. These had been overlooked by the static simulations conducted during the design phase. New electrodes capable of withstanding increased electric fields in the problematic regions were designed, and voltage-tolerance tests were finally passed in July 2012. Hitachi High-Technologies Corporation All rights reserved. 2016[50]

Cable end part Resin Discharge track Fig.5 Electrical breakdown near the ends of high-voltage cables A high negative voltage is applied to the tip while the base is grounded. In experiments involving high voltages applied to the tip of the cable, electrical breakdown occurred at voltages below the specified voltage of 1.2 MV, leaving discharge track in the resin surface. 3-4 Passing of Dr. Tonomura After undergoing surgery in April 2011, Dr. Tonomura briefly recovered to the point at which, six months after surgery, he was able to come to the laboratory but passed away on May 2, 2012. Although this unquestionably came as a major blow to the entire team, the team had been kept informed of almost all about Dr. Tonomura s condition at his own insistence and were thus at least somewhat prepared for the tragic news. The question of who would succeed Dr. Tonomura as Project Leader (Principal Scientist) was a pressing problem; ultimately the project was able to continue under the leadership of Dr. Nobuyuki Osakabe, who was then Director of the Central Research Laboratory and who, in his days as a researcher, had numerous prominent accomplishments in Dr. Tonomura s research group. 4. The challenge of achieving the highest resolution in the world By March 2014 we had progressed to the point of successfully obtaining electron microscope images with an accelerating voltage of 1.2 MV. Our next challenge was to achieve the highest resolution in the world. We had individually confirmed the stability of the high-voltage power supply, the appropriateness of the environment in which the equipment was installed, the stability of the electron beam, the operation of the aberration corrector and other components, so we felt it should be possible to achieve a resolution at the 40 pm level. In the first half of 2014 we immediately achieved resolutions of 60 pm, but subsequent progress was slow, and by October 2014 we had still not reached 50 pm. We attributed this failure to multiple factors, including the static performance of the stage, electrical noise disturbances, and sample damage. Among these, we chose to focus on sample damage in particular. To demonstrate resolution capable of identifying individual atoms, we had been observing samples that were only a few atoms thick; but subjecting such samples to continuous electron beam irradiation during observation causes their structure to collapse. For this reason, we adopted a strategy in which the focus of the electron beam would be adjusted in other locations, after which the beam would be quickly shifted to the observation site and multiple points would be imaged. As a result, we successfully observed a 44 pm spacing between Ga atoms (Fig. 6). Moreover, upon conducting resolution tests via other methods using single-crystal tungsten, we successfully captured the lattice spacing with an even better resolution of 43 pm, with good reproducibility. We announced these results in a journal article 9) and were ultimately recognized as having achieved the highest resolution in the world. Figure 7 shows the principal components of the completed atomic-resolution holography electron microscope. Hitachi High-Technologies Corporation All rights reserved. 2016[51]

(a) Simulated image Electron microscope image (b) Atomic model The three large high-pressure tanks Low-pass-filtered image (c) Electron microscope imaging unit (lens, sample stage, detector, etc.) Electron microscope control desk Front side of electron microscope Horizontal line signal intensity in regions 1 and 2 Electron microscope images of GaN Fig. 7 Atomic-resolution holography electron microscope Fig. 6 Observation of atomic spacing in gallium nitride (GaN) As a demonstration of the actual resolution of the electron microscope, we successfully captured electron microscope images showing the 44-pm spacing between two gallium atoms in single-crystal gallium nitride. 5. Conclusions The true value of this instrument lies not only in its status as the world s highest-resolution electron microscope, but also in its ability to make quantitative measurements of electromagnetic fields with atomic-scale resolution. By making full use of the power of this instrument to understand the quantum-mechanical phenomena responsible for the functionality and properties of highly functional material such as magnets, batteries, and superconductors, we hope our instrument will contribute to the advancement of basic science through research and development involving revolutionary cutting-edge functional materials. This development project was supported, through the Japan Society for the Promotion of Science, by the Funding Program for World-Leading Innovative R&D on Science and Technology, established by Council for Science, Technology, and Innovation. Hitachi High-Technologies Corporation All rights reserved. 2016[52]

References 1)A. Tonomura, et al. : Electron holography with a field emission electron microscope, Hitachi Hyoron, Vol.61 No.11 795-798 (1979). 2)A. Tonomura, et al. : High resolution electron holography with field emission electron microscope: Jpn. J. Appl. Phys. 18 No.1 (1979). 3)T. Kawasaki, et al. : Development of a 1MV field-emission transmission electron microscope, J. Electron Microsc. 49 No. 6 711-718 (2000). 4)A.Tonomura, et al. : Observation of Individual vortices trapped along columnar defects in high-temperature superconductors, Nature 412 No.6847 (2001). 5)M Haider, et al. : Correction of the spherical aberration of a 200 kv TEM by means of a hexapole corrector, Optik 99, 167-179 (1995). 6)L. W. Swanson : Comparative study of the zirconiated and built-up W thermal-field cathode, J. Vac. Sci. Technol. 12, 1228 (1975). 7)T. Kawasaki, et al. : Installation conditions for 1.2MV holography electron microscope, 69th Annual Meeting of the Japanese Society of Microscopy (2013.5.20-22). 8)K. Kasuya, et al. : Magnetic field superimposed cold field emission gun under extreme-high vacuum, J. Vac. Sci. Technol. B32 (3), 031802 (2014). 9)T. Akashi, et al. : Aberration corrected 1.2-MV cold field-emission transmission electron microscope with a sub-50- pm resolution, Appl. Phys. Lett. 106, 074101 (2015). Hitachi High-Technologies Corporation All rights reserved. 2016[53]