Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Similar documents
Product Catalogue. Fibre Optic Cable

Empowering businesses through innovative network solutions.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

LD Series High Performance Loose Tube Fiberoptic Cables

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

HITRONIC Optical Transmission Cable

OPTICAL FIBRE CABLE NETWORK 2004/1

SPECIFICATION. Optical Fiber Cable

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

OPTICAL CABLE FIBER-LAN INDOOR

FREEDM Loose Tube Interlocking Armored Cables

Ø 1000 * 588 mm 50 kg

Mining and Petrochemical Fiber Optic Cables

TECHNICAL SPECIFICATION

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Revision No. 4 Page No. Page 1 of 7

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

Detailed Specifications & Technical Data

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Micro duct Cable with HDPE Sheath for Installation by Blowing

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Table of Contents. Teldor Cables and Systems Ltd.

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

1. General. 1. Scope. 2. Quality Assurance

FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

Instrumentation & copper telecom cables

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

AFL Telecommunications

FIBER OPTIC CABLE сatalogue

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Gear up for the future.

FIBRE OPTIC CABLE SOLUTIONS

Number of Fiber 6 Core 12 Core. Part Number

Instrumentation Cables

OPTICAL FIBER CABLES FTTH. SPLITTER. ACCESSORY

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Number of Fiber 6 Core 12 Core 24 Core 48 Core

Cable installation guidelines

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Panduit Opti-Core Fiber Optic Cable

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

Siam Pacific Electric Wire & Cable Co., Ltd.

Let the colors of Holi spread the message of peace & happiness. FROM THE ED s DESK RPG CABLES INSIDE. March 2014.

A Comparison of Dry Versus Gel Filled Optical Cables

Fiber Optic Cabling Infrastructure Offering

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

OPTICAL FIBER CABLES FTTH. SPLITTER. ACCESSORY. The best technology and customer satisfaction

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Preferred ordering guide for NETCONNECT

Welcome to the latest edition of the Telstra Cable Guide.

SOLO ADSS Short-Span Cables, Fibers

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

TELEPHONE, FIBRE OPTIC, DATA AND COMPUTER CABLES 0, x4 0,5 0, x x x x4 0,5 0, x x4 0,4

Industry solutions: Broadcast

Cables for robot applications

Table of Contents. Open Matrix System (OMS) 1-2

Fiber Optic Cable For Industrial and Harsh Environments

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

THE INFORMATION GATEWAY FIBRE OPTIC CABLES

Cable Installation Tips

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

INDUSTRY SOLUTIONS: MINING

TENDER SUMMARY. Tender Title:

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

FTTH Products Cataolgue

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Cable Installation Tips

Material Description Quantity UOM

1 1/2 13.5, 625 JCASS)

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

DOME OPTIC SPLICE CLOSURE

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

Innovation and flexibility the quick, future proof, cost effective solution. PRODUCT CATALOGUE. 0 P a g e

جامعة مؤتة العطاءات املركزية توريد وتركيب وتشغيل أجهزة شبكات/كلية الزراعة. Central Tenders Mu tah University

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Compact Module. Category 6 FTP Cabling System

Transcription:

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

- SYMBOLS AND THE MEANING OF THE SYMBOLS FOR FIBRE OPTIC CABLES - SINGLE LOOSE TUBE, SINGLE SHEATH, NON METALLIC - SINGLE LOOSE TUBE, SINGLE SHEATH, CORRUGATED STEEL TAPE ARMORED, - MULTI LOOSE TUBE, SINGLE SHEATH, NON METALLIC ARMORED / DUCT I n d e x - MULTI LOOSE TUBE, SINGLE SHEATH, NON METALLIC ARMORED / DUCT TYPE DRY CORE CABLE - MULTI LOOSE TUBE, SINGLE SHEATH, CORRUGATED STEEL TAPE ARMORED,DIRECT BURIAL / DUCT TYPE - MULTI LOOSE TUBE, DOUBLE SHEATH, DOUBLE GALVANIZED STEEL TAPE ARMORED, DIRECT BURIAL / DUCT TYPE - MULTI LOOSE TUBE, DOUBLE SHEATH, CORRUGATED STEEL TAPE ARMORED,DIRECT BURIAL / DUCT TYPE 1 - MULTI LOOSE TUBE, DOUBLE SHEATH, NON METALLIC ARMORED, DIRECT BURIAL / DUCT TYPE - MULTI LOOSE TUBE, DOUBLE SHEATH, ADSS AERIAL TYPE - SIMPLE PATCH CABLE (ZIPCORD) - DUBLEX PATCH CABLE (DUBLEX ZIPCORD) - BREAKOUT CABLES INDOOR - BREAKOUT CLABLES OUTDOOR - AERIAL TYPE BREAKOUT CABLES WITH MESSENGER

THE MEANING OF THE SYMBOLS FOR FIBRE OPTIC CABLES 2 SLT MLT SA NMA DA SJ DJ SINGLE LOOSE TUBE MULTI LOOSE TUBE CABLES CORRUGATED STEEL TAPE NON METALLIC STRENGHT MEMBER DOUBLE ARMOR TWO LAYERS OF GALVANIZED STEEL TAPE SINGLE JACKET (SHEATH) DOUBLE JACKET (SHEATH) -A AERIAL CABLE -P FIBER OPTIC + POWER HYBRID CABLE LSZH ADSS DIN VDE 0888 LOW SMOKE ZERO HALOGEN SHEATH ALL DIELECTRIC SELF SUPPORTING CABLE OPTICAL FIBER CABLES STANDARD A- OUTDOOR CABLE B (BN) D E F G ARMORING GLASS YARN NON METALLIC ARMORING FOR RO- DENT PROTECTION LOOSE BUFFER TUBE, FILLED GLASS YARN NON METALLIC ARMORING FOR RO- DENT PROTECTION SINGLE MODE FIBER FILLING COMPOUND IN THE CABLE CORE MULTI MODE FIBER J INDOOR CABLE (L) Q (SR) Y 2Y (ZN) LAMINATED ALUMINIUM TAPE DRY SWELLABLE MATERIAL IN THE CABLE CORE (DRY CORE) ARMORING BY LAMINATED, CORRUGATED, LONGITU- DINAL, OVERLAPPED STEEL TAPE POLYVINYL CHLORIDE JACKET (SHEATH) POLYETHYLENE JACKET (SHEATH) NON-METALLIC ANTI-BUCKLING ANG STRENGHT MEMBERS

SINGLE LOOSE TUBE, SINGLE SHEATH, NON METALLIC ARMOURED DUCT TYPE INTERNAL & EXTERNAL FIBER OPTIC CABLE Light weight structure enables easy and fast installation Non Metallic / All dielectric structure prevents electromagnetic interference Rodent Protection and waterproof Preferred for LAN, WAN applications for structural cabling and premise networks Optional LSZH sheath enables usage as Indoor cable as well as Outdoor 1 - Outer PE Sheath (Optional LSZH sheath) 2 - E-Glass yarn 3 - Loose Tube (PBT) 4 - Water Resistive Tube fi lling Compound 5 - Optical fi bers 6 - Ripcord single loose tube SLT-MNA-SJ,(A-DQ(ZN)B2Y) Core Count: Cable Weight (kg/km): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 2 to 24 55 Outer Diameter (mm): Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3: Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 7 1200 to 2500 1500 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C 3

SLT-SA-SJ/(A-DQ(ZN)SR)2Y) single loose tube SINGLE LOOSE TUBE, SINGLE SHEATH, CORRUGATED STEEL TAPE ARMOURED, DIRECT BURIAL / DUCT TYPE Light weight structure enables easy and fast installation Smaller diameter permits easy handling Rodent Protection and waterproof Application in PE Pipes by blowing / plough technique Preferred for LAN, WAN, MAN application for structural cabling and Premise networks Possibility of usage as Indoor Cable as well as Outdoor due to light structure Optional supporting or galvanized Steel Wire or Power Cable: SLT-SA-SJ-A (A-DQ(ZN)(SR)2YT) SLT-NMA-SJ-A (A-DQ(ZN)B2YT) SLT-NMA-SJ-P (A-DQ(ZN)B2Y+POWER) 1 - Outer PE Sheath (Optional LSZH Yarn) 2 - Non Metallic Strenght element (glass Yarn or Aramid Yarn) 3 - Core Wrapping(s) 4 - PBT Tube 5 - Core Filling Compound 6 - Optical Fibers 7 - Water Resistive Tube Filling Compound 8 - Non Metallic Central Strenght Member 9 - Ripcord SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 4 Core Count: Cable Weight (kg/km): Outer Diameter (mm): Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3: Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 2 to 24 85 7,5 1200 2500 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C

MULTI LOOSE TUBE, SINGLE SHEATH, NON METALLIC ARMOURED / DUCT Light weight structure enables easy and fast installation Possibility of usage as Indoor Cable as well as Outdoor due to light structure Non Metallic Construction / All dielectric structure prevents electromagnetic interference and enables application in power lines side by side with Energy Cables Waterproof Rodent protection-provided by adequate amount of E glass yarn Suitable to be installed with blowing /ploughing method Optional LSZH Sheath Optional version with external Power Cable: MLT-NMA-SJ-P (A-DF(ZN)B2Y+POWER) 1 - Outer PE Sheath (Optional LSZH Yarn) 2 - Non Metallic Strenght element (glass Yarn or Aramid Yarn) 3 - Core Wrapping(s) 4 - PBT Tube 5 - Core Filling Compound 6 - Optical Fibers 7 - Water Resistive Tube Filling Compound 8 - Non Metallic Central Strenght Member 9 - Ripcord multi loose tube MLT-NMA-SJ(A-DF(ZN)B2Y) Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 1200 (Min.) to. 6000 3000 Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Single Sheath, Non Metallic Armored/Duct Fiber Count Buffer Count Filler Count Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 12 100 6 1 5 12 100 8 1 (2) 5 (4) 12 100 10 5 1 12 100 12 1 (3,2) 5 (3,4) 12 100 16 4 (2) 2 (4) 12 100 24 6 (2,4) 0 (4,2) 12 110 36 6 (3) 0 (3) 12 110 48 6 (4) 0 (2) 13 120 60 5 1 13 130 72 6 0 13 130 96 8 0 15 160 144 12 0 20 260 192 16 0 23 290 5

MLT-NMA-SJ-DRY(A-DQ(ZN)B2Y) multi loose tube MULTI LOOSE TUBE, SINGLE SHEATH, NON METALLIC ARMOURED/DUCT, TYPE DRY CORE CABLE Light weight structure enables easy and fast installation Possibility of usage as Indoor Cable as well as Outdoor due to light structure Non Metallic Construction / All dielectric structure prevents electromagnetic interference and enables application in power lines side by side with Energy Cables Waterproof Rodent protection-provided by adequate amount of E glass yarn Suitable to be installed with blowing /ploughing method Optional LSZH Sheat 1. Outer PE Sheath (Optional LSZH Yarn) 2. Non Metallic Strength element (glass Yarn or Aramid Yarn) 3. Water Swelling Tape 4. PBT Tube 5. Water Swelling Yarn 6. Optical fi bers 7. Water Resistive Tube fi lling Compound 8. Non Metallic Central Strength Member (FRP) 9. Ripcord 6 Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 1200 (Min.) to. 6000 3000 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Single Sheath, Non Metallic Armored/ Duct Type Dry Core Cable Fiber Count Buffer Count Filler Count Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 12 100 6 1 5 12 100 8 1 (2) 5 (4) 12 100 10 5 1 12 100 12 1 (3,2) 5 (3,4) 12 100 16 4 (2) 2 (4) 12 100 24 6 (2,4) 0 (4,2) 12 110 36 6 (3) 0 (3) 12 110 48 6 (4) 0 (2) 13 120 60 5 1 13 130 72 6 0 13 130 96 8 0 15 160 144 12 0 20 260 192 16 0 23 290

MULTI LOOSE TUBE, SINGLE SHEATH, CORRUGATED STEEL TYPE ARMORED, DIRECT BURIAL/ DUCT TYPE Light weight but heavy duty direct burial / duct usage Single sheath enables easy and fast installations Suitable to be installed and used in harsh environments under heavy weather conditions Rodent Protection and waterproof Application both as backbone cable for WAN Telecommunication Systems and as data lines for LAN / Structure Cabling 1. Outer PE Sheath (Optional LSZH Yarn) 2. Corrugated Steel Tape Armored 3. Non Metallic Strength element (glass Yarn or Aramid Yarn) 4. Core Wrapping(s) 5. Core fi lling Compound 6. PBT Tube 7. Water Resistive Tube fi ling Compound 8. Optical fi bers 9. Non Metallic Central Strength Member (FRP) 10. Ripcord SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 multi loose tube MLT-SA-SJ(A-DF(ZN)(SR)2Y Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): 1500 (Min.) to. 6000 4000 Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Single Sheath, Corrugated Steel Tape Armored, Direct Burial /Duct Type Fiber Count Buffer Count Filler Count Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 13 150 6 1 5 13 150 8 1 (2) 5 (4) 13 150 10 5 1 13 150 12 1 (3,2) 5 (3,4) 13 150 16 4 (2) 2 (4) 13 150 24 6 (2,4) 0 (4,2) 13 160 36 6 (3) 0 (3) 14 160 48 6 (4) 0 (2) 14 160 60 5 1 14 170 72 6 0 14 170 96 8 0 16 210 144 12 0 19 330 192 16 0 22 560 7

MLT-DA-DJ 8 multi loose tube MULTI LOOSE TUBE M u l t i l o o s e t u b e, d o u b l e s h e a t h, d o u b l e l a y e r s w a a n d s p a g a l v a - n i z e d s t e e l t y p e a r m o r e d, d i r e c t b u r i a l / d u c t t y p e Heavy duty cable for direct burial / duct usage Suitable to be installed and used in hard environments under heavy weather conditions Galvanized Steel Armor and Second Jacket provides protection against Rodents, moisture and all external effects. Waterproof Aluminum foil provides extra protection against moisture Suitable to be used for all type of underground application To be used as backbone cable for WAN telecommunication systems Two layers of galvanized steel tapes helically overlapped around the inner jacket to improve the mechanical strength of the cable 1. Outer PE Sheath 2. Crepe Paper 3. Helically Applied Double layer of Galvanized Steel Tape by overlapping method 4. Crepe Paper 5. Inner PE Sheath 6. Aluminum Foil 7. Aramid Yarn for tensile strength 8. Core Wrapping(s) 9. Core fi lling Compound 10. Ripcord 11. PBT Tube 12. Water Resistive Tube fi lling Compound 13. Optical fi bers 14. Non Metallic Central Strength Member Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 3000 (Min.) to. 10000 6000 20xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Double Sheath, Double Layer Swa and Spa Galvanized Steel Tape Armored, Direct Burial/Duct Type Fiber Count Buffer Count Filler Count Outer Sheath thickness Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 1,1/2 17 370 6 1 5 1,1/2 17 370 8 2 4 1,1/2 17 370 10 5 1 1,1/2 17 370 12 3 3 1,1/2 17 370 24 6-1,1/2 17 370 36 6-1,1/2 18,5 440 48 6-1,1/2 18,5 440 72 6-1,1/2 19,5 480 96 8-1,1/2 21 580 144 12-1,1/2 25 810

MULTI LOOSE TUBE M u l t i l o o s e t u b e, d o u b l e s h e a t h, c o r r u g a t e d s t e e l t a p e a r m o r e d, d i r e c t b u r i a l / d u c t t y p e Heavy duty cable for direct burial /duct usage Suitable to be installed and used in harsh environments under heavy weather conditions Corrugated Steel Armor and Second Jacket provides protection against Rodents, moisture and all external effects To be used as backbone cable for MAN, WAN, LAN applications and GSM, CATV, SMATV networks Rodent protection and waterproof Possibly of installation with blowing / plough technique into PE pipes or applied directly underground 1. Outer PE Sheath 2. Corrugated Steel Tape Armored 3. Inner PE Sheath 4. Aramid yarn for tensile strength (or Glass Yarn) 5. Core Wrapping(s) 6. Core fi lling Compound 7. Ripcord 8. PBT Tube 9. Water Resistive Tube fi lling Compound 10. Optical fi bers 11. Non Metallic Central Strength Member(FRP) SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 multi loose tube MLT-SA-DJ(A-DF(ZN)2Y(SR)2Y Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): 2500 (Min.) to. 8000 5000 Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Single Sheath, Corrugated Steel Tape Armored, Direct Burial /Duct Type Fiber Count Buffer Count Filler Count Outer Sheath thickness Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 1,1/2 17 370 6 1 5 1,1/2 17 370 8 2 4 1,1/2 17 370 10 5 1 1,1/2 17 370 12 3 3 1,1/2 17 370 24 6-1,1/2 17 370 36 6-1,1/2 18,5 440 48 6-1,1/2 18,5 440 72 6-1,1/2 19,5 480 96 8-1,1/2 21 580 144 12-1,1/2 25 810 9

MLT-NMA-DJ/(A-DF(ZN)2YB2Y) multi loose tube MULTI LOOSE TUBE M u l t i l o o s e t u b e, d o u b l e s h e a t h, n o n m e t a l l i c a r m o r e d, d i r e c t b u r i a l / d u c t t y p e Heavy duty cable for direct burial / duct usage Suitable to be installed and used in hard environments under heavy weather conditions Galvanized Steel Armor and Second Jacket provides protection against Rodents, moisture and all external effects. Waterproof Aluminum foil provides extra protection against moisture Suitable to be used for all type of underground application To be used as backbone cable for WAN telecommunication systems Two layers of galvanized steel tapes helically overlapped around the inner jacket to improve the mechanical strength of the cable 1. Outer PE Sheath 2. Non metallic strength member (Aramid Yarn or Glass Yarn) 3. Inner PE Sheath 4. Core Wrapping(s) 5. Core fi lling Compound 6. PBT Tube 7. Optical fi bers 8. Water Resistive Tube fi lling Compound 9. Non Metallic Central Strength Member(FRP) 10. Ripcord 10 Tensile Strenght (N) (IEC 794-1-E1): Crush Strength (N/10cm) (IEC 794-1-E3): Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 2000 (Min.) to. 5000 4000 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Double Sheath, non Metallic Armored, Direct Burial/Duct Type Fiber Count Buffer Count Filler Count Outer Sheath thickness Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 1,1/1,6 14 140 6 1 5 1,1/1,6 14 140 8 2 4 1,1/1,6 14 140 10 5 1 1,1/1,6 14 140 12 3 3 1,1/1,6 14 140 24 6-1,1/1,6 14 140 36 6-1,1/1,6 14 140 48 6-1,1/1,6 14 140 60 5 1 1,1/1,6 16 180 72 6-1,1/1,6 16 180 96 8-1,1/1,6 18 230 144 12-1,1/1,6 20 390

MULTI LOOSE TUBE M u l t i l o o s e t u b e, d o u b l e s h e a t h, a d s s a e r i a l t y p e Aerial cable type without Steel Messenger Wire Aerial installation between the poles with the help of special installation / suspension equipment All dielectric construction enables application in power lines side by side with Energy Cables Very light and easy to install Special High Density Black PE provides excellent resistance during installation and protection against external effects like tough weather conditions and UV Ray during operation Generally preferred as Aerial backbone cable for Wide Area Telecom Networks Optional armored steel wire supported version: MLT-SA-SJ -A (A-DF(SR)2YT) 1. Outer Black special HDPE Sheath 2. High modulus Aramid Yarns 3. Optional Inner PE Sheath 4. Core Wrapping(s) 5. PBT tube 6. Core fi lling Compound 7. Optical fi bers 8. Water Resistive Tube fi lling Compound 9. Non Metallic Central Strength Member 10. Ripcord multi loose tube MLT-SA-DJ(A-DF(ZN)2Y(SR)2Y Tensile Strenght (N) (IEC 794-1-E1): SM: 652-B, G 652-D, G 655 MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3 2700 (Min.) to. 15000 Crush Strength (N/10cm) (IEC 794-1-E3): Min Permissible Bending Radius (mm) (IEC 794-1-E 11): Temperature Range ( C) (IEC 794-1-F-1): 4000 15xo static & 20xo dynamic where o is cable outside diameter in mm During Operation: -40 C to + 70 C During Installation: -30 C to + 60 C Other type of Multi Loose Tube, Double Sheath, Adds Aerial Type Fiber Count Buffer Count Filler Count Outer Sheath thickness Cable Diameter Aprx (mm) Cable Weight (Kg/Km) 4 1 5 1,1/1,6 14 140 6 1 5 1,1/1,6 14 140 8 2 4 1,1/1,6 14 140 12 1 (3) 5 (3) 1,1/1,6 16 150 24 2 4 1,1/1,6 16 150 36 3 3 1,1/1,6 16 150 48 4 2 1,1/1,6 16 160 60 5 1 1,1/1,6 16 180 72 6-1,1/1,6 16 180 11

SIMPLE PATCH CABLE (zipcord) J-VH 1x1 LSZH ZIPCORD Indoor interconnected and Patch-cord installations. All dielectric non-metallic construction, hence no ground loop problems 1. Optical fi ber 2. Tight buffered fi bre of 900 µm diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive/Low Smoke Zero Halogen Outer Jacket Number of Fibers: Outer Sheath Diameter: Weight: Minimum Bending Radius: Tensile Strenght: Crush Resistance: Operating Temperature: 1 ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656 (NZDS Fiber) 1,8 mm / 2,8 mm 5,10 (Kg/Km) 25 (N) 150,200 (N) 300 (N) -30 C to +70 C Standard Cable Colour 12 Multi Mode 50/125: Multi Mode 62,5/125: Single-Mode: Standard Cable Marking: Blue Orange Yellow (Other colours are avaiable upon request) Cable <Cable Type><Meter Marking><Manufacturing Year>

DOUBLE PATCH CABLE (Dublex Zipcord) Indoor interconnected and Patch-cord installations. All dielectric non-metallic construction, hence no ground loop problems 1. Optical fi ber 2. Tight buffered fi bre of 900 µm diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive/Low Smoke Zero Halogen Outer Jacket dublex zipcord J-VH 2x1 LSZH Number of Fibers: Outer Sheath Diameter: Weight: Minimum Bending Radius: Tensile Strenght: Crush Resistance: Operating Temperature: 2 ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656 (NZDS Fiber) 1,8 x 3,6 mm / 2,8 x 5,6 mm 14,20 (Kg/Km) 25 (N) 300 (N) 400 (N) -30 C to +70 C Standard Cable Colour Multi Mode 50/125: Multi Mode 62,5/125: Single-Mode: Standard Cable Marking: Blue Orange Yellow (Other colours are avaiable upon request) Cable <Cable Type><Meter Marking><Manufacturing Year> 13

BREAKOUT CABLES INDOOR J-V2H nx1 LSZH breakout cables Indoor and duct installations; Halogen Free Flame Retardant / Flame Retardant Non-Corrosive / Low Smoke Zero Halogen design. All dielectric non-metallic construction, hence no ground loop problems; Ready for direct connectorization in fi eld; suitable for backbone and horizontal sub systems such as FTTH and FTTD. 1. Optical fi ber 2. Tight buffered fi bre of 900 µm diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive/Low Smoke Zero Halogen Outer Jacket Number of Fibers: Outer Sheath Diameter: Weight: Minimum Bending Radius: Tensile Strenght: Crush Resistance: Operating Temperature: 2-12 ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656 (NZDS Fiber) 4,0 mm to 7,5 mm 35, 60 (Kg/Km) 15 x Diam. 400 to 2000 (N) 1000 (N) -30 C to +70 C Standard Cable Colour 14 Multi Mode 50/125-62,5/125: Orange Single-Mode: Yellow (Other colours are avaiable upon request) Standard Reel Lenght: 1000 m -2000 m Standard Cable Marking: Cable <Cable Type><Meter Marking><Manufacturing Year>

BREAKOUT CABLES OUTDOOR Outdoor and duct installations; ready for direct connectorization in fi eld; suitable for backbone and horizontal sub systems such as FTTH and FTTD. 1. Optical fi ber 2. Tight buffered fi bre of 900 µm diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive/Low Smoke Zero Halogen Outer Jacket 5. Corrugated Steel Tape armored 6. Outer Black PE Sheath breakout cables A-V2H(SR)2Y nx1 Number of Fibers: Outer Sheath Diameter: Weight: Minimum Bending Radius: Tensile Strenght: Crush Resistance: Operating Temperature: 2-12 ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656 (NZDS Fiber) 10 mm / 12 mm 110,140 (Kg/Km) 20 x Diam. (N) 1200 to 2000 (N) 2000 (N) -30 C to +70 C Standard Cable Colour Standard Colour: Black Multi Mode 50/125-62,5/125: Orange Standard Reel Lenght: 1200 m - 2000 m 15 Standard Cable Marking: Cable <Cable Type><Meter Marking><Manufacturing Year>

A-V2H(SR)T2Y nx1 aerial type breakout AERIAL TYPE BREAKOUT CABLES WITH MESSENGER Outdoor and Aerial installations; ready for direct connectorization in fi eld; suitable for backbone and horizontal sub systems such as FTTH and FTTD. 1. Optical fi ber 2. Tight buffered fi bre of 900 µm diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive/Low Smoke Zero Halogen Outer Jacket 5. Corrugated Steel Tape armored 6. Outer Black PE Sheath 7. Supporting Steel Wire Number of Fibers: Outer Sheath Diameter: Weight: Minimum Bending Radius: Tensile Strenght: Crush Resistance: Operating Temperature: 2-12 ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656 (NZDS Fiber) 8,5 x 16 mm to 13x21 mm 150, 190 (Kg/Km) 20 x Diam. 2000 (N) 2000 (N) -30 C to +70 C Standard Cable Colour 16 Standard Colour: Black Multi Mode 50/125-62,5/125: Orange Standard Reel Lenght: Standard Cable Marking: 1000 m - 2000 m Cable <Cable Type><Meter Marking><Manufacturing Year>

COUNTRY PROJECT CONTRACTOR TYPE OF CABLE POLAND LYBIA POLSKIE LNG REGASIFICA TION TERMI- NAL PROJECT SIRTI FIBER HYBRID CABLE SWEET CONDENSATE STABILIZER UNIT PROJECT AT MARSA EL BREGA GAS PLANT SIRTE OIL COMPANY FIBER HYBRID CABLE DUBAI NATIONAL PETROLEUM CONST. CO NPCC & ADCO FIBER OPTICAL CABLES PROJECT LIST 17

RAMCRO 18