Deposited on: 9 th May 2012

Similar documents
Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Characterisation of the far field pattern for plastic optical fibres

Screen investigations for low energetic electron beams at PITZ

Impact of DMD-SLMs errors on reconstructed Fourier holograms quality

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

Measurement of Microdisplays at NPL

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

NDT Applications of All-Electronic 3D Terahertz Imaging

Compact multichannel MEMS based spectrometer for FBG sensing

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Research on sampling of vibration signals based on compressed sensing

RECOMMENDATION ITU-R BT.1201 * Extremely high resolution imagery

Building Your Own 2-Photon Microscope: Challenges, Advantages and Limitations

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Operation of CEBAF photoguns at average beam current > 1 ma

Television Projects of Fernseh GmbH (Int. Dr. Möller)

Release Notes for LAS AF version 1.8.0

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

Hidden melody in music playing motion: Music recording using optical motion tracking system

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Analysis of WFS Measurements from first half of 2004

Sodern recent development in the design and verification of the passive polarization scramblers for space applications

8 DIGITAL SIGNAL PROCESSOR IN OPTICAL TOMOGRAPHY SYSTEM

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

Elements of a Television System

MCP Upgrade: Transmission Line and Pore Importance

Automatic Defect Recognition in Industrial Applications

Reconstruction of Ca 2+ dynamics from low frame rate Ca 2+ imaging data CS229 final project. Submitted by: Limor Bursztyn

If your sight is worse than perfect then you well need to be even closer than the distances below.

This work was supported by FINEP (Research and Projects Financing) under contract

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

CS2401-COMPUTER GRAPHICS QUESTION BANK

Preface. The information in this document is subject to change without notice and does not represent a commitment on the part of NT-MDT.

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Beam Instrumentation for CTF3 and CLIC

SPATIAL LIGHT MODULATORS

A Real Time Infrared Imaging System Based on DSP & FPGA

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

Photocathodes FLASH: Quantum Efficiency (QE)

Cathode Studies at FLASH: CW and Pulsed QE measurements

Opto-VLSI-based Tunable Linear-Cavity Fibre Laser

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

Uncooled amorphous silicon ¼ VGA IRFPA with 25 µm pixel-pitch for High End applications

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

Transfer Radiation Thermometer With Temperature Range Of 0 C To 3,000 C

Enhanced 2D-image upconversion using solid-state lasers

Studies for Future Broadcasting Services and Basic Technologies

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Reading. Display Devices. Light Gathering. The human retina

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

METROTOM. Visible Metrology.

I n d u s t r i a l M e t r o l o g y f r o m C a r l Z e i s s. METROTOM. Visible Metrology.

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Connection for filtered air

Mechanical aspects, FEA validation and geometry optimization

Sealed Linear Encoders with Single-Field Scanning

Photoinjector Laser Operation and Cathode Performance

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

CBF500 High resolution Streak camera

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

TracQ Basic. Spectroscopy Software v6.6. User's Manual

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

Reducing tilt errors in moiré linear encoders using phase-modulated grating

An Alternative Architecture for High Performance Display R. W. Corrigan, B. R. Lang, D.A. LeHoty, P.A. Alioshin Silicon Light Machines, Sunnyvale, CA

Part 1: Introduction to Computer Graphics

Standard Operating Procedure of nanoir2-s

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

SEM- EDS Instruction Manual

Transmissive XBPM developments at PSF/BESSY. Martin R. Fuchs

LASER REGISTRATION FORM (LS-1)

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Teaching Plasma Nanotechnologies Based on Remote Access

Mahdad Manavi LOTS Technology, Inc.

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

Performance Evaluation of Industrial Computed Radiography Image Display System

Selection Criteria for X-ray Inspection Systems for BGA and CSP Solder Joint Analysis

120W Beam Light AL-BL-120 FEATURES. Lamp: PHILIPS 2R 120W. Channel mode: 20CH. Level scanning: 540 (16bit precision scan) electronic error correction

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

arxiv:hep-ex/ v1 27 Nov 2003

Failure Analysis Technology for Advanced Devices

An Overview of the Performance Envelope of Digital Micromirror Device (DMD) Based Projection Display Systems

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Bar Codes to the Rescue!

How to Chose an Ideal High Definition Endoscopic Camera System

Modulation transfer function of a liquid crystal spatial light modulator

Light Emitting Diodes

Optical Technologies Micro Motion Absolute, Technology Overview & Programming

New Filling Pattern for SLS-FEMTO

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Transcription:

Ma, Y., Grant, J., Saha, S., and Cumming, D. (2012) Terahertz single pixel imaging based on a Nipkow disk. Optics Letters, 37 (9). pp. 1484-1486. ISSN 0146-9592 http://eprints.gla.ac.uk/63137/ Deposited on: 9 th May 2012 Enlighten Research publications by members of the University of Glasgow http://eprints.gla.ac.uk

Terahertz single pixel imaging based on a Nipkow disk Yong Ma, James Grant, Shimul Saha and David Cumming* School of Engineering, University of Glasgow, Glasgow, G12 8LT, UK *Corresponding author: David.Cumming.2@glasgow.ac.uk We describe a terahertz single pixel imaging system based on a Nipkow disk. Nipkow disks have been used for fast scanning imaging systems since the first experimental television was invented in 1926. In our work, a Nipkow disk with 24 scanning lines was used to provide an axial resolution of 2 mm/pixel. By implementing the microscanning technique the axial resolution can be further improved to 0.5 mm/pixel. Imaging of various object masks was demonstrated to show this simple and low cost system is promising for fast and/or real time terahertz imaging applications. Recently, terahertz imaging systems have been intensively developed due to their wide applications in areas of security [0], non-invasive inspection [2] and medicine [3]. In conventional imaging systems a mechanical scanning method is implemented to obtain 2-D imaging information which limits the imaging acquisition speed [4]. Terahertz imaging systems based on electro-optical sampling and a conventional CCD camera are reported to be able to achieve real time imaging [5-6]. However these systems require high power laser sources in order to obtain a sufficient signal to noise ratio (SNR). Such a high power laser significantly increases both the cost and complexity of the imaging system. Commercial Focal Plane Arrays ( FPA ) primarily developed for the mid-infrared wavelength range have also been used for terahertz imaging systems. However the detection efficiency of such FPAs is poor in the THz range (typically only 5% absorption is obtained) therefore high power terahertz

sources are still needed to overcome the poor detection efficiency. In addition to 2-D multi-pixel arrays, a terahertz single pixel detector can be also used for a fast imaging system. Chan et al. reported a single pixel terahertz imaging system based on compressed sensing ( CS ) theory [10]. Random masks were used to enable high speed imaging acquisition. A single pixel imaging system based on CS theory is a promising technique for a low cost and fast imaging system, though practical implementation is still limited due to the lack of fast spatial modulators to provide random masks and the complexity of computing processing [11]. In this paper, we describe another approach of single pixel terahertz fast imaging based on a Nipkow disk which is simpler and more cost effective. The Nipkow disk has been used for imaging systems since the first television was invented in 1926. As shown in Figure 1, the Nipkow disk consists of a series of small apertures with equal diameter. The small apertures are positioned in the form of a single-turn spiral starting from an external radial point of the disk and proceeding to the center of the disk. In the imaging system, the disk is placed at the position of the imaging plane. The disk is partially covered by terahertz opaque material, leaving only a small window as the imaging area. The size of the window is set to make sure that only one aperture is positioned in the imaging area when the disk is rotated. When the disk is rotated, the spirally positioned aperture moves on the image surface in a circular trace. The light transmitted through each aperture is collected and detected by a focusing lens and a single pixel detector. Consequently a 2-D image is obtained by scanning the image line by line with the movable aperture.

The technique is almost 100 years old though it is still used in various modern imaging instruments such as the optical confocal microscope [12]. The Nipkow disk used in our terahertz imaging system is made of aluminium, consisting of a series of 24 apertures with a diameter of 2 mm for scanning the object image, as shown in Figures 1(a) and (b). The apertures are equally spaced in angle over the disk. The distance from the centre of the apertures to the centre of disk is varied with a fixed increment of 2 mm. A second series of apertures is placed along the outer edges of the disk with equal distance. These apertures (5mm in diameter) are used for timing and indicate the break of each scanning line. Among these apertures is a rectangular shaped aperture (10 mm long) which is used to indicate the start time of the image scan. We use a linear coordinate system to describe the position of the image pixels, as shown in Figure 1 (a). For the Nipkow disk with the above geometric parameters, we can obtain a 50 mm x 50 mm imaging area with an axial (Y-axis ) resolution of 2 mm/pixel. The resolution along the X-axis is determined by both the acquisition rate of the detector and the rotation speed of the disk, which can potentially be very high. In our work the acquisition rate of the detector is set to be 300 µs and the rotation speed is 2 rps. The maximum resolution along the X-axis is about 0.18 mm/pixel. We manually manipulate the resolution along the X-axis using the control software (Labview 8.6) as 0.5 mm/pixel for the demonstration. The experimental set up is shown in Figure 2. The terahertz source used in this work is continuous terahertz radiation, of frequency 2.52 THz with a maximum power of 150 mw, generated via a CO 2 pumped methanol vapour laser (Edinburgh

Instruments). The beam from the terahertz source is a Gaussian shaped circular spot 15 mm in diameter. A 90 o off-axis parabolic mirror was used to expand the laser beam size to 60 mm in diameter. The Nipkow disk was placed at the position where the whole imaging area is covered by the beam spot. A mask with word patterns was placed 5 mm in front of the Nipkow disk Another 90 o off-axis parabolic mirror was used to collect and focus the transmitted light from the aperture of the Nipkow disk onto the single pixel pyroelectric detector. A mechanical chopper was placed in front of the pyroelectric detector to modulate the THz beam. The signal of the pyroelectric detector was picked up by a lock-in amplifier (Model 5210 Signal Recovery) with time constant set at 300 µs. Both the lock-in signal and the timing signal were monitored on a digital oscilloscope. A Labview program was used to acquire data from the oscilloscope, process the raw data and consequently build a 2-D image using the processed data. First, the intensity profile of the THz beam was imaged by removing the mask and the first parabolic mirror, as shown in Figure 2. The result shows a Gaussian-like imaging profile with beam diameter of 16 mm, which is in good agreement with the beam size measured by the manufacturer. As shown in Figure 2, the image is not slightly blurred due to the low resolution ( 2 mm/pixel ) along the X-axis. There are two methods to improve the resolution of the x-axis. One is to increase the number of apertures thus the number of the scanning lines. Another is to use Multiframe Techniques ( MT ) based on translational microscanning [13]. In our work, we used the latter as shown in Figure 1(c). For MT, multiple frames of the image are obtained

by mechanically shifting the Nipkow disk along the x-axis by a certain distance. Then the obtained multiple frames are interlaced so that a resultant image is obtained with increased resolution, as shown in Figure 3. There is slight distortion of the image in the direction of the Y-axis which is caused by the variable rotation speed. This issue can be solved by using a stepper motor with precise speed control. In our work, object masks with the word pattern THZ were also imaged, as shown in Figure 3. The object masks are made of black aluminum tape on a HDPE plastic plate which is transparent in the terahertz frequency range. The results are shown in Figure 3. The objects were imaged at different axial-resolutions (0.5 mm/pixel, 1 mm/pixel, 2 mm/pixel). The resolution of Y-axis was set at 0.5 mm/pixel for this demonstration. Figures 5(m)-(o) shows the visible image of the objects. Figures 5(d)-(f),(g)-(i) and (j)-(l) show the constructed THz images of the objects at various x-axis resolutions; 0.5 mm/pixel, 1 mm/pixel and 2 mm/pixel respectively. The acquisition time for each single frame is 2 s which can be reduced by increasing the rotation speed and/or decreasing the time constant of the lock-in amplifier. In this paper, we demonstrated a single pixel imaging system based on a Nipkow disk. Various object masks are imaged using this system. Multiframe Techniques (MT) based on translational microscanning were used to improve the resolution without changing the Nipkow disk itself. Images with a resolution of 0.5 mm/pixel have been obtained with a 2s acquisition time of a single frame. A Nipkow disk provides a simple and low cost solution for terahertz 2-D imaging with a single pixel detector. Faster or even real time imaging is possible using this system with high rotation speed

and detection rate of the detector.

References 1 Shen, Y. C. Lo, T. Taday, P. F. Cole, B. E. Tribe, W. R. Kemp, M. C, Detection and identification of explosives using terahertz pulsed spectroscopic imaging, Applied Physics Letters, Vol.86, 241116-241118 (2005). 2 J.B. Jackson, M. Mourou, J.F. Whitaker, I.N. Duling III, S.L. Williamson, M. Menu, G.A. Mourou, Terahertz imaging for non-destructive evaluation of mural paintings, Optics Communications, Vol. 281, 527-532 (2008). 3 Siegel, P. H, Terahertz Technology in Biology and Medicine, IEEE Transactions on Microwave Theory and Techniques, Vol. 52, 2438-2447 (2004 ). 4 Adrian Dobroiu, Masatsugu Yamashita, Yuichi N. Ohshima, Yasuyuki Morita, Chiko Otani, and Kodo Kawase, "Terahertz Imaging System Based on a Backward-Wave Oscillator", Applied Optics, Vol. 43, 5637-5646 (2004) 5 Zhiping Jiang, X. G. Xu, and X.-C. Zhang, "Improvement of terahertz imaging with a dynamic subtraction technique," Applied Optics, Vol. 39, 2982-2987 (2000) 6 Nahata, A. Yardley, J. T. Heinz, T. F, Two-dimensional imaging of continuous-wave terahertz radiation using electro-optic detection, Applied Physics Letters,Vol.81, 963-965 (2002 ). 7 Alan Wei Lee and Qing Hu, "Real-time, continuous-wave terahertz imaging by use of a microbolometer focal-plane array," Optics Letters, Vol. 30, 2563-2565 (2005). 8 Jun Yang, Shuangchen Ruan, and Min Zhang, "Real-time, continuous-wave terahertz imaging by a pyroelectric camera," Chinese Optics Letters, Vol. 6, 29-31 (2008). 9 Diana Glaab, Sebastian Boppel, Alvydas Lisauskas, Ullrich Pfeiffer, Erik Öjefors, and

Hartmut G. Roskos, Terahertz heterodyne detection with silicon field-effect transistors, Applied Physics Letters, Vol.96, 042106 (2010). 10 Chan, W.L. Charan, K. Takhar, D. Kelly, K.F. Baraniuk, R.G. Mittleman, D.M, A single-pixel terahertz imaging system based on compressed sensing, Applied Physics Letters,Vol. 93, 121105 (2008 ).. 11 W. L. Chan, H. Chen, A. J. Taylor, I. Brener, M. Cich, and D. M. Mittleman, "A Spatial Light Modulator for Terahertz Radiation," in Conference on Lasers and Electro-Optics/International Quantum Electronics Conference, OSA Technical Digest (CD) (Optical Society of America, 2009), paper CThX2. 12 D. M. Grant, D. S. Elson, D. Schimpf, C. Dunsby, J. Requejo-Isidro, E. Auksorius, I. Munro, M. A. Neil, P. M. French, E. Nye, G. Stamp, and P. Courtney, "Optically sectioned fluorescence lifetime imaging using a Nipkow disk microscope and a tunable ultrafast continuum excitation source," Optics Letters, Vol. 30, 3353-3355 (2005). 13 Alam, M. S. Bognar, J. G. Hardie, R. C. Yasuda, B. J, Infrared Image Registration and High-Resolution Reconstruction Using Multiple Translationally Shifted Aliased Video Frames,IEEE Transactions on Intrumentation and Measurement, Vol.49, 915-923 (2000).

Figure list Figure 1 (a) Sketch of the Nipkow disk (b) Geometric parameters for our Nipkow disk (b) Resolution improvement by implementing the microscanning technique. The numbers 1, 2 and 3 represent the imaged pixels for frame 1,2 and 3 respectively. Figure 2 Experimental set up for the single pixel imaging system based on a Nipkow disk. Section A is the measurement set up for imaging an object mask and section B is the measurement set up for imaging the FIR laser pattern profile. Figure 3 (a)-(c) Imaging of the FIR laser beam pattern at resolutions of 0.5, 1.0 and 2.0 mm/pixel respectively. (d)-(i) Imaging of an object mask with the word pattern THZ at various resolutions (d)-(f): 0.5 mm/pixel (g)-(i):1.0 mm/pixel (j)-(l): 2.0 mm/pixel.

Figure 1 (a) Sketch of Nipkow disk (b) Geometric parameters for Nipkow disk (b) Resolution improvement by using the microscanning technique. The numbers 1, 2 and 3 represent the imaged pixels for frames 1,2 and 3 respectively.

Figure 2 Experimental set up for the single pixel imaging system based on a Nipkow disk. Section A is set up for imaging the object mask and section B is set up for imaging the FIR laser pattern profile.

Figure 3 (a)-(c) Imaging of FIR laser beam pattern at resolutions of 0.5, 1.0 and 2.0 mm/pixel respectively. (d)-(i) Imaging of an object mask with word pattern THZ at various resolution (d)-(f): 0.5 mm/pixel (g)-(i):1.0 mm/pixel (j)-(l): 2.0 mm/pixel.