IEPE Premium Accelerometer, Side Connector

Similar documents
IEPE Premium Accelerometer, Top Connector

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PMG. Vibration Energy Harvesters

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Eddy Current Probe System

Inductive sensor BI1.5-EG08K-Y1

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMP 331i / DMP 333i LMP 331 i

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Inductive sensor With analog output BI15-M30-LI-EXI

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Foreword The SKF brand now stands for more than ever before, and means more to you as a valued customer. While SKF maintains its leadership as the hal

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Selection matrix for electronic pressure switches

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

TFRN Industrial RTD temperature sensor. CombiTemp TM

Model JDF Field Indicator

Practical considerations of accelerometer noise. Endevco technical paper 324

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

TFRN Industrial RTD temperature sensor. CombiTemp TM

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Micro-Machined Silicon Transducers

AGS Low profile capacitive air gap measuring sensor for rotating machines

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Pressure transmitter For applications in hazardous areas Model IS-3

Stock Products. Over 10,000 Sensors In-Stock Ready to Ship!

TFRH Hygienic RTD temperature sensor. CombiTemp TM

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Material: Weight: IP Rating: Cable: Connector:

Thermocouple and RTD Modules for Compact FieldPoint

Absolute Encoders Multiturn

MODEL HS35 DRAWWORKS OPTICAL ENCODER

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Pendant Light Fitting IEC Series 6470/2

Quality products from a single source

Type SCH94FO. Type SCH94FO. Description

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Digital Input Modules for Compact FieldPoint

3500/42M Proximitor*/Seismic Monitor

R&S RT-Zxx High-Bandwidth Probes Specifications

EXPlora. Introduction

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Cylindrical Photoelectric Sensor CY-100 SERIES

Modular Lube Lubrication Systems System Controls

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

MAP110 AC-DC Series Data Sheet

ODW-621. RS-232 Point-to-point applications

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Capacitance Level Measurement Electronic insert FEC 12

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Series CT7N Bimetallic Overload Relays

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Proportional output thumbwheels - sprung to centre

NI PXI/PXIe-2543 Specifications

02/11/2015

TFR5 Room or outdoor temperature sensor. CombiTemp TM

EZ-LIGHT K30L Series With Independent Push Button Contact

Assembly. Front view. LEDs. Parametrization interface. Power Bus

3500/72M Rod Position Monitor

EZ-LIGHT K90FDL Daylight Visible

Series SK (2.92 mm) prec. submini. connectors

Photoelectric Sensors E3F2

Fibre Optic Modem ODW-622

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Ordering details. Approval. Classification

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

MILLITARY SPECIFICATION SHEET

RMA42. Technical Information

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

VOD/DATA RECORDERS AND ACCESSORIES FOR ASSOCIATED APPLICATIONS PRODUCT LIST

Transcription:

IEPE Premium Accelerometer, Side Connector Main Characteristics Atex Approved for zone 0, 1, 2. Piezoelectric annular shear mode 10, 50, 100, 250, 500, 1000 mv/g version available -55 C to 120 C (-67 F to 250 F) Dual case isolation with Faraday shield Submersible version (150 metres). life time hermetic sealing warranty (M12/Mil glass seal connector) Competitive advantage Compare to obsolete compression design, annular shear piezoelectric sensors feature better frequency response, improved base strain, lower noise, smaller size, thermal transient immunity and insensitivity to cable motion. Annular shear mode is also less susceptible to transverse vibrations and better immune to electronic saturation at high frequency. Improved dynamic range (thanks to exceptional bias stability) at elevated temperatures. Resistant to shock (magnet mounting) thanks to Jfet transistor input. ESD and reverse wiring protection. The glass seal hermetic connector protects the piezoelectric disc and the electronic from harmful environmental influences, significantly increasing their reliability and lifetime. Sensors with epoxy seal will always leak after few temperature cycles. M12 connector offers compatibility with numerous sensors used in automation. M12 overmolded cable assemblies are available from many cable manufacturers around the world. Mil cordset are expensive because they are only available from vibration sensor manufacturer. Description The hermetic sealed industrial piezoelectric accelerometer model 101 is designed to monitor the vibration in harsh industrial environment. It uses the industry standard ICP / IEPE / LIVM 2-wire voltage transmission technique with a 4 ma standard constant current supply. Signal ground is isolated from the mounting surface and outer case to prevent ground loops. Faraday shielding will limit sensitivity to EMC to a minimum. Annular shear mode design will prevent from thermal transient and from spurious signal from high transverse vibrations. Low noise electronic and a temperature compensated design will give you accurate result over the complete temperature range. Large choice of frequency range will help to fit almost every customer requirements. Low frequency accelerometers (A=9, 0) incorporate a low-pass filter within the conditioning electronic. This filter attenuates the sensor mechanical resonance and the associated distortion and overload. Typical applications Model 103.02-6-1 Vibrations measurement in the rugged environments of industrial machinery monitoring. High frequency version monitor the vibration on roller bearing, pumps cavitation,... Medium frequency version monitor overall vibration on pumps, motors, fans,... Low frequency model is used in the petrochemical, machine tool, and paper industries for monitoring of slow speed agitators, cooling towers,... High temperature version is typically used where extra temperature protection is needed, such as the dryer section of a paper machine. Approvals Revision History May 2003 : Released Dec 2014 : electronic upgrade Sept 2016 : improved case electrical isolation Nov 2017 : new housing with M8 option.

Ordering information To order, specify model number, options, accessories and suffix : 103.02- AA - B - TT - HH - YY AA : Sensitivity 3. 10 mv/g ± 5 % 3D.... 10 mv/g ± 10 % 5... 50 mv/g ± 5 % 5D. 50 mv/g ± 10 % 6 100 mv/g ± 5 % 6D 100 mv/g ± 10 % 7. 250 mv/g ± 5 % 7D 250 mv/g ± 10 % 8 250 mv/g ± 5 % 8D 250 mv/g ± 10 % 9. 500 mv/g ± 5 % 9D. 500 mv/g ± 10 % 0 1000 mv/g ± 5 % 0D 1000 mv/g ± 10 % Note: 7, 9, 0 High pass frequency = 0.2 Hz. Available suffix : N, negative polarity B : Connector 1. MIL-C-5015, glass sea l, Type MS3143 10SL-4P 2.. M12 glass seal, IEC 60947-5-2 B (CC-DD) : Integral Cable 5(01-DD)..... 90 C Polyurethane cable 5(02-DD).... 200 C Teflon FEP cable 5(03-DD)... 120 C Radox Halogen Free cable 5(31-DD)... 90 C Polyurethane cable with Temperature output 5(12-DD)... 200 C Teflon FEP cable with Temperature output 5(13-DD). 120 C Radox Halogen Free cable with Temperature output 7(01-DD)...90 C Polyurethane cable with sstl overbraid protection 7(02-DD)... 200 C Teflon FEP cable with sstl overbraid protection 7(03-DD) 120 C Radox Halogen Free cable with sstl overbraid protection 7(12-DD) 200 C Teflon FEP cable with sstl overbraid & Temperature output 7(13-DD). 120 C Radox Halogen Free cable with sstl overbraid & Temp output 8(01-DD). 90 C Polyurethane cable with stainless steel protection conduit 8(02-DD). 200 C Teflon FEP cable with stainless steel protection conduit 8(03-DD).. 120 C Radox Halogen Free cable with sstl protection conduit 8(31-DD). 90 C PU cable with sstl protection conduit & Temp. output 8(12-DD).200 C Teflon FEP cable with sstl protection conduit & Temp. output 8(13-DD). 120 C Radox cable with sstl protection conduit & Temp. output DD length in metres. Standard length are 2m, 5m, 10m, 15m, 20m, 30m. TT : Temperature output. ( Not available with Mil-C-5015 2 pins connector) HH : Housing Thread Omitted... no temperature output T0... 10 mv/ C. (range +2 to +120 C) Omitted... ¼ 28 UNF H8... M8x1.25

YY : Explosion proof Agency Approval Omitted... no specific agency approval Y1 (Atex & IECEx)....... LCIE X.XXX Group Category Gaz - Protection. II 1 G - Ex ia IIC T4 Ga Group Category Dusts - Protection II 1 D - Ex ia IIIC T135 C Da Group Mine - Protection... Not Applicable AA can be 3, 3D, 5, 5D, 6, 6D, 7, 7D, 8, 8D, 9, 9D, 0, 0D B can be 1, 2 B(CC,DD) can be 5(03-DD), 7(01-DD), 7(02-DD), 7(03-DD) 8(01-DD), 8(02-DD), 8(03-DD) DD 99 metres TT can be Omitted HH can be Omitted or H8 Y5 (CSA Approval).... Not Released. IS Class 1, Division 1, Groups A to D.. Ex ia IIC / Class I, Zone 0 AEx ia IIC T4 AA Options can be...same as Y1 (Atex) OEM or Customer Engraving : Add ZXX at the end of the part number. XX is a number supplied by VibraSens Customer Engraving is not allowed for Explosion proof sensor. OEM should contact VibraSens if they need custom Engraving for Explosion proof sensor. In stock Model Metric connector 103.02-6D-2 100 mv/g ±10% general purpose version 103.02-6-2 100 mv/g ±5 %, general purpose version Available Model with short lead time (2 weeks) 103.02-6D-5(01-05) integral polyurethane cable, 5 metres 103.02-6D-7(02-05) integral 200 C sstl overbraided teflon cable, 5 metres 103.02-9D-2 500 mv/g ±10 %, low frequency version 103.02-0D-2 1000 mv/g ±10 %, low frequency version Ordering example : 103.02-6D-2 Premium accelerometer, 100mV/g, M12 glass seal side connector 193.31-06-1 M6 mounting screw 103.02-6D-7(02-05)-H8 Premium accelerometer, 5 metres Integral teflon cable with Stainless steel overbraid. 193.31-08-1 M8 mounting screw

Specifications (24 C) Dynamic Frequency response (Typical curve). See Fig. 1. & 2.. A=3X ±30 % : 1 to 9000 Hz A=6X A=9X A=0X Mounted Resonant frequency A=3X A=5X, 6X A=9X, 0X Dynamic range A=3X A=5X A=6X A=9X A=0X ±30 % : 1 to 8000 Hz.±10 % : 0.4 to 1600 Hz ±3 db : 0.2 to 3700 Hz ±10 % : 0.4 to 1600 Hz ±3 db : 0.2 to 3700 Hz 35 khz Nom. 25 khz Nom. 16 khz Nom. 800 g pk. 160 g pk. 80 g pk 16 g pk 8 g pk Transverse response sensitivity (20Hz, 5g) <5% Temperature response Linearity Warm up time A=3X, 5X, 6X A=9X, 0X see fig3.±1% Max < 1Sec < 10 Sec Temperature Output (Option T0) Only available if sensor is powered via IEPE Output (between - and Temp) 0VDC at 0 C Vout=10mV/ C * Temp.( C) Range: +2 to 120 C Electrical Electrical Grounding Isolation(Case to shield) Capacitance to ground Output impedance Isolated from machine ground Internal Faraday shielding 100 MΩ Min 70 pf Nom 50 ΩNom DC output bias, 4mA supply (AA=3X, 5X, 6X) DC output Bias, 4 ma supply (AA=9X, 0X) 12 VDC Nom 10 VDC Nom Residual noise (24 C) : A=3X (10 mv/g) 1 Hz 200 ug / Hz 10 Hz 30 ug / Hz 100 Hz 10 ug / Hz 1000 Hz 10 ug / Hz

Residual noise (24 C) : A=6X (100 mv/g) 1 Hz 30 ug / Hz 10 Hz 6 ug / Hz 100 Hz 5 ug / Hz 1000 Hz 5 ug / Hz Residual noise (24 C) : A=9X (500 mv/g) 0.1 Hz 20 ug / Hz 1 Hz 6 ug / Hz 10 Hz 2 ug / Hz 100 Hz 2 ug / Hz 1000 Hz 2 ug / Hz Residual noise (24 C) : A=0X (1000 mv/g) 0.1 Hz 20 ug / Hz 1 Hz 5 ug / Hz 10 Hz 1 ug / Hz 100 Hz 0.5 ug / Hz 1000 Hz 0.5 ug / Hz Power requirements Protection Overvoltage Reverse polarity ESD Protection Constant current : +2 to +10mA DC Voltage : +22 to +28 VDC Yes Yes > 40 V Environmental Temperature, operating continuous : (max. current =4mA) A= 3X, 5X, 6X -55 to 120 C (-65 to 250 F) A=9X.-55 to 90 C (-65 to 212 F) A=0X -55 to 70 C (-65 to 158 F) Humidity / Enclosure B=1, 2 B=5, 7, 8 Not affected, hermetically sealed, 1E-8 torr.l/s IP68, epoxy sealed Acceleration limit : Shock Continuous vibration Base strain sensitivity Temp. transient sens. (3Hz, LLF, 20dB/dec) Acoustic sensitivity (164 dbsp) Electromagnetic sens. (50Hz, 0.03 T) 5000g peak 500g peak 0.0002 g pk/u strain 5 mg/ C 0.5 mg 0.2 g Physical Design Ceramic, annular shear mode Weight with connector A=3 150 gr Nom (5.2 Oz) A=5, 6 155 gr Nom (5.6 Oz) A=9, 0 165 gr Nom (6.0 Oz) Weight with Integral cable : add sensor weight above +

BB=5(CC-DD) BB=7(CC-DD) BB=8(CC-DD) Material Mounting torque (M6, M7) 40gr/m 60 gr/m 105 gr/m AISI 316L, DIN 1.4404 (Stainless steel) 2,4 N.m (21 in-lbs) European Directive EMC Directive RoHS Directive 2014/30/EU Standards 61326-1 Certificate Atex & IECEx Approval (YY=Y1) Atex Directive Standards Certificates Installation Drawing EU Declaration of Conformity 2011/65/EU 101.51-YN_Rohs2 2014/34/EU EN 60079-0, Atex General EN 60079-11, Intrinsic safety, Gas IEC 61241-0, Atex General IEC 61241-11, Intrinsic safety, Dust LCIE ATEX XXX IECEx XXXXXX 101.51-Y1-IMI 101.51-Y1_EUDC Accessories, supplied Calibration supplied Sensitivity (5g, 160 Hz) Accessories, not supplied Mounting Hex cap screw : M6 machine thread 193.31-06-1 ¼ 28 UNF machine thread 193.31-16-1 M8x1.25 193.31-08-1 Cable assembly B=1 (Mil connector) Polyurethane cable (90 C) FEP Teflon cable (200 C) Cable assembly B=2 (M12 connector) Polyurethane cable (90 C) FEP Teflon cable (200 C) 10.01-A01-B22-06-Length 10.01-A01-B22-02-Length 10.01-A01-E02-31-Length 10.01-A01-E61-02-Length For more cable option see Model 10.01 (specific cable harness). Calibration, back to back, Frequency response (10 Hz-5 khz), 4 pages 501.11 Calibration, back to back, single point., A4 certificates 501.01 Repair Consult factory for replacement of connector in case of broken or bended pins. Repair of electronic is not possible.

Configurations Mil-C-5015 (B=1) Pin A : (+) Pin B : (-) Associated cable 10.01-A01-B22-06-Length: Red (+); White (-) Note: No temperature option available M12 glass seal (B=2) Pin 1 : NC Pin 2 : NC or temp. output (T0 option) Pin 3 : (-) Pin 4 : (+) Associated cable 10.01-A01-E02-31-Length Black (+); Blue (-) Temperature Output (T0 option) between Blue (-) and White (+) Integral Cable B=5(CC-DD) CC=01, 02 (PU, Teflon) : White (-); Red (+) CC=03 (Radox) : White N 1 (-); White N 2 (+) CC=12 (Teflon): White (-) ; Red (+) Temperature output between Black(+) and White (-) CC=13 (Radox) : White N 1 (-); WhiteN 2 (+) Temperature output between White N 3(+) and White N 1 (-) CC=31 (PU) : Blue(-); Black(+); Brown (NC) Temperature output between White(+) and Blue (-) NC: Not connected; (1) with T0 option

Integral cable with overbraid B=7(CC-DD) Same wiring color as B=5 Integral cable with protection conduit B=8(CC-DD) Same wiring color as B=5

Fig 2. Low Frequency response, amplitude Fig 3. DC (Bias) deviation versus temperature Fig 4. : Sensitivity deviation versus temperature Legal Information Information furnished by VibraSens is believed to be accurate and reliable. However, no responsibility is assumed by VibraSens for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owner.