Model PR710 Series Signal conditioner operating guide

Similar documents
MachineryMate 800 operating guide Handheld vibration meter

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model /29S RF Splitter

Noise Detector ND-1 Operating Manual

Practical considerations of accelerometer noise. Endevco technical paper 324

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Model 1421 Distribution Amplifier

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

G.R.A.S. Sound & Vibration

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Instruction Manual Model BlockUpconverter

Active UTP Transceiver Hub Installation Guide

J R Sky, Inc. tel: fax:

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

Instruction Manual Model # Block Upconverter

REPLAY JUNIOR. True high voltage tube delay. V 1.1 (27-August-2012) Operations Manual

PH 1.1 Phono Preamplifier Owner s Manual

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

HS-509 VIBRATION TRIP MODULE

Chameleon Labs Model 7720

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

SCALE & WEIGHT DISPLAYS

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

12 Channel Media Splitter MS12 Mk2 User manual

Model R177M and R177S Baseband Switch

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Various regulation agencies require us to bring the following information to your attention. Please read carefully.

COUGAR AUDIO ROUTING SWITCHER

1900/25 Vibration Monitor

SATRI AMPLIFIER AMP-51R. Owner s Manual

Field Service Procedure Replacement GACP Control Panel Kit, ST24

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

bel canto SEP2 Single Ended Triode Tube Preamplifier User's Guide and Operating Information

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

clipping; yellow LED lights when limiting action occurs. Input Section Features

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Mapletree Audio Design

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

The performance of a lifetime. Owner s Manual MOON 110LP v2 Phono Preamplifier

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

MANUAL DE INICIO RÁPIDO ESPAÑOL ( 7 10 ) GUIDE D UTILISATION RAPIDE FRANÇAIS ( ) MANUALE RAPIDO DI UTILIZZAZIONE ITALIANO ( )

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

384A Adapter Installation Instructions

KD-CATDRV. Operating Instructions. HDMI CAT5/5e/6 Extender

Operation Manual for. SCU1 Signal Conditioning Unit

Phono Amplifier brinkmann «EDISON» Manual.

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

USB Phono Plus. Project Series USER S MANUAL. Audiophile Computer Interface

MclNTOSH MODEL C-4 and C-4P

COHERENCE ONE PREAMPLIFIER

Active UTP Transceiver Hub

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Single-Output 2000 W

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

3500/42M Proximitor * /Seismic Monitor Bently Nevada* Asset Condition Monitoring

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

3500/42E Vibration Monitor

QDA4-44 RF Amp/Combiner

Installation Guide. CVC 300 Component Video and HDTV to RGB Converter Rev. B 12 08

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DISTRIBUTION AMPLIFIER

LAUREL ELECTRONICS, INC.

instruction manual video mixer model 614gs & 614g

UTP ACTIVE TRANSCEIVER HUB

Model P/03P Upconverters

PHASE HL SEL 1 HL SEL 2 EXT MONITOR ELAN ELAN ELAN ELAN MLM-201 HLM-201 HLM-201 TBM-201 MLM-201 GAIN GAIN GAIN LEFT GAIN RIGHT SELECT SELECT SELECT

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

instruction manual video scan reverser models NVCN422CS & NVCN422C

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

.Power Distribution Center. PD-1. Instruction Manual

10-Channel 16-Bit Analog Board Set User s Manual And Troubleshooting Guide

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

3124mb+ All Discrete 4 Channel Mic/Instrument Preamplifier with Stereo Mixer Operator s Manual

110LP MOON Series. Phono Preamplifier. Owner s Manual

1900 Series Digital Antenna Monitors User's Guide

KD-CSW2x1. Operating Instructions. 2 Inputs to 1 Output Component Video/Audio Switcher. KD-CSW2x1 Operating Instructions.

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Winmate Communication INC.

Model 22.1 HDCD D/A Converter Instructions

QCA9-33 Active Combiner

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

R-1580A Microwave Downconverter. Product Brochure

HPA-8 8 Channel Headphone Amplifier. Owner s Manual

DELV-2LCD-7XLPRO DELV-2LCD-7XLRM DELV-2LCD7XLS (SDI) USER MANUAL

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

CP1 OAD. Owner s Manual. Stereo Control Preamplifier. Ultrafidelity

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Transcription:

Model PR710 Series Signal conditioner operating guide Caution: This manual should be read carefully before operating any of the PR710 series signal conditioners. Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies Tel: +1 (301) 330-8811 Tel: +1 800 WILCOXON Fax: +1 (301) 330-8873 www.wilcoxon.com

1.0 Product description 1.1 PR710 supplied components The PR710 Series signal conditioner consists of a main chassis assembly and the associated external power supply. The PR710 Series rack mountable signal conditioner occupies a 5-1/4 rack height in a 19 wide rack. The PR710 Series signal conditioner is available in two versions, the PR710A and the PR710B. Both models are identical in function, but have different frequency ranges of operation and different input connector types. The PR710A can be used with any IEPE accelerometer. The PR710B has been optimized for use with the 731A low frequency, low noise accelerometer. The PR710 data sheet details the differences between the two models. 1.2 Description of the PR710 1.2.1 Power supply The PR710 operates from an external power supply which helps maintain the exceptionally low noise floor of the PR710 amplifiers. The power supply provides 30 VDC to power the chassis electronics. The power supply operates from any standard AC power source in the world if it provides the required input: 95 to 250 Volts AC, 1.2 Amp maximum 47 to 63 Hz The unit is shipped with a power cord for standard U.S. power wall outlets. For other countries, IEC-type power cords with AC wall terminations appropriate for that country should be used. The AC input is through a standard IEC 320 connector. The power supply includes an attached output cable and connector. 1.2.2 Rear panel The rear panel contains two rows of ten (10) BNC connectors. Model PR710A has standard BNC connectors. Model PR710B has twin-axial BNC connectors (see caution below). The INPUT BNC connectors are in the upper row, while the OUTPUT BNC connectors are in the lower row. The power input connector is located in the upper right of the rear panel. Caution: The PR710B input connectors are twinaxial BNC connectors. Attempting to force a standard co-axial BNC into the twin axial BNC will damage the input connector. 91206 Rev B 08/17 Page 2 of 5

1.2.3 Front panel The front panel of the PR710 contains the main power switch and control switches for each channel of the PR710. The power switch is in the lower left of the front panel. Above the power switch is the power indicator Light Emitting Diode (LED), which illuminates when the power switch is in the ON position and power is applied to the rear panel power input connector. The LED will extinguish if the input voltage drops below 27 VDC. Each channel has an LED, two switches, and an OUTPUT BNC connector on the front panel. The PR710 is specifically designed to furnish the constant DC current necessary to operate the internal amplifier of piezoelectric transducers (accelerometers and velocity sensors), which require a constant current power supply. Each channel of the PR710 contains a fault monitor with a red LED indicator. The indicator illuminates when a fault occurs, such as the transducer or cable is open or shorted. The fault monitor uses a dual comparator that monitors the DC voltage on the output of the transducer. If either the transducer or cable is shorted, the transducer s bias output voltage (BOV) will go to zero, tripping the lower comparator and illuminating the fault indicator. Similarly, if either the transducer or cable is open, the voltage will go to the supply voltage, tripping the upper comparator and illuminating the fault indicator. The nominal fault voltages are 2 VDC for a shorted condition and 22 VDC for an open condition. The LED will also illuminate under a severe signal overload conditions. Each channel has an amplifier gain switch. The amplifier gain (amplification) can be set to amplify by a factor of 1 (0 db), 10 (20 db), or 100 (40 db). Example #1: A 100 mv/g sensor is connected to a channel. The gain switch is set to 100. The OUTPUT of that channel will be 10.0 Volts/g (100 mv x 100 = 10,000 mv = 10.0 Volts) Each channel has a filter that can be applied to the sensor signal. Additionally, the accelerometer signal can be integrated to provide a velocity signal output from an accelerometer signal input. The switch position settings are: NONE: FILTER: No filtering applied to that channel sensor signal Filter applied according to the table below 91206 Rev B 08/17 Page 3 of 5

VEL: The accelerometer signal of the channel will be integrated to produce a velocity signal output with a gain of 0.1 applied to the mv sensitivity Example #2: A 100 mv/g accelerometer is connected to a channel. The front panel output gain switch is set to 1 and Velocity is selected. The output sensitivity will be 10 mv/inch/second (100 x 1 x 0.1 = 10 mv/ips) Example #3: A 100 mv/g accelerometer is connected to a channel. The front panel output gain switch is set to 100 and Velocity is selected. The output sensitivity will be 1.0 Volt/inch/second (100 x 100 x 0.1 = 1,000 mv/ips = 1.0 Volt/IPS) Frequency response of the PR710 filter for the Model PR710A and PR710B: Switch setting PR710A PR710B NONE (no filter) 0.05-45,000 Hz 0.05-1,000 Hz FILTER (filter in) 0.05-1,000 Hz 0.05-100 Hz VEL (integration in) 1-20,000 Hz 1-1,000 Hz The front panel OUTPUT connector is wired in parallel with the rear panel OUTPUT connector. The output of the PR710 may be taken from either the front panel or the rear panel. Caution: If connections are made to both the front panel OUTPUT connector and the rear panel OUTPUT connector, those connections are being made to the same circuit connection point. They are in parallel. 2.0 Operation of the PR710 1. Ensure the power switch is in the OFF position. 2. Connect AC power to the power supply. 3. Connect the power output cable from the external power supply to the power INPUT connector on the PR710 rear panel. 4. Connect the cable from each sensor to be powered to the rear panel INPUT BNC connector. 5. Connect a cable to the OUTPUT BNC connector and the other end to the measuring equipment used to measure the vibration signal as desired. 6. Verify all cable connections. 7. Turn the front panel power switch to the ON position. 8. Wait about ten seconds and check all channel fault LED indicators. If any channel fault indicator is illuminated for a channel being used, verify the connections for that channel. For troubleshooting assistance refer to Technical Note 14 Trouble shooting industrial accelerometer installations available from Wilcoxon s online knowledge desk at www.wilcoxon.com. 9. Set the front panel filter selections to NONE or FILTER as desired. 10. Set the front panel switches to VEL for those channels where the accelerometer input signal is to be integrated to a velocity vibration signal. 91206 Rev B 08/17 Page 4 of 5

11. Set the front panel gain switches to the gain level for each channel as desired. The PR710 is now ready for use. 3.0 Maintenance The PR710 contains no user-serviceable parts. No maintenance should be attempted by the user. Opening the chassis and attempting any maintenance may void the user s warranty. 4.0 Technical assistance 4.1 Technical assistance For technical assistance, please contact Wilcoxon Sensing Technologies at 301-330-8811 or email info@wilcoxon.com. 4.2 Customer service To obtain a return materials authorization number, please contact customer service at 301-330- 8811, fax at 301-330-8873, or email info@wilcoxon.com. 91206 Rev B 08/17 Page 5 of 5