Technical Report No. 68.184.16.115.01 Dated 2016-03-03 Client: Manufacturing place: Name: MY LUMENS TECH. LTD Address: 7F., Block 5, Yali Industrial Park, Tianbao Road, No.13 Ying Renshi New Village, Shiyan Town, Bao an District, Shenzhen, P.R. China Contact person: Mr. Boking Pang Manufacturer s name: Same as client. Address: Same as client. Factory s name: Same as client. Address: Same as client. Trade mark: MY LUMENS Test subject: Product: LED Panel Light Type: MY-PL 600 Test specification: According to client s requirement to perform measurement as below: 1. Luminous intensity distribution according to IES LM-79-08; 2. Unified Glare Rating (UGR) for indoor fixed luminaires. Purpose of examination: Inspection according to the Geräte- und Produktsicherheitsgesetz ProdSG, version November 08, 2011 Inspection according to the observance of the protection aims of the following EC directives: 2006/95/EC Test according to the test specification Test result: See section 4 for details. This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. Page: 1 of 7
1 Description of the test subject 1.1 Function Manufacturer s specification for intended use: LED panel light designed for general lighting. Manufacturer s specification for predictive misuse: No restrictions provided. 1.2 Consideration of the foreseeable misuse Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis 1.3 Technical Data Fixed general purpose luminaires (LED panel light) Rated Voltage: Rated Frequency: Rated Power: Brand Name: Rated color temperature: Rated Luminous flux: 220-240 VAC 50/60 Hz 33W MY LUMENS 4000K 4800lm 2 Order 2.1 Date of Purchase Order, Customer s Reference 2016-02-26 2.2 Receipt of Test Sample, Location 1pc of test sample was received on 2016-02-26, ENE Department, Shenzhen 2.3 Date of Testing 2016-02-26 to 2016-03-03 2.4 Location of Testing Road 2, Nanshan District 518052 Page: 2 of 7
2.5 Points of Non-compliance or Exceptions of the Test Procedure None 3 Test instruments and conditions 3.1 Test instruments Equipment Model Brand/Manufacturer Calibration due date Digital Power Meter WT210 YOKOGAWA 2016-08-19 Temperature data logger 34970A Agilent 2016-04-26 Multimeter, Graphical 111 Fluke 2016-12-23 Digital Temperature and SK-L200TH SATO 2016-09-20 Humidity data logger Goniophotometer system GO-R5000- SML Everfine 2016-03-11 3.2 General conditions for measurement Ambient temperature ( C): 25± 1 Maximum relative humidity (%): 52.5 Maximum air speed (m/s): < 0.2 Test voltage tolerance (%): ± 0.2 Test voltage and frequency (V & Hz): 230VAC & 50Hz Page: 3 of 7
4 Test result 4.1 Test data Page: 4 of 7
UGR (Unified Glare Rating) Table Remark: 1. CIE Pub.117 Corrected 4801lm Total Lamp Luminous Flux. (8log(F / F0) = 5.5 2. C Range: 0 ~ 360 Degree; C Interval: 22.5 Degree; 3. Range: 0 ~ 180 Degree; Interval: 1.0 Degree; 4. Luminaire length: 595.0 mm; 5. Luminaire width: 595.0 mm. Page: 5 of 7
Annex 1: Photo documentation. Details of: Over view --End-- Page: 7 of 7