ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Similar documents
Measure IT Uvisor System User Manual. Measure IT Uvisor. MFD Multi Flame Detector Control Unit ABB

VGA AUDIO SWITCHER S MANUAL

Wall-/Pipe-Mount Level Indicator

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Process Transmitter RMA 422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Quick Operation Guide of LTN7700/7600 Series NVR

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Truck router (3Gbps/HD/SD/ASI)

4 x 4 VGA Matrix Switch

Process transmitter RMA422

LAUREL ELECTRONICS, INC.

FOM-9010, FOM-9011 and FOM-9012

Single Point Flow Monitor SW118 SW119

ex 800 Series ematrix System

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LD OEM/LD PDS/LD PeCo

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Condition Monitoring Custom Products

Rack mounted telephone- and leased line modem for industrial applications

AF-300 E11 Adjustable Frequency Drive

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Dissolved Oxygen Transmitter

LONWORKS Fibre Optic Converter

X-Band Redundant LNB Systems

263 Series LED Bargraph Indicator and Controllers

Multi-Format AV Scaler with DisplayPort

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

LED control gear Compact fixed output

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

HS-509 VIBRATION TRIP MODULE

Seamless Matrix MULTI-ROOM AUDIO AND VIDEO DISTRIBUTION ORDER NO. EL-4KM-VW44

DCP100 Digital Control Programmer Specifications

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Dissolved Oxygen Transmitter

Modular Lube Lubrication Systems System Controls

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIMATRIX NEO V2 Modular Video Matrix

EVENT INPUT/OUTPUT MODULE [PUME]

Model /29S RF Splitter

Series CT7N Bimetallic Overload Relays

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Ku-Band Redundant LNB Systems

C-Band Redundant LNB Systems

SCALE & WEIGHT DISPLAYS

Modular Expansion Cards

VGA AUDIO AUDIO MATRIX SWITCHER S MANUAL

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LONWORKS Fibre Optic Router

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

NEXT/RADIUS Shelf Mount CCU

HDMI Matrix Switches. Product Data Sheet. Basic Features. Overview. Ordering Information

Generator protection relay

The 6700 series Panel lock and destination protect

CLR-101C CAMERA LINK REPEATER. User s Manual. Document # , Rev 1.0, 2/24/2013

Instruction Manual Model BlockUpconverter

TELEDYNE HASTINGS INSTRUMENTS

IMPAC Infrared Thermometers

SmartVideo: SSV Feature Summary

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

User s Manual. Document # , Rev 1.2, 6/12/2006

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

OM2000N INSTALLATION MANUAL

Magnecraft Power Relays

INSTALLATION & USER GUIDE

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

Kramer Electronics, Ltd.

Fibre optic router for TP/FT-10 LRW-112PP

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

I/A Series Hardware Fiber Optic LAN Converter

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Lt DELTA USA, Inc

CLV-401A CAMERA LINK VIDEO SPLITTER. User s Manual. Document # , Rev 1.1, 4/2/2018

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

TempScan/1100 & MultiScan/1200

LED Driver Compact fixed output

UNIGAS Hand-held combustion gas analyzer with 3 sensors

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

GFT Channel Digital Delay Generator

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

ATEA LED ACDC User Manual (0) ATEA LED

Transcription:

(Rev. C) Multi fuel / multi flame detector system Two - Systems - In - One Application: - Industrial and large utility boilers - NG, BFG, Oil, Orimulsion and pulverized coal burners Dual channel flame scanners control unit Individual channel maintenance power-off Multilanguage graphic display operation. English, Chinese, Italian, German, Spanish. Individual channel flame raw signal outputs. AUTOTUNING function. On-line self-checking. Scalable 0 10 / 4 20 ma analogue outputs, isolated. Free programmable flame relays output logic CH1 &/OR/ CH2. Built in MODBUS standard driver. Multilevel power supply Detector temperature monitoring (TC input) The Uvisor MFD (Multi Fuel-flame Detector) is an advanced flame signal processor specifically designed for high safety / high performance application on industrial and large utility boilers. Uvisor MFD behaves as a true Two-Systemsin-One, processing simultaneously the flame signals carried by two scanner heads regardless the sensor spectral range (Ultraviolet or Infrared) or the electrical signal type (amplitude/frequency modulated signal or pulse rate signal). The unit is fail-safe by design and provides continuous diagnostic routines to verify the integrity of the sensors and associated detector circuitry. Uvisor MFD performs a continuous surveillance of the on-board and connected scanner head electronic circuitry. Relay drivers integrity is cyclically tested and flame relays contacts are fuse-protected to prevent sticking due to overload. External access to both detector channels as well as to the whole flame monitoring system is provided through MODBUS link allowing flame quality overview, diagnostic event list, historical trend and flame analysis. ABB

TECHNICAL DATA Power Supply Power consumption Ambient temperature operating: storage: 120 220 Vac +/- 20%, 45 65 Hz 24Vdc +/- 20% AC input: 30 VA (6A / 5 ms in-rush current) DC input: 22 W (24A / 2 ms in-rush current) 0 60 C (32 140 F) -25 85 C (-13 185 F) Enclosure Classification IP20 (NEMA 1) Dimensions 106 x 128 x 186 mm (w, h, d). See figure 3 Weight Approx. 1.2 Kg. (2.64 Lbs) Mounting Standard Rack 19. See figure 1 Electrical connections Channels Flame Relay Flame Failure Response Time Safe Relay Temperature alarm Analogue output Flame raw signal output Communication Diagnostic Temperature reading Setup files Display Configuration Compatible detector heads Two (2) connectors 16+16 male. Standard DIN 41612 F Row d z. Screw type. See figure 2 Two (2) self-configuring Pulse / Flicker. Maintenance power-off removes output power @ selected channel. Two (2) SPDT. VDE0110 Contact rating: 250 Vac 3 A 750 VA cosf. 0,4 220 Vdc 300 ma 66 W. Configurable from 1 through 5 seconds One (1) SPDT. VDE0110 Contact rating: 250 Vac 3 A 750 VA cosf. 0,4 220 Vdc 300 ma 66 W. One (1) SPST. VDE0110 Contact rating: 100 Vac 0.3A cosf 0.4 30W 4-20 ma / 0-10V programmable. Opto-isolated Scalable: +/-30dB, 0-30dB, 0-20dB Two (2) 0 dbv output level. One (1) RS485 Opto-isolated One (1) RS232 Opto-isolated Modbus slave protocol CPU < 500 ms Detector heads 5 second with UV tube sensors Internal: built-in External: TC J Four (4) each channel. Programmable through two (2) external free potential contacts or 24 Vdc logic inputs. Graphic. Language configurable menu. Available: Chinese, English, German, French, Italian, and Spanish. Auto power-off backlight Through panel soft keypad. Access code protection. Solid state: Uvisor UR600 IR Mod. 1000 Uvisor UR600 UV Mod. 1000 Uvisor UR600 UV-EXT Mod. 1000 Phototube: Uvisor UR450 Mod. 5002 UV Uvisor UR400/440 with UVPS adapter Dual sensor: Uvisor UR460 Mod. UVIR Approvals Electrical connection, see figures 4 through 7. CE FM In progress CSA In progress Page 2 of 8

DIMENSIONAL DIAGRAM Figure 1. 19 Rack mounting Figure 2. Rack mounting rear view 129 160 ABB 1 2 Set up Uvisor - MFD Esc 106 Enter Figure 3. Uvisor MFD side/front view Page 3 of 8

ELECTRICAL CONNECTIONS Figure 4. Uvisor MFD connection with two Uvisor scanners type UR600 IR/UV/UV-EXT Mod. 1000 Page 4 of 8

ELECTRICAL CONNECTIONS 4 conductor cable 20 AWG 4 conductor cable 20 AWG Figure 5. Uvisor MFD connection with two Uvisor scanners type UR450 Mod. 5002 UV Page 5 of 8

ELECTRICAL CONNECTIONS 4 conductor cable 20 AWG 4 conductor cable 20 AWG Figure 6. Uvisor MFD connection with one Uvisor scanner type UR600 IR/UV//UV-EXT Mod. 1000 and one type UR450 Mod. 5002 UV Page 6 of 8

ELECTRICAL CONNECTIONS 2 x 4 conductor cable 20 AWG Figure 7. Uvisor MFD connection with one Uvisor dual sensor scanner type UR460 UVIR Page 7 of 8

ORDERING DATA Purchase order must specify the full model number for each component of the system. PART NUMBER ORDERING CODE PRODUCT NAME DESCRIPTION Printed in Italy EC-BOM-G009HLA012 84503-S-2002000 Measure IT Uvisor MFD Multi flame detector - control unit EC-BOM-G009MEC008 84532-S-2002003 Rack Mounting Unit Four (4) slots mounting cage compatible with 19 racks, complete with guides, strips and screw-type rear connectors. EC-PI-G009UTL020-4_0.ZIP 84503-S-2002002 MFD Monitor Windows 9x, NT, 2000 EC-DWG-G009CBL032 84503-S-2002004 PC MFD serial cable Software for flame signal monitoring and archiving and flame frequency analysis. RS-232 serial cable to connect the Uvisor MFD to the PC communication port. EC-BOM-G009MEC028 84503-S-200-2001 Uvisor MFD Rack Adapter Plug-in adapter module to allow insertion of Uvisor MFD in a MFD.SA mounting cage. ABB For additional information contact: ABB Energy Automation, SpA Via Hermada 6 16154 Genova ITALY uvisor@it.abb.com The Industrial IT word mark and all above-mentioned product names in the form XXXXXXIT are registered or pending trademarks of ABB. MFD Data Sheet EC-DOC-G009DS012-C.DOC Page 8 of 8