R&S SGU100A SGMA Upconverter Specifications

Similar documents
R&S SGS100A SGMA RF Source Specifications

R&S ZN-Z154 Calibration Unit Specifications

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S SGMA Product Family Compact fast reliable

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S EDS300 DME/Pulse Analyzer Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

R&S GU221 Filter Control Unit Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S ZND Vector Network Analyzer Specifications

R&S AVG050 DVB Satellite Receiver Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S DST200 RF Diagnostic Chamber Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S ZNBT Vector Network Analyzer Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S RSC Step Attenuator Where precise signal levels count

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S RT-Zxx Standard Probes Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S EDST300 TACAN/DME Station Tester Specifications

R&S FPS-K18 Amplifier Measurements Specifications

EX-IQ-Box Digital Signal Interface Module Specifications

EUTRA/LTE Downlink Specifications

R&S SMF100A Microwave Signal Generator Specifications

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S FPC-Z10 Teaching Kit Getting Started

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

R&S BBL200 Broadband Amplifier Specifications

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

EUTRA/LTE Measurement Application Specifications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

R&S SMB100A RF and Microwave Signal Generator Specifications

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

R&S VSE Vector Signal Explorer Base Software Specifications

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S RT-ZM Modular Probe System

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S FPL1000 Spectrum Analyzer Specifications

R&S SGT100A SGMA Vector RF Source Specifications

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

R&S ZNL Vector Network Analyzer Specifications

RF amplifier testing from wafer to design-in

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

R&S SMB100B Signal Generator Specifications

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S NRP Power Sensor Family Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

Mastering Phase Noise Measurements (Part 3)

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

R&S CONTEST ITS Test cases and applications

DVG MPEG-2 Measurement Generator

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Scope of the art Scope Rider Handheld digital oscilloscope

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S VSE Vector Signal Explorer Base Software Specifications

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

Transcription:

R&S SGU100A SGMA Upconverter Specifications Test & Measurement Data Sheet 03.00

CONTENTS Key features... 3 Definitions... 4 Specifications... 5 RF performance... 5 Frequency... 5 Level... 5 Spectral purity... 7 LO input... 8 Phase coherence output... 8 Pulse modulation... 9 I/Q modulation... 9 I/Q modulator... 9 I/Q inputs... 10 I/Q outputs... 10 Remote control... 11 Connectors... 11 Rear panel connectors... 11 General data... 12 Ordering information... 13 2 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Key features Modular frequency extension unit with I/Q upconversion I/Q-modulated or pure LO frequency extension from 12 GHz to 40 GHz External software (R&S SGMA GUI) for remote control Vector modulated solution from 80 MHz to 40 GHz with R&S SGS100A acting as one combined instrument for manual and automated use once connected Extends existing analog Rohde & Schwarz signal generators (R&S SMF100A, R&S SMB100A) up to 40 GHz and adds vector modulation capabilities above 12 GHz Optional step attenuator with high dynamic range down to 120 dbm Space-saving operation due to small dimensions Only ½ 19", 1 HU Lightweight High performance at an attractive price Maximum output level of +21 dbm (typ.) (f = 20 GHz, with options R&S SGU-B120/-B120V and R&S SGU-B26) Maximum output level of +17 dbm (typ.) (f = 40 GHz, with options R&S SGU-B140/-B140V and R&S SGU-B26) Subharmonics of < 65 dbc (typ.) High RF modulation bandwidth of 2 GHz Very high level accuracy and linearity thanks to closed ALC loop, even with I/Q modulation Minimized total cost of ownership Attractive initial cost Long calibration interval of 3 years Simplified error diagnostics through built-in selftests Functional diagram of R&S SGU100A in combination with R&S SGS100A signal generator. Rohde & Schwarz R&S SGU100A SGMA Upconverter 3

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measured. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are indicated as follows: parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. 4 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Specifications RF performance Frequency Output frequency range Input frequency range Setting time with R&S SGU-B120, 10 MHz to 20 GHz R&S SGU-B120V options with R&S SGU-B140, 10 MHz to 40 GHz R&S SGU-B140V options For frequency settings below 12 GHz the 10 MHz to 12.75 GHz CW or modulated input signal is amplified and sent to the output of the instrument or to the optional step attenuator. For frequency settings > 12 GHz, the input CW signal is used to generate the I/Q modulator LO or CW output RF signal. to within < 2 10 7 for f > 500 MHz or < 100 Hz for f 500 MHz, without switching of mechanical step attenuator with PCIe remote control 1 < 2 ms Level Setting characteristic AUTO: The step attenuator is switched over automatically. This mode maximizes the specified level range. Setting characteristic uninterrupted level setting: The level is set without switching the step attenuator. The step attenuator is thus fixed to the current setting. Level changes are performed without interruption. The recommended interruption-free setting range is indicated by the instrument depending on the frequency, level and modulation settings. If this range is exceeded, the spectral purity of the output signal may decrease. Setting range 10 MHz f < 30 MHz 20 dbm to +12 dbm 30 MHz f < 50 MHz 20 dbm to +18 dbm f 50 MHz 20 dbm to +25 dbm instruments equipped with R&S SGU-B26 option 10 MHz f < 30 MHz 120 dbm to +12 dbm 30 MHz f < 50 MHz 120 dbm to +18 dbm f 50 MHz 120 dbm to +25 dbm Specified level range 1 instruments equipped with R&S SGU-B120 or R&S SGU-B120V, without option R&S SGU-B26 10 MHz < f 50 MHz (bypass mode) 10 dbm to +8 dbm (PEP) 50 MHz < f 12 GHz (bypass mode) 10 dbm to +15 dbm (PEP) 12 GHz < f 20 GHz 10 dbm to +17 dbm (PEP) with R&S SGU-B26 option 10 MHz < f 50 MHz (bypass mode) 100 dbm to +8 dbm (PEP) 50 MHz < f 12 GHz (bypass mode) 100 dbm to +13 dbm (PEP) 12 GHz < f 20 GHz 100 dbm to +15 dbm (PEP) instruments equipped with R&S SGU-B140 or R&S SGU-B140V, without option R&S SGU-B26 10 MHz < f 50 MHz (bypass mode) 10 dbm to +7 dbm (PEP) 50 MHz < f 12 GHz (bypass mode) 10 dbm to +13 dbm (PEP) 12 GHz < f 40 GHz 10 dbm to +15 dbm (PEP) with R&S SGU-B26 option 10 MHz < f 50 MHz (bypass mode) 100 dbm to +7 dbm (PEP) 50 MHz < f 12 GHz (bypass mode) 100 dbm to +11 dbm (PEP) 12 GHz < f 40 GHz 100 dbm to +13 dbm (PEP) Resolution of setting 0.01 db Rohde & Schwarz R&S SGU100A SGMA Upconverter 5

Level error 1 setting characteristic: AUTO, temperature range from +18 C to +33 C, CW or I/Q mode with full scale modulation 10 MHz < f 12 GHz < 0.9 db (meas.) 12 GHz < f 20 GHz > 30 dbm < 0.9 db 30 dbm < 1.1 db 20 GHz < f 40 GHz > 30 dbm < 0.9 db 70 dbm to 30 dbm < 1.1 db < 70 dbm < 1.5 db Additional level error 1 ALC state off (table) < 0.5 db (meas.) Output impedance VSWR instruments equipped with < 1.7 (meas.) in 50 Ω system 1 R&S SGU-B120 or R&S SGU-B120V with option R&S SGU-B26 < 1.7 (meas.) instruments equipped with < 2.0 (meas.) R&S SGU-B140 or R&S SGU-B140V with option R&S SGU-B26 < 1.8 (meas.) Setting time 1 to < 0.2 db deviation from final value, PCIe remote control without switching of mechanical step < 2 ms attenuator with switching of mechanical step < 25 ms attenuator Reverse power from 50 Ω maximum permissible RF power in output 0.5 W Maximum permissible DC voltage 0 V 26 25 24 23 22 21 20 Level / dbm 19 18 17 16 15 14 13 12 11 0 0.1 B120 B120, B26 B120, B140 B120, B140, B26 5 10 15 20 25 30 35 40 RF / GHz Maximum available level in combination with R&S SGS100A (meas.) 1 In combination with R&S SGS100A. 6 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Spectral purity Harmonics f > 12 GHz, level 8 dbm < 30 dbc Nonharmonics 2 level > 10 dbm, offset > 10 khz from carrier 12 GHz < f 20 GHz < 56 dbc (meas.) f > 20 GHz < 50 dbc (meas.) Subharmonics f > 12 GHz < 55 dbc, < 65 dbc (typ.) Wideband noise 2 carrier offset = 30 MHz, level = 10 dbm, measurement bandwidth 1 Hz instruments equipped with R&S SGU-B120 or R&S SGU-B120V CW, f 12 GHz < 140 dbc (meas.) CW, f > 12 GHz < 142 dbc vector modulation with full scale < 135 dbc, < 138 dbc (typ.) DC input, f > 12 GHz instruments equipped with R&S SGU-B140 or R&S SGU-B140V CW, f 12 GHz < 140 dbc (meas.) CW, 12 GHz < f 19.5 GHz < 142 dbc CW, f > 19.5 GHz < 136 dbc, < 139 dbc (typ.) vector modulation with full scale < 135 dbc, < 138 dbc (typ.) DC input, 12 GHz < f 19.5 GHz vector modulation with full scale < 134 dbc, < 137 dbc (typ.) DC input, f > 19.5 GHz SSB phase noise in combination with R&S SGS100A (meas.) 2 In combination with R&S SGS100A. Rohde & Schwarz R&S SGU100A SGMA Upconverter 7

LO input For frequency settings > 12 GHz, the local oscillator signal for the I/Q modulator of the R&S SGU100A is derived from the RF signal fed into the LO input. CW or modulated signals up to 12 GHz can also be amplified and bypassed from LO input to the RF output of the instrument or to the optional step attenuator. Input frequency range instruments with R&S SGU-B120 or R&S SGU-B120V 10 MHz f 12 GHz, 10 MHz to 12 GHz bypass operation, CW or modulated 12 GHz < f 12.75 GHz 12 GHz to 12.75 GHz 12.75 GHz < f 20 GHz 6.375 GHz to 10 GHz instruments equipped with R&S SGU-B140 or R&S SGU-B140V 10 MHz f 12 GHz, 10 MHz to 12 GHz bypass operation, CW or modulated 12 GHz < f 12.75 GHz 12 GHz to 12.75 GHz 12.75 GHz < f 25.5 GHz 6.375 GHz to 12.75 GHz 25.5 GHz < f 40 GHz 6.375 GHz to 10 GHz Connector type LO IN on rear panel SMA female Input impedance 50 Ω (nom.) Input level range upconverter operation, f > 12 GHz +7 dbm to +13 dbm Input damage level upconverter operation, f > 12 GHz +18 dbm bypass operation, f 12 GHz +25 dbm Phase coherence output The R&S SGU100A provides a phase coherent LO output signal. At instruments equipped with frequency option R&S SGU-B140 or R&S SGU-B140V, the LO output signal is set to the half output frequency for frequencies above 19.5 GHz. Output frequency range instruments with R&S SGU-B120 or R&S SGU-B120V upconverter operation, 12 GHz to 20 GHz 12 GHz < f 20 GHz instruments equipped with R&S SGU-B140 or R&S SGU-B140V upconverter operation, 12 GHz to 19.5 GHz 12 GHz < f 19.5 GHz upconverter operation, 9.75 GHz to 20 GHz 19.5 GHz < f 40 GHz Connector type LO OUT on rear panel SMA female Output impedance 50 Ω (nom.) Output level range +7 dbm to +13 dbm 8 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Pulse modulation The R&S SGU-B120 and R&S SGU-B120V options include an internal pulse modulator for the frequency range from 12 GHz to 20 GHz. For frequencies lower than 12 GHz, pulse modulation on the RF signal provided on the LO input is transferred to the RF output. Instruments equipped with R&S SGU-B140 or R&S SGU-B140V include an internal pulse modulator for the frequency range from 12 GHz to 19.5 GHz. For frequencies from 19.5 GHz to 40 GHz, pulse modulation of the output signal can be accomplished by feeding an externally pulse modulated LO signal to the LO input of the instrument. Once the R&S SGU100A is connected to an R&S SGS100A with pulse modulation capability, the required settings to realize internal and external pulse modulation over the full frequency range are automatically performed. Modulation source external Connector type TRIG on rear panel SMA female Input impedance 50 Ω (nom.), 10 kω (nom.) On/off ratio 3 > 80 db Rise/fall time 3 10 %/90 % of RF amplitude < 20 ns Pulse repetition frequency 3 0 Hz to 10 MHz Video feedthrough 3 setting characteristic: AUTO level < 10 dbm < 10 % of RF with R&S SGU-B26 option level > 3 dbm and < 12 dbm < 10 % of RF without R&S SGU-B26 option Pulse overshoot 3 < 10 % I/Q modulation I/Q modulator Modulation bandwidth f > 12 GHz up to ±1000 MHz RF frequency response up to ± 100 MHz < 2 db (meas.) up to ±1000 MHz < 6 db (meas.) Carrier leakage without input signal, referenced to < 35 dbc, < 45 dbc (typ.) full-scale input 4 Suppression of image sideband up to ±10 MHz 4 40 db (meas.) Error vector 5 measured with 16QAM, filter root cosine, α = 0.5, symbol rate 10 MHz f > 12 GHz, RMS < (2 % + 0.04 % f/ghz) f > 12 GHz, peak value < (5 % + 0.1 % f/ghz) Two tone IMD (2 carriers) level (PEP) = 0 dbm, up to 80 MHz carrier spacing 12 GHz < f 19.5 GHz < 40 dbc (typ.) 19.5 GHz < f 30 GHz < 38 dbc (typ.) 30 GHz < f 40 GHz < 32 dbc (typ.) I/Q impairment settings Offset setting range 5 % to +5 % Offset setting resolution 0.01 % Gain imbalance setting range 1.0 db to +1.0 db Gain imbalance setting resolution 0.01 db Quadrature offset setting range 8 to +8 Quadrature offset setting resolution 0.01 3 In frequency range of internal pulse modulator 4 Value applies after internal readjustment. 5 In combination with R&S SGS100A. Rohde & Schwarz R&S SGU100A SGMA Upconverter 9

I/Q inputs Connector types I in, Q in on rear panel SMA female Input impedance 50 Ω (nom.) VSWR f > 12 GHz up to 100 MHz < 1.3 100 MHz up to 1000 MHz < 1.5 Input voltage for full scale input 2 2 Vi + Vq = 0.5 V Input damage voltage electronic input protection ± 5 V (nom.) I/Q outputs Allows routing of I and Q baseband signals to R&S SGS100A for I/Q modulation below 12 GHz Connector types I out, Q out on rear panel SMA female Output impedance 50 Ω (nom.) Losses in feedthrough path < 2 db (meas.) I/Q-Frequency Response [db] 5 4 3 2 1 0-1 -2 CF = 12 GHz CF = 15 GHz CF = 18 GHz CF = 22 GHz CF = 26 GHz CF = 30 GHz CF = 34 GHz CF = 39 GHz -3-4 -5-1000 -800-600 -400-200 0 200 400 600 800 1000 Offset Frequency [MHz] I/Q modulation frequency response at various carrier frequencies (meas.) 10 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Remote control Systems PCIe (single lane) Ethernet (TCP/IP) 10/100/1000 Base-T USB 2.0 Command set remote control via Ethernet, USB SCPI 1999.5 or compatible command sets remote control via PCIe Rohde & Schwarz instrument driver Connectors Rear panel connectors RF 50 Ω RF output K female LO IN RF/LO input SMA female LO OUT coherent LO output signal SMA female I in, Q in input connector for I and Q baseband SMA female signals I out, Q out output connector for I and Q baseband SMA female signals (to R&S SGS100A) TRIG trigger input/output, pulse input SMA female USB IN remote control of instrument USB (micro USB, type B) LAN remote control of instrument RJ-45 PCIe remote control of instrument single lane Rohde & Schwarz R&S SGU100A SGMA Upconverter 11

General data Power supply Input voltage range AC 100 V to 240 V ± 10 % Supply frequency AC 50 Hz to 60 Hz, 5 %/+5 % Max. input current 1.7 A Power consumption instruments equipped with 40 W (meas.) R&S SGU-B120 or R&S SGU-B120V instruments equipped with 70 W (meas.) R&S SGU-B140 or R&S SGU-B140V Power factor correction in line with EN 61000-3-2 Electrical safety Compliance in line with IEC 61010-1, EN 61010-1, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1 Test mark VDE-GS, CCSA US EMC Electromagnetic compatibility in line with EN 55011 class A, EN 61326-1 (industrial environment), EN 61326-2-1 Mechanical resistance Vibration sinusoidal 5 Hz to 150 Hz, max. 2 g at 55 Hz, const. 0.5 g at 55 Hz to 150 Hz, in line with EN 60068-2-6 random 10 Hz to 300 Hz, acceleration 1.2 g RMS, in line with EN 60068-2-64 Shock 40 g shock spectrum, in line with MIL-STD-810E, method no. 516.4, procedure I, Environmental conditions Temperature range operating 0 C to +50 C in line with EN 60068-2-1, EN 60068-2-2 storage 40 C to +71 C Climatic resistance +40 C/95 % rel. humidity, in line with EN 60068-2-30 Altitude operating up to 4600 m storage up to 4600 m Dimensions W H D 250 mm 52.5 mm 401 mm (9.84 in 2.07 in 15.79 in) 1 HU, ½ 19" rack width Weight when fully equipped 4.0 kg (8.82 lb) (nom.) Calibration interval Recommended calibration interval operation 40 h/week in the full range of the specified environmental conditions 3 years 12 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Ordering information Designation Type Order No. SGMA Upconverter, base unit 6 R&S SGU100A 1418.2005.02 Including power cable, quick start guide and CD-ROM (with operating and service manual) Options 10 MHz to 20 GHz, CW (without vector modulation) R&S SGU-B120 1418.2605.02 10 MHz to 20 GHz, I/Q (with vector modulation) R&S SGU-B120V 1418.2657.02 Frequency Extension to 40 GHz, CW R&S SGU-B140 1418.2870.02 Frequency Extension to 40 GHz, I/Q R&S SGU-B140V 1418.2928.02 Mechanical Step Attenuator R&S SGU-B26 1418.3401.02 Documentation of Calibration Values R&S DCV-2 0240.2193.18 Recommended extras Hardcopy manuals (in English) 1418.2070.02 Cable Kit R&S SGU100A to R&S SGS100A (side-by-side) R&S SGU-Z3 1418.3801.02 Connection Kit R&S SGU100A to R&S SGS100A R&S SGU-Z4 1418.3701.02 R&S SGMA Adapter R&S SGS-Z8 1416.2914.02 19" Rack Adapter R&S ZZA-KN20 1175.3191.00 (for two 1 HU instruments next to each other), suitable for installation of two SGMA instruments 19" Rack Adapter (for one instrument + spacing module) R&S ZZA-KN21 1175.3204.00 Service options Extended Warranty, one year R&S WE1 Please contact your local Extended Warranty, two years R&S WE2 Rohde & Schwarz sales Extended Warranty, three years R&S WE3 office. Extended Warranty, four years R&S WE4 Extended Warranty with Calibration Coverage, one year R&S CW1 Extended Warranty with Calibration Coverage, two years R&S CW2 Extended Warranty with Calibration Coverage, three years R&S CW3 Extended Warranty with Calibration Coverage, four years R&S CW4 Extended warranty with a term of one to four years (WE1 to WE4) Repairs carried out during the contract term are free of charge 7. Necessary calibration and adjustments carried out during repairs are also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top condition a couple of days later. Extended warranty with calibration (CW1 to CW4) Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs 7 and calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades. 6 The base unit must be ordered together with an R&S SGU-B120 or R&S SGU-B120V frequency option. 7 Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included. Rohde & Schwarz R&S SGU100A SGMA Upconverter 13

14 Rohde & Schwarz R&S SGU100A SGMA Upconverter

Rohde & Schwarz R&S SGU100A SGMA Upconverter 15

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group is a leading supplier of solutions in the fields of test and measurement, broadcasting, secure communications, and radiomonitoring and radiolocation. Founded more than 80 years ago, this independent global company has an extensive sales network and is present in more than 70 countries. The company is headquartered in Munich, Germany. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 3606.9779.22 Version 03.00 January 2017 (GK) R&S SGU100A SGMA Upconverter Data without tolerance limits is not binding Subject to change 20142017 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 3606.9779.22 03.00 PDP 1 en 3606977922