FOREST SHUTTLE S / L / M RECEIVER

Similar documents
Installing the FOREST SHUTTLE S / L

Read these instructions carefully before using the Forest Shuttle, FMS and BCS motors and save them for future reference.

ASP-FIBRS1 User Manual

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

VLHDMIEXTFIB_2017V1.0

Environmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Operating Manual. Basic Control BC16. two-channel for eco moon

LIGHT COPILOT II. elationlighting.com Internet:

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

Sprite TL Quick Start Guide

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

A Motor can be in many groups, by assigning additional channel# on it.

Series CT7N Bimetallic Overload Relays

Figure 1: Device components

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

TeamWork Kits Installation Guide

Noise Detector ND-1 Operating Manual

Elite Silvermax Series

1440/2880 HP RGB+WW+CW

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

ipump 622 Streaming Media Decoder Installation Quick Start Guide

Spectra Batten (Order code: LEDJ95)

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

NS-3 RF Noise Source Operation Manual

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

COLORtube EQ Controller

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

FD Trinitron Colour Television

Galaxias. Flex LED display. User Manual

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

EZ-LIGHT K30L Series With Independent Push Button Contact

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

User Guide. Centrex Recording Interface

User s Guide. 5.8GHz Wireless A/V Signal Sender

OSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

XTENDEX Series. ST-C6DVI(A)-300 ST-C6DVI(A)-IR FOOT DVI VIDEO, AUDIO AND IR EXTENDER Installation and Operation Manual

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Sensor technologies Proximity sensors Series ST4. Brochure

ZIG-POEPRO-70A. HDBaseT HDMI Extender

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

Quick Reference Guide

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

USER MANUAL FOR CABLE RECEIVER KAON KCF-200CO KAON KCF-H220SCO

User Manual TPHD-BYE. HDBaseT Extender Set 70m. All Rights Reserved. Version: TPHD-BYE_2014V1.0

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Datasheet - SRB-E-201ST

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

LED Thunder S-150 Code 1097

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

Perle Fast Ethernet Media Converters

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

PSM-003. Micro Polarization Controller/Scrambler. User Guide

AS09..S 3-pole Contactors - Spring Terminals

PRINCIPLES AND APPLICATIONS

EXT-HBT70-SET_2016V1.2

FOM-9010, FOM-9011 and FOM-9012

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Multicom Optical Return Path Receiver MUL HRPR 4B

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

CAMTO LTD. Arc detecting system DC/AC

Truss Light COB LED 30W

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Instruction Manual Model BlockUpconverter

Process Transmitter RMA 422

User Manual TP422P-4K. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TP422P-4K_2016V1.1

PAM-1840 Preamplifier Operation Manual

Photoelectrics Through-beam Type PA18C.T..., DC

Integre4. Audiophile integrated amplifier. v1.2

Mini LED Pin Spot Light Model: PLS00571

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

User manual. Goodmans Product Information:

High performance circuit breakers

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Telemetry Receiver Installation Guide

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Indoor/Outdoor Security System with Quad Monitor User s Manual

Instruction Manual 1T-CT-630 Series HDMI to CAT.6 Extender System

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

Transcription:

2 FOREST SHUTTLE S / L / M RECEIVER

QUICK INSTALLATION OF ASSEMBLED TRACKS : Programming Shuttle S / L / M Receiver to a channel One pre-assembled motorized curtain track systems is standard programmed to channel 1 of the remote control. When several motorized systems are pre-assembled, the systems are only programmed to a channel when this is mentioned on the order form. So it is possible that you have to program the systems to the remote control. It is not necessary to fix the Shuttle L motor to the track for programming a channel to a Shuttle L motor. Take next steps: FIRST SELECT THE PRESS BUTTON 3x LED MOVES FROM KEEP BUTTON GREEN LED WITHIN 10 SEC. DESIRES CHANNEL WITH A PEN 1 st 2 nd 3 rd LED PRESSED FOR 5 SEC. STARTS BLINKING PRESS OPEN 3x 1x 5sec. Re-adjusting the open and close end position The OPEN and CLOSE end positions are a ready set to the curtain track. Adding extra carriers is taken into account. When the end positions need to be changed, take next steps: MOVE THE CURTAIN TO THE OPEN POSITION PRESS BUTTON 4x LED MOVES FROM KEEP BUTTON YELLOW LED BLINKS WITH A PEN 1 st 2 nd 3 rd 4 th LED PRESSED FOR 5 SEC. AND GOES OFF 4x 1x for 5sec. Now the end positions are reset and have to be set again: PRESS THE CURTAIN TOWARDS CLOSE POSITION, CURTAIN WILL CLOSE AUTOMATIC. PRESS THE CURTAIN TOWARDS OPEN POSITION, CURTAIN WILL OPEN AUTOMATIC. DIRECTLY AFTER STOPPING OF THE MOTOR (AT OPEN POSITION) THE YELLOW LED WILL LIGHT UP. NOW YOU CAN ADJUST THE OPEN POSITION TO DESIRED POSITION. WAIT UNTIL THE YELLOW LED GOES OFF, THE END POSITIONS ARE NOW STORED INTO MEMORY. 2 Installing the Forest Shuttle S / L / M Receiver

Installing the FOREST SHUTTLE S / L / M Receiver 1 Assemble the track 2 Install the brackets and fix the track onto the brackets 3 Do not attach the drapery yet. Attach the drapery only after the end positions have been set. position the master carrier(s) into half open position 4 Attach the motor to the track make sure to secure the locking pin into the motor pulley 5 Shuttle L: Shuttle S / M Receiver: fix adaptor onto Shuttle or wall Connect the AC plug (100-240V~) to the power socket of Shuttle L Connect the 24V plug into the socket of the Shuttle S / M Rec and connect the AC plug to the wall socket. loop the cord through the strain relief 3 Installing the Forest Shuttle S / L / M Receiver

6 Setting the end limits of the FOREST SHUTTLE S / L / M Receiver Before setting the end limits, the RF remote or IR remote channel can be programmed. The stack back (adjusted open limit) can be set by remote or switch. For programming see page 5. SETTING MOTOR DIRECTION AND CLOSE LIMIT: The Shuttle detects automatically the motor direction. By pulling the master carrier(s) towards closed position first, the Shuttle will automatically learn that motor direction. The master carrier will travel automatically towards the closed position. SETTING OPEN LIMIT: When the closed position is reached, that end limit is set. Pull the master carrier(s) to the open position. The master carrier(s) will travel automatically towards the open position. Stack back: When the master carrier reaches the fully open position it will stop (yellow LED4 is on). Now the open limit setting can be adjusted by hand, by remote or dry contact input. When the master carrier is not moved for 10 seconds, the yellow LED4 will go off and the open limit is set. The minimal automatic adjustment is 3 cm (1.2 ). If you are not satisfied with the programmed end limits, then re-set the end limits as shown in the configuration table on page 5 and proceed from step 6 4 Installing the Forest Shuttle S / L / M Receiver

Configure the FOREST SHUTTLE S / L / M Receiver Bottom view of the Shuttle Use a pin to change settings in the configuration menu. Choose the setting you want to change (table below) and press the button that many times (corresponding with setting). LED1 LED2 LED3 LED4 configuration button Confirm the desired setting by pressing the button for 4 seconds until the led blinks 3 times and goes OFF. These settings can also be done when finishing the installation. Speed (1 & 2): Standard speed is 14cm/s. For faster speed, 17cm/s, press 2x button. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. Programming RF remote channel (3): To programming a RF remote to a Shuttle, press configuration button 3 times. LED3 is ON. Press and hold once more for 4 seconds, LED will start blinking for 10 seconds. In these 10 seconds press OPEN button on remote to program the channel to the Shuttle. Same procedure, but press CLOSE instead of OPEN, will erase the programmed channel. Reset end limits (4): For resetting only the end limits: press button 4x. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. Dry contact inputs (5, 6 & 7): Standard input is pulse contact. To set to continuous or single switch, press button 6 or 7 times respectively. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. Please see page 6 for detailed explanation. Make sure the contact is free of potential. Touch Impulse (8, 9 & 10): The Shuttle recognizes when the curtain is pulled by hand to open or close. The Shuttle will then open or close the curtain all the way. Default setting is high sensitive. Touch Impulse can be set to less sensitive or off, with 9 or 10 presses respectively. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. IR channel setting (11, 12, 13, 14 & 15): For Infra Red control an IR remote and an IR receiver is required, connected to port 1. Place the eye of the receiver cord in view of the IR remote. Standard the Shuttle is set to channel 1 and ALL. To change to channel 2, 3 4 or 5, press resp. 12x, 13x, 14x or 15x button. Press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. Factory default (16) To reset all settings, press button 16x. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. 5 Installing the Forest Shuttle S / L / M Receiver

Connecting to port 1 or port 2 of the FOREST SHUTTLE S / L / M Receiver do-it-yourself plug pin8 pin1 (CLOSE) (OPEN) pin8 pin1 (CLOSE) (OPEN) MANUAL SWITCH CONNECTED TO DRY CONTACT INPUTS A manual switch or a relay output of a Home Automation System can easily be connected to the Shuttle. Be sure the switch/relay is potential free. Use pins 1, 3 and 8 of PORT1 or PORT2. OPEN: when pin 1 is connected to pin 3 (COMMON) the Shuttle will open the curtain. CLOSE: when pin 8 is connected to pin 3 (COMMON) the Shuttle will close the curtain. STOP: when pin 1 and 8 are connected to pin 3 (COMMON) the Shuttle will stop moving the curtain. Different modes can be set: - Pulse: when short contact is made the curtain will open or close fully (default setting) - Continuous: the curtain will move as long as the contact is made (mostly used for Home Automation Systems) - Single button switch (door bell principle): either one of the four inputs will act as following: open stop close stop open stop close stop etc. To change this setting see page 5. Shuttle S / L / M Receiver (Shuttle S and M only) 6 Installing the Forest Shuttle S / L / M Receiver

Programming Master Slave function to the FOREST SHUTTLE M Receiver The Forest Shuttle M Receiver can be programmed as MASTER and SLAVE motor. Two motors are needed, connected together by a cable from Port 1 to Port 1. Configuration can be done by means of pressing the configuration button on the Shuttle motors: Situation 1 (normal Shuttle M Receiver 5232000003): LED 1 to 4 Two Shuttle motors on one track (direction of rotation is the same). Installation steps: - install the track, motors and power plug - connect motor A, port 1 to motor B, port 1 by means of a 8 wire flat cable, UTP or FTP (straight) cable. - program the MASTER motor: Press the configuration button 17 times shortly, LEDS 1 to 4 will move with every press. After 17 presses, once more press the button and hold for 4 seconds. LED 1 will blink three times and go off. - program the SLAVE motor: Press the configuration button 18 times shortly, LEDS 1 to 4 will move with every press. After 18 presses, once more press the button and hold for 4 seconds. LED 2 will blink three times and go off. - Now the SLAVE motor will follow the movement of the MASTER motor. Only the MASTER motor can be controlled. - End limits can be set now and remotes can be programmed. Situation 2 (FSS Shuttle M Receiver 7131000000): Two Shuttle motors drive a Forest Skylight System FSS (direction of rotation is opposite). Installation steps: - install the track, motors and power plug - connect motor A, port 1 to motor B, port 1 by means of a 8 wire flat cable, UTP or FTP (straight) cable. - program the MASTER motor: Press the configuration button 17 times shortly, LEDS 1 to 4 will move with every press. After 17 presses, once more press the button and hold for 4 seconds. LED 1 will blink three times and go off. - program the SLAVE motor: Press the configuration button 19 times shortly, LEDS 1 to 4 will move with every press. After 19 presses, once more press the button and hold for 4 seconds. LED 3 will blink three times and go off. - For both motors: press configuration button 26 times, after that press 4 time for 4 sec. to confirm - Now the SLAVE motor will follow the movement of the MASTER motor. Only the MASTER motor can be controlled. - End limits can be set now and remotes can be programmed now. It will be hard to move the curtain by hand, because of the solid coupling inside the FSS motor. This is normal. 7 Installing the Forest Shuttle S / L / M Receiver

Technical specification of the FOREST SHUTTLE S / L / M Receiver Shuttle S Shuttle M Receiver Shuttle L Part # 5232000000 5232000003 5232000001 Voltage Shuttle : 24Vdc 24Vdc 100-240V~ 50-60Hz 0.8A Max. power: 40W 72W 40W Torque: 1Nm 1.5Nm 1Nm Speed 1: 14 cm/s 14cm/s 14 cm/s Speed 2: 17 cm/s 17cm/s 17 cm/s Max. curtain weight: 40kg (no curves) 70kg (no curves) 40kg (no curves) Length: 20cm (7.9 ) 25 (10 ) 28cm (11 ) Net. weight motor: 700 gr. 980gr. 930 gr. Protection degree: IP20 IP20 IP20 Max. running time (in one direction): 240 sec. 240 sec. 240 sec. Sound level: < 40dB <40dB < 40dB Ambient temperature: 0-40⁰C (32-104⁰F) 0-40⁰C (32-104⁰F) 0-40⁰C (32-104⁰F) Relative humidity: 10 80% 10 80% 10 80% Maximum useable altitude above sea level: 2000m (6561ft.) 2000m (6561ft.) 2000m (6561ft.) Certification & Marking: CE CE CE TECHNICAL SPECIFICATION POWER SUPPLY: Shuttle S: Shuttle M Receiver: Model: ZDA240150 ZF120A-2403000 Voltage input: 100-240V~ 50-60Hz 0.8A 100-240V~ 50-60Hz 1.2A Voltage output: 24Vdc 24Vdc Insulation class: II II Certification & Marking: CE, culus, FCC, CCC CE, culus, FCC, CCC If another power supply is used or a central power supply, each Shuttle S must be protected with a 2.5A slow fuse. Each Shuttle M Receiver must be protected with a 4A slow fuse. H B1 B2 Shuttle S 225mm 77mm 49mm Shuttle MRec 270mm 77mm 49mm Shuttle L 305mm 77mm 49mm 8 Installing the Forest Shuttle S / L / M Receiver

Forest Shuttle S / L / M Receiver is not suitable for humid spaces, like bathrooms or outdoors. It is important for the safety of persons to follow these instructions. Save these instructions. Do not use the product for any other purpose than intended. In order for the Forest Shuttle S / L / M Receiver to function correct and safe, the complete curtain system must be assembled with original parts and devices of Forest Drapery Hardware. This includes all components of the curtain track and power supply adaptor. Forest does not assume liability for resulting damages to property or personal injury, defects, labor on location, service calls, reinstallation or expenses involved shipping, packing or returning goods, if the product has been abused/modified in any way or damaged by improper use or failure to observe these operating instructions. The warranty/guarantee will then expire. Do not allow children to play with the system or controls. Keep remote controls away from children. Frequently examine the installation for imbalance and signs of wear or damage. Do not use if repair or adjustment is necessary. 9 Installing the Forest Shuttle S / L / M Receiver v1_6