DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

ScopeMeter 190 Series Specifications

Digital Storage Oscilloscopes 2550 Series

Expect to Make Waves.

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

2016 RIGOL TECHNOLOGIES, INC.

PicoScope 6407 Digitizer

PicoScope 6407 Digitizer

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

PORTABLE OSCILLOSCOPE

Agilent Technologies 54522A

Portable Performance for Debug and Validation

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Selection Table. Ordering Information

HX0074 DEMO Kit for METRIX Oscilloscopes

PicoScope 2000 Series PC Oscilloscopes

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

OSCILLOSCOPES-ANALYZERS

SDS1000C Specifications

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

PicoScope 4000 Series PC Oscilloscopes


PicoScope 3000 Series Automotive User guide

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

Oscilloscopes for field applications

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

PicoScope 4000 Automotive PC Oscilloscopes

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s

Broadcast Television Measurements

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

R3267/3273 Spectrum Analyzers

Oscilloscopes for field applications

Advanced Test Equipment Rentals ATEC (2832)

DataSheet. SDS1000DL Series Digital Oscilloscope

2 MHz Lock-In Amplifier

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

High Speed Data Acquisition Cards

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

50 MHz Digital Storage Oscilloscope

What to look for when choosing an oscilloscope

Data Pattern Generator DG2020A Data Sheet

User Manual. TDS3SDI 601 Digital Video Application Module

PicoScope 3000 Series PC Oscilloscopes

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Operating Instructions

Advanced Test Equipment Rentals ATEC (2832)

imso-104 Manual Revised July 19, 2012

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

Digital Phosphor Oscilloscopes

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

LeCroy Digital Oscilloscopes

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Data Pattern Generator

OX 863B 150 MHz PORTABLE OSCILLOSCOPE User s manual

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

MICROWAVE MEASURING INSTRUMENTS

PicoScope 4000 Series PC Oscilloscopes

DIGITAL OSCILLOSCOPES

Microwave Counter, Power Meter and DVM in One Portable Package

Agilent E5100A Network Analyzer

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

Oscilloscopes, logic analyzers ScopeLogicDAQ

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

DataSheet SDS1000CML Series Digital Oscilloscope

GFT Channel Digital Delay Generator

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

100 MHz, 100 MS/s, 14-Bit Digitizer

Programmable Power Supplies 188 W 384 W R&S HMP Series

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

DataSheet SDS1000CFL Series Digital Oscilloscope

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

PicoScope 2203, 2204, 2205 PC Oscilloscopes

ADS1000C, CAL / CML Series

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Analog Dual-Standard Waveform Monitor

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

Agilent 5345A Universal Counter, 500 MHz

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

Transcription:

SX-METRO A software package to meet all your needs SX-METRO Software Front panel contact software The OX 863 and the OX 803 can be fitted with an RS232 interface (option) for controlling and programming their front panels via a PC. The software can run from MS-DOS or Windows. The oscilloscope can then be remote controlled, using the front panel displayed on the PC and the mouse or automation software. Analysis SX-METRO enables you to display curves (definable display window, scale, graticule and cursor options,...) and to carry our mathematical routines such as the FFT of the displayed signal (windowing and zoom of result, Y scale of FFT in volts or db, measurements by markers). Oscilloscope communications This software is used to import curves stored in the oscilloscope's memory and "picture" files or to load a configuration into the instrument, via the RS232 or IEEE interfaces. Archiving Curves, stored in ASCII files, can be displayed on the screen and printed, as and when required, or instrument configurations can be reloaded. FFT: display of signal (CH1 or CH2) and its Fourier transform (module). Window and zoom possibilities are provided, together with a cursor on FFT, enabling the frequency and amplitude (v or db) to be measured. Documentation and processing With the SX-METRO software, you can transfer data (curve or FFT) easily to Excel. Accordingly, you can insert a signal graph into a report printed in Word or carry out additional mathematical calculations on curve samples. SX- METRO software Minimum configuration MS-DOS version 3.1 or higher Microsoft Windows 3.1, Windows 95/98, Windows NT,... PC or 80386-compatible computer or higher and clock speed of at least 25MHz. (80486 33MHz recommended) VGA resolution (or higher) Math coprocessor At least 4Mb RAM, 8Mb recommended Approx. 30Mb of free hard disk capacity Model SX-METRO accessories and Ordering Information SX-METRO acquisition software for OX8020, OX8042, OX8050, OX8062 and OX8100 RS Stock No SX-METRO 339-6483 Accessories included The SX-METRO kit contains 1 diskette, 1 PC/oscilloscope serial link lead, 1 25/9pin adaptor, a gender changer and a user's manual. Furthermore a free demo of this software is included with every combined analogue/digital oscilloscope ordered from RS Components. Selection of channels to be displayed: the index pointed shows the selection, CH1 & CH2 (XY). Other possibilities CH1, CH2 or CH1 & CH2.

SP E C I F I CAT I O N S Products OX8100 OX8050 OX8040 OX8062 OX8042 OX822 OX863 OX803 OX530 VERTICAL DEFLECTION Bandwidth Analog 100MHz Analog 40MHz Analog 20MHz Analog 30MHz Analog 20MHz Analog 20MHz Analog 100MHz Analog 40MHz Analog 30MHz Digital 60MHz Digital 30MHz Digital 60Mhz Digital 40Mhz Number of channels 2 2 2 2 differentials. 2 differentials. 2 differentials. 2 2 2 2 BNC per channel 2 BNC per channel 2 BNC per channel Input impedance 1 Mohms/15pF 1 Mohms/25pF 1 Mohms/25pF 1 Mohms/12pF 1 Mohms/12pF 1 Mohms/12pF 1 Mohms/15pF 1 Mohms/25pF 1 Mohms/25pF Maximum input voltage 400V 400V 400V 600V differential 600V differential 600V differential 400 V 400V 400V Sensitivity 2mV to 5V/div. ImV to 20V/div. ImV to 20V/div. 10mV / 200V/div 10mV / 200V/div 10mV / 200V/div 2mV to 5V/div. 1mV to 20V/div 5mV to 20V/div Continuous gain adjustment 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 1 to 2.5 Operating modes CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, -CH2, CH1, CH2, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, ALT, CHOP, ADD, -CH2, XY, ALT, XY, MULT, BWL XY, MULT XY, MULT XY XY XY XY XY CHOP Component Tester 1kHz 1Vpk-pk signal HORIZONTAL DEFLECTION Time Base 2 1 + delay 1 + delay 1 + delay 1 + delay 1 + delay 1 + delay 1 1 Sweep speeds (Analog) 50ns/100ms/div 50ns/100ms/div 50ns/100ms/div 50ns/200ms/div 50ns/200ms/div 50ns/200ms/div 50ns/100ms/div 50ns/200ms/div 50ns/200ms/div Sweep speeds (Digital) 5ns/200s/div. 5ns/200s/div. 5ns/200s/div. 5ns/200s/div. 5ns/200s/div. XY mode 4MHz 2MHz 2MHz 2MHz 2MHz 2MHz 4MHz 2MHz 2MHz TRIGGERING TV trigger PAL, SECAM, NTSC. PAL, SECAM, NTSC. PAL, SECAM, NTSC. Frame & Line with Frame & Line with Frame & Line with Frame and Line. Frame and Line Frame and Line With Line counting With Line counting With Line counting true differential true differential true differential Also Trigger on line external trigger external trigger external trigger number. 1 to 1250 Source CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT CH 1 CH 2 ALT LINE, EXT LINE, EXT LINE, EXT LINE, EXT LINE, EXT LINE, EXT LINE, EXT LINE, EXT LINE, EXT DIGITAL MEMORY Sampling frequency 100 MS/s 100 MS/s 100 MS/s 100 MS/s 100 MS/s (Single Shot) Equivalent Time Sampling 20 GS/s 20 GS/s 20 GS/s 20 GS/s 20 GS/s Record Length 2 x (1, 8 or 16 k) 2 x (1, 8 or 16 k) 2 x (1, 8 or 16 k) 2 x (1, 8 or 16 k) 2 x (1, 8 or 16 k) Vertical resolution 8 bits 8 bits 8 bits 8 bits 8 bits FFT and Harmonic analysis Yes Yes Yes Yes Yes Converters 2 2 2 2 2 Glitch Mode 20 ns 20 ns 20 ns 20 ns 20 ns Envelope Mode Yes Yes Yes Yes Yes Trigger Roll Mode Yes Yes Yes Yes Yes XY Digital Mode 100 MHz 60 MHz 60 MHz 20 MHz 20 MHz SPECIFIC FEATURES AUTOSET Yes Yes Yes Yes Yes Yes Yes Yes Yes Probe ratio compensation 1/1, 1/10, 1/100 1/1, 1/10, 1/100 1/1, 1/10, 1/100 1/1, 1/10, 1/100 1/1, 1/10, 1/100 1/1, 1/10, 1/100 Automatic measurements 17 Maths Functions 17 Maths Functions 17 Maths Functions 17 Maths Functions 17 Maths Functions Measurement cursors Vt, 1/t, phase Vt, 1/t, phase Vt, 1/t, phase Vt, 1/t, phase Vt, 1/t, phase Vt, 1/t, phase GENERAL SPECIFICATIONS Display type CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm CRT 8x10cm Interfaces RS232 & Centronics RS232 & Centronics RS232 & Centronics RS232 & Centronics RS232 & Centronics RS232 (option) RS232 (option) RS232 (option) (IEEE option) (IEEE option) (IEEE option) Power supply 96 to 264V, 96 to 264V, 96 to 264V, 110-230V / 110-230V / 110-230V / 94 to 264Volts 94 to 264Volts 94 to 264Volts 45/440 Hz 45/440Hz 45/440Hz 50-60Hz 50-60Hz 50-60Hz 48/440Hz 48/440Hz 48/440Hz Dimensions 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm 450 x 340 x 155mm Weight 7kg 5.5kg 5.5kg 7kg 7kg 6.5kg 6.0kg 6.3kg 5.5kg IEC 61010 Safety Cat. II 400V Cat. II, 400V Cat. II, 400V Cat.III 300V/ Cat.III 300V/ Cat.III 300V/ Cat. II, 400V Cat II 400V Cat II 300V Cat II 600V Cat II 600V Cat II 600V Warranty 24 months 24 months 24 months 24 months 24 months 24 months 24 months 24 months 24 months The OX530 & OX8040 are not listed in the RS Catalogue but are available. For details please contact the RS Quoteline Tel 01536 444101 Fax 01536 405020 RS shall not be under any liability for damage, loss, expense, loss of revenue or any consequential or indirect loss resulting from advice or information given in this manufacturer's leaflet. Please refer to the current RS Catalogue for prices and conditions of sale and servicing. RS Components Limited P.O. Box 99, Corby Northamptonshire NN17 9RS Tel 01536 201201 Fax 01536 201501 On-line ordering: http://rswww.com Your complete Calibration and Repair service ensures your oscilloscope meets your precise specification or calibration requirements. SPOINTCal complies with BS EN 30012-1:1994 NAMAS Cal incorporates BS EN 30012-1: 1994 plus the auditing of the quality of the physical measurements made. Tel 01536 405545 Fax 01536 401590 Chauvin Arnoux (UK) Ltd Waldeck House, Waldeck Road Maidenhead SL6 8BR Tel (01628) 788888 Fax (01628) 628099 and RS are registered trademarks of RS Components Limited an Electrocomponents Company

Analogue/Digital Analogue and Differential Oscilloscopes Metrix oscilloscopes are designed to meet all your signal measurement and analysis needs, for production, laboratory, R&D or professional training applications. Our Differential oscilloscopes means that you no longer require the use of an additional voltage probe. Our Combined oscilloscopes give you the advantage of digital and analogue systems, enabling you to display a signal in real time, in analogue mode, and view events prior to triggering.

Combined oscilloscopes provide the power of Digital technology plus Analogue mode OX 8100 OX 8050 OX 8040 Analogue plus digital processing The power of combined digital processing enables you to display and store events prior to triggering and therefore analyse the causes of a phenomena, over a wide range of scan speeds and input frequencies. With a Combined Metrix oscilloscope, you can display very slow phenomena (temperature variations, battery charges, very low frequencies,...). Finally, after acquisition, you can analyse and compare the recorded data (zoom, automatic measurements,...) A wide range of digital functions As well as their 5 cursors, the Combined oscilloscopes offer up to 17 automatic measurements. Their "GLITCH" mode, for capturing parasites, and "ENVELOPE" mode, for storing the minimum and maximum values of several successive acquisition operations, allow a large number of events to be displayed. Lastly, because RS 232 and Centronics links are standard features on most models, users can take advantage of the possibilities offered by digital techniques: analysis and processing on PC by the SX-METRO software, direct printout of the screen on a printer, etc. Combined Analogue/Digital Scopes Ordering Information Model Bandwidth RS Stock No Standard delivery includes FFT and harmonics analysis All digital models in the range include the FFT function, for studying the frequency breakdown of the signal, and harmonics analysis, both as standard features. In FFT mode, the cursor follows all the signal counts, each time indicating the amplitude (in Volts or db) and the frequency. In harmonics mode, the cursor automatically jumps from one harmonic to the next, indicating the number of the harmonic, its amplitude as a percentage of the fundamental and its frequency. This representation of the harmonics is richer than a conventional bar display. The FFT and harmonics analysis displays particularly distinctive because of the way the cursor moves and the nature of the information indicated on the screen Print quality equal to display quality The sampling concept quickly demonstrates its limits when the signal includes steep rises and falls. The solution currently used involves interpolating dots between them (METRIX EADJ dot-join function). Although this process has been around for some time, its extension to printing is much rarer. Unlike many oscilloscopes, the combined oscilloscopes offer the same quality of representation for display and printing (subject to the performance of your printer). Representation of rapid rises and falls on screen without the EADJ function. Same signal with the EADJ function. OX8050 50MHz 339-7212 +NAMAS Cal 343-2488 +SPoint Cal 343-2472 OX8100 100MHz 339-7228 +NAMAS Cal 343-2501 +SPoint Cal 343-2494 Printout of the same signal with the EADJ function.

A full choice of Analogue models from 30 to 100MHz OX 863 OX 803 OX 530 17 auto m a t i c m e a s u re m e n t s t r up time t f d own time F f re qu e n c y T p e ri o d W + p o s i t i ve pulse width W- n e ga t i ve pulse width Ve ff RMS vo l ta ge V m oy ave ra ge vo l ta ge Va mp a mp l i t u d e V b a s l ow vo l ta ge V h high vo l ta ge V p p peak to peak vo l ta ge V m a x max vo l ta ge D C + p o s i t i ve duty ra t i o D C - n e ga t i ve duty ra t i o ϕ phase shift Programming The Metrix combined oscilloscopes are fully programmable, in compliance with the SCPI (Standard Commands for Programmable Instruments) standard. They have RS232 interfaces for printing and remote control. You can thus take full use of all the analysis, documentation and presentation tools available under LabView* and LabWindows CVI*. These oscilloscopes have a standard digital automatic peripheral recognition link, with an RS232 or Centronics connection. You can thus send screen dumps directly to a printer. The SX-METRO software package enables you to control instruments, archiving, documentation and result processing. *LabWindows CVI and Labview are registered trademarks of National Instruments. Advantages of analogue mode Analogue processing enables signals to be displayed in real time, without delay resulting from analogue/digital conversion and storage. The entire signal is represented, rather than a series of points, without any danger of misinterpretation. In addition, in analogue mode, virtually all trigger elements are represented. Finally, the Autoset and delayed trigger functions enable signals to be synchronised without difficulty. Ease of Use All Metrix oscilloscopes have the same appearance and handling as Analogue oscilloscopes, no specific training is necessary. In addition, they have an AUTOSET function, which enables you to automatically obtain a correct representation of the signal, with readout of parameters on the screen. The AUTOSETfunction provides a correct representation of the signal, simply and automatically. Screen display of parameters and cursors The OX 863 oscilloscope has a Readout function, for displaying: vertical and horizontal offset coefficients, the triggering point and its slope, the TV standard or line, the probe coefficient or the measuring cursors. Counting of video lines Each model has a TV trigger mode, enabling all the lines of a video picture to be displayed. The OX 863 also has a video line counting mode. This trigger mode is used to display a specific line, chosen by the user from the TV norm (252-625 lines) or a specific norm ( up to 1255 lines). This line can be analysed via the second time base. Analogue Scopes Ordering Information Model Bandwidth RS Stock No OX803 40MHz 262-8852 +NAMAS Cal 262-9653 +SPoint Cal 262-9669 OX863 100MHz 262-8868 +NAMAS Cal 262-9940 +SPoint Cal 262-9956

Differential input oscilloscopes offer a single, global solution OX 8062 OX 8042 OX 822 The only genuine protection against dangerous voltages In today's world, nobody can ignore safety any more. But are you always sure that the voltage measured is earthed? Do you always have a single reference potential for the 2 channels? If you look objectively at the various cases of measurement on site, whether in electronics or the electrotechnical field, you will see that it is often necessary to set up a costly and complex assembly. With METRIX's differential-input oscilloscopes there is no need to use accessories to observe the signals superimposed on the mains signal or to analyse the command voltage and the output from any circuit at the same time, with a common mode voltage of up to 600V. With a conventional oscilloscope In differential mode, one BNC connector corresponds to the + terminal and another to the - terminal. In conventional mode: CH1- and CH2- are inhibited Only METRIX oscilloscopes are suitable for such a wide range of uses. IEC 61010, Cat.III, 300 V Cat.II, 600 V, what could be better? The OX 8062, OX 8042 and OX 822 oscilloscopes can be used in the laboratory or on site, even in difficult industrial environments, as shown by their installation category... Change the mode as you want With no danger, it is possible to switch from one operating mode to the other at any time simply by pressing a button. This flexibility will be particularly appreciated for electronic applications that use miniature probes. Up to 200V/div. without accessories Whether the signal amplitude is high or low, the OX 8062, OX 8042 and OX 822 offer a sufficiently wide dynamic range (from 10 mv/div. to 200 V/div.) for measurement without probes. More savings and more flexible use! With a differential oscilloscope Example of use of a differential oscilloscope Each channel operates independently in differential or conventional mode. All you have to do to choose the mode is press a key. Differential Input Scopes Ordering Information Model Bandwidth RS Stock No Combined Analogue/Digital OX8042 40MHz 339-6461 +NAMAS Cal 343-2545 +SPoint Cal 343-2539 OX8062 60MHz 339-6449 +NAMAS Cal 343-2523 +SPoint Cal 343-2517 Analogue only OX822 20MHz 339-6477 +NAMAS Cal 343-2573 +SPoint Cal 343-2551