Instructions. P MHz 1X/10X Passive Probe

Similar documents
KHT 1000C HV-Probe Calibrator. Instruction Manual

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC connection. 500 MHz system bandwidth. Double HF adjustment

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC Connection. 500 MHz System Bandwidth. Double HF Adjustment

Keysight 16048G/H Test Leads

MiniModules. Reference Manual. Series D VA 3120 Dual Analog Video Distribution Amplifier

TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

User Manual. TDS3SDI 601 Digital Video Application Module

User Guide. HDMI Fiber Optic Extender. DVI-7350a

MiniModules. Reference Manual. Series D VD 3620 Dual HD / SD Digital Video Distribution Amplifier

Supplement. TDS1000 and TDS2000 Series User Manual Specifications Update

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

1205 RF Probe 20 db. User s Guide. Version 1.10

D10C2 10-bit Serial Digital to Composite/ Component Converter User Manual

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

D5CE Serial Digital Encoder

MiniModules. Reference Manual. Series C DA 3000 SDI to Analog Video Converter

Tablet Oscilloscope Quick Guide

User Guide. HDMI Active Cable Extender. DVI-7370c

RD10MD Dual HD to SD Down Converter R-series Card Module

TVAC20000 User manual

yellobrik Reference Manual P MV G/HD/SD Quad Split Multiviewer Revision 1.1 March 2016 Broadcast Television Equipment

R&S RT-Zxx High-Voltage and Current Probes Specifications

TDS Family Option 05 Video Trigger Interface

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

CardModule. Reference Manual. Series P VD 5005 G Video Media Processor (Frame Synch with Audio Processing for embedded Audio) Version 1.

Bench Test Instruments and Handheld Oscilloscopes Basic Service

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

Reference Manual D VD 5820

1X4 HDMI Splitter with 3D Support

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

MiniModules. Reference Manual. Series C AD Bit CVBS / YC to SDI Converter. Ver 1.1 Ver

Instruction Manual 1T-CT-630 Series HDMI to CAT.6 Extender System

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

R&S RT-Zxx Standard Probes Specifications

P VD 5000 G Video Media Processor (Frame Synchronizer) P VD 5000 G. REF loop. REF in. SDI in 2. SDI in 1. SDI 2 loop. SDI 1 loop. SDI out 2.

NS-3 RF Noise Source Operation Manual

Reference Manual D VA 5718 L D VA 5724

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Metal Electrode Meter

User Manual. Model 979T and 979R Digital Audio Converters


DVI-D Fiber Optic Cable

DisplayPort Extender over 2 LC Fibers

32 Channel CPCI Board User Manual

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

PRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)

DisplayPort Extender over 2 LC Fibers

User Manual. Model 1351 DVI Repeater with HDCP

HD VIDEO IP STREAMER CT-HDVD-HDSTR-KIT

DA8-T DA8-T MANUAL

Quick Start. SHS1000 Series Handheld Digital Oscilloscope QS03010-E02B 2015 SIGLENT TECHNOLOGIES CO., LTD

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

SPG600 & SPG300 Sync Pulse Generators

APSPB PUSH BUTTON ZERO Installation Manual

User Manual. A6906S Fiber-Optic Isolation System

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

WVR500 Waveform/Vector Monitor

User Manual. CSA8000 Communications Signal Analyzer TDS8000 Digital Sampling Oscilloscope

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

HDMI Extender over UTP Cable

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

A3U5 Replacement 1705A Spectrum Monitor

MiniModules. Reference Manual. Series P MX 3312/3313 D Dual Analog Audio Multiplexer. LYNX Technik AG

OWNER'S MANUAL MYCRO SUB

User Instructions. 16 SCB Sync Station.

USB-TG124A Tracking Generator User Manual

INSTRUCTION MANUAL PULSUS PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

True RMS AC/DC Mini Clamp Meter

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

HDMI Extender Transmission more than 3800M

OPERATION AND MAINTENANCE MANUAL

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

Model P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Kramer Electronics, Ltd. USER MANUAL. Model: VM-3A. Audio Distributor

SC-C1M SiriusConnect TM Vehicle Tuner

PSC UHF Log Periodic Antenna

Composite Video Extender

VGA Extender LR EXT-VGA-141LR. User s Manual

Kramer Electronics, Ltd.

Utility Amplifier GA6A Model

VGA Extender LR EXT-VGA-141LR. User s Manual

DSG1 Lite User Manual

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

User Manual CTS 850 Test Set SDH/PDH, Jitter & Wander

EZ-LIGHT K30L Series With Independent Push Button Contact

Operating Instructions

PicoScope 2000 Series PC Oscilloscopes

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Transcription:

Instructions P2100 100 MHz 1X/10X Passive Probe 071-0774-01 071077401

Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

WARRANTY Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product. THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Contacting Tektronix Product support Service support Toll free Number Postal Address Web site For questions about using Tektronix measurement products, call toll free in North America: 1-800-833-9200 6:00 a.m. 5:00 p.m. Pacific time Or contact us by e-mail: tm_app_supp@tek.com For product support outside of North America, contact your local Tektronix distributor or sales office. Tektronix offers a range of services, including Extended Warranty Repair and Calibration services. Contact your local Tektronix distributor or sales office for details. For a listing of worldwide service centers, visit our web site. In North America: 1-800-833-9200 An operator can direct your call. Tektronix, Inc. Department or name (if known) P.O. Box 500 Beaverton, OR 97077 USA www.tektronix.com

General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Personal Injury Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source. Connect and Disconnect Properly. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument. Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. Connect the ground lead of the probe to earth ground only. Do Not Operate Without Covers. Do not operate this product with covers or panels removed. Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. P2100 Probe Instructions i

General Safety Summary Safety Terms and Symbols Terms in This Manual. These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. Symbols on the Product. These symbols may appear on the product: CAUTION Refer to Manual Double Insulated Protective Ground (Earth) Terminal ii P2100 Probe Instructions

P2100 Passive Probe The P2100 is a compact, 1.5 meter passive probe with selectable 1X/10X attenuation. The probe is designed for use with general purpose oscilloscopes with input capacitance between 18 and 35 pf. There are no user-serviceable parts in the P2100 probe. Features and Accessories Table 3 shows the features and accessories of the P2100 probe. Table 3: Features and standard accessories Feature/Accessory 1X 10 X Description Probe attenuation. This switch selects the attenuation factor of the probe. Hook tip Color marker bands Hook tip. Connects the probe tip to wires and component leads for hands-free measurement. NOTE. For a solid connection, firmly push and twist the hook tip onto the probe tip before using. Replacement part number: 013-0318-00 Color marker bands. Attach matching pairs of the color marker bands onto the strain-relief sections of cable at the probe head and compensation box. When several probes are connected to an instrument, the color marker bands enable quick verification of which probe is connected to which instrument channel. Replacement part number: 016-0633-00 Ground lead. Use the ground lead for connecting the probe ground to the circuit. Replacement part number: 196-3466-00 P2100 Probe Instructions 1

P2100 Passive Probe Table 3: Features and standard accessories (Cont.) Feature/Accessory Description Adjustment tool. Used to adjust probe compensation. Access the adjustment through the opening near the BNC connector. ÎÎÎ ÎÎÎ Replacement part number: 003-1873-00 Instructions. Provides instructions for operating the probe. Replacement part number: 071-0774-01 Guard. Keeps fingers away from the probe tip for protection against electric shock. Finger guard WARNING. To avoid electric shock when using the probe, keep fingers behind the guard on the probe body. 2 P2100 Probe Instructions

P2100 Passive Probe Probe Compensation Due to variations in oscilloscope input characteristics, probe low-frequency compensation may need adjustment after moving the probe from one oscilloscope to another. If a 1 khz calibrated square wave displayed at 1 ms/division shows significant differences between the leading and trailing edges, perform the following steps to optimize low-frequency compensation. 2. Connect the probe to the calibration signal on the oscilloscope front panel. 3. Press AUTOSET or otherwise adjust your digitizing oscilloscope to display a meaningful waveform. 4. Adjust the trimmer in the probe until you see a perfectly flat-top square wave on the display. See Figure 4. Undercompensated Overcompensated Properly compensated Figure 4: Probe compensation waveforms P2100 Probe Instructions 3

P2100 Passive Probe Specifications Table 4: Electrical characteristics 10X position 1X position Bandwidth DC to 100 MHz DC to 7 MHz Attenuation ratio 10:1 1:1 Compensation Range 18 pf-35 pf All oscilloscopes with 1M input Input resistance 10 M ± 2% 1M ± 2% Input capacitance 14.5 pf-17.5 pf 80 pf-110 pf Maximum input voltage 1 10X position 300 V RMS CAT I or 300 V DC CAT I 300 V RMS CAT II or 300 V DC CAT II 100 V RMS CAT III or 100 V DC CAT III 420 V peak, <50% DF, <1 sec PW 670 V peak, <20% DF, <1 sec PW 1X position 150 V RMS CAT I or 150 V DC CAT I 150 V RMS CAT II or 150 V DC CAT II 100 V RMS CAT III or 100 V DC CAT III 210 V peak, <50% DF, <1 sec PW 330 V peak, <20% DF, <1 sec PW 1 As defined in EN61010-1. See Certifications and compliances in Table 5. Voltage (RMS) 10X 1X Frequency (Hz) Figure 5: Derating curve for determining maximum input voltage 4 P2100 Probe Instructions

P2100 Passive Probe Table 5: Certifications and compliances EC Declaration of Conformity Overvoltage Ct Category Pollution Degree 2 Safety Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities: Low Voltage Directive 73/23/EEC as amended by 93/68/EEC: EN 61010-1/A2 Safety requirements for electrical equipment for measurement, control, and laboratory use EN61010-2-031: 1994 Category: CAT III CAT II CAT I Particular requirements for hand-held probe assemblies for electrical measurement and test Examples of Products in this Category: Distribution-level mains, fixed installation Local-level mains, appliances, portable equipment Signal levels in special equipment or parts of equipment, telecommunications, electronics Do not operate in environments where conductive pollutants may be present. UL3111-1, First Edition & IEC61010-2-031, First Edition CSA C22.2 No. 1010.1-92 & CAN/CSA C22.2 No. 1010.2.031-94 EN61010-1/A2 EN61010-2-031 Pollution Degree 2 P2100 Probe Instructions 5

P2100 Passive Probe Table 6: Environmental characteristics Temperature Operating 0 C to +50 C Nonoperating 20 C to +60 C Cooling Method Convection Humidity +40 C or below 90% relative humidity +41 C to +50 C 60% relative humidity Altitude Operating 3,000 m Nonoperating 15,000 m 6 P2100 Probe Instructions