Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information Type Part no. SGS-S08PPSW0 90 Other models and accessories www.sick.com/slg Sender/receiver inimum detectable object (DO) Cross beam, 5 mm Beam separation 0 mm Optical light exit Slim Number of beams 8 Detection height,080 mm Configuration Without teach button with configuration software Cross beam/parallel beam Cross beam Output Output, if light beam interrupted Automatic teach Automatic teach Alignment aid Without alignment aid uting function uting function deactivated Performance aximum range m ) inimum range Cross beam: 0. mm ) Operating range m Response time Cross beam, 57 ms ) No reserve for environmental issue and deterioration of the diode. ) Aperture ± 0. Interfaces Switching output x PNP Inputs Teach-in input Connection type Cable with 8 male connector, -pin AUTOATI LIGHT GRIDS SICK Online data sheet 08-05-0 :5:8 Subject to change without notice
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS echanics/electronics Light source Wave length Infrared light 950 nm Supply voltage V s DC V, ± 0 % Power consumption sender 80 ma ) Power consumption receiver Output current I max. Output load capacitive Output load inductive Initialization time Dimensions (W x H x D) Housing material Indication Synchronization 70 ma 00 ma 00 nf H s 5 mm x,5. mm x 8 mm PA LED Optical Enclosure rating IP65 ) Circuit protection Weight Pulse frequency Aluminum stabilizer U V connections, reverse polarity protected, Output short-circuit protected, Interference pulse suppression 0 g 500 Hz With stabilizer ), without load. ) Operating in outdoor condition only with a external protection housing. Ambient data Protection class III EC EN 6097-5- Ambient operating temperature 5 C +55 C Ambient storage temperature 5 C +70 C Ambient light immunity Direct: 00,000 lx ) Indirect: 50,000 lx Vibration resistance 5 g, 0 Hz... 55 Hz (IEC 68--6) Shock load 0 g / DIN EN 60068--9 / 6 ms ) Sunlight. Classifications ECl@ss 5.0 77090 ECl@ss 5.. 77090 ECl@ss 6.0 77090 ECl@ss 6. 77090 ECl@ss 7.0 77090 ECl@ss 8.0 77090 ECl@ss 8. 77090 ECl@ss 9.0 77090 08-05-0 :5:8 Online data sheet Subject to change without notice AUTOATI LIGHT GRIDS SICK
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T ETI 5.0 ETI 6.0 EC0059 EC0059 UNSPSC 6.090 958 Dimensional drawing (Dimensions in mm (inch)) Sxx-Sxxxxxxxxxx Slim, with stabilizer L = DH + R + 5.5 (.0) 7 8 7 6.5 (.) 6. (0.5) 6 Receiver Sender Sender 5 (0.59) 5.8 (.80) 8.5 (0.7) First beam Last beam Beam separation (R) Number of beams (n) 5 Detection height (DH) 6 Connection 7 Same distance 8 See table (hole spacing stabilizer) 0 (0.9) 99 (.90) R DH = (n x R) R 5 Ø.8 (0.5). (0.06) x 5. (0.9) 00 60 60 080 0 0 00 0 0 0600 0 60 AUTOATI LIGHT GRIDS SICK Online data sheet 08-05-0 :5:8 Subject to change without notice
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS 0760 0 60 090 0 960 080 0 960 0 5 0 80 00 5 0 80 Adjustments SAS, SGS, receiver, LED indication / TEACH constantly shining out Supply voltage Active if teach-in button is pressed No object in the light path Connection type and diagram SGS Sender L+ Test NC Receiver PNP/NPN L+ Teach Receiver x PNP/ x NPN L+ 08-05-0 :5:8 Online data sheet Subject to change without notice AUTOATI LIGHT GRIDS SICK 5
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Concept of operation SAS, SGS, SPL Optical synchronization The light grid communicates via the light beams. A cable is not necessary for the optical synchronization. Configuration mode If the teach button is pressed longer than 5 s, you switch into the configuration mode. In the configuration mode the menu items are indicated by the green LEDs. If the teach button is then pressed for < s, the respective function is activated or reset (yellow LED on or off). If the teach button is pressed for s to 5 s long, you switch to the next menu item. To exit the configuration mode, press the teach button for > 5 s or wait for 0 s.. Light grid in RUN mode, green LED illuminates, yellow LED illuminates. Press teach button > 5 s. The light grid switches into the configuration mode menu item cross beam/parallel beam. The first green LED from top flashes. The other menu items in sequence of the menu setting of the light grid Alignment aid ) > 5 s Invert switching output. Cross or parallel beam set up. ) < s = Yellow LED on, Crossed beam. = Yellow LED off, Parallel beam. Press teach button < s to switch between the settings. Auto-teach ) AUTO TEACH AUTO TEACH. Go to the next menu item. Press teach button for s to 5 s to switch to the next menu item (in this case alignment aid ). Pushbutton lock Standard values ) Invert second switching output. Exit the configuration mode. s... 5 s > 5 s oder > 0 s = Press teach button > 5 s, save parameters. = Wait > 0 s, parameters not saved. ) Configure the light grid in a -way cross-beam or a parallel-oriented operating principle. The cross beam can be used to improve the resolution in the middle detection area. Objects up to a size of 5 mm can be detected. The response time increases. uting 5) ) The alignment aid is recommended for applications with high ranges. The signal strength of the receiver is permanently displayed by four green alignment LEDs. Depending on the strength, the number of illuminated LEDs differ. When reception is strong, all four LEDs illuminate. The alignment aid must be deactivated again after alignment. ) After commissioning (power on), the switching threshold is taught in automatically. No object should be between the sender and receiver during this process. ) With standard values all parameters are reset to the delivery state. 5) If a beam is interrupted permanently, it disappears after > 60 s, and the switching output is enabled again. If a second switching output is present, it remains. UTING UTING 6 AUTOATI LIGHT GRIDS SICK Online data sheet 08-05-0 :5:8 Subject to change without notice
SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS Setting the switching threshold. Light grid in RUN mode, green LED illuminates, yellow LED illuminates.. Alignment aid is automatically activated for 0 s.. Light grid in RUN mode, green LED illuminates, yellow LED illuminates. s... 5 s Press the teach button for s to 5 s. During the teach process the green LEDs illuminates sequentially. The red LED illuminates. = Optimum light reception. = Light reception not optimized, align sensors. = No light received, check light path. The light grid switches after 0 s automatically back into the RUN mode. The switching threshold is set. Funktionsprinzip Slim & Flat Slim model = light emission on narrow side Flat model = light emission on broad side Recommended accessories Other models and accessories www.sick.com/slg Brief description Type Part no. ounting brackets and plates ounting bracket for light grids up to a monitoring height of 600 mm, mounting on the face sides, x BEF-SLG, x BEF-SLG BEF-SLG-SET 0557 Plug connectors and cables Head A: female connector, 8, -pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, m YF8U-00VAXLEAX 095888 08-05-0 :5:8 Online data sheet Subject to change without notice AUTOATI LIGHT GRIDS SICK 7
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations www.sick.com SICK AG Waldkirch Germany www.sick.com