Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

Similar documents
The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

PHI 5000 VersaProbe TM Operator s Guide

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Figure 1. MFP-3D software tray

2.1. Log on to the TUMI system (you cannot proceed further until this is done).

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

CHEMISTRY SEMESTER ONE

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Operation Procedure for Phillips XL30 ESEM

Processing data with Mestrelab Mnova

FEI Strata Dual-beam FIB

1. Check the accelerating voltage, must be at 200 kv (right screen), HT (µa) (left panel) at and Emission (left panel) at

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

Quick Start Bruker Dimension Icon AFM

MestReNova Manual for Chem 201/202. October, 2015.

CHA EVAPORATOR Short Reference User guidelines

Dektak Step by Step Instructions:

Standard Operating Procedure of nanoir2-s

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

University of Minnesota Nano Fabrication Center Standard Operating Procedure

JEM 2100 Manual. Operation and Basic Alignment Instructions. Check the vacuum levels (power supply closet) Column (blue scale): < 2.

TT AFM LongBeach Procedures and Protocols V2.1

CHA EVAPORATOR. User guidelines. p.1. by Carlos Manzanedo. Last revised: 10/05/2000

CHECKLIST FOR VERIOS OPERATION 1. GENERAL The SEM lab is used assuming "operating room" cleanliness, i.e., the SEM lab is a high visibility lab and

Quick Start ATOMIC FORCE MICROSCOPE West Campus Imaging Core

FEI FIB Focused Ion Beam

JEM 3010 Manual (2011 Edition)

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

University of Minnesota Minnesota Nano Center Standard Operating Procedure

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

FIB Operating Procedure. Effective Date: 08/14/2012 Author(s): Jiong Hua Phone:

FACSAria I Standard Operation Protocol Basic Operation

PulseCounter Neutron & Gamma Spectrometry Software Manual

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

System Requirements SA0314 Spectrum analyzer:

University of Minnesota College of Science and Engineering Characterization Facility Ganesha SAXSLAB User manual

F7000NV ROBOT VISION OPERATING MANUAL

Dektak II SOP Revision 1 05/30/12 Page 1 of 5. NRF Dektak II SOP

Approved by: / / R. Battaglia 12/16/2016

DektakXT Profilometer. Standard Operating Procedure

Activity P27: Speed of Sound in Air (Sound Sensor)

Linkage 3.6. User s Guide

MTL Software. Overview

IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface)

Software manual. ChipScan-Scanner 3.0

WJ-HD616K/716K Quick Reference Guide

PINMRF. Checkout Quiz - Varian Inova-300 Version

HRXRD Analysis of Epitaxial Thin Films

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics

CytoFLEX Flow Cytometer Quick Start Guide

Footnotes and Endnotes

imso-104 Manual Revised August 5, 2011

Manual for TV software. TT-Viewer version Figure: TT-budget S2-3200

MicroMax 384. Operation Manual Rev Fax: (33) 1/ U.K.: 020/

E X P E R I M E N T 1

Amazon Account 3/14 TM 1

EDL8 Race Dash Manual Engine Management Systems

VIDEO JUDGE SYSTEM SETUP & CAPTURE

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions

Preparing for remote data collection at NE-CAT

Lab experience 1: Introduction to LabView

Precautions and Disclaimers What You Can Do with Geometry Manager Pro Check Your Computer System requirements...

More Skills 14 Watch TV in Windows Media Center

K Service Source. Apple High-Res Monochrome Monitor

Motion Amplification

EndNote Online. Getting Started Guide (Windows)

STANDARD OPERATING PROCEDURE:

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

TOMELLERI ENGINEERING MEASURING SYSTEMS. TUBO Version 7.2 Software Manual rev.0

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Part names (continued) Remote control

Camtasia for Mac. Create Your First Video Guide. Release 1.1. February TechSmith Corporation. All rights reserved.

Contacts: English Department Office 238 Moreland Media Services 109 Kidder

PogoStick and Research Pogo App Operator s Guide

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

U S E R G U I D E HD1000

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

A-ATF (1) PictureGear Pocket. Operating Instructions Version 2.0

Reflecta Super 8 Scanner. User Manual

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

About your Kobo ereader...6

Mini Micro Pulse Lidar System

Practicum 3, Fall 2010

Approved by Principal Investigator Date: Approved by Super User: Date:

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

December 2006 Edition /A. Getting Started Guide for the VSX Series Version 8.6 for SCCP

Florida State University Thayumanasamy Somasundaram

Liquid Chromatography- Mass Spectrometer Manual

***Please be aware that there are some issues of compatibility between all current versions of EndNote and macos Sierra (version 10.12).

HV/PHA Adjustment (PB) Part

Store Inventory Instruction Guide

K Service Source. Apple High-Res Monochrome Monitor

SEM- EDS Instruction Manual

A6 OPERATING INSTRUCTIONS

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Transcription:

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions Note: Enter your complete name, CMRF user code, and date into the record book. You must have previously filled out a project information sheet. Note: Vision Manager and Instrument Manual Control control the instrument, Vision Processing is used for converting data files. 1. About XPS: -XPS measures the top 10 nm of samples. You only need 110 um for sample (tiny piece). -Samples can be set up the night before with vacuum if you want to use XPS in the morning (wouldn t be charged for vacuum overnight). -A survey scan scans all elements and only takes 2-3 minutes. -For trace elements, a core level scan can have 2000 ms dwell time for a high resolution (publication quality) or 1000 ms for non-publication data. One element takes 10 to 20 minutes to scan. 2. Sample prep: -With gloves on, scrape samples off with a razor blade and clean the holder with isopropanol. -With clean tweezers, load samples onto the sample holder samples may be loaded directly onto carbon tape, cemented on with carbon/silver paint or on metal (Si, In, etc.) mounted on the tape. (Samples go on top of sample holder, which is a thinner metal strip than the bottom. The end with 2 posts between the top and bottom will go into the XPS first). Keep samples toward the center of the sample holder. -Press samples onto the mounting medium with a clean spatula. Tip the sample holder to the side and tap the side of the sample holder with mounted sample(s) on clean surface to remove all loose sample material. 3. Loading the sample(s) and setting up vacuum: Note: If the Instrument Manual Control window is not open, then in Vision Manager go to Window and select Manual Window. Note: If Vision Manager is not open, then consult the restarting instructions or contact a staff member. -Ensure that the STC-SAC valve is closed (Red). -Loosen (by partially unscrewing) the knobs on the door (by the sample exchange probe). -Vent the STC (in Vacuum in Instrument Manual Control). -Turn on the flow of N 2 Gas on the bottle and flow valve (on the pipe). -Hold the probe (support the weight) and completely unscrew knobs. -When the door seal opens a little (enough to open the door) turn off the N 2 Gas at both the bottle and the flow valve. Note: The door seal gasket will probably fall out Do not let it fall on the ground Catch the gasket when you open the door. Page1

-Open the door all the way and turn the probe knob clockwise until the claw end of the sample exchange rod is visible. -Put the sample holder on the claw. -Turn the probe knob counterclockwise until the light at the end of the probe with the cord is green. -Reseat the door seal gasket. Be sure it does not come out when trying to close the door if the seal gets pinched in the door, the STC will not pump down -Close the door and screw the door knobs back in (Do not overtighten). -In Instrument Manual Control, go to vacuum and pump STC. -Support the probe until the vacuum has sealed the sample exchange port. Note: The STC on the Vacuum schematic will go from pink to blue to cyan to orange - orange is good and indicates the pump is working. If this does not happen, lift the probe to support it and retighten the screws. Do not leave until you are sure the pump is working. When the STC turns yellow, you will start to see vacuum values. Note: In the meantime, in X-ray (In Instrument Manual Control) click standby to warm up the source so that this is completed during vacuuming. This vacuum step takes 40 minutes to 1 hour or longer depending on the type and number of samples and the amount of sample outgassing. You want to see 5x10e-7 or better in the STC. (in the meantime, follow part 4 for setting up data collection). 4. Setting up data collection: Note: Data may be collected point by point manually in instrument manual control or by setting up a flowchart of points in Vision Manger. Following are the instructions for using Vision Manager for analysis. -Make a folder with the user name in the data folder on the desktop. Note: In Vision Manger, there are three function buttons near the top of the Vision Manager window that will be used to set up a flowchart: Dataset, Acquisition and State Change. A typical run starts with a Dataset, followed by one or more Acquisitions and ending with a State Change or a change to a new sample position. See below: - Dataset is the file where subsequent scans are saved. A new Dataset must begin every series of analysis or all of the scans will be saved to one file. - Acquisition is where the user can set up a scan of energies. A full energy range scan is called a Survey scan. A scan focused on a specific element orbital energy is called a Region or Core Level scan. - State Change is where the user can change analysis type or conditions, such as sample position. Note: In Vision Manager, a flowchart from a previous run can be loaded and modified for current acquisition or a new flowchart can be created. To load a flowchart from a previous run, select File, Load Run and navigate to a previous run. To create a new flowchart, follow the instructions which follow. Note: In Vision Manager, type file names without spaces and names that are fewer than 30 characters in length. If you need a space, use an underscore ( ). Page2

Note: In Vision Manager, the first Dataset and Acquisition do not need a starting sample position in the flow chart (you will move to the first sample position manually in Manual Control before starting the run). -Select the Dataset button in the top center of the screen. Type a name for the dataset in the Name field. In the Filename field, browse to and select your folder in the data folder. In the Selection box, type the name for the dataset at the end of the filename (eg. /C=/data/yourfoldername/datasetname). To add the Dataset to the flowchart, move the mouse cursor to the flowchart section of Vision Manager in the upper left and click with the mouse scroll wheel. -Select the Acquisition button in the top center of the screen. For a Survey or wide energy range scan: -Name the acquisition Survey or another name to indicate a wide energy range scan. Note: Be sure to press enter after any manual typed changes. If you see a vertical black bar next to a field that has been manually altered, then you need to press enter to save the changes. In Standby Control : -Under Action on Completion select Leave On. If this acquisition is the final acquisition in the flow chart, then refer to the instructions below for the last sample. -In Analyser : -Under Mode select Spectrum. -Under Lens select Hybrid. -Under Resolution select Pass energy 160. -Choose the Slot for the aperture. In Excitation : -Select Xray Gun. -Under Source select Mono (Al). -Under Emission (ma) enter 10 ma. -Under Anode HT (kv) enter 15 kv. In Neutraliser : -Choose On for Acquisition for non-metal samples, or choose Under Manual Control for metal samples. In Scan Control : -Under Technique select XPS. -Under Type select Spectrum. -Choose B.E. for binding energy. -Under Ref. (reference) select Al (Mono). -Select the box for the Energy Regions Table. In the table: -Under Region Name, type survey and press enter to populate the table. -Set the Start ev to 1200 ev. If Centre ev is displayed, right click on Centre ev and select Start ev to change. -Set End ev to -5 ev. -Set Step ev to 1 ev. -Set Dwell ms to 200 ms. -Set # Sweeps to 2 sweeps. Page3

To add the Aquisition to the flowchart, move the mouse cursor to the upper left, flowchart section of Vision Manager and click with the mouse scroll wheel. For a Region, Core Level, or narrow energy range scan: -Name the acquisition Region or another name to indicate the narrow energy range scan. In Standby Control : -Under Action on Completion select Leave On. If this acquisition is the final acquisition in the flow chart, then refer to the instructions below for the last sample. -In Analyser : -Under Mode select Spectrum. -Under Lens select Hybrid. -Under Resolution select Pass energy 20. -Choose the Slot for the aperture. In Excitation : -Select Xray Gun. -Under Source select Mono (Al). -Under Emission (ma) enter 10 ma. -Under Anode HT (kv) enter 15 kv. In Neutraliser : -Choose On for Acquisition. In Scan Control : -Under Technique select XPS. -Under Type select Spectrum. -Choose B.E. for binding energy. -Under Ref. (reference) select Al (Mono). -Select the box for the Energy Regions Table. In the table: -Below the table select Clear All Rows. - Under Region Name, type a region of interest (e.g. C 1s, O 1s, Cl 2p, etc.) and press enter to populate the table. Note: The neutralizer will shift the binding energy peak to a lower value, so manually subtract 2 ev from all end ev values. If Centre ev is displayed, right click on Centre ev and select Start ev to change. -Set Dwell ms to 1000 ms. -Set # Sweeps to 1 sweeps. To add the Aquisition to the flowchart, move the mouse cursor to the upper left, flowchart section of Vision Manager and click with the mouse scroll wheel. -Select the State Change in the top center of the screen. -Select Position Change from the button options under the State Change button. Enter a name for the position (usually a sample name) and press enter. To add the Position Change to the flowchart, move the mouse cursor to the upper left, flowchart section of Vision Manager and click with the mouse scroll wheel. An actual sample position will be added to the sample position table later. Note: The first position change will be to the location of your second analysis point, as you start analysis already positioned on your first sample. Page4

Additional Datasets, Acquisitions, and Position Changes can be added to the flow chart for each additional sample. You can manually create Datasets, Acquisitions, and Position Changes following the above instructions. Alternatively, you may select one in the flowchart, edit it in the central window section of Vision Manager for your next sample and then paste it into the flowchart. For the last sample in the flowchart, in the last Acquisition and in Standby Control, under Action on Completion select go to standby. In Vision Manager: -Select File and Save the Run. In the Filename field, browse to and select your folder in the data folder. In the Selection box, type the name for the dataset followed by flowchart at the end of the filename (eg. /C=/data/yourfoldername/datasetname/flowchart). This saves the flowchart schedule so that it can be loaded again and modified for additional analysis. 5. Transferring the Samples for Analysis -In Instrument Manual Control, scroll to the Stage window. -At the bottom of the Positions table select Clear all Rows. -Select Load Table and select Load.dset under Files and click Ok (this will load the preset load position of the analysis claw in the SAC) -Click on the load position xyz coordinates line in the table to highlight the row and click Go To above the table to drive the SAC analysis claw into the load position. -When pressure is less than 5e-7 torr (ideally) in the STC, open the STC-SAC valve. Be sure the light on the end of the transfer probe is green. -Turn on the light source (KL1500) -Insert the sample into the SAC by rotating the knob on the sample exchange probe clockwise. Watch the sample holder through the port and make sure it loads onto the sample analysis claw. -Take the sample exchange probe hook off the sample holder by moving it left (moving it towards you. To go faster, while holding left, also press right ) using the remote control (the Autostage Manual Controller) or the stage controls in Manual Control. -Turn the sample exchange probe knob to take the probe out. -Close the STC-SAC valve in Vacuum in Instrument Manual Control. 6. Setting up sample positions: -Turn on the TV monitor. The small x on the screen is the location of analysis. -Adjust the camera field of view to the widest field of view to locate the samples. Adjust the camera using the adjustment ring in the slot near where the camera is attached to the SAC. -Move the sample holder using the remote control until the first sample is centered. -Decrease the camera field of view to the smallest field of view. -Adjust the X, Y, and Z position of the sample to get the sample in focus. The sample should be in focus from the NW corner, through the center, to the SE corner of the image. The NE and SW corners should be slightly out of focus. Note: The camera image (on the TV) is also viewable through the software. In Vision Manager, at the top, select Window and select Real Time Display from the dropdown options. Move the Real Time Display window to the right computer monitor and maximize it (make it use the whole Page5

screen). In Instrument Manual control, turn on (click the button at the top of the screen) and scroll to the Optical Image section. Select View and the image should appear in the Real Time Display window in the lower left. Note: The stage can be moved using the X, Y, and Z controls in the Stage section in Instrument Manual Control, instead of using the remote control. -In Instrument Manual Control, scroll to the Analyzer section. -In Analyser : -Under Mode select Spectrum. -Under Lens select Hybrid. -Under Resolution select Pass energy 160. -Choose the Slot for the aperture. -Scroll to the Acquisition section. -Under Type select Snap Shot. -Below the Energy Regions Table, select Clear all Rows. -Enter an element present in your sample that you want to analyze, e.g. C 1s (click enter to populate the table, be sure there is a space between C and 1). Check with the binding energy tables on the wall to make sure the window is centered on the peak. -In Vision Manager, at the top, select Window and select Real Time Display from the dropdown options. Move the Real Time Display window to the right computer monitor and maximize it (make it use the whole screen). Right click on the window in the middle of the left side of the Real Time Display window, and select Trace Counts (cts/sec). -In Instrument Manual Control: -Scroll to the Neutraliser section. -Turn the neutraliser On. -Scroll to the X-ray Gun section. -Turn on the X-ray source (should hear a click and water - if you don t hear these, go to standby and try to turn back on). If there is trouble turning the X-ray source on, use set the filament to 6 ma and anode to 10 kv; after it is stable, change the values to the normal 10 ma and 15 kv, respectively -Scroll to the Acquisition section. -Turn on the acquisition. After a few seconds, snapshot acquisition should appear in the Real Time Display window. Note: If a scan does not start to appear in the Real Time Display window after 1 minute, you may need to activate the real time display by selecting the Acquiring button in the left center of the Vision Manager window. If acquisition stays off after activating the RTD window, you can click Restart in the Acquisition section of Instrument Manual Control which will reset the acquisition. If you see x s in the element table, delete that row and start again, as rows with x s cannot be edited. -Move the sample (X, Y, and Z) to maximize the signal intensity (watch the numbers in the NW corner of the spectra display and the values in the count trace in the Real Time Display ). If the sample is well focused, counts can reach 200k or 300k. In Snapshot mode, look for 1k to 2k counts per second (cps). Page6

-When the signal is maximized: -Turn off Acquisition. -Set the X-ray source to Standby. -Turn off the Neutraliser. -In the Stage section: -Below the sample Positions table, select Clear All Rows. -Select the row for the sample position (Click on the row so that it is highlighted by a black rectangle). Click Add to add the sample position in the next available row or click Update to change the information in the selected (highlighted) row. -Follow the instructions above to navigate to another sample, maximize the signal intensity, and add the sample position until all sample positions are listed in Instrument Manual Control in the Stage section. -Select the first sample position in the Stage section in Instrument Manual Control and click Go To. This moves the stage to the first sample for the start of analysis. -Select the second sample position in the Stage section in Instrument Manual Control (it should be highlighted with a black rectangle). -In Vision Manager: -Select the first Position Change in the flowchart (this should represent moving from the first, starting sample location to the second sample location, prior to analysis of the second sample). -With the second sample position highlighted in Manual Control, click Load Position in the Vision Manager Position Change window. -Highlight the next sample position in Instrument Manual Control and then update the next Position Change in the Vision Manager flowchart. Do this for all positions in the flowchart. -Resave your flowchart. 7. Running the scans: -Turn off the TV monitor and light source (KL1500, inside the SAC) and the light in the room for the rest of the run. -Click Submit, and then Resume at the top of the Vision Manager window and monitor the X-ray source in Instrument Manual Control to make sure it turns on for the first scan. If there are any problems with the X-ray source not working, click Standby for the X-ray source in Manual Control, click Stop Run in Vision Manager. Next, in Vision Manager click Resume to start the run again. Stay long enough to ensure that the instrument goes from Survey to Region scans automatically. Note: If the run shifts to manual and does not continue from Survey to Region scans automatically, either manually click Resume to continue the scans between each transition or check the calibration of the iris and aperture. To check the calibration of the iris and aperture, in Instrument Manual Control open the iris and aperture windows at the top of the window and then scroll down to the open iris and aperture windows. Both should have a green light bulb indicating that they are calibrated. If not, then click the lightbulb next to Initialise, then the lightbulb next to Confirm. Then click the lightbulb next to Calibrate, the the lightbulb next to Confirm. This procedure will work to calibrate both the iris and the aperture. With the iris and aperture calibrated the run should continue without stopping between scans. Page7

8. Exporting data files: -Open Vision Processing on the desktop. -In Vision Processing, go to File and Open Dataset for Processing. -Navigate to your user folder and select the dataset to process under File. -Select data files for processing (ie. Survey scan, Region scan). -In Options, select Browser Actions. -Click the button next to Describe. -Select Vamas file and click apply. You will be prompted to save the Vamas files. Navigate to your folder and write in a file name in selection (eg. /C=/data/yourfoldername/datasetname). Click Ok. In your data folder, you will have the.vms file(s). Save it/them to a USB (Eventually we will save to a network drive). CasaXPS will open.vms files for data interpretation. Note: Record your analysis time (XPS, UPS, ion gun, electron imaging) in the log book. 9. Removing sample: Note: If the Instrument Manual Control window is not open, then in Vision Manager go to Window and select Manual Window. Note: If Vision Manager is not open, then consult the restarting instructions or contact a staff member. -In Instrument Manual Control, scroll down to vacuum. If the sample is in the SAC, open the STC-SAC valve (will be green if open). Note: The STC-SAC valve will not open if the sample transfer probe is moved and has a red light (must be green). -Turn on the light source (KL1500) -In Instrument Manual Control scroll the Stage window. -At the bottom of the Positions table select Clear all Rows. -Select Load Table and select Unload.dset under Files and click Ok (this will load the preset unload position of the analysis claw in the SAC) -Click on the unload position xyz coordinates line in the table to highlight the row and click Go To above the table to drive the SAC analysis claw into the unload position. -Turn the knob on the sample exchange probe clockwise and align the claw with the post on the sample holder. -Use the black controller (the Autostage Manual Controller) and press right (to go faster, while holding right, also press left ). Jiggle the sample transfer probe knob to hook the sample holder. -Pull the sample exchange probe out using the knob until you see a green light at the end of the probe. -Close the STC-SAC valve (Instrument Manual Control in Vacuum ). -Ensure that the STC-SAC valve is closed (Red). -Loosen (by partially unscrewing) the knobs on the door (by the sample exchange probe). -Vent the STC (in Vacuum in Instrument Manual Control). -Turn on the flow of N 2 Gas on the bottle and flow valve (on the pipe). -Hold the probe (support the weight) and completely unscrew knobs. -When the door seal opens a little (enough to open the door) turn off the N 2 Gas at both the bottle and the flow valve. Page8

Note: The door seal gasket will probably fall out Do not let it fall on the ground Catch the gasket when you open the door. -Open the door all the way and turn the probe knob clockwise until the claw end of the sample transfer probe is visible. -Remove the sample holder on the claw at the end of the sample transfer probe. -Turn the probe knob counterclockwise until the light at the end of the sample transfer probe is green. -Reseat the door seal gasket. Be sure it does not come out when trying to close the door if the seal gets pinched in the door, the STC will not pump down -Close the door and screw the door knobs back in (Do not overtighten). -In Instrument Manual Control, go to vacuum and pump STC. -Support the probe until the vacuum has sealed the sample exchange port. Note: The STC on the Vacuum schematic will go from pink to blue to cyan to orange - orange is good and indicates the pump is working. If this does not happen, lift the probe to support it and retighten the screws. Do not leave until you are sure the pump is working. When the STC turns yellow, you will start to see vacuum values. Page9