Nanotechnology Solutions Partner

Similar documents
Nanotechnology Solutions Partner

Nanotechnology Solutions Partner

The Most Accurate Atomic Force Microscope. Park NX-PTR Fully Automated AFM for Accurate Inline Metrology of Hard Disk Head Sliders.

Wafer defects can t hide from

B-AFM. v East 33rd St., Signal Hill, CA (888)

Developing an AFM-based Automatic Tool for NanoAsperity Quantification

NP-AFM. Samples as large as 200 x 200 x 20 mm are profiled by the NP-AFM system, and several stage options are available for many types of samples.

Agilent 87075C Multiport Test Set Product Overview

In-process inspection: Inspector technology and concept

Figure 1: AFM image of a Tip-check sample

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

TT-2 AFM. This compact, second. generation tabletop Atomic. Force Microscope has all the. important features and benefits. expected from a light

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

TT-AFM. For: up to 1 X 1 X 1/4. Vibrating, Non Vibrating, Phase, LFM. 50 X 50 X 17 μ, 15 X 15 X 7 μ. Zoom to 400X, 2 μ resolution

DIRECT DRIVE ROTARY TABLES SRT SERIES

Standard Operating Procedure of nanoir2-s

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Agilent 81600B Tunable Laser Source Family

Keysight Technologies Intrinsic Contact Noise: A Figure of Merit for Identifying High Resolution AFMs. Application Note

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Preface. The information in this document is subject to change without notice and does not represent a commitment on the part of NT-MDT.

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

R-1580A Microwave Downconverter. Product Brochure

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

Standard AFM Modes User s Manual

Scanning Probe Microscope Training. Wenhui Pang

Scanning System S-2100

Revitalize Indoor Content Delivery through Clearer and More Vivid Picture Presentation

Electron Beam Technology

MEMS METROLOGY USING A STROBED INTERFEROMETRIC SYSTEM

Advanced Test Equipment Rentals ATEC (2832)

YXLON Cougar EVO PLUS

EXPRESSION OF INTREST

Figure 1. MFP-3D software tray

About... D 3 Technology TM.

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

TR7500 SIII SERIES. AutomAted optical InsPeCtIon

Precision Nano Displacement System (PNDS)

Figure 2: components reduce board area by 57% over 0201 components, which themselves reduced board area by 66% over 0402 types (source Murata).

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Advanced Sensor Technologies

OSICS 8-Channel Modular Platform for DWDM Testing

CIRCOGRAPH. Non-Destructive Eddy Current Testing of Long Products such as Wires, Bars and Tubes

*Please note that although this product has been approved in Japan, its launch in other countries has not yet been confirmed.

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

SC24 Magnetic Field Cancelling System

UV Nanoimprint Tool and Process Technology. S.V. Sreenivasan December 13 th, 2007

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

LD OEM/LD PDS/LD PeCo

AFM Standard Operating Procedure

SC24 Magnetic Field Cancelling System

OM2000N INSTALLATION MANUAL

ZEBRA SE960HP OEM MINIATURE HIGH PERFORMANCE 1-D SCAN ENGINE. FEATURES Large working range from near contact to 100 in./254 cm. Small and lightweight

Explore the Art of Detection

Digital SWIR Scanning Laser Doppler Vibrometer

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Abstract. Keywords INTRODUCTION. Electron beam has been increasingly used for defect inspection in IC chip

MILLENNIA. The Benchmark In Diode-Pumped Solid-State Lasers.

Signal Stability Analyser

Revolutionary AOI Technology, Unbelievable Speed World's Fastest and Most Accurate 3D SPI

TT AFM LongBeach Procedures and Protocols V2.1

Quick Start Bruker Dimension Icon AFM

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

Brilliant indoor display solutions. Now ready for a close-up.

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

HyPrecision Waterjet. Optimizing waterjet performance

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

Digital BPMs and Orbit Feedback Systems

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

Analog Dual-Standard Waveform Monitor

University of MN, Minnesota Nano Center Standard Operating Procedure

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

MILLIMETER WAVE VNA MODULE BROCHURE

SPATIAL LIGHT MODULATORS

NEXT/RADIUS Shelf Mount CCU

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

All-in-one solutions For applications with imaging challenges, we offer a wide range of TDI solutions.

Semiconductors Displays Semiconductor Manufacturing and Inspection Equipment Scientific Instruments

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

HyPrecision Waterjet. Optimizing waterjet performance

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

The Versatility in Vibration Measurement Datasheet

The Transition to Patterned Media in Hard Disk Drives

Digital SWIR Scanning Laser Doppler Vibrometer

An impressive appearance

MTS/T-BERD Platforms WDMPMD Module

Overcoming Challenges in 3D NAND Volume Manufacturing

The Distortion Magnifier

SC26 Magnetic Field Cancelling System

CORONA & PLASMA FOR NARROW WEB

Advances in Roll-to-Roll Imprint Lithography for Display Applications Using Self Aligned Imprint Lithography. John G Maltabes HP Labs

ksa ScanningPyro ksa ScanningPyro Full Carrier Temperature Maps at the Click of a Button!

Electron Beam Technology

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

Transcription:

Nanotechnology Solutions Partner Park Systems Corp. KANC 4F, Iui-Dong 6-10, Suwon, Korea 443-270 Tel. +82-31-546-6800 Fax. +82-31-546-6805 www.parkafm.co.kr Park Systems Inc. 3040 Olcott St. Santa Clara, CA 95054 Tel. +1-408-986-1110 Fax. +1-408-986-1199 www.parkafm.com Park Systems Japan. NK Dai-ichi Bldg. 1F 1-17-1 Kanda-Nishikicho, Chiyoda-ku, Tokyo, 101-0054 Japan Tel. +81-3-3219-1001 Fax. +81-3-3219-1002 www.parkafm.co.jp Park Systems Singapore. 33, Ubi Avenue 3, #07-47 Vertex Tower A Singapore 408868 Tel: +65-6634-7470 Mobile: +65-9821-8868 www.parkafm.com

Decoupled XY & Z Scanners Automated Industrial AFM for In-line Wafer Inspection and Metrology. PROBLEMS Process engineers in the hard disk and semiconductor industries currently use costly FIB/SEM instrumentation to acquire roughness, side-wall angle, and height measurements in nanoscale dimensions. Unfortunately, FIB/SEM is destructive, slow, and has a high cost per measurement. PARK SYSTEMS SOLUTION The XE-Wafer is a fully automated industrial AFM that can acquire surface roughness, depth, and angle measurements on 200 mm & 300 mm wafers with speed, precision, and value in a production environment. BENEFIT The offers a non-destructive, in-line imaging tool capable of providing high resolution, direct, and repeatable measurements on multiple locations without damaging the sample. The increased precision and ability to monitor line-width roughness will lead allow process engineers to produce devices with higher performance, at a significantly lower cost than FIB/SEM. Park Systems introduces the industry s lowest noise, fully automated industrial AFM, the XE-Wafer. The completely automated AFM system is designed for high resolution surface roughness, trench width, depth and angle measurements on 200 mm & 300 mm wafers with sub-nanometer precision in a 24/7 production environment. Our True Non-Contact Mode enables non-destructive measurements even on soft structures such as photoresist trench surfaces. 1 Artifact-Free Metrology by Crosstalk Elimination Unique decoupled XY scanning system provides a flat scanning stage Flat and linear XY scan removes artifacts from background curvature Accurate feature measurements with industry leading gauge statistics Superior tool to tool matching 2 True Non-Contact Mode Imaging Less tip wear for prolonged high-quality and high-resolution imaging Immunity from parameter-dependent results observed in tapping imaging 10 times or longer tip life for general purpose & defect imaging 3 Precision Nanometrology Measurements Surface roughness measurement below 1Å RMS roughness Provides the precision angle measurement accuracy of less than 0.1 degrees Low noise floor enables surface flatness measurements for long range CMP metrology 4 High-Throughput Inline Automation Automatic data acquisition and analysis of angles, roughness, and trench features Cleanroom compatible with remote control (SECS/GEM) interface Automatic tip exchange (optional) Equipment Front End Module (EFEM) for automatic wafer handling (optional) Long range traveling stage for CMP profiling (optional) 5 Nanotechnology Solutions Partner Trusted partnership with customers to meet fast their changing requirements Application specific solutions that maximize throughput Modular software and hardware platform enable flexible application development 02-03 -

APPLICATION CD Measurements 6000 Superior accuracy and precision nanometrology increases yield while delivering the highest resolution and the lowest gauge sigma value for repeatability and reproducibility pxl 4000 2000 0-500 -250 pm 0 250 Sub-Nano Roughness Measurements of Substrates & Media Industry s lowest system noise, combined with the innovative True Non-Contact Mode, the most accurate roughness measurement can be obtained for the flattest of the substrate and media samples details of the defect. Critical Angle Measurements High precision calibration of Z-scan orthogonality provides the angle measurement accuracy of less than 0.1 degrees FEATURES Fully Automated Pattern Recognition Trench Measurements Utilizing a powerful combination of high resolution digital CCD camera and pattern recognition software, a fully automated pattern recognition and alignment is made possible for user applications. Unique True Non-Contact mode enables nondestructive in-line measurement of etch features as small as 45nm. Trench sample (Width : 60nm, Depth : 300nm) Automatic Measurement Control Automated software makes the operation effortless. Measurement recipes provide multi-site analysis with optimized settings for cantilever tuning, scan rate, gain, and set point parameters. Industry s Lowest Noise Floor High Precision CMP Profile Measurement A combination of low system noise with a very flat profiling capability, Park Systems provides an unprecedented CMP profiling application for the wafer manufacturing industry. To detect the smallest sample features and image the flattest surfaces, Park Systems has engineered instruments which hold the industry s lowest noise floor specification of < 0.5Å. Noise floor data is determined using a zero scan. With the cantilever in contact with the sample surface, the system noise is measured at a single point under the following conditions: 0 nm x 0 nm scan, staying in one point 0.5 gain, in contact mode 256 x 256 pixels pxl 04 l 05 - Decoupled XY & Z Scanners

20 40 60 ( CROSSTALK ELIMINATION ( XE ACCURATE AFM RESULTS BY CROSSTALK ELIMINATION (XE) Challenges of Accurate AFM Measurement Artifact Free Imaging A Software flattening leaves residual bow Artifact Free Imaging: Flat XY Scan Without Scanner Bowing The conventional AFM uses a piezoelectric tube for the x-y-z scanner, where x-y motion relies on the bending of the tube. The bending motion, however, introduces background curvature and therefore causes z position errors. Conventional systems regularly use software flattening to hide the background curvature; this can be an impossible task since the amount of curvature depends not only on scan size and scan speed, but also on x-y offset, z position, etc. Therefore, even after software flattening, a flat surface does not look flat as shown in the figure. Feedback Control Low residual bow Results less dependent on scan location Less than 1 nm No need for software processing (raw data) Accurate height measurements and sample imaging Flat XY Scan Without Scanner Bowing The Crosstalk Elimination (XE) fundamentally removes the scanner bowing, hence attaining flat XY scan with out-of-plane motion less than 1 nm regardless of scan locations, scan rates, and scan sizes. It shows no background curvature even on scans of the flattest samples such as that of an optical flat as shown in the figure, also with various scan offsets. Thus, the XE-AFM enables very accurate height measurement and precision nanometrology for the most challenging problems in research and industry. Laser PSPD Highly Linear and Orthogonal XY Scan Mirror Sample Cantilever Non-destructive Scan: Tip and Sample Preservation by Non-Contact AFM A B E C D D 100nm Standard (5 x 5 μm scan) 4,096 x 4,096 pixel image The flexure XY scanner decouples the X and Y scan motion so that the coupling between X and Y movement is minimized regardless of scan locations, scan rates, and scan sizes. Position sensors provide linear feedback control for the high accuracy and high precision measurements. X-Y-Z Piezo Tube Scanner X Y -X Z X-Y Scan Control The tube scanner is a slow actuator with highly limited Z-scan bandwidth of only 500 Hz or so. Therefore, the Z-servo response is too slow to implement Non-Contact Mode, a critical requirement for preservation of sharp tips and non-destructive imaging of soft biological samples. Non-destructive Scan Less tip wear for prolonged high-resolution imaging Minimized sample damage or modification Immunity from parameter-dependent results Imaging of soft sample surface XE Technology: Park Systems Answer to Accurate AFM Measurement Challenges of accurate AFM measurement calls for a completely new approach in the design of an AFM. Park Systems developed the Crosstalk Eliminated (XE) AFM based on decoupled flexure scanners where the XY scanner only moves the sample and the Z Scanner drives the probe. The XE-AFM fundamentally removes the scanner bowing, hence attaining flat XY scan, and dramatically improves the Z-servo response, resulting in superb tip preservation by True Non-Contact Mode. Mechanical Design Features Advantages Decoupled XY and Z Scanners 2D XY Flexure Scanner High Force Z Scanner Super Luminescent Diode (SLD) 06 l 07 - Decoupled XY & Z Scanners XY scanner only moves the sample and the Z scanner drives the probe Minimal Z Runout (Out-of-plane Motion) Large Z Servo Bandwidth Low Optical Coherence Flat XY Scan Without Scanner Bow Highly Linear and Orthogonal XY Scan Enabling True Non-Contact Mode Eliminates Optical Interference True Non-Contact Mode is Now a Reality True Non-Contact Mode, one of the distinctive advantages only realized by Park Systems Crosstalk Eliminated (XE) AFM, is a powerful method that enables AFM users to image and measure samples. Longer Tip Life and Less Sample Damage The sharp end of an AFM tip is so brittle that once it touches a sample, it becomes instantly blunt and limits the resolution of an AFM and reduces the quality of the image. U Contact Mode Non-Contact Mode z Distance, Z Repulsive Attractive Total interaction In True Non-Contact Mode, the tip-sample distance is successfully maintained at a few nanometers in the net attractive regime of inter-atomic force. The small amplitude of tip oscillation minimizes the tip-sample interaction, resulting in superb tip preservation and negligible sample modification. µm 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 XE-AFM 0 2.5 5 7.5 10 12.5 µm 3.7 μm Before After taking 20 images For softer samples, the tip will damage the sample and also result in inaccuracies of sample height measurements. Consequently, preserving tip integrity enables consistent high resolution and accurate data. True Non-Contact Mode of the XE-AFM superbly preserves the tip, resulting in much longer tip life and less sample damage. The figure, displayed in 1:1 aspect ratio, shows the unprocessed raw data image of a shallow trench isolation sample imaged by the XE-AFM, whose depth is also confirmed by scanning electron microscope (SEM). The same tip used in the imaging of the sample shows no tip wear even after taking 20 images.

AFM SOLUTIONS PARK SYSTEMS RELIABILITY Semiconductor With its ability to accurately measure critical dimensions in the micrometer to nanometer regime, Atomic Force Microscope (AFM) is becoming the tool of choice for applications involving surface roughness, trench depth, and line width characterization of various samples features and materials. Sample Range UCL Gage Repeatability and Reproducibility Due to the ever-decreasing size of components, manufacturers now require the highest level of quality control. Park Systems can provide 1 gage sigma (σ) of less than 1 Angstrom. Accuracy Part LCL Throughput Cost Effectiveness Correlation Thanks to its revolutionary platform designed for industrial metrology, the XE-AFM will correlate with any existing Park industrial AFMs that have been previously used for manufacturing, inspection, analysis, or research. System 2 R2 > 0.95 0.95 < Slope < 1.05 Accuracy Like Never Before System 1 Shrinking form factors are driving the need to design at the nanoscale level in the semiconductor markets. Traditional metrology tools have lacked the accuracy needed for nanoscale design and manufacturing. Park Systems has met this challenge in industrial metrology with enabling breakthroughs. Crosstalk Elimination (XE) enables artifact-free and non-destructive imaging New 3D AFM enables high resolution imaging of sidewall or undercut features Throughput Like Never Before AFMs that have enabled nanoscale design have traditionally not been fast enough for use in production quality control. All that has changed with Park Systems revolutionary gains in throughput enabling AFMs for use in automatic in-line manufacturing. System Uptime Our engineers and scientists adopted the most rigorous industry standard of product development to ensure the highest level of system reliability. The can be seamlessly incorporated as either an inline or offline inspection tool with minimal maintenance requirements. These include automatic tip exchange where our novel magnetic approach has a 99% success rate, higher than traditional vacuum techniques. Also, full access to raw data and a true partnership with customers are required for any process and throughput optimization. Cost-Effectiveness Like Never Before Accuracy and throughput in nanometrology must be delivered in a cost-effective solution to move successfully from research to inline manufacturing. Park Systems have met this cost challenge with industrial AFM solutions that address the need for faster, efficient automation and longer tip life. We cut costs by replacing slower and expensive SEM with efficient, automatic, and affordable 3D AFM for industrial in-line manufacturing. To pinpoint defects in new designs, manufacturers today need 3D information to characterize trench profiles and sidewall feature variation. Modular AFM platform allows rapid software and hardware changes, enabling cost-effective upgrades and better optimization for the most complex and demanding measurements in production quality control. Also, we lower the cost of ownership with at least 200% longer AFM tip life. The tapping forces of conventional AFMs cause faster tip wear, but our In True Non-Contact Mode AFMs maintain tip quality resulting in the lower total cost of ownership. Service & Maintenance Park Systems is committed to the highest level of service and support, and every effort is made to understand our industrial customers needs. We place the utmost importance on meeting promised delivery dates, guaranteed quality, and faithful after-sales service. 08 l 09 - Decoupled XY & Z Scanners

XEA & OPTIONS SPECIFICATIONS Software & User Interface Footprint XEA - Industrial Automation & Analysis XEA is a system software for automation that carries out the AFM measurement of a sample following the preset procedure written in a recipe file. User-friendly XEA architecture provides flexibility to operator to perform various system-wide functions. Minimum 3320 mm 600 940 880 600 300 Supports auto, semi-auto, and manual mode Editable measurement method for each automated procedure Live monitoring of the measurement process Automatic analysis of acquired measurement data XEP Data Acquisition All the user controls on AFM measurements are operated through XEP, the data acquisition program. The user-oriented interface provides easy operation of AFM. Simultaneous data acquisition of up to 16 images Maximum 4096 4096 image size Dedicated Force-distance and Cantilever spring constant calibration I-V spectroscopy with batch processing Script-level control through external program (LabVIEW, C++) 600 1050 300 1950 XEI Image Processing and Analysis XEI is the AFM image processing and analysis program. The powerful processing algorithms make the analysis easy and streamlined. With its most advanced and versatile imaging features, XE users can obtain essential and critical information from their experiment. Options Long Range Profiler Less than ±5 nm out-of-plane motion over 10 mm scan. Automatic Wafer Handler (EFEM or FOUP) 10 l 11 - Decoupled XY & Z Scanners Image analysis of line profile, region, 3D rendering Spectroscopy data analysis module (F-d, I-V) Multiple image comparison Directly copy/paste to presentation program Image overlay of two different images Automatic Tip Exchange (ATX) Automatic Tip Exchange performs fully automated tip exchanges in order to seamlessly continue automated measurement routines. It automatically calibrates cantilever location and optimizes measurement settings based on measurements of a reference pattern. Our novel magnetic approach to the tip exchange yields a 99% success rate, higher than the traditional vacuum techniques. Ionization System 5 2.5 0-2.5-5 0 Line Profile: Red The can be further customized by adding an automatic wafer handler (EFEM or FOUP or other). The high-precision, nondestructive wafer handler robot arm fully ensures users to receive fast and reliable wafer measurement automation. 2.5 5 7.5 10 Ionization system effectively removes electrostatic charges. It ionizes the charged objects and is very reliable since the system always generates and maintains an ideal balance of positive and negative ions without causing any contamination to the surrounding area. It also reduces the accidental electrostatic built-in charge that may occur during sample handling. System Specification 200 mm Motorized XY stage: travels up to 275 mm 200 mm 0.5 μm resolution 300 mm Motorized XY stage: travels up to ~375 mm 300 mm 0.5 μm resolution <1 μm repeatability Motorized Z stage: ~30 mm Z travel distance ~0.08 μm resolution <1 μm repeatability Motorized Focus Stage: 11 mm Z travel distance for on-axis optics Sample Thickness Allowance: up to 20 mm Full scan range Z run-out: < 2 nm, repeatability <1 nm COGNEX Pattern Recognition: pattern align resolution of 1/4 pixel Scanner Performances XY Scanner Range: 100 μm 100 μm (large mode) 50 μm x 50 μm (medium mode) 10 μm 10 μm (small mode) XY Scanner Resolution: 1.5 nm (high voltage mode) <0.2 nm (low voltage mode) Z Scanner Range: 12 μm (high voltage mode) 1.7 μm (low voltage mode) Z Scanner Resolution: < 0.2 nm Z Scanner Noise Floor: <0.05 nm (w/ Active Vibration Isolation System) AFM and XY Stage Control Electronics Controller Processing Unit: 600 MHz and 4800 MIPS Signal ADC & DAC: 16-bit, 500 khz bandwidth, internal lock-in Vibration, Acoustic Noise, and ESD Performances Floor Vibration: < 0.5 μm/s (10 Hz to 200 Hz w/ Active Vibration Isolation System) Acoustic Noise: >20 db attenuation w/ Acoustic Enclosure Dimension & Weight 200mm System: 880(w) 1050(d) 2024(h) w/o EFEM, 800 kg approx. (incl. main body) 1820(w) 1050(d) 2024(h) w/ EFEM, 1010 kg approx. (incl. main body) Control Cabinet: 800(w) 800(d) 1000(h) 160 kg approx. (incl. controllers) 600(w) x 800(d) x 2000(h) tower type 220 kg approx. (incl. controllers) 1780(w) 980(d) w/o EFEM 3050 (w) 980 (d) w/ EFEM Ceiling Height: 2000 or more Operator Working Space: 3300(w) x 1950(d), minimum (dimension unit: mm) 300mm System: 1220(w) 1200(d) 2024(h) w/o EFEM, 1150 kg approx. (incl. XE-3DM main body) 24(w) 1720(d) 2024(h) w/ EFEM 1450 kg approx. (incl. XE-3DM main body) Control Cabinet: 800(w) 800(d) 1000(h) 160 kg approx. (incl. controllers) 600(w) x 800(d) x 2000(h) tower type 220 kg approx. (incl. controllers) Wafer Handler (EFEM): 1270(w) x 1720(d) x 2024(h), 300 kg approx 1220(w) 1200(d) w/o EFEM 24(w) 1720(d) w/ EFEM Ceiling Height: 2000 or more Operator Working Space: 4500(w) x 3120(d) (dimension unit: mm) Facility Requirements Room Temperature (Stand By): 10 C ~ 40 C Room Temperature (Operating): 18 C ~ 24 C Humidity: 30% to 60% (not condensing) Floor Vibration Level: VC-E (3 μm/sec) Acoustic Noise: Below 65 db Pneumatics: Vacuum: -80 kpa CDA: 0.7 Mpa Power Supply Rating: 208~240 V, single phase, 15 A (max) Total Power Consumption: 2 KW (typical) Ground Resistance: Below 100 ohms