FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Date: April 29, 21 REPORT NO. 1167677LAX-5 TEST OF ONE DYNAMIC WHITE LED PAR CW MODEL NO. OPTI TRI WHITE II RENDERED TO ELATION PROFESSIONAL 6122 S. EASTERN AVENUE COMMERCE, CA, 9 TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number 5519256. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-28: Electrical and Photometric Measurements of Solid State Lighting DESCRIPTION OF SAMPLE: The client submitted one prototype sample of model number Opti Tri White II. The sample was received by Intertek on April 25, 21, in undamaged condition and one sample was tested as received. The sample designation was LAN125928-1. DATES OF TESTS: April 28, 21 through April 29, 21. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY Model No.: Description: Opti Tri White II Dynamic White LED PAR CW Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW) Sphere 178 36.51 8.86 Result Goniometer 36.3 8.53 Criteria Power Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Coordinate (x) Coordinate (y) Coordinate (u') Coordinate (v') Result.95 22.71 6521 72.8-25...312.331.197.69 EQUIPMENT LIST Equipment Used LabSphere Power Supply LapSphere 3M Integrating Sphere LabSphere Spectrometer California Instruments Power Supply Yokogawa Power Meter Extech Instruments Stop Watch Omega Environmental Monitor LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Omega Environmental Monitor Tape Measure Stopwatch Model Number LPS-1-833 CA-11821-LRT CDS-32 CSW555 WT333 6T CW1251 WT21 ibthx-w 33-28 36551 Control Last Date Calibration Number Calibrated Due Date 832 5/23/13 5/23/1 83 83 1338 1319 5/1/13 5/1/1 138 9/5/13 9/5/1 886 9/1/213 9/1/21 93 9 95 11/1/13 11/1/1 886 9/9/13 9/9/1 68 12/9/13 12/9/1 138 11/5/213 11/5/21 Report No.1167677LAX-5 2 of 7 Date: April 29, 21
TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere CDS 32 Spectrometer and Three Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The calibration of the sphere spectrometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Report No.1167677LAX-5 3 of 7 Date: April 29, 21
RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Current Luminous Lumen Base Voltage Current Power Power ATHD Flux Efficacy Intertek Sample No. Orientation {Vac} (ma) (Watts) Factor (%) (Lumens) (LPW) LAN125928-1 UP 12. 321.7 36.51.95 22.71 178 8.86 Correlated Color Temperature (K) 6521 CRI CRI -Ra -R9 DUV 72.8-25.. CIE 31 Coordinate.312 CIE 31 Coordinate (y).331 CIE 76 Coordinate (u ).197 CIE 76 Coordinate (v ).69 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm 35 -.21 23.52 53 2.36 62 12.15 71 355 -.5 5 37.18 535 21.3 625 11.15 715 36.122 5 5.92 5 21.5 63 1.18 72 365 -.39 55 38.3 55 21.65 635 9.25 725 37 -.1 6 2.21 55 21.67 6 8.38 73 375 -.7 65 15.97 555 21.6 65 7.526 735 38 -.7 7 11.13 56 21.5 65 6.767 7 385 -.12 75 7.561 565 21.23 655 6.66 75 39 -.23 8 5.7 57 2.91 66 5.28 75 395.3 85 5.95 575 2.6 665.835 755 -.1 9 5.2 58 19.89 67.278 76 5.82 95 6.35 585 19.16 675 3.791 765 1.26 5 8.2 59 18.22 68 3.356 77 15.693 55 1.7 595 17.21 685 2.952 775 2 1.682 51 13.3 6 16.27 69 2.587 78 25 3.731 515 15.76 65 15.27 695 2.269 3 7.382 52 17.8 61 1.25 7 1.998 35 13.51 525 19.26 615 13.21 75 1.75 mw/nm 1.5 1.38 1.17 1.31.9.77.67.63.51.5.1.353.295.263.2 (mw/nm) Spectral Data Over Visible Wavelengths 5. 5.. 35. 3. 25. 2. 15. 1. 5.. 35 5 5 55 6 65 7 75 8 Nanometers Report No.1167677LAX-5 of 7 Date: April 29, 21
RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Sample No. LAN125928-1 Base Orientation UP Voltage {Vac} 119.9 Current (ma) 321.3 Power (Watts) 36.3 Power Factor.96 Absolute Luminous Flux (Lumens) Lumen Efficacy (Lumens Per Watt) 8.53 Intensity (Candlepower) Summary at 25 C - Candelas Maximum Candela Value 132 Angle 5 1 15 2 25 3 35 5 5 55 6 65 7 75 8 85 9 22.5 1385 13892 13111 12952 639 683 1976 28 532 55 232 228 127 126 71 75 5 38 35 26 1 2 9 11 19 6 5 13886 1275 652 1987 5 25 1 78 7 5 1 12 7 8 7 67.5 13932 1263 668 2 559 23 15 75 58 23 3 8 8 12 2 9 9 1395 125 686 211 573 28 18 9 1 28 27 17 9 19 Report No.1167677LAX-5 5 of 7 Date: April 29, 21
RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 1 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone -3 - -6 6-9 -9 9-18 -18 Lumens 1668 1721 1759 8.8. % Luminaire 9.3 97.3 99.5.5 1.. 1. Zone -1 1-2 2-3 3- -5 5-6 6-7 7-8 8-9 Lumens. 967.8 581.1 118.8 52.9 2.5 13.8 5. 2.2 % Luminaire. 5.7 32.9 6.7 3. 1..8.3.1 1-11.. Report No.1167677LAX-5 6 of 7 Date: April 29, 21
PICTURE (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Erik Linares Technician Lighting Division Kenda Branch Engineer Lighting Division Attachment: None Report No.1167677LAX-5 7 of 7 Date: April 29, 21